<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_navy/posts/105616244743204389" -->

---
title: Mobile Test Enclosure (MTE) | Closed - MatchAwards
description: Mobile Test Enclosure (MTE). United States Department of the Navy. Solicitation N6660421Q0037. NAICS 332439 - Other Metal Container Manufacturing. Total small business set-aside. Deadline 2021-01-29. Amendment 001: The purpose of this amendment is to update the RFQ attachment with the correct...
canonical: https://matchawards.com/dept_of_the_navy/posts/105616244743204389
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Mobile Test Enclosure (MTE) | Closed
og:url: https://matchawards.com/dept_of_the_navy/posts/105616244743204389
og:description: Mobile Test Enclosure (MTE). United States Department of the Navy. Solicitation N6660421Q0037. NAICS 332439 - Other Metal Container Manufacturing. Total small business set-aside. Deadline 2021-01-29. Amendment 001: The purpose of this amendment is to update the RFQ attachment with the correct...
og:image: https://matchawards.com/system/accounts/avatars/000/000/085/original/a0262fe00d6c038b.png?1638992122
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Mobile Test Enclosure (MTE)

Status

Closed (archived notice)

Agency

[United States Department of the Navy](/dept%5Fof%5Fthe%5Fnavy)

Office

NEWPORT, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

N6660421Q0037

NAICS

[332439 - Other Metal Container Manufacturing](/groups/442)

PSC

8145 - SPECIALIZED SHIPPING AND STORAGE CONTAINERS

Category

[Package Delivery & Packaging (7.1)](/categories/transportation-and-logistics-services/package-delivery-and-packaging)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2021-01-25

Deadline

2021-01-29

## Description

Amendment 001: The purpose of this amendment is to update the RFQ attachment with the correct total small business set-aside restriction. Amendment 002: The purpose of this amendment is to answer questions from industry. Q1: Would you please reconsider the alternative dimensions with all layout requirements such as: 8x24 ft = 192 sf, 8x30 ft = 240 sf, or 16x20 ft = 320 sf. A1: The Container must be 20x10x8.5 due to the equipment racks and ergonomic work space. Q2:, It appears that the customer is seeking a CSC certified container with dimensions of 10ft in width. ISO 668 and ISO 1496 only specify containers up to 8ft width. The drawing shows a 10ft wide container, so it is assumed that this dimension is necessary to meet the mission objective. With that being said, it is in our opinion that a CSC certification cannot be achieved for this dimension. Is this something that the customer would consider waiving? A2: The vendor has the choice to: - Modify a 20ft x 8ft x 8.5ft ISO/CSC certified container to a 10ft width. (All pre-modification certification documentation shall be retained and delivered with the container.) or - In lieu modifying a standard ISO container, the MTE may be constructed new and shall meet all requirements of the specification. Either way, if it's modified or built new, the vendor shall meet all requirements of the specification, i.e., American Bureau of Shipping , USCG regulations, etc. Amendment 003: The purpose of this amendment is to answer questions from industry. Q3: A 10' wide shelter is not a standard ISO container size. At this width, it no longer falls under ABS- CSC/ISO and cannot be CSC tested/CSC Certified stateside to this width. Therefore, CSC/ISO regulations will not permit the original CSC plate to be put back onto the container after it has been modified to this width. Can you please remove or adjust this requirement? A3: The CSC plate shall be removed from the container to permit sandblasting and painting, retained, and submitted with all prior ISO/CSC certification documentation with delivery. Q4: Please further explain the requirement for "Rounded ISO Corners". Are you referring to the corner radius of the standard casting? A4: Yes. Q5: Does the reference to USCG regulations encompass PAM requirements? Refer again to the point made in question 3 noting that a 10' Wide shelter does not fall under ABS-CSC/ISO regulations? A5: Yes. Please see the answer to question 2 (above). Amendment 004: The purpose of this amendment is to answer a question from industry, add Government Furnished Information as an attachment, set a cutoff date for asking questions, and extend the RFQ closing date. Q6\. I wanted to convey that PAM has nothing to do with the Standard ISO/CSC Certification that standard shipping containers are built and tested to. They are 2 completely different requirements A6: Yes, PAM and ISO/CSC are two different requirements. The PAM is an ABS guideline. ISO/CSC is a certification. All paragraphs in the SOW shall be adhered to in accordance with Applicable Documents which include ABS guidelines and USCG standards. The PAM is an ABS Guide. Government Furnished Information is added as attachment 710302542-00\. The Cutoff date for asking questions is 21-JAN-2021\. The RFQ closing date is extended until 26-JAN-2021\. Amendment 005: The purpose of this amendment is to answer a question from industry, add additional specification requirements, add Government Furnished Information as attachments, set a new cutoff date for asking questions, and extend the RFQ closing date. Q7: I am removing the roof top D-rings and installing collapsible safety rail in the open areas. The roof top platform will be open (No railing) A7: No D-rings required. A collapsible safety railing is required on the roof so that nobody falls off. Q8: May I please have a separate drawing for layout so that I can make sure that all the receptacles are included properly. A8: Please see Figure A-1 in the SOW. Q9: May I please have the separate electrical schematic drawing A9: Electrical schematic drawing is added to the SOW as Figure 4\. The following specifications are added to the SOW (page 8): Multi-cable Bulkhead Transit The enclosure shall be outfitted with modular multi-cable bulkhead transit penetrations at each corner, installed 6" below the interior ceiling and at least 6" away from any adjacent bulkhead, and recessed 3". The cable modules shall be integral to the penetration, adaptable to user required diameter fitting, and reconfigurable to future requirements.The location is shown on the Fig A-1 Government Furnished Information is added as attachment One Line Elect. The Cutoff date for asking questions is 28-JAN-2021\. The RFQ closing date is extended until 29-JAN-2021\. See attachments 

<!-- mobian-agent-ad sponsored="true" id="d69d55c5-1e0d-4443-a96a-e2b4d10d1b69" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/transportation-and-logistics-services/package-delivery-and-packaging?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d2b9f2adddff4afb89cd8471d55ef661/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/c37f853bb6d8433fbf3e861b2d185697/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cae1d590108741578e16338d9e04e848/download)
* [Attachment 4](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d15a514f2d10451a86850ff4d36a91ce/download)
* [Attachment 5](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/168210e43df04776ba94cb100f8eb28f/download)
* [Attachment 6](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9ac432e082ad4db0b6cc5720e6e9ec00/download)

## Contacts

* Nicholas P Sanginario

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/111caeb80ddc4a6394ed4ed011a5c7fd/view)

[More from United States Department of the Navy posted in January 2021](/dept%5Fof%5Fthe%5Fnavy/archive/2021-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Mobile Test Enclosure (MTE)","description":"Amendment 001: The purpose of this amendment is to update the RFQ attachment with the correct total small business set-aside restriction. Amendment 002: The purpose of this amendment is to answer questions from industry. Q1: Would you please reconsider the alternative dimensions with all layout requirements such as: 8x24 ft = 192 sf, 8x30 ft = 240 sf, or 16x20 ft = 320 sf. A1: The Container must be 20x10x8.5 due to the equipment racks and ergonomic work space. Q2:, It appears that the customer is seeking a CSC certified container with dimensions of 10ft in width. ISO 668 and ISO 1496 only specify containers up to 8ft width. The drawing shows a 10ft wide container, so it is assumed that this dimension is necessary to meet the mission objective. With that being said, it is in our opinion that a CSC certification cannot be achieved for this dimension. Is this something that the customer would consider waiving? A2: The vendor has the choice to: - Modify a 20ft x 8ft x 8.5ft ISO/CSC certified container to a 10ft width. (All pre-modification certification documentation shall be retained and delivered with the container.) or - In lieu modifying a standard ISO container, the MTE may be constructed new and shall meet all requirements of the specification. Either way, if it's modified or built new, the vendor shall meet all requirements of the specification, i.e., American Bureau of Shipping , USCG regulations, etc. Amendment 003: The purpose of this amendment is to answer questions from industry. Q3: A 10' wide shelter is not a standard ISO container size. At this width, it no longer falls under ABS- CSC/ISO and cannot be CSC tested/CSC Certified stateside to this width. Therefore, CSC/ISO regulations will not permit the original CSC plate to be put back onto the container after it has been modified to this width. Can you please remove or adjust this requirement? A3: The CSC plate shall be removed from the container to permit sandblasting and painting, retained, and submitted with all prior ISO/CSC certification documentation with delivery. Q4: Please further explain the requirement for \"Rounded ISO Corners\". Are you referring to the corner radius of the standard casting? A4: Yes. Q5: Does the reference to USCG regulations encompass PAM requirements? Refer again to the point made in question 3 noting that a 10' Wide shelter does not fall under ABS-CSC/ISO regulations? A5: Yes. Please see the answer to question 2 (above). Amendment 004: The purpose of this amendment is to answer a question from industry, add Government Furnished Information as an attachment, set a cutoff date for asking questions, and extend the RFQ closing date. Q6. I wanted to convey that PAM has nothing to do with the Standard ISO/CSC Certification that standard shipping containers are built and tested to. They are 2 completely different requirements A6: Yes, PAM and ISO/CSC are two different requirements. The PAM is an ABS guideline. ISO/CSC is a certification. All paragraphs in the SOW shall be adhered to in accordance with Applicable Documents which include ABS guidelines and USCG standards. The PAM is an ABS Guide. Government Furnished Information is added as attachment 710302542-00. The Cutoff date for asking questions is 21-JAN-2021. The RFQ closing date is extended until 26-JAN-2021. Amendment 005: The purpose of this amendment is to answer a question from industry, add additional specification requirements, add Government Furnished Information as attachments, set a new cutoff date for asking questions, and extend the RFQ closing date. Q7: I am removing the roof top D-rings and installing collapsible safety rail in the open areas. The roof top platform will be open (No railing) A7: No D-rings required. A collapsible safety railing is required on the roof so that nobody falls off. Q8: May I please have a separate drawing for layout so that I can make sure that all the receptacles are included properly. A8: Please see Figure A-1 in the SOW. Q9: May I please have the separate electrical schematic drawing A9: Electrical schematic drawing is added to the SOW as Figure 4. The following specifications are added to the SOW (page 8): Multi-cable Bulkhead Transit The enclosure shall be outfitted with modular multi-cable bulkhead transit penetrations at each corner, installed 6\" below the interior ceiling and at least 6\" away from any adjacent bulkhead, and recessed 3\". The cable modules shall be integral to the penetration, adaptable to user required diameter fitting, and reconfigurable to future requirements.The location is shown on the Fig A-1 Government Furnished Information is added as attachment One Line Elect. The Cutoff date for asking questions is 28-JAN-2021. The RFQ closing date is extended until 29-JAN-2021. See attachments","url":"https://matchawards.com/dept_of_the_navy/posts/105616244743204389","identifier":"N6660421Q0037","category":"332439 - Other Metal Container Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"8145 - SPECIALIZED SHIPPING AND STORAGE CONTAINERS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"7.1 Package Delivery \u0026 Packaging","url":"https://matchawards.com/categories/transportation-and-logistics-services/package-delivery-and-packaging"}],"availabilityStarts":"2021-01-25","availabilityEnds":"2021-01-29","sameAs":"https://sam.gov/opp/111caeb80ddc4a6394ed4ed011a5c7fd/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```