ClickCease Data Fusion Correlator (N0016426SNB38) | Closed - MatchAwards

Data Fusion Correlator

Status
Closed, the response deadline passed on Mar 20, 2026
Agency
United States Department of the Navy
Office
CRANE, USA
Notice type
Special Notice
Solicitation number
N0016426SNB38
NAICS
541511 - Custom Computer Programming Services
PSC
AC13 - NATIONAL DEFENSE R&D SERVICES; DEPARTMENT OF DEFENSE - MILITARY; EXPERIMENTAL DEVELOPMENT
Posted
2026-03-03
Deadline
2026-03-20
Place of performance
Crane, Indiana 47522, UNITED STATES

Description

Special Notice: N0016426SNB38

Agency: Department of the Navy

Office: Naval Sea Systems Command

Location: Naval Surface Warfare Center (NSWC) Crane Division

NAICS Code: 541511

RFI Release Date: 12 February 2026

RFI Responses Due: 06 March 2026 – 4:00 P.M. EST

Request for Information (RFI)

Data Fusion Correlator

PURPOSE

           

This special notice is to inform vendors of a Request for Information (RFI). The purpose of this RFI is to collect information from the general public about Data Fusion Correlator topics in the RFI.  Based off the information collected from the RFI, the Government may send out a Request for Solutions (RFS) with the intent of awarding a Project Order under the Expeditionary Missions Consortium (EMC2) Other Transaction Agreement (OTA) in accordance with 10 U.S.C. § 4022.

Background

SENSEI is an integrated multi-sensor, multi-weapon, multi-domain counter-unmanned system (C-UxS); its objective is to detect-to-defeat Counter-small Unmanned (Air, Ground, Surface, Undersea) System (C-sUxS) to protect Navy/DoD critical infrastructure and assets.​ While SENSEI hosts a wide range of sensors, those sensors have inherent limitations in coverage, accuracy, and susceptibility to noise, clutter, or environmental conditions which may cause uncertainty, bias, or conflicting information, limiting their effectiveness in detecting, tracking, and effecting unmanned threats.

Feedback will not be provided and responses to the RFI papers will not be returned.

Objectives

Topics to be Addressed within RFI Response

  1. Describe the software product and overall function in paragraph form.
    1. Discuss what level of fusion is performed as pertaining to Joint Directors of Laboratories Data Fusion Model
    2. Is the product fielded/operationally used? Discuss current use cases and/or test events the product has been deployed/used.
  2. Data Alignment/Synchronization/Heterogeneity:

Note: The term heterogeneity implies that data varies significantly in type, format, structure, quality, or distribution, coming from diverse sources like databases, text, or sensors, making it complex to integrate and analyze compared to uniform (homogeneous) data, requiring preprocessing to find patterns.

    1. How does the product handle inputs from sensor with varying sample rates?
    2. What is the maximum sample rate variance from two track sources that can be correlated?
    3. How does the system handle the dynamic addition or subtraction of sensor inputs?
    4. What is the maximum position variance from two track sources that can be correlated?
    5. Is the fusion/correlation product able to maintain track continuity (single track ID per object) even if the source data for the track changes IDs?
    6. What is the maximum sample rate the Data Fusion Correlator can ingest/handle? If maximum is not available, provide highest tested or highest sample rate the product was operated with.
    7. What is the minimum number of data sources required for a fused track output? (If only one track is fed in, will the same track be output, or will fused track be output only if more than one data source is present?
    8. What is the maximum number of data sources that can be used for a single fused track?
    9. What is the number of simultaneous tracks that can be processed (assuming COTS hardware and no other hardware constraints)?
  1. Latency
    1. What is the latency for fusion of similar sensor sources (e.g. two radars pointed at the same AOR)?
    2. What is the latency for fusion of dissimilar sensor source (e.g. radar sensor with minimal delay but higher position error, and RF sensor with large delay but small positional error)?
  2. Error
    1. What are the average error improvements when fusing two similar tracks (i.e. two radar sensors with similar accuracy)?
    2. Can the spurious track errors be characterized? How often does the fusion product produce two tracks when only one track is present? How often does the track split into multiples when only one target is present?
  3. Track Metrics/Figures of Merit
    1. What, if any, figures of merit are provided with the fused track (i.e. confidence, error, covariance matrix)?
    2. Is assignment of different confidences, errors possible based on the data source (i.e. source 1 is an acoustic sensor, and although covariance is not produced with each detection/track, all incoming tracks can be assumed to have same error values)?
  4. Integration/Functionality
    1. Has the correlator been integrated with any C2 systems? Which systems?
    2. Can the correlator operate headless? How is the configuration (if any) of the correlator achieved (i.e. GUI, configuration file, source code changes)
    3. What are minimum/recommended hardware resources that need to be allocated to the correlator process?
    4. What OS does the correlator operate on natively?
    5. What is the integration cost/deployment cost of the correlator. Is there a license associated with the correlator.
  5. Swarm Data Fusion Considerations
    1. How many simultaneous tracks can system maintain?
    2. How does system handle Track Swap/ Track Crossing (when two targets cross paths)?
    3. How are clusters of targets handled? Non-targets? Mixture?
    4. Does performance degrade as maximum number is approached? Surpassed?
  6. Is there any other information and/or metrics pertaining to your solution that you deem important/necessary and critical?
    1. What metrics do you believe are critical when testing the data fusion products?

Note:

Format Requirements of the RFI Papers

Submission Instructions

Respondents are required to submit complete RFI documents that demonstrate the objectives identified above.

Submit responses and technical questions to the ATI email address listed below:

emc.responses@ati.org

For general submission questions, please contact the EMC² Consortium Manager, ATI, at emc@ati.org or visit the EMC² website at emccrane.org for membership requirements.

This RFI is issued solely for information purposes. It does not constitute an RFS or a promise to issue an RFS in the future. This RFI does not commit the Government to contract for any supply or service in any manner. Respondents are advised that the U.S. Government will not pay for any information or administrative costs incurred in response to this RFI; all costs associated with responding to this RFI will be solely at the interested parties' expense. Not responding to this RFI does not preclude participation in any future RFS, if any is issued. All interested parties should visit the EMC2 website at https://emccrane.org/ to become a member of the consortium to view the future possible RFS. 

Contracting Office Address:

300 Hwy 361
Crane, IN 47522
United States

Primary Point of Contact.:

Bradley Axsom

bradley.l.axsom.civ@us.navy.mil

Phone: 812-381-7732

Secondary Point of Contact:

Judy Blanton

judith.a.blanton3.civ@us.navy.mil

Phone: 812-381-7156 

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of the Navy posted in February 2026