<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_navy/posts/113828916559804972" -->

---
title: LCS Independence Data Acquisition Units (DAU) | Closed - MatchAwards
description: LCS Independence Data Acquisition Units (DAU). United States Department of the Navy. Solicitation N6449825QXXXX. NAICS 334111 - Electronic Computer Manufacturing. Deadline 2025-02-06. THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare...
canonical: https://matchawards.com/dept_of_the_navy/posts/113828916559804972
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: LCS Independence Data Acquisition Units (DAU) | Closed
og:url: https://matchawards.com/dept_of_the_navy/posts/113828916559804972
og:description: LCS Independence Data Acquisition Units (DAU). United States Department of the Navy. Solicitation N6449825QXXXX. NAICS 334111 - Electronic Computer Manufacturing. Deadline 2025-02-06. THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare...
og:image: https://matchawards.com/system/accounts/avatars/000/000/085/original/a0262fe00d6c038b.png?1638992122
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# LCS Independence Data Acquisition Units (DAU)

Status

Closed, the response deadline passed on Feb 6, 2025

Agency

[United States Department of the Navy](/dept%5Fof%5Fthe%5Fnavy)

Office

PHILADELPHIA, USA

Notice type

Sources Sought

Solicitation number

N6449825QXXXX

NAICS

[334111 - Electronic Computer Manufacturing](/groups/501)

PSC

7H20 - IT AND TELECOM - PLATFORM PRODUCTS: DATABASE, MAINFRAME, MIDDLEWARE (HW, PERPETUAL LICENSE SOFTWARE)

Category

[IT Products (1.1)](/categories/information-technology/it-products)

Posted

2025-01-22

Deadline

2025-02-06

Place of performance

Philadelphia, Pennsylvania 19112, UNITED STATES

## Description

THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). The Naval Surface Warfare Center Philadelphia Division (NSWCPD) Navigation Critical Distribution System (NCDS) support team has a requirement for CVN 70 network switch racks. Below are some of the general and form-fit-function (FFF) specific requirements. The Government is seeking all possible solutions/responses to meet this requirement. Responses are sought for existing products that can be modified to fit the Government’s need.\*\*this is not a request for purchase order\*\*

<!-- mobian-agent-ad sponsored="true" id="ad270f4e-ad37-4a63-91f0-fbf8e99fee24" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/information-technology/it-products?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


GENERAL

* Appurtenant equipment to assemble rack and components shall include, but are not limited to, terminal boards, cabling, EMI power filters, labels etc.
* Any COTS software/licenses/technical manuals or other data purchased as part of a component purchase shall be provided to the government.
* All wiring/cabling installed shall be labeled in plain language to identify component being connected – eg “Power A to Core Network Switch PS 1”
* Front and Rear Rack rails shall be tapped (threaded not straight/thru holes).
* Metal hinges shall be used.
* Rack front door and removable side & rear panels shall be lockable.
* The design shall ensure that no components or fiber connectors contact front door or rear/side panels when closed.
* Shock Isolators shall be included on rack assembly (bottom and sway) when delivered.

FFF REQUIREMENTS

Weight: The overall weight of the rack shall not exceed 1000 lbs.

Center of Gravity: Center of Gravity (COG) shall be approximately 26.05 in from the bottom of the rack, 12.11 in from the left side of the rack, and 14.58 in from the front of the rack.

Dimensions: External dimensions, including bolt pattern are critical. The dimensions of the rack, including the shock mounts, sway mounts and rigging bolts, shall be 78.75 in. x 24.06 in. x 37.46 in. (Height x Width x Depth) with a maximum shock excursion of 3.5 in. around the entire perimeter of the rack.

Patch Panels: The racks shall include four (4) total fiber optic patch panels with 48 fiber optic ST couplers per patch panel, allowing for 192 total fiber optic termination points.

Uninterruptible Power Supplies (UPS): The racks must include two (2) Uninterruptible Power Supplies capable of providing uninterrupted power to all components inside the rack for a minimum of 30 minutes in the case of a complete loss of power.

Power Distribution Unit (PDU): Power from UPSs shall be distributed to all internal electrical components via PDUs. Internal rack components having redundant power supplies shall have each power supply fed from a different PDU.

Core Network Switch Requirements: 2 Siemens MX5000 \* **or equivalent**\* switch chassis (MR1),

each having the following module configuration:

Core Switch #1 (Top):

2 AC Power Supplies (MHIF)

1 Control Module (MCM01, L3SEL3HW)

1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)

1 4-port 1000BaseLX Line Module (M4FG03)

4 8-port 100BaseFX Line Modules (M8FX11)

1 16-port 10/100BaseTx Line Module (M16TX01)

Full MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G18+H04+J01

Core Switch #2 (Top):

2 AC Power Supplies (MHIF)

1 Control Module (MCM01, L3SEL3HW)

1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)

1 4-port 1000BaseLX Line Module (M4FG03)

4 8-port 100BaseFX Line Modules (M8FX11)

1 16-port 10/100BaseTx Line Module (M16TX01)

Full MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G18+H04+J01

Each Core Network Switch shall have a minimum of 1U spacing between itself and the rack enclosure or other rack components.

Cable Management Tray:

2U rack height, used to route and cover/store fiber jumper slack

Located below lowest Core Network Switch

Ortronics OR-808044549 or similar.

Rack Mount Sealed PC CPU: The rack-mountable workstations shall adhere to standard Electronics Industries Alliance (EIA) 19 inch rack mounting standards.

Windows 10 or later OS / RHEL 8 or later OS

8GB RAM (threshold), 16 GB RAM (objective)

Minimum 2 RJ45 10/100/1000Base-TX Ethernet ports

Minimum 2x 100Base-FX ports

Minimum of 1 SFP for 1000Base-LX

Minimum 1 SVGA, 1 DVI and 1 DisplayPort or HDMI

Locking front cover with any ports and on/off button covered with common key currently used within US Navy Fleet.

Capable of using installed KVM and display

Sealed – no fans

0-60C operating range minimum.

2x 500GB solid state removable hard drives minimum

USB ports front and rear (qty 2 min front qty 2 rear min)

2U Max Height

Shall be able to be serviced without having to remove from rack.

3.10 Pull Out Keyboard/Trackball/Display:

1U pull out keyboard Trackball and Display for Rack Mount Sealed PC CPU

Must be able to pull out and lock into place and open screen at least to 90degree perpendicular to keyboard.

Modular Master Clock: Brandywine Modular Master Clock \* **or equivalent**\* having the following module configuration:

2 AC Power Supply Modules (033000014)

2 Modular Master Clock Rubidium Oscillator Assemblies (033000004)

2 Modular Master Clock Modules (033000003)

1 Optical Crosslink Module (033000011)

1 NTP Server Module (033000015)

10 Universal Output Signal Modules (033000010)

3.12 Ship Control System (SCS) Network Switch (CVN Configuration Only):

1 Siemens MX5000 switch chassis (MR1), having the following module configuration:

2 AC Power Supplies (MHIF)

1 Control Module (MCM01)

1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70)

6 8-port 100BaseFX Line Modules (M8FX11)

Full MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G04+H04+J04

Environmental Qualification Testing: Network Switch Racks shall meet shock (MIL-DTL-901), vibration (MIL-STD-167), and EMI (MIL-STD-461).

Final rack assembly (including all internal components in their service mounting positions) shall be designed to meet all requirements of the Referenced Documents including vibration, shock, EMC, temperature, humidity, fungus, and inclination. If not previously referenced in this document, the latest revision of the following shall apply as minimum standards:

Shock: MIL-S-901 Grade A

Vibration: MIL-STD-167

EMC: MIL-STD-461

Operating Temperature: 0-50oC (objective) 45 oC (threshold), MIL-STD-810

Non-operating Temperature: -40 - 70oC, MIL-STD-810

Relative Humidity: 10 – 90% non-condensing, MIL-STD-810

Salt fog and fungus: MIL-STD-810

[Source notice](https://sam.gov/opp/5dc7469b70a24ce295e6e15d64fefd5e/view)

[More from United States Department of the Navy posted in January 2025](/dept%5Fof%5Fthe%5Fnavy/archive/2025-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"LCS Independence Data Acquisition Units (DAU)","description":"THIS REQUEST FOR INFORMATION (RFI) NOTICE is being issued by the Department of the Navy, Naval Surface Warfare Center, Philadelphia Division (NSWCPD). The Naval Surface Warfare Center Philadelphia Division (NSWCPD) Navigation Critical Distribution System (NCDS) support team has a requirement for CVN 70 network switch racks. Below are some of the general and form-fit-function (FFF) specific requirements. The Government is seeking all possible solutions/responses to meet this requirement. Responses are sought for existing products that can be modified to fit the Government’s need.**this is not a request for purchase order** GENERAL Appurtenant equipment to assemble rack and components shall include, but are not limited to, terminal boards, cabling, EMI power filters, labels etc. Any COTS software/licenses/technical manuals or other data purchased as part of a component purchase shall be provided to the government. All wiring/cabling installed shall be labeled in plain language to identify component being connected – eg “Power A to Core Network Switch PS 1” Front and Rear Rack rails shall be tapped (threaded not straight/thru holes). Metal hinges shall be used. Rack front door and removable side \u0026 rear panels shall be lockable. The design shall ensure that no components or fiber connectors contact front door or rear/side panels when closed. Shock Isolators shall be included on rack assembly (bottom and sway) when delivered. FFF REQUIREMENTS Weight: The overall weight of the rack shall not exceed 1000 lbs. Center of Gravity: Center of Gravity (COG) shall be approximately 26.05 in from the bottom of the rack, 12.11 in from the left side of the rack, and 14.58 in from the front of the rack. Dimensions: External dimensions, including bolt pattern are critical. The dimensions of the rack, including the shock mounts, sway mounts and rigging bolts, shall be 78.75 in. x 24.06 in. x 37.46 in. (Height x Width x Depth) with a maximum shock excursion of 3.5 in. around the entire perimeter of the rack. Patch Panels: The racks shall include four (4) total fiber optic patch panels with 48 fiber optic ST couplers per patch panel, allowing for 192 total fiber optic termination points. Uninterruptible Power Supplies (UPS): The racks must include two (2) Uninterruptible Power Supplies capable of providing uninterrupted power to all components inside the rack for a minimum of 30 minutes in the case of a complete loss of power. Power Distribution Unit (PDU): Power from UPSs shall be distributed to all internal electrical components via PDUs. Internal rack components having redundant power supplies shall have each power supply fed from a different PDU. Core Network Switch Requirements: 2 Siemens MX5000 * or equivalent * switch chassis (MR1), each having the following module configuration: Core Switch #1 (Top): 2 AC Power Supplies (MHIF) 1 Control Module (MCM01, L3SEL3HW) 1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70) 1 4-port 1000BaseLX Line Module (M4FG03) 4 8-port 100BaseFX Line Modules (M8FX11) 1 16-port 10/100BaseTx Line Module (M16TX01) Full MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G18+H04+J01 Core Switch #2 (Top): 2 AC Power Supplies (MHIF) 1 Control Module (MCM01, L3SEL3HW) 1 Switching Module w/ 2 10GBaseLR Interfaces (MSM70) 1 4-port 1000BaseLX Line Module (M4FG03) 4 8-port 100BaseFX Line Modules (M8FX11) 1 16-port 10/100BaseTx Line Module (M16TX01) Full MX5000 Assy Siemens P/N: 6GK6050-0MM26-6DG1-ZA10+B00+C01+D04+E04+F04+G18+H04+J01 Each Core Network Switch shall have a minimum of 1U spacing between itself and the rack enclosure or other rack components. Cable Management Tray: 2U rack height, used to route and cover/store fiber jumper slack Located below lowest Core Network Switch Ortronics OR-808044549 or similar. Rack Mount Sealed PC CPU: The rack-mountable workstations shall adhere to standard Electronics Industries Alliance (EIA) 19 inch rack mounting standards. Windows 10 or later OS / RHEL 8 or later OS 8GB RAM (threshold), 16 GB RAM (objective) Minimum 2 RJ45 10/100/1000Base-TX Ethernet ports Minimum 2x 100Base-FX ports Minimum of 1 SFP for 1000Base-LX Minimum 1 SVGA, 1 DVI and 1 DisplayPort or HDMI Locking front cover with any ports and on/off button covered with common key currently used within US Navy Fleet. Capable of using installed KVM and display Sealed – no fans 0-60C operating range minimum. 2x 500GB solid state removable hard drives minimum USB ports front and rear (qty 2 min front qty 2 rear min) 2U Max Height Shall be able to be serviced without having to remove from rack. 3.10 Pull Out Keyboard/Trackball/Display: 1U pull out keyboard Trackball and Display for Rack Mount Sealed PC CPU Must be able to pull out and lock into place and open screen at least to 90degree perpendicular to keyboard. Modular Master Clock: Brandywine Modular Master Clock * or equivalent * having the following module configuration: 2 AC Power Supply Modules (033000014) 2 Modular Master Clock...","url":"https://matchawards.com/dept_of_the_navy/posts/113828916559804972","identifier":"N6449825QXXXX","category":"334111 - Electronic Computer Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"7H20 - IT AND TELECOM - PLATFORM PRODUCTS: DATABASE, MAINFRAME, MIDDLEWARE (HW, PERPETUAL LICENSE SOFTWARE)"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"1.1 IT Products","url":"https://matchawards.com/categories/information-technology/it-products"}],"availabilityStarts":"2025-01-22","availabilityEnds":"2025-02-06","validThrough":"2025-02-06T23:59:59-05:00","areaServed":"Philadelphia, Pennsylvania 19112, UNITED STATES","sameAs":"https://sam.gov/opp/5dc7469b70a24ce295e6e15d64fefd5e/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```