36--CHLORINATOR, ECG, IN REPAIR/MODIFICATION OF
- Status
- Closed (archived notice)
- Agency
- United States Department of the Navy
- Office
- MECHANICSBURG, USA
- Notice type
- Solicitation
- Solicitation number
- N0010421RFA20
- NAICS
- 333999 - All Other Miscellaneous General Purpose Machinery Manufacturing
- PSC
- 3655 - GAS GENERATING AND DISPENSING SYSTEMS, FIXED OR MOBILE
- Category
- Machinery & Components (5.1)
- Posted
- 2020-10-21
- Deadline
- 2020-11-04
Description
ITEM UNIQUE IDENTIFICATION AND VALUATION (MAR 2016)|19|||||||||||||||||||| HIGHER-LEVEL CONTRACT QUALITY REQUIREMENT (NAVICP REVIEW FEB 1991)(FEB 1999)|1|See section C and E| INSPECTION OF SUPPLIES--FIXED-PRICE (AUG 1996)|2||| TIME OF DELIVERY (JUNE 1997)|20||||||||||||||||||||| STOP-WORK ORDER (AUG 1989)|1|| GENERAL INFORMATION-FOB-DESTINATION|1|B| WIDE AREA WORKFLOW PAYMENT INSTRUCTIONS (DEC 2018)|16|COMBO (INVOICE & RECEIVING)|N/A|TBD|N00104|TBD|TBD|Q92246 |TBD|N/A|N/A|TBD|||||| NAVY USE OF ABILITYONE SUPPORT CONTRACTOR - RELEASE OF OFFEROR INFORMATION (3-18))|1|| EQUAL OPPORTUNITY (SEP 2016)|2||| SMALL BUSINESS SUBCONTRACTING PLAN (DOD CONTRACTS)- BASIC (DEC 2019)|2||| INTEGRITY OF UNIT PRICES (JUN 2020)|1|| EQUAL OPPORTUNITY FOR VETERANS (JUN 2020)|4||||| SMALL BUSINESS SUBCONTRACTING PLAN (AUG 2017) (DEVIATION 2018-O0018)|5|||||TIANA.HAMMAKER@NAVY.MIL| SAFEGUARDING SENSITIVE CONVENTIONAL ARMS, AMMUNITION, AND EXPLOSIVES (SEP 1999))|9|||||||||| EQUAL OPPORTUNITY FOR WORKERS WITH DISABILITIES (JUN 2020)|2||| TRANSPORTATION OF SUPPLIES BY SEA (FEB 2019)|2||| BUY AMERICAN --FREE TRADE AGREEMENTS--BALANCE OF PAYMENTS PROGRAM - BASIC(DEVIATION 2020-O0019) (JUL 2020))|3|||| LIST OF AWARD ATTACHMENTS|5|||||| ALTERNATE A, ANNUAL REPRESENTATIONS AND CERTIFICATIONS (APR 2020)|13|||||||||||||| BUY AMERICAN-FREE TRADE AGREEMENTS-BALANCE OF PAYMENTS PROGRAM CERTIFICATE (DEVIATION 2020-O0019) (JUL 2020))|3|||| BUY AMERICAN-BALANCE OF PAYMENTS PROGRAM CERTIFICATE-BASIC (NOV 2014)|1|| ANNUAL REPRESENTATIONS AND CERTIFICATIONS (MAR 2020)|13|333999|500|||||||||||| TYPE OF CONTRACT (APR 1984)|1|FIRM-FIXED PRICE| NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY PERPARDENESS, AND ENRGY PROGAM USE (APRIL 2008))|2||X| 1. This is a repair requirement. 2. DD1423 Data Item A001 (Inspection and Test Plan) may be waived if already on file at NAVSUP WSS Mechanicsburg. 3. All contractual documents (i.e. contracts, purchase orders, task orders, delivery orders, and modifications) related to the instant procurement are considered to be "issued" by the Government when copies are either deposited in the mail, transmitted by facsimile, or sent by other electronic commerce methods, such as email. The Government's acceptance of the contractor's proposal constitutes bilateral agreement to "issue" contractual documents as detailed here in. 4. Quote shall Be Not to exceed or Firm Fixed Price.A beyond repair (BR)/ beyond economic repair (BER) price shall also be provided in addition to the repair price at time of quoting. 5. Government will be providing NSN 7HH 3655 014582462 Q4, quantity 4. 6. This requirement falls under the Special Emergency Procurement Authority (SEPA) in accordance with 41 U.S.C. 1903 and Class Deviation 2018-O0013. 7. Order will be issued under Basic Ordering Agreement N00104-15-GA4091043. 1. SCOPE 1.1 The material covered in this contract/purchase order will be used in a crucial shipboard system. The use of incorrect or defective material would create a high probability of failure resulting in serious personnel injury, loss of life, loss of vital shipboard systems, or loss of the ship itself. Therefore, the material has been designated as SPECIAL EMPHASIS material (Level I, Scope of Certification, or Quality Assured) and special control procedures are invoked to ensure receipt of correct material. 1.2 ;ECG Refurbish kit, NSN 1H 3655-01-633-0242 will be supplied to HAMILTON SUNDSTRAND CORP.; 1.3 ;ECG Refurbish kit, NSN 1H 3655-01-633-0242 will be supplied to HAMILTON SUNDSTRAND CORP.; 2. APPLICABLE DOCUMENTS 2.1 Order of Precedence - In the event of a conflict between the text of this contract/purchase order and the references and/or drawings cited herein, the text of this contract/purchase order must take precedence. Nothing in this contract/purchase order, however, must supersede applicable laws and regulations unless a specific exemption has been obtained. 2.2 Applicable Documents - The document(s) listed below form a part of this contract/purchase order including modifications or exclusions. 2.3 Specification Revisions - The specification revisions listed under "Docu ments References" below are the preferred revision. Older and/or newer r evisions are acceptable when listed within Contract Support Library Reference Number CSD155 in ECDS (Electric Contractor Data Submission) at: ht tps://register.nslc.navy.mil/. This is to allow Contractors to use certain acceptable older specification revisions to purge their existing stock of material certified to those older revisions or to use newer specification revisions when material is certified to newly released revisions,without requiring the submittal of waiver/deviation requests for each specification revision on every contract. Revisions of specifications reflecting editorial and/or re-approval (e.g. E2009, R2014, etc.) are considered inconsequential, but are acceptable when their revisions are listedwithin CSD155 or elsewhere within this contract. 2.3.1 Documents, drawings, and publications supplied are listed under "Drawing Number". These items should be retained until an award is made. 2.3.2 The documents and drawings listed below under DRAWING NO. are not provided with this Contract/Purchase order. DRAWING NO CAGE REV DISTR CD ;SV799150 73030 T B SV799119 73030 N B SV799133 73030 P B SV799124 73030 H B SV799128 73030 E B SV799129 73030 K B SV799130 73030 H B SV799125 73030 H B SV799127 73030 K B SVHS13255 73030 C B ; 2.3.3 "Document References" listed below must be obtained by the Contractor. Ordering information is included as an attachment to this contract/purchase order. DRAWING DATA=BID123 |53711| -| |D|0001 | -|49998|0015028 DRAWING DATA=EB-3204 |96169| -|SP |D|0001 | -|00026|0000000 DOCUMENT REF DATA=ANSI/ASQ Z1.4 | | | |080101|A| | | DOCUMENT REF DATA=ASTM-B348 | | | |130701|A| | | DOCUMENT REF DATA=ASTM-B381 | | | |130701|A| | | DOCUMENT REF DATA=ASTM-B446 | | | |030610|A| | | DOCUMENT REF DATA=MIL-STD-792 | | |F |060519|A| | | DOCUMENT REF DATA=MIL-DTL-1222 | | |J |001208|A| | | DOCUMENT REF DATA=MIL-STD-2035 | | |A |950515|A| | | DOCUMENT REF DATA=SAE AMS 2380 | | |F |080401|A| | | DOCUMENT REF DATA=SAE AMS 2643 | | |C |020101|A| | | DOCUMENT REF DATA=ISO_9001 | | | |081115|A| | | DOCUMENT REF DATA=ISO10012 | | | |030415|A| | | DOCUMENT REF DATA=MIL-DTL-15024 | | |G |180303|A| | | DOCUMENT REF DATA=ISO/IEC 17025 | | | |050515|A| | | DOCUMENT REF DATA=MIL-DTL-24231 | | |E |130426|A| | | DOCUMENT REF DATA=MIL-I-45208 | | |A |810724|A| 1| | DOCUMENT REF DATA=MIL-STD-45662 | | |A |880801|A| | | DOCUMENT REF DATA=A-A-59004 | | |A |950907|A| | | DOCUMENT REF DATA=SAE AMS-STD-2154 | | |C |170501|A| | | DOCUMENT REF DATA=ANSI/NCSL Z540.3 | | | |130326|A| | | DOCUMENT REF DATA=0900-LP-003-8000 | | | |740701|A| |02| DOCUMENT REF DATA=S9074-AQ-GIB-010/248 | | | |950801|A| | | DOCUMENT REF DATA=T9074-AS-GIB-010/271 | | |1 |140911|A| | | DOCUMENT REF DATA=S9074-AR-GIB-010A/278 (CHG A) | | | |130214|A| | | 3. REQUIREMENTS 3.1 REFURBISHED MATERIAL STATEMENT OF WORK (REPAIR SOW) - 3.1.1 INSPECTION - Clean and determine if refurbishment is possible. At disassembly, the Contractor must record all identifying markings found on the parts of each assembly. The Contractor must maintain traceability of these markingsto each unit throughout refurbishment. 3.1.2 RE-USEABLE PARTS - Any parts of the original assembly that are useable (replacement is not necessary), may be utilized as initially supplied. 3.1.3 NON-USEABLE PARTS - Any parts of the original assembly that are not usable (replacement is necessary) must be in accordance with this TDP (Technical Data Package). 3.1.4 REFURBISHMENT - Upon completion of inspection, this item must be refurbished to be in accordance with ;Hamilton Standard Drawing SV799150; , except as amplified or modified herein. This applies to all "Parts Requiring Certification" as identified elsewhere in this Contract/Purchase Order. 3.1.5 Additional SOW Requirements - ;N/A; Part - ;Receptacle and Cable-Power, Find No. 51 and 61, along with Receptacle and Cable-Liquid Sensor, Find No. 62 on Drawing SV799150 (Receptacle Bodies only); Material - ;Starting Material shall be ASTM-B446, Grade 1. Final Mechanical Properties of representative test coupon shall meet requirements of ASTM-B446, Grade 2 for Yield and Ultimate Strengths; Part - ;Anode; Find No. 2 on Drawing SV799129 and Cover, Generator, Find No. 7 on Drawing SV799150; Material - ;ASTM-B348, Grade 2; Part - ;Cathode, Find No. 2 on Drawing SV799130; Material - ;ASTM-B348, Grade 2 (0.05% Fe max.) Annealed; Part - ;Base; Find No. 2 on Drawing SV799127, Cover; Find No. 2 on Drawing SV799124 and Body, Containment Vessel; Find No. 2 on Drawing SV799125; Material - ;ASTM-B381, Grade F-2, Annealed; Part - ;Stud, Threaded; Find No. 3 on Drawing SV799127, Stud; Find No. 3 on Drawing SV799125, Bolt, Hex Head; Find Nos. 43 and 47 and Nut, Hex; Find Nos. 42 and 45 on Drawing SV799150; Material - ;ASTM-B446, Grade 1; Test - ;Hydrostatic Test; Item - ;Receptacle and Cable-Power, Find Nos. 51 and 61, and Receptacle and Cable-Liquid Sensor, Find No. 62 on Drawing SV799150; Performance - ;Notes 18 and 23 on Drawings SV799119 and SV799133; Acceptance - ;Notes 18 and 23 on Drawings SV799119 and SV799133; Test - ;Dielectric-Strength Test; Item - ;Receptacle and Cable-Power, Find Nos. 51 and 61, and Receptacle and Cable-Liquid Sensor, Find No. 62 on Drawing SV799150; Performance - ;Note 24 on Drawings SV799119 and SV799133; Acceptance - ;Note 24 on Drawings SV799119 and SV799133; Test - ;Non-destructive Bonding Test; Item - ;Receptacle and Cable-Power, Find Nos. 51 and 61, and Receptacle and Cable-Liquid Sensor, Find No. 62 on Drawing SV799150; Performance - ;Figure 1 of MIL-DTL-24231; Acceptance - ;Figure 1 of MIL-DTL-24231; Test - ;100% Ultrasonic Inspection; Item - ;Starting material for Anode, Find No. 2 on Drawing SV799129; Cover, Generator, Find No. 7 on Drawing SV799150; Cathode, Find No. 2 on Drawing SV799130; Base, Find No. 2 on Drawing SV799127; Cover, Find No. 2 on Drawing SV799124; Body, Containment Vessel, Find No. 2 on Drawing SV799125; Performance - ;T9074-AS-GIB-010/271, except that zone testing, front half, with one half material plus .500 inch standard shall be allowed; Acceptance - ;SAE AMS-STD-2154, Table VI, Class A; ;Ultrasonic Inspection is not required for the Anode, Find No. 2 on drawing SV799129, when supplied as Government furnished material.; Test - ;Macrostructure Inspection; Item - ;Starting material for Anode, Find No. 2 on Drawing SV799129; Cover, Generator, Find No. 7 on Drawing SV799150; Cathode, Find No. 2 on Drawing SV799130; Base, Find No.2 on Drawing SV799127; Cover, Find No. 2 on Drawing SV799124; Body, Containment Vessel, Find No. 2 on Drawing SV799125; Performance - ;SAE-AMS-2643; Acceptance - ;SAE-AMS-2380, The macro-grain structure shall be equal to or better than level 30; ;Macrostructure Inspection is not required for the Anode, Find No. 2 on drawing SV799129, when supplied as Government furnished material.; Test - ;Liquid Penetrant Inspection; Item - ;Stud, threaded; find No. 3 on drawing SV799127, stud; find No. 3 on drawing SV799125, bolt hex head; find Nos. 43 and 47 and nut hex; find Nos. 42 and 45 on drawing SV799150; Performance - T9074-AS-GIB-010/271; Sampling must be per MIL-DTL-1222 Acceptance - MIL-DTL-1222 Test - ;100% Dye Penetrant Inspection; Item - ;Receptacle and Cable-Power, Find Nos. 51 and 61, and Receptacle and Cable-Liquid Sensor, Find No. 62 on Drawing SV799150 (Receptacle Bodies only); Anode, Find No. 2 on Drawing SV799129; Cover, Generator; Find No. 7 on Drawing SV799150; Cathode, Find No. 2 on Drawing SV799130; Base, Find No. 2 on Drawing SV799127; Cover, Find No. 2 on Drawing SV799124; Body, Containment Vessel, Find No. 2 on Drawing SV799125; Performance - ;T9074-AS-GIB-010/271; Acceptance - ;MIL-STD-2035 OR NAVSEA 0900-LP-003-8000; Test - ;Hydrostatic Test; Item - ;Each Assembly; Performance - ;Paragraph 4.1 and 4.4 of Specification SVHS13255; Acceptance - ;Paragraph 4.1 and 4.4 of Specification SVHS13255; Test - ;Leak Test; Item - ;Each Assembly; Performance - ;Paragraph 4.2 and 4.5 of Specification SVHS13255; Acceptance - ;Paragraph 4.2 and 4.5 of Specification SVHS13255; 3.2 Confidential Hydrostatic Test Pressures - When test pressures are confidential, certification must reference ;SVHS13255 Rev C (EB-3204); and the item number to which the item was tested in lieu of the actual pressures. Any drawing requirement to mark the working pressure on the item does not apply and is strictly prohibited. 3.3 ;Contactor shall perform a low pressure flow test on each assembly to verify that there are no flow path obstructions.; 3.4 Thread Lubricant - Thread lubricants containing molybdenum disulfide must not be used on this material. Bacteria in water, especially seawater, causes molybdenum disulfide to break down. The by-products of the breakdown form compounds which attack the fasteners. Anti-galling compound A-A-59004 must be used as a replacement when thread lubricant is required for assembly. 3.5 Internal Threads - All internal threads must be formed by cutting. Cold forming of internal threads is not acceptable. 3.6 Component Identification Description (CID) - When applicable drawing(s) and/or specification(s) specify that a nameplate or identification plate is required, the CID number ( ;CID 765007000; ) must be added. When no plate is specified, an identification plate in accordance with MIL-DTL-15024, Type "C" on brass or Type "H" on aluminum must be securely attached to each assembly showing the above CID number. No assembly must be shipped without the CID number attached. 3.7 Welding or Brazing - When welding, brazing, and allied processes are required, they must be in accordance with S9074-AR-GIB-010A/278, (S9074-AQ-GIB-010/248 for brazing) by personnel and procedures qualified under S9074-AQ-GIB-010/248 for all production and repair welding and brazing. Procedures and Qualification Data must be submitted for review and approval prior to performing any welding or brazing. 3.8 Certificate of Compliance - (SPECIAL EMPHASIS MATERIAL) The Contractor must prepare and submit a certificate of compliance certifying that the items/components furnished under this contract comply with the requirements of the procurement document, including any/all invoked specifications and drawings. 3.9 Configuration Control - The Contractor must maintain the total equipment baseline configuration. For items of proprietary design, Contractor drawings showing the latest assembly configuration must be provided to the Government in electronic (C4) format. Definitions are provided elsewhere in the Contract/Purchase Order. 3.9.1 Waivers/Deviations - All waivers and deviations, regardless of significance or classification require review and approval by the Contracting Officer. Waivers and Deviations must be designated as Critical, Major, or Minor. The Contractor must provide a copy of this request to the QAR. Requests must include the information listed below. a. A complete description of the contract requirement affected and the nature of the waiver/deviation (non-conformance), including a classification of Critical, Major, or Minor. b. Number of units (and serial/lot numbers) to be delivered in this configuration. c. Any impacts to logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel or impacts to the operational use of the product. d. Information about remedial action being taken to prevent reoccurrence of the non-conformance. 3.9.2 All requests for Waivers/Deviations on NAVSUP-WSS Contracts must be submitted using the ECDS (Electronic Contractor Data Submission) system at https://register.nslc.navy.mil/ 3.9.3 ECPs - The Government will maintain configuration control and change authority for all modifications or changes affecting form, fit, function, or interface parameters of the Equipment and its sub-assemblies. The Contractor must submit an Engineering Change Proposal (ECP) for any Class I or II changes that impact the Equipment covered by this contract. ECPs must be prepared in Contractor format, and must include the following information: a. The change priority, change classification (Class I or Class II), and change justification. b. A complete description of the change to be made and the need for that change. c. A complete listing of other Configuration Items impacted by the proposed change and a description of the impact on those CIs. d. Proposed changes to documents controlled by the Government. e. Proposed serial/lot number effectivities of units to be produced in, or retrofitted to, the proposed configuration. f. Recommendations about the way a retrofit should be accomplished. g. Impacts to any logistics support elements (such as software, manuals, spares, tools, and similar) being utilized by Government personnel in support of the product. h. Impacts to the operational use of the product. i. Complete estimated life-cycle cost impact of the proposed change. j. Milestones relating to the processing and implementation of the engineering change. 3.10 Mercury Free - Mercury and mercury containing compounds must not be intentionally added or come in direct contact with hardware or supplies furnished under this contract. Mercury contamination of the material will be cause for rejection. 3.11 NAVSEA 0948-LP-045-7010 - Any applicable requirements of NAVSHIPS 4410.17,NAVSEA 0948-LP-045-7010, or 0948-045-7010 which the contractor must meet are included in this contract/purchase order. The above documents are for GovernmentUse Only. Further application of the above documents is prohibited.prohibited. 3.11.1 Marking of material with a Material Designator per the Drawing is also prohibited, with the exception of Fasteners. Fasteners must be marked with a Material Symbol/Designator as specified elsewhere in this contract. ^ QUALITY ASSURANCE REQUIREMENTS ^ 3.12 See CDRL DI-MISC-80678 (Test Certification) - A statement of tests performed, listing the pieces tested must be furnished along with a copy of the test results. Certification must include the contractor's name, address and date, quantity inspected, identified to the contract/purchase order and item number, and the Contractor's or authorized personnel's signature. Test certifications must reference the standard/specification, including the revision, to which the testing was performed and the acceptance criteria used. Test procedure numbers may also be referenced on test reports. Test reports on weldments must be identified to weld joint and layer. 3.13 Quality System Requirements - The Contractor furnishing items under this contract/purchase order must provide and maintain a quality system in accordance with ISO-9001 as amplified or modified herein, with the calibration system requirements of ISO-10012 or ANSI-Z540.3 with ISO-17025. A Quality System in accordance with MIL-I-45208, with the calibration system requirements of MIL-STD-45662, is acceptable as an alternate. 3.13.1 The Contractor's quality system and products supplied under the system are subject to evaluation, verification inspection, and acceptance/nonacceptance by the Government representative to determine the system's effectiveness in meeting the quality requirements established in the Contract/Purchase Order. 3.13.2 The Contractor's quality system must be documented and must be available for review by the Contracting Officer or his representative prior to initiation of production and throughout the life of the contract. The Prime Contractor must, upon notification, make his facilities available for audit by the contracting Officer or his authorized representative. 3.13.3 See CDRL DI-QCIC-81110 (Inspection System Procedures) - All suppliers of Level I/SUBSAFE (LI/SS) material are required to submit a copy of their current documented quality system procedures to the Procurement Contracting OMore from United States Department of the Navy posted in October 2020