<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_navy/posts/115825823396991159" -->

---
title: MANIFOLD, PRESS RED (N0010426QZA56) | Closed - MatchAwards
description: MANIFOLD, PRESS RED. United States Department of the Navy. Solicitation N0010426QZA56. NAICS 332919 - Other Metal Valve and Pipe Fitting Manufacturing. Deadline 2026-08-28. ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (NAVICP...
canonical: https://matchawards.com/dept_of_the_navy/posts/115825823396991159
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: MANIFOLD, PRESS RED (N0010426QZA56) | Closed
og:url: https://matchawards.com/dept_of_the_navy/posts/115825823396991159
og:description: MANIFOLD, PRESS RED. United States Department of the Navy. Solicitation N0010426QZA56. NAICS 332919 - Other Metal Valve and Pipe Fitting Manufacturing. Deadline 2026-08-28. ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (NAVICP...
og:image: https://matchawards.com/system/accounts/avatars/000/000/085/original/a0262fe00d6c038b.png?1638992122
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# MANIFOLD, PRESS RED

Status

Closed, the response deadline passed on Aug 28, 2026

Agency

[United States Department of the Navy](/dept%5Fof%5Fthe%5Fnavy)

Office

MECHANICSBURG, USA

Notice type

Solicitation

Solicitation number

N0010426QZA56

NAICS

[332919 - Other Metal Valve and Pipe Fitting Manufacturing](/groups/455)

PSC

4820 - VALVES, NONPOWERED

Category

[Machinery & Components (5.1)](/categories/industrial-products-and-services/machinery-and-components)

Posted

2026-08-04

Deadline

2026-08-28

## Description

ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (NAVICP REVIEW FEB 1991)(FEB 1999)|1|See specification sections C and E.| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| INSPECTION AND ACCEPTANCE - SHORT VERSION|8|x||x|||||| GENERAL INFORMATION-FOB-DESTINATION|1|b| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report & Invoice - Material ||TBD|N00104|TBD|TBD|N50286|TBD|||N/A|||||| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|one year from date of delivery|one year from date of delivery||||| WARRANTY OF DATA--BASIC (MAR 2014)|2||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11|||||||||||| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (OCT 2025)|13|||||||||||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2025)(DEVIATION 2025-O0003 AND2025-O0004))|13|332919|750|||||||||||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||x| 1.This is a procurement for the Level One Program. 2.DD1423 Data Item A001 (Inspection and Test Plan) may be waived if already onfile at NAVSUP WSS Mechanicsburg. 3.All contractual documents (i.e. contracts, purchase orders, task orders,delivery orders, and modifications) related to the instant procurement areconsidered to be "issued" by the Government when copies are either depositedin the mail, transmitted by facsimile, or sent by other electronic commercemethods such as email. The Government?s acceptance of the contractor?sproposal constitutes bilateral agreement to "issue" contractual documents asdetailed herein. 4.Partial and early delivery of requirement is authorized and desired and is at no additional cost to either the vendor or the Government. 5.NAVSUP WSS will be considering past performance in the evaluation of offers.See Clause 252.204-7024\. 6.This award will be issued bilaterally, requiring the contractor?s written acceptance prior to execution. 7.This is a rated order certified for national defense use and the Contractor will follow all requirements of the Defense Priorities and Allocations System Regulation (15 CFR 700), see clause 52.211-14\. 8\. This item requires Oxygen Cleaning and Navy source certification. 9.The following proposed delivery schedule applies:Submission of all certification data CDRLS 20 days prior to delivery.PNSY review/acceptance of certification CDRLS 18 working days after receipt. \\ 1\. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 1.1.1 This ;Pressure Reducing Manifold; contains non-metallic materials which must satisfy the toxicity and flammability requirements of NAVSEA SS800-AG-MAN-010/P-9290\. Use of any material other than that specified requires special engineering approval and may require testing. 1.1.2 LI-SOC ITEM - It has been determined that this item falls within both the Level I boundary and the Scope of Certification (SOC) boundary. 2\. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under "Documents References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.2.2 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. 2.2.3 The documents and drawings listed below under DRAWING NO. are not provided with this Contract/Purchase order. DRAWING NO CAGE REV DISTR CD ;S1E10205 99517 H B S3C10054 99517 E B S3C10053 99517 E B V3D10431 99517 J B V3D10436 99517 E B V3D10435 99517 E B V3D10434 99517 C B V3D10437 99517 G B F3C10321 99517 D B WI-S1E10205 99517 ^ B CDS-S1E10205-02 99517 A D; DOCUMENT REF DATA=FED-STD-H28 | | |B |190424|A| | | DOCUMENT REF DATA=FED-STD-H28 |0020| |B |941221|A| |01| DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=ASTM-B138 | | | |110101|A| | | DOCUMENT REF DATA=ASTM-B150 | | | |190401|A| | | DOCUMENT REF DATA=ASTM-A182 | | | |240301|A| | | DOCUMENT REF DATA=ASTM-A240 | | |B |241115|A| | | DOCUMENT REF DATA=ASTM-A262 | | | |150901|A| | | DOCUMENT REF DATA=ASTM-A574 | | | |211201|A| | | DOCUMENT REF DATA=ASTM-A581 | | |B |950910|A| | | DOCUMENT REF DATA=ASTM-A582 | | | |221101|A| | | DOCUMENT REF DATA=ASTM-F606 | | | |191115|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |230223|A| |01| DOCUMENT REF DATA=MIL-DTL-1222 | | |J |001208|A| | | DOCUMENT REF DATA=MIL-STD-1330 | | |E |220516|A| | | DOCUMENT REF DATA=MIL-STD-2035 | | |A |950515|A| | | DOCUMENT REF DATA=SAE AMS 5643 | | |W |211201|A| | | DOCUMENT REF DATA=ISO\_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=MIL-DTL-15024 | | |G |180303|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-DTL-18240 | | |F |000313|A|1 | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A|1 | | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=SAE AMS-QQ-S-763 | | |D |150301|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=0900-LP-001-7000 | | | |810101|C| |01| DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | |1 |191112|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=SS800-AG-MAN-010/P-9290 | | |A |200324|A| |42| DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3\. REQUIREMENTS 3.1 ;The Pressure Reducing Manifold assembly must be in accordance with Vacco drawing S1E10205, part number S1E10205-02, with Vacco document WI-S1E10205 and Certification Data Sheet CDS-S1E10205-02, except as amplified or modified herein.; 3.2 ;NOTE: Vacco document WI-S1E10205 must be Revision D (R/C).; 3.3 Oxygen Cleaning - This material must be cleaned, tested, packaged & labeled by trained personnel and procedures in accordance with MIL-STD-1330, General. 3.4 Material for Parts Requiring Certification - Quantitative chemical and mechanical analysis is required for the parts listed below unless specifically stated otherwise: ;Vacco drawing S1E10205, part number S1E10205-02 (Manifold Assembly); Part - ;BODY, Item 1; Material - ;SAE-AMS-QQ-S-763, Class 304, Condition A or ASTM-A182, Class 304 or ASTM-A240, Class 304; Part - ;FILTER CAP, Item 2; Material - ;ASTM-A582, Type 303; Part - ;PORT ADAPTER, Item 3; INLET PORT, Item 12; and OUTLET PORT, Item 13; Material - ;SAE-AMS-5643, Condition H-1025; Part - ;PLUG, Item 6; Material - ;SAE-AMS-QQ-S-763, Class 304, Condition A; Part - ;PLUG, Item 23; Material - ;ASTM-A582, Type 303; Part - ;SOCKET HEAD CAP SCREW, Items 27, 28, 29, 30, 31, 32, 33, and 35; Material - ;SAE-AMS-5643, Condition H-1025 with self-locking element per MIL-DTL-18240, Type L; ;Vacco drawing S3C10054, part number S3C10054-01 (Bleed Block Assembly); Part - ;BODY, Item 1; Material - ;SAE-AMS-QQ-S-763, 300 Series or ASTM-A582, 300 Series; Part - ;STEM, Item 2; Material - ;SAE AMS 5643, Condition H-1025 with self-locking element to meet the intent of MIL-DTL-18240, Type N; ;Vacco drawing S3C10053, part number S3C10053-01 (Gauge Connection Assembly); Part - ;BODY, Item 1; Material - ;SAE-AMS-QQ-S-763, 300 Series or ASTM-A582, 300 Series;; Part - ;STEM, Item 2; Material - ;SAE AMS 5643, Condition H-1025 with self-locking element to meet the intent of MIL-DTL-18240, Type N; ;Vacco drawing V3D10431, part numbers V3D10431-06 and V3D10431-05 (Regulator Assemblies); Part - ;POPPET, Item 2; STEM, Item 3; PISTON, Item 6; and STEM GUIDE, Item 16; Material - ;SAE-AMS-5643, Condition H-1025; Part - ;DISC COMPRESSOR, Item 4 and BODY, Item 5; Material - ;SAE-AMS-QQ-S-763, Class 304, Condition A; Part - ;DOME CAP, Item 7; Material - ;ASTM-A582, Type 303; Part - ;SEAL TUBE, Item 12; Material - ;ASTM-A581, Type 303, Condition A or ASTM-A582, Type 303, Condition A; Part - ;ORIFICE BLOCK, Item 15; Material - ;SAE-AMS-5643, Condition H-1150; Part - ;SELF-LOCKING SOCKET HEAD CAP SCREWS, Item 24; Material - ;SAE-AMS-5643, Condition H-1025 with self-locking element per MIL-DTL-18240 , Type L; ;Vacco drawing V3D10436, part number V3D10436-01 (Regulator Control Block Assembly); Part - ;BODY, Item 1 and ORIFICE BLOCK, Item 2; Material - ;SAE-AMS-QQ-S-763, Class 304, Condition A; Part - ;SEAT, Item 3;; Material - ;ASTM-B138, Alloy C67500 or ASTM-B150, Alloy C62400 or Alloy C63200; Part - ;STEM, Item 5; Material - ;SAE-AMS-5643, Condition H-1025; Part - ;GLAND, Item 6; Material - ;ASTM-B138, Alloy C67500, Half Hard; ;Vacco drawing V3D10435, part number V3D10435-01 (Inlet and By-Pass Valve Assemblies); Part - ;ORIFICE BLOCK, Item 1; Material - ;ASTM-A582, Type 303, Condition A; Part - ;BONNET, Item 2; Material - ;SAE-AMS-QQ-S-763, Class 304, Condition A; Part - ;POPPET, Item 3; Material - ;SAE-AMS-5643, Condition H-1025; ;Vacco drawing V3D10434, part number V3D10434-01 (Outlet Valve Assemblies); Part - ;ORIFICE BLOCK, Item 1 and BONNET, Item 2; Material - ;ASTM-A582, Type 303, Condition A; Part - ;POPPET, Item 3; Material - ;SAE AMS 5643, Condition H-1025; ;Vacco drawing V3D10437, part number V3D10437-01 (Relief Valve Assembly); Part - ;BODY, Item 1; Material - ;SAE-AMS-5643, Condition H-1025; ;Vacco drawing F3C10321, part number F3C10321-225 (DP Indicator); Part - ;BODY, Item 1 and BONNET, Item 4; Material - ;ASTM-A582, Type 303; Part - ;PISTON, Item 2; Material - ;SAE-AMS-5643, Condition H-1025; Part - ;ADJUSTING SCREW, Item 9; Material - ;ASTM-A582, Type 303 with self-locking element to meet the intent of MIL-DTL-18240, Type N; 3.5 Testing Certification - Certifications are required for the following tests on the items listed below. Additional testing on other piece parts (if any) per applicable drawings and specifications is still required, but certifications are only required as listed below. Test - 5x Visual Magnification or Dye Penetrant Inspection (root layer) Item - Weldments Performance - T9074-AS-GIB-010/271 Acceptance - MIL-STD-2035 Test - Visual and Dye Penetrant Inspection (final layer) Item - Weldments Performance - T9074-AS-GIB-010/271 Acceptance - MIL-STD-2035 Test - ;Liquid Penetrant Inspection; Item - ;SELF-LOCKING SOCKET HEAD CAP SCREWS: Items 27, 28, 29, 30, 31, 32, 33, and 35 drawing S1E10205 and Item 24 of drawing V3D10431; Performance - T9074-AS-GIB-010/271; Sampling must be per MIL-DTL-1222 Acceptance - MIL-DTL-1222 Test - ;Production Testing; Item - ;Each Manifold Assembly; Performance - ;PTP developed from S1E10205; Acceptance - ;PTP developed from S1E10205; Test - Intergranular Corrosion Test (Only for SAE-AMS-QQ-S-763, Classes 304-condition A, 304L, 316-condition A, 316L, 317-condition A, 321 and 347 material. Test must be performed prior to fabrication/machining) Item - ;BODY, Item 1 and PLUG, Item 6 of drawing S1E10205; BODY, Item 1 of drawing S3C10054; BODY, Item 1 of drawing S3C10053; DISC COMPRESSOR, Item 4 and BODY, 5 of drawing V3D10431; BODY, Item 1 and ORIFICE BLOCK, Item 2 of drawing V3D10436; and BONNET, Item 2 of drawing V3D10435; Performance - SAE-AMS-QQ-S-763 Acceptance - SAE-AMS-QQ-S-763 Test - Intergranular Corrosion Testing Item - ;BODY, Item 1 of drawing S1E10205 (if ASTM-A240 material option used); Performance - ASTM-A262, Practice E Acceptance - ASTM-A262 Test - Non-Destructive Tests Item - ;Weld Repair (as applicable); Performance - Per applicable fabrication specification Acceptance - Per applicable fabrication specification 3.6 The pressure tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For pressure tests below 100 PSIG, the pressure tolerance must be +1 PSIG / -0 PSIG. For pressure tests at or above 100 PSIG up to and including 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 50 PSIG. For pressure tests above 2500 PSIG, the pressure tolerance must be +2% / -0 PSIG, rounded off to the nearest multiple of the smallest graduation on an analog test pressure gauge, not to exceed 200 PSIG. The pressure test time tolerance must be as specified in the assembly drawing, detail drawing, design specification or elsewhere in this contract. Where pressure test time tolerances are not provided by drawings, specifications or specified elsewhere in this contract, the following must be used: For a test duration up to and including 1 hour, the tolerance must be +5 minutes / - 0 minutes. For a test duration of more than 1 hour up to and including 24 hours, the tolerance must be +30 minutes / - 0 minutes. For a test duration of more than 24 hours, the tolerance must be +60 minutes / - 0 minutes. 3.7 Heat Treat Requirements - Mechanical properties (via tension testing and hardness testing if hardness is required by the applicable material specification) are required for each heat in each heat treat charge for ASTM-A234, ASTM-A403, ASTM-A182, and ASTM-A105 material. 3.7.1 If heat treatment is performed in continuous-type furnaces with suitable temperature control and equipped with recording pyrometers so that complete heat-treatment records are available, a heat-treatment charge must be considered as any continuous run not exceeding an 8-hr duration. One tension test must be taken from one forging per heat in each heat treatment charge at a minimum of every 8 hours. 3.7.2 Certification of Mechanical Properties (Mechanical Analysis, Tension Testing) must include the condition furnished. The contractor must maintain a complete record on file of the heat treatment given each piece, including stress relief. The contractor must provide either the record of the final heat treatment or a heat treatment certification statement. The certification statement must be signed by the heat-treater and include the date of heat treatment, duration and temperature of heat treatment operations and quenching medium (if required). 3.8 Wedge Tensile Test Specimens (Headed fasteners) - A wedge tensile test must be conducted on a Full Size Fastener for each production lot and reported aspart of the Mechanical Properties. The required specimens for the Wedge Tensile Test must be separate fasteners from those required for the Yield Test. 3.8.1 Testing for Socket Head Cap Screws must be in accordance MIL-DTL-1222, paragraphs 4.5.2.3 and 4.5.2.3.1\. 3.8.2 Testing for all other Headed Fasteners with a nominal diameter greater than 1/4-inch must be in accordance with ASTM-F606 for grades 5, 8, B7, and B16.For all other grades, the following wedge angles must be used. a. Except as specified in item c below, fasteners with a nominal diameter of 1/4-inch through 1-inch (inclusive) must be tested with a ten degree wedge. b. Except as specified in item c below, fasteners with a nominal diameter over 1-inch must be tested with a six degree wedge. c. Fasteners that are of grades 8, B7, B16, 410, 416, 416Se, 431, and 630 and are threaded within one diameter to the underside of the head must be tested as follows: Sizes 1/4 inch through 3/4 inch (inclusive) Use a six degree wedgeSizes over 3/4 inch Use a four degree wedge d. Fasteners which have passed testing with wedge angles greater than those specified should be considered acceptable. 3.8.3 For fasteners having a length less than the minimum specified in Table 1 of ASTM-F606, one "test specimen fastener" must be manufactured from each lot of fasteners and tested to represent that lot. The length of these test specimen fasteners must meet the minimum specified in table 1 of ASTM-F606 but must not exceed it by more than 1/4 inch. Test specimen fasteners must be the same type, style, and diameter as the production lot and must be manufactured from the same starting material, using the same manufacturing techniques as the production lot, and must be heat treated (if required) along with the production lot. 3.9 Off-Gassing Analysis is required in accordance with NAVSEA SS800-AG-MAN-010/P-9290A, Appendix F, paragraphs F4.2, F4.3, and F4.4\. Off-Gassing Analysis is not required for every lot of stock material (plate, bar, castings, etc.) formed by the same vendor, if NAVSEA SS800-AG-MAN-010/P-9290A, Section F4.4 is satisfied. 3.9.1 Off-Gassing Analysis must be conducted by one of the following labs: 1 ALS Simi Valley Mr. Michael Conejo 2655 Park Center Dr. Suite A Simi Valley, CA 93065 Phone (805) 577-2083 2 Electric Boat Corp. DSS-ACL Craig Adamson 75 Eastern Point Road Groton, CT 06340-4989 Phone (860) 433-5866 3 Naval Surface Warfare Center - Crane (NSWC-Crane) Mike Jones 300 Highway 361 Bldg 3395 Crane, In 47522-5001 Phone (812) 854-6313 Note: This lab contains the only chamber authorized for ordnance sampling. 4 Naval Experimental Diving Unit (NEDU) Chuck Mayberry 321 Bullfinch Road Panama City, Fl 32407 Phone (850) 230-3163 3.9.2 Each item being supplied for the off-gas test must be odor tested prior to shipment to the off-gas test lab. Perform the odor test per the requirements specified in paragraph F.4.4.1.b of NAVSEA SS800-AG-MAN-010/P-9290A. Note: The vendor must contact lab to determine test chamber size and depth limitations. Note: Each shipment of material to be off-gas tested must be accompanied by paperwork identifying the following: - The NSN - The Procuring Activity - The Contract Number - The Serial Numbers of units in shipment 3.9.3 The listed labs have been assessed and accepted; however, due to the requirements of biennial reassessments there could be occasions when a given lab may have restrictions levied on them. It is incumbent upon the customer to contact the lab or NAVSEA 07Q4 to ascertain the current lab status. NAVSEA point of contact is Mr. Greg Sorrells (SEA 07Q43) at (202)781-0910\. 3.10 O-ring grooves and mating sealing surfaces must be inspected per the contractually invoked drawings or specifications. When the drawings or specifications do not provide specific defect criteria or state t 

<!-- mobian-agent-ad sponsored="true" id="e366df60-7faf-4725-be00-62f66200d3fc" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/machinery-and-components?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/workspace/contract/opp/b1dbf5c8ded84b7399b1c84ab7042855/view)

[More from United States Department of the Navy posted in January 2026](/dept%5Fof%5Fthe%5Fnavy/archive/2026-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"MANIFOLD, PRESS RED","description":"ITEM UNIQUE IDENTIFICATION AND VALUATION (JAN 2023)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (NAVICP REVIEW FEB 1991)(FEB 1999)|1|See specification sections C and E.| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| INSPECTION AND ACCEPTANCE - SHORT VERSION|8|x||x|||||| GENERAL INFORMATION-FOB-DESTINATION|1|b| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (JAN 2023)|16|Stand-Alone Receiving Report - Certifications Combo - Receiving Report \u0026 Invoice - Material ||TBD|N00104|TBD|TBD|N50286|TBD|||N/A|||||| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| WARRANTY OF SUPPLIES OF A NONCOMPLEX NATURE (JUNE 2003)|6|one year from date of delivery|one year from date of delivery||||| WARRANTY OF DATA--BASIC (MAR 2014)|2||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM-BASIC (FEB 2024)|11|||||||||||| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (OCT 2025)|13|||||||||||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024))|5|||||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (FEB 2024)|1|| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2025)(DEVIATION 2025-O0003 AND2025-O0004))|13|332919|750|||||||||||| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||x| 1.This is a procurement for the Level One Program. 2.DD1423 Data Item A001 (Inspection and Test Plan) may be waived if already onfile at NAVSUP WSS Mechanicsburg. 3.All contractual documents (i.e. contracts, purchase orders, task orders,delivery orders, and modifications) related to the instant procurement areconsidered to be \"issued\" by the Government when copies are either depositedin the mail, transmitted by facsimile, or sent by other electronic commercemethods such as email. The Government?s acceptance of the contractor?sproposal constitutes bilateral agreement to \"issue\" contractual documents asdetailed herein. 4.Partial and early delivery of requirement is authorized and desired and is at no additional cost to either the vendor or the Government. 5.NAVSUP WSS will be considering past performance in the evaluation of offers.See Clause 252.204-7024. 6.This award will be issued bilaterally, requiring the contractor?s written acceptance prior to execution. 7.This is a rated order certified for national defense use and the Contractor will follow all requirements of the Defense Priorities and Allocations System Regulation (15 CFR 700), see clause 52.211-14. 8. This item requires Oxygen Cleaning and Navy source certification. 9.The following proposed delivery schedule applies:Submission of all certification data CDRLS 20 days prior to delivery.PNSY review/acceptance of certification CDRLS 18 working days after receipt. \\ 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 1.1.1 This ;Pressure Reducing Manifold; contains non-metallic materials which must satisfy the toxicity and flammability requirements of NAVSEA SS800-AG-MAN-010/P-9290. Use of any material other than that specified requires special engineering approval and may require testing. 1.1.2 LI-SOC ITEM - It has been determined that this item falls within both the Level I boundary and the Scope of Certification (SOC) boundary. 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.2.1 Specification Revisions - The specification revisions listed under \"Documents References\" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications...","url":"https://matchawards.com/dept_of_the_navy/posts/115825823396991159","identifier":"N0010426QZA56","category":"332919 - Other Metal Valve and Pipe Fitting Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"4820 - VALVES, NONPOWERED"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.1 Machinery \u0026 Components","url":"https://matchawards.com/categories/industrial-products-and-services/machinery-and-components"}],"availabilityStarts":"2026-08-04","availabilityEnds":"2026-08-28","validThrough":"2026-08-28T23:59:59-04:00","sameAs":"https://sam.gov/workspace/contract/opp/b1dbf5c8ded84b7399b1c84ab7042855/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

