<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_navy/posts/107048809280369079" -->

---
title: INDEFINITE-DELIVERY INDEFINITE-QUANTITY ARCHITECT-ENGINEER… | Closed - MatchAwards
description: INDEFINITE-DELIVERY INDEFINITE-QUANTITY ARCHITECT-ENGINEER CONTRACT; MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION; NAVFAC SW. United States Department of the Navy. Solicitation N62473-21-R-1224. NAICS 541330 - Engineering Services. Total small business set-aside. Deadline 2021-10-19....
canonical: https://matchawards.com/dept_of_the_navy/posts/107048809280369079
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: INDEFINITE-DELIVERY INDEFINITE-QUANTITY ARCHITECT-ENGINEER… | Closed
og:url: https://matchawards.com/dept_of_the_navy/posts/107048809280369079
og:description: INDEFINITE-DELIVERY INDEFINITE-QUANTITY ARCHITECT-ENGINEER CONTRACT; MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION; NAVFAC SW. United States Department of the Navy. Solicitation N62473-21-R-1224. NAICS 541330 - Engineering Services. Total small business set-aside. Deadline 2021-10-19....
og:image: https://matchawards.com/system/accounts/avatars/000/000/085/original/a0262fe00d6c038b.png?1638992122
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# INDEFINITE-DELIVERY INDEFINITE-QUANTITY ARCHITECT-ENGINEER CONTRACT; MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION; NAVFAC SW

Status

Closed (archived notice)

Agency

[United States Department of the Navy](/dept%5Fof%5Fthe%5Fnavy)

Office

SAN DIEGO, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

N62473-21-R-1224

NAICS

[541330 - Engineering Services](/groups/897)

PSC

C219 - ARCHITECT AND ENGINEERING- GENERAL: OTHER

Category

[Construction Related Services (4.2)](/categories/facilities-and-construction/construction-related-services)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2021-10-05

Deadline

2021-10-19

Place of performance

San Diego, 92132

## Description

Amendment 01, dated October 5, 2021: The following change is made to the synopsis: Criterion 1Professional Qualifications: Under the Submission Requirements, the section is revised to state that the Program Manager shall be distinct from other roles. The requirement now states: The designated Program Manager shall either be a professionally registered Electrical Engineer or a professionally registered Mechanical Engineer, and be an employee of the prime A-E firm. This position is distinct from that of individuals who are responsible for managing individual task orders/projects under the IDIQ contract or special programs (QC, Sustainable Design, etc.). N62473-21-R-1224 INDEFINITE DELIVERY/INDEFINITE QUANTITY CONTRACT FOR MECHANICAL ENGINEERING, ELECTRICAL ENGINEERING, PLUMBING, AND FIRE PROTECTION ARCHITECT-ENGINEER SERVICES AT VARIOUS MILITARY INSTALLATIONS LOCATED IN THE NAVFAC SOUTHWEST (SW) AREA OF RESPONSIBILITY (AOR): CALIFORNIA, ARIZONA, NEVADA, COLORADO, NEW MEXICO, AND UTAH; BUT MAY BE AVAILABLE WORLDWIDE. Description: ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT A STANDARD FORM SF-330, ARCHITECT ENGINEER QUALIFICATIONS, IS CONTAINED HEREIN. THERE IS NO SEPARATE REQUEST FOR PROPOSALS (RFP) PACKAGE TO DOWNLOAD. THIS IS A SMALL BUSINESS SET-ASIDE. This procurement will result in one Indefinite Delivery/Indefinite Quantity (IDIQ) contract for Mechanical Engineering, Electrical Engineering, Plumbing, and Fire Protection Architect-Engineer (AE) services for various projects at various military installations located in the NAVFAC SW AOR: California, Arizona, Nevada, Colorado, New Mexico, Utah, but may include work worldwide. The preponderance of work is expected to be in Southern California. These services will be procured in accordance with 40 USC Chapter 11, Selection of Architects and Engineers, as implemented by FAR Subpart 36.6\. The IDIQ contract will be for a base period of two (2) years and two (2) three (3)-year option periods, for a total of eight (8) years. The total fee for the contract term shall not exceed $40,000,000\. The guaranteed minimum for the contract term is $5,000\. Firm-fixed price task orders will be negotiated for this contract. The minimum value of individual task orders executed under this contract is $200,000 and the maximum value is $2,500,000\. There will be no dollar limit per year. Multiple task orders may be awarded with similar completion schedules and overlapping delivery dates. Estimated start date is September 2022\. THIS IS A TOTAL SMALL BUSINESS SET-ASIDE PROCUREMENT. The Small Business size standard classification is North American Industrial Classification System (NAICS) Code 541330 (Engineering Services). The Government seeks the most highly qualified firm to perform the required services, based on the demonstrated competence and qualifications, in accordance with the selection criteria. The Offeror/Contractor must demonstrate adequate in-house staffing capable to self-perform at least 50 percent of the cost of the contract as required by FAR Clause 52.219-14 (b)(1) Limitations on Subcontracting (MAR 2020). A market research study was conducted by NAVFAC SW that included an assessment of relevant qualifications and capabilities of potentially qualified firms. Upon review of the market research, the U.S. Small Business Administration (SBA) in San Diego determined that a Small Business Set-Aside procurement is appropriate. The NAVFAC SW small business office concurs with the SBA determination. A-E services required: a. PRIMARY SERVICES: Preparation of Requests for Proposals (RFP) for Design Build (DB) projects; Design-Bid-Build (DBB) construction contract packages (i.e., full plans and specifications); Mechanical/Electrical Site Investigations, Studies, Surveys, and Reports. b. SECONDARY SERVICES: Cost estimates; construction contract support services (CCSS) or post construction award services (PCAS); Fire Protection Engineering Designs, Studies, Surveys and Site Investigation (e.g. fire risk/hazard analysis, life safety code analysis, fire modeling and engineering documentation, antiterrorism, and final inspections and tests of installed Fire Protection Systems. Fire Protection surveys shall be conducted within the guidelines established by OPNAVINST 11320.23G. c. SUPPORT SERVICES WHICH MAY BE REQUIRED: Technical reviews of government-prepared RFP for DB projects and/or full plans and specifications for DBB projects; preparation of planning and programming support documents (such as DD1391 documents); incidental architectural, civil, structural, geotechnical, and environmental work; identification and abatement methods for existing asbestos-containing materials, lead-based paint, and other hazardous materials. Types of projects will include, but are not limited to, sustainable energy documentation (e.g. Energy Master Planning, Commissioning, Life Cycle Cost, LEED/Third Party Certifications, Title 24 Energy Compliance documents, ASHRAE 90.1 compliance documents, and ASHRAE 90.1 Performance Rating Method reports); Military Construction (MILCON), new construction, major repair/renovation of: onsite power generating systems (e.g. solar, cogeneration); control systems (e.g. microgrid, utility control systems); heating, ventilation, air conditioning and control systems (e.g. exhaust systems, direct digital control schematic and architecture); energy supply systems (i.e. above and below ground steam distribution, high temperature/pressure water, refrigeration systems, and natural gas including earthquake shut off valves); plumbing systems; interior and exterior electrical power systems (e.g. interior building power, medium and low voltage distribution systems, primary and secondary substations, Uninterruptable Power Supply (UPS), emergency generators); communication and security systems (e.g. cable TV, electronic security systems); fire protection systems (e.g. fire sprinklers, fire alarm and detection systems, fire alarms and fire resistant building assemblies); and lighting systems for airfield, operational and training, commercial, institutional, industrial, research development, quality of life facilities, etc. All contractors are advised that registration in System for Award Management (SAM) Database is required prior to award of a contract. Failure to register in the SAM Database may render your firm ineligible for award. For more information, check the SAM Web site: https://www.sam.gov. The Special Contracts Requirement section of the contract will contain the following contract language addressing organizational conflicts of interest: Review of FAR Subpart 9.5, Organizational and Consultant Conflicts of Interest is encouraged. The intent is to identify and evaluate potential conflicts of interest prior to contract award. Generally, if the Contractor/affiliates/subcontractors under this contract prepares or assists in preparing a statement of work, specifications and plans, the Contractor and its affiliates and any subcontractors/subconsultants may be ineligible to bid or participate, in any capacity, in any contractual effort which is based on such statement of work or specifications and plans as a prime contractor, subcontractor, consultant or in any similar capacity. In addition, the Contractor and its affiliates and/or subcontractors under this contract are ineligible to bid or participate, in any capacity, in any contractual effort which is based upon a statement of work, specifications and plans which the Contractor and its affiliates and/or subcontractors previously prepared or assisted in preparing. The prime firm for this contract will be required to perform throughout the contract term. Interviews may be scheduled with firms slated as the most highly qualified. Firms slated for interviews may be asked to clarify information contained in the SF-330 submittal. Elaborate presentations are not desired. SELECTION CRITERIA: Firms responding to this synopsis will be evaluated to determine the most highly qualified firms to perform the required services in accordance with the published selection criteria. Failure to comply with instructions, or provide complete information may affect the firms evaluation or disqualify the firm from further consideration. Criteria 1 and 2 are considered most important and of equal importance to each other; Criteria 3, 4, and 5 are of lesser importance and listed in descending order of importance; and Criterion 6 is of lesser importance and will be used as a tiebreaker among firms considered to be technically equal. Evaluation of past performance and experience may include information provided by the firm, customer inquiries, Government databases, and publicly available sources. Failure to provide requested data, accessible points of contact, or valid phone numbers may result in a firm being considered less favorably in the evaluation. Specific selection criteria include: 1\. Professional Qualifications 2\. Specialized Experience & Technical Competence 3\. Past Performance 4\. Quality Control 5\. Program Management, Capacity, and Location 6\. Volume of Work Criterion 1Professional Qualifications (SF330, Part I, Sections E & G): Firms will be evaluated on professional qualifications, competence, and experience of the proposed key personnel in providing services to accomplish the tasks required under this contract, including participation in example projects in the SF-330, Part I, Section F. Key personnel are individuals who will have major contract or project management responsibilities and/or will provide specialized expertise. All key personnel must be professionally registered/accredited (see definition) in their discipline. Specific disciplines that must be included in key personnel are: the Program Manager; Quality Control Managers; and professionally registered Electrical Engineers, Mechanical Engineers, and Fire Protection Engineer. Provide additional Project or Task Order Managers and Engineers, as applicable. Key personnel demonstrating experience with projects located at Navy and Marine Corps military installations may be considered more favorably in the evaluation. Firms that have both the Mechanical and Electrical Quality Control Managers as part of the Prime A-E firm may be considered more favorably. All key personnel must include the state where registration was issued, registration number, expiration date of registration, and geographic office location for each proposed key personnel member. Key personnel not providing mechanical, electrical, or fire protection engineering services will not be evaluated. Submission Requirements: SF-330, Part I, Section E. Provide resumes for all proposed key personnel that illustrate experience in the A-E services for the relevant project types proposed under this contract. Non-relevant information will not be considered. Resumes of personnel performing only support services (as listed in this contract) are not required and will not be considered. The designated Program Manager shall either be a professionally registered Electrical Engineer or a professionally registered Mechanical Engineer, and be an employee of the prime A-E firm. This position is distinct from that of individuals who are responsible for managing individual task orders/projects under the IDIQ contract or special programs (QC, Sustainable Design, etc.). Provide one (1) designated Quality Control Manager that is a professionally registered Electrical Engineer and one (1) designated Quality Control Manager that is a professionally registered Mechanical Engineer. At least one (1) of the designated Quality Control Managers shall be an employee of the prime A-E firm. The prime A-E firm shall have a minimum of one (1) professionally registered Electrical Engineer on staff and one (1) professionally registered Mechanical Engineer on staff, in addition to the Program Manager, to perform the anticipated work of this contract. In addition, provide at least one (1) registered professional Fire Protection Engineer. See definitions at the end of this notice for professional registration and experience requirements. Resumes of key personnel shall demonstrate their depth of experience in their respective roles. Each resume shall include a maximum of five (5) specific relevant projects and should indicate: professional registration, certification, licensure and/or accreditation in appropriate disciplines; cite recent (within the past five (5) years immediately preceding the date of issuance of this notice) and complete projects (see definition) - that exhibit specific experience in work relevant to the A-E services required under this contract; and indicate proposed role and responsibility in this contract. Identifying only the individuals job title will not provide sufficient information to determine their specific experience as it relates to services to be performed under this contract. Submit a copy of the applicable current professional certification/registration/accreditation certificate (personnel with registration in multiple states need only submit a copy from one state). Projects not meeting these requirements will not be considered. Indicate participation of key personnel in example projects in the SF-330, Part I, Section G. Criterion 2 Specialized Experience & Technical Competence (SF-330, Part I, Section F): Firms will be evaluated on specialized experience in performance of services similar to those anticipated under this contract through evaluation of experience in: The proposed teams experience and technical competence in the primary and secondary A-E services for project types identified for this contract. Experience applying sustainability concepts through an integrated, cost effective design approach and designing in accordance with recognized sustainability rating systems such as Green Globe, LEED, etc. Firms may be considered more favorably by demonstrating the following: Offeror demonstrating a depth of relevant experience with the primary and secondary engineering services expected for this contract. Offeror demonstrating a depth of self-performed relevant experience with both mechanical and electrical projects expected for this contract. Submission requirements: Provide a maximum of ten (10) completed projects (see definitions) within the past five (5) years immediately preceding the date of issuance of this notice that best demonstrate specialized experience of the proposed team in performing the primary and secondary A-E services for project types identified for this contract. Projects providing only PCAS experience will not be considered. Sufficient information to determine the date of completion of the project must be included in the project description or the project will not be considered. All relevant projects shall have a professional fee of $250,000 or more. If more than ten (10) projects are submitted, the Government will only evaluate the first ten (10) projects in the order submitted. Additional requirements: A minimum of one (1) project shall demonstrate relevant experience with projects having professional fees of $500,000 or greater. A minimum of one (1) project shall demonstrate relevant self-performed (see definition) experience with the preparation of a Request for Proposal for Design-Build for a new building HVAC system or the renovation/repair of an existing HVAC system. A minimum of one (1) project shall demonstrate relevant self-performed (see definition) Design-Bid-Build experience (i.e. full plans and specs, not just PCAS services) of a mechanical system. A minimum of one (1) project shall demonstrate relevant experience with the preparation of a Request for Proposal for Design-Build or with the design (i.e. full plans and specs, not just PCAS services) for each of the following: Exterior electrical power system with a minimum of 15kV (i.e., overhead and underground distribution systems, primary and secondary substations, emergency generators, etc.) Fire protection system and life safety features for a facility. Note: A single project may satisfy more than one of the above minimum requirements. All projects provided in the SF-330 must be completed by the actual office/branch/regional office/individual team member proposed to manage and perform work under this contract identified in SF-330, Part I, Section C. Projects not meeting this requirement will be excluded from consideration in the evaluation. To enable verification, firms should include the DUNS number along with each firm name in the SF-330 Part I, Section F, block 25, Firm Name. Include a contract number or project identification number in block 21\. Include the month and year of completion in block 22\. Include an e-mail address and phone number for the point of contact in block 23(c). In block 24, include in the project description the type of project and its relevance to the scope of this contract, the contract period of performance, award contract value, current contract value, relevant sustainable features incorporated in the project, and a summary of the work performed that demonstrates relevance to specialized experience as outlined above. Firms with multiple offices shall indicate which office/branch performed the A-E services. For projects performed as a subcontractor or a joint venture involving different partners, specifically indicate the value of the work performed as a subcontractor or by those firms proposed for this contract, and identify the specific roles and responsibilities performed as a subcontractor or by those firms on the project rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project could be eliminated from consideration. NOTE: If the firm is a joint venture, projects performed by the joint venture should be submitted; however, if there are no projects performed by the joint venture, projects must be submitted for each joint venture partner, not to exceed the ten (10) project limitation. Firms failing to provide projects from all joint venture partners will be considered to have not met the requirements of the criterion. In cases where the submitted project was performed by a JV, but all JV partners for that project are not on the team identified in Part I, Section C, specifically describe the relevant work performed by the JV partner(s) proposed for this contract. Projects shall be submitted on the SF-330 at Part I, Section F and shall be completed projects. Projects not completed will be excluded from evaluation consideration. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award. Do not submit an IDIQ contract as an example project. Instead, submit a relevant task order or stand-alone contract award that fits within the definition above. The Government will not evaluate information provided for an IDIQ contract. Examples of project work submitted that do not conform to this requirement will not be evaluated. All information for Criterion 2 should be submitted in the SF-330, Part I, Section F. The Government WILL NOT consider information submitted in addition to Part I, Section F in evaluation of Criterion 2\. Criterion 3Past Performance (SF330, Part I, Section H): Firms will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided in Past Performance Questionnaires (PPQs) or CPARS/ACASS for Criterion 2 projects and may include customer inquiries, Government databases, and other information available to the Government including contact with points of contact in other criteria. NOTE: Past performance information for projects listed under Criterion 2 may be given greater weight. Submission 

<!-- mobian-agent-ad sponsored="true" id="3ceb77a3-e758-41ff-9f07-8bc89fdb4d35" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/construction-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541330/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/36422bfa59ab43f3a40d0933fc8505bb/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/579a384edd964938b58b345811639dbb/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c6913601934f4cbabb43821704f94ca1/download)
* [Attachment 4](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8a86704311734b9f96efbe16a432191a/download)
* [Attachment 5](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f56d8309eb404a149cdfc59daad45df3/download)
* [Attachment 6](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7566d6737ad446ec9f7ddb2f344852b1/download)

## Contacts

* Mary Grace Cortez
* Harold W. Hayes

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/071bd9dee7a243749cba03ab9b8edf6e/view)

[More from United States Department of the Navy posted in October 2021](/dept%5Fof%5Fthe%5Fnavy/archive/2021-10)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541330](/naics/541330/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"INDEFINITE-DELIVERY INDEFINITE-QUANTITY ARCHITECT-ENGINEER CONTRACT; MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION; NAVFAC SW","description":"Amendment 01, dated October 5, 2021: The following change is made to the synopsis: Criterion 1Professional Qualifications: Under the Submission Requirements, the section is revised to state that the Program Manager shall be distinct from other roles. The requirement now states: The designated Program Manager shall either be a professionally registered Electrical Engineer or a professionally registered Mechanical Engineer, and be an employee of the prime A-E firm. This position is distinct from that of individuals who are responsible for managing individual task orders/projects under the IDIQ contract or special programs (QC, Sustainable Design, etc.). N62473-21-R-1224 INDEFINITE DELIVERY/INDEFINITE QUANTITY CONTRACT FOR MECHANICAL ENGINEERING, ELECTRICAL ENGINEERING, PLUMBING, AND FIRE PROTECTION ARCHITECT-ENGINEER SERVICES AT VARIOUS MILITARY INSTALLATIONS LOCATED IN THE NAVFAC SOUTHWEST (SW) AREA OF RESPONSIBILITY (AOR): CALIFORNIA, ARIZONA, NEVADA, COLORADO, NEW MEXICO, AND UTAH; BUT MAY BE AVAILABLE WORLDWIDE. Description: ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT A STANDARD FORM SF-330, ARCHITECT ENGINEER QUALIFICATIONS, IS CONTAINED HEREIN. THERE IS NO SEPARATE REQUEST FOR PROPOSALS (RFP) PACKAGE TO DOWNLOAD. THIS IS A SMALL BUSINESS SET-ASIDE. This procurement will result in one Indefinite Delivery/Indefinite Quantity (IDIQ) contract for Mechanical Engineering, Electrical Engineering, Plumbing, and Fire Protection Architect-Engineer (AE) services for various projects at various military installations located in the NAVFAC SW AOR: California, Arizona, Nevada, Colorado, New Mexico, Utah, but may include work worldwide. The preponderance of work is expected to be in Southern California. These services will be procured in accordance with 40 USC Chapter 11, Selection of Architects and Engineers, as implemented by FAR Subpart 36.6. The IDIQ contract will be for a base period of two (2) years and two (2) three (3)-year option periods, for a total of eight (8) years. The total fee for the contract term shall not exceed $40,000,000. The guaranteed minimum for the contract term is $5,000. Firm-fixed price task orders will be negotiated for this contract. The minimum value of individual task orders executed under this contract is $200,000 and the maximum value is $2,500,000. There will be no dollar limit per year. Multiple task orders may be awarded with similar completion schedules and overlapping delivery dates. Estimated start date is September 2022. THIS IS A TOTAL SMALL BUSINESS SET-ASIDE PROCUREMENT. The Small Business size standard classification is North American Industrial Classification System (NAICS) Code 541330 (Engineering Services). The Government seeks the most highly qualified firm to perform the required services, based on the demonstrated competence and qualifications, in accordance with the selection criteria. The Offeror/Contractor must demonstrate adequate in-house staffing capable to self-perform at least 50 percent of the cost of the contract as required by FAR Clause 52.219-14 (b)(1) Limitations on Subcontracting (MAR 2020). A market research study was conducted by NAVFAC SW that included an assessment of relevant qualifications and capabilities of potentially qualified firms. Upon review of the market research, the U.S. Small Business Administration (SBA) in San Diego determined that a Small Business Set-Aside procurement is appropriate. The NAVFAC SW small business office concurs with the SBA determination. A-E services required: a. PRIMARY SERVICES: Preparation of Requests for Proposals (RFP) for Design Build (DB) projects; Design-Bid-Build (DBB) construction contract packages (i.e., full plans and specifications); Mechanical/Electrical Site Investigations, Studies, Surveys, and Reports. b. SECONDARY SERVICES: Cost estimates; construction contract support services (CCSS) or post construction award services (PCAS); Fire Protection Engineering Designs, Studies, Surveys and Site Investigation (e.g. fire risk/hazard analysis, life safety code analysis, fire modeling and engineering documentation, antiterrorism, and final inspections and tests of installed Fire Protection Systems. Fire Protection surveys shall be conducted within the guidelines established by OPNAVINST 11320.23G. c. SUPPORT SERVICES WHICH MAY BE REQUIRED: Technical reviews of government-prepared RFP for DB projects and/or full plans and specifications for DBB projects; preparation of planning and programming support documents (such as DD1391 documents); incidental architectural, civil, structural, geotechnical, and environmental work; identification and abatement methods for existing asbestos-containing materials, lead-based paint, and other hazardous materials. Types of projects will include, but are not limited to, sustainable energy documentation (e.g. Energy Master Planning, Commissioning, Life Cycle Cost, LEED/Third Party Certifications, Title 24 Energy Compliance documents, ASHRAE 90.1 compliance...","url":"https://matchawards.com/dept_of_the_navy/posts/107048809280369079","identifier":"N62473-21-R-1224","category":"541330 - Engineering Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"C219 - ARCHITECT AND ENGINEERING- GENERAL: OTHER"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.2 Construction Related Services","url":"https://matchawards.com/categories/facilities-and-construction/construction-related-services"}],"availabilityStarts":"2021-10-05","availabilityEnds":"2021-10-19","areaServed":"San Diego, 92132","sameAs":"https://sam.gov/opp/071bd9dee7a243749cba03ab9b8edf6e/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```

