ClickCease Switchboard and MCC Panel Replacement | Closed - MatchAwards

Switchboard and MCC Panel Replacement

Status
Closed, the response deadline passed on Jul 31, 2026
Agency
United States Department of the Army
Office
FORT LEE, USA
Notice type
Sources Sought
Solicitation number
W91QF526QA004
NAICS
238210 - Electrical Contractors and Other Wiring Installation Contractors
PSC
J030 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MECHANICAL POWER TRANSMISSION EQUIPMENT
Category
Industrial Products Install / Maintenance / Repair (5.5)
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
2026-07-28
Deadline
2026-07-31
Place of performance
Radford, Virginia 24141, UNITED STATES

Description

SOURCES SOUGHT NOTICE

Notice Type: Sources Sought / Request for Information (RFI)
Title: Switchboard and Motor Control Center (MCC) Panel Replacement Service
Location: ALTESS Data Center, Radford Army Ammunition Plant, Radford, VA

1.0 Introduction and Purpose

This is a Sources Sought Notice issued for market research and planning purposes only. This is NOT a solicitation, Request for Proposal (RFP), Request for Quotation (RFQ), or Invitation for Bid (IFB). It does not constitute a commitment by the Government to issue a contract, nor will the Government pay for any information submitted in response to this notice.

The purpose of this Sources Sought is to identify qualified and capable sources (including Small Businesses, 8(a), Service-Disabled Veteran-Owned, HUBZone, and Women-Owned Small Businesses) that can provide the required removal, installation, and integration services for switchboards and Motor Control Center (MCC) panels at the ALTESS data center.

2.0 Background and Scope Summary

The Contractor shall provide removal of one (1) Westinghouse switchboard and Motor Control Center (MCC) panel located in RM 241, and one (1) GE switchboard to include associated Motor Control Center (MCC) panel located in RM 119, and provide customized installation of one (1) Eaton (or equal) switchboard and Motor Control Center (MCC) panel located in RM 241, and one (1) Eaton (or equal) switchboard and Motor Control Center (MCC) panel located in RM 119 located within the ALTESS data center located on site in Radford, VA 24141-1061.

Specific Tasks:
 

Room 119 Equipment Removal & Installation Services:

Westinghouse Fused Switchboard and Motor Control Center (MCC): Westinghouse fused switchboard and motor control center (MCC) panel replacement service shall include:       

Room 241 Equipment Removal & Installation Services:

3.0 Requested Capability Statement

Interested parties are requested to submit a Capability Statement demonstrating their ability to perform the services described in the SOW. Please provide the following information structured in your response:

Requirement Category

Specific Information Requested

Company Profile

Company Name, Address, CAGE Code, and Unique Entity ID (UEI).

Point of Contact

Name, Title, Phone Number, and Email Address of the primary representative.

Business Size & Socio-Economic Status

Specify your business size under the applicable NAICS code (238210 - Electrical Contractors) and any applicable socio-economic categories (e.g., 8(a), SDVOSB, WOSB, HUBZone).

Technical Capability

Detailed narrative demonstrating the capability to provide, install, and customize Eaton (or equal) switchboards/MCCs. Must explicitly address the ability to provide a certified Trane Authorized Controls technician and integrate with Schneider Electric StruxureWare.

Logistics & Security

Statement of ability to conduct required after-hours/weekend repowering work and comply with Radford Army Ammunition Plant (RFAAP) security and background check requirements.

Past Performance

Briefly describe up to three (3) similar projects completed within the last five (5) years involving data center power infrastructure replacement, BAS integration, and secure facility operations.

4.0 Submission Instructions

Responses should be concise and focused on the capability to meet the Government's requirements.

Submission Detail

Instruction

Page Limit

Maximum of ten (10) pages.

Document Format

PDF or Microsoft Word format.

Submission Email

KO heather.b.jarratt.civ@army.mil, CS kenneth.r.lancaster11.civ@army.mil, and CC: sharon.e.bane.civ@army.mil (COR)

Response Deadline

Thursday, May 21, 2026 at 12:00 PM EST

Subject Line

Sources Sought Response: ALTESS Switchboard & MCC Replacement

Disclaimer: Information received in response to this notice will be used solely for market research and acquisition strategy planning. Proprietary information, if any, should be minimized and MUST BE CLEARLY MARKED. To aid the Government, please segregate proprietary information

Attachments

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of the Army posted in May 2026

More lists