<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/115020448047220709" -->

---
title: Fire alarm panel (W911S225U1526) | Closed - MatchAwards
description: Fire alarm panel. United States Department of the Army. Solicitation W911S225U1526. NAICS 335311 - Power, Distribution, and Specialty Transformer Manufacturing. Total small business set-aside. Deadline 2025-08-18. Model: MAAP-X Fire Alarm PanelPart Number: 227-968-00, 326-M01-20Qty. 1 ? MAAP-X...
canonical: https://matchawards.com/dept_of_the_army/posts/115020448047220709
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Fire alarm panel (W911S225U1526) | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/115020448047220709
og:description: Fire alarm panel. United States Department of the Army. Solicitation W911S225U1526. NAICS 335311 - Power, Distribution, and Specialty Transformer Manufacturing. Total small business set-aside. Deadline 2025-08-18. Model: MAAP-X Fire Alarm PanelPart Number: 227-968-00, 326-M01-20Qty. 1 ? MAAP-X...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Fire alarm panel

Status

Closed, the response deadline passed on Aug 18, 2025

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

FORT DRUM, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

W911S225U1526

NAICS

[335311 - Power, Distribution, and Specialty Transformer Manufacturing](/groups/531)

PSC

1265 - FIRE CONTROL TRANSMITTING AND RECEIVING EQUIPMENT, EXCEPT AIRBORNE

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2025-08-11

Deadline

2025-08-18

Place of performance

74501

## Description

Model: MAAP-X Fire Alarm PanelPart Number: 227-968-00, 326-M01-20Qty. 1 ? MAAP-X Addressable Fire Alarm MNS Voice Evacuation Panel? Frequency of 138.95 (last five digits of part number)? Includes master control unit (MCU) with a color touch screen for fire and MNS Operation? An MNS message card with nine standard prerecorded messages (eight dedicated MNS, one dedicated fire)? An Analog Addressable Controller II (AAC II) backplane.? One ADCQ ? One SOC? Eight Class B or four Class A non-loop-powered Initiating Device Circuits (IDCs)? Eight Class B or four Class A regulated or synchronized programmable NACs ? Four Form C programmable relays? Autosensing power supply, 120/240 VAC 50/60 H? Dual rate 4A 24 VDC battery charger that meets the requirements of NFPA 72 and UL 864? Q24 VDC auxiliary power ? FSK interface for communication to D-21 through the standard integrated transceiver, or optional network or fiber module? Fire and MNS operation for first responders? Simple English messages identify alarm, trouble, and supervisory conditions? User-defined device and zone descriptions? Panel reset, alarm/trouble silence ? Displays zone input or addressable device programmable descriptions? LED status indicators for primary/secondary power, radio communication, general alarm, and trouble? Panel maintenance functions, such as: ? Zone and sensor device enable/disable? Walk test? Radio key-up test? Enhanced diagnostic information?identifying panel troubles and loop faults? Panel history? Standard card has eight default prerecorded MNS messages and one fire evacuation message for a total of nine prerecorded messages? User-defined messages available with a customer-option message card with eight user-defined prerecorded MNS messages and one user-defined prerecorded fire evacuation message? Transfer between AC primary power and battery secondary power is automatic 

<!-- mobian-agent-ad sponsored="true" id="e60deeb7-c364-4364-b70a-7f1f65227eb8" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/0397f8fd9ea4480ea58f66f03705e159/view)

[More from United States Department of the Army posted in August 2025](/dept%5Fof%5Fthe%5Farmy/archive/2025-08)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Fire alarm panel","description":"Model: MAAP-X Fire Alarm PanelPart Number: 227-968-00, 326-M01-20Qty. 1 ? MAAP-X Addressable Fire Alarm MNS Voice Evacuation Panel? Frequency of 138.95 (last five digits of part number)? Includes master control unit (MCU) with a color touch screen for fire and MNS Operation? An MNS message card with nine standard prerecorded messages (eight dedicated MNS, one dedicated fire)? An Analog Addressable Controller II (AAC II) backplane.? One ADCQ ? One SOC? Eight Class B or four Class A non-loop-powered Initiating Device Circuits (IDCs)? Eight Class B or four Class A regulated or synchronized programmable NACs ? Four Form C programmable relays? Autosensing power supply, 120/240 VAC 50/60 H? Dual rate 4A 24 VDC battery charger that meets the requirements of NFPA 72 and UL 864? Q24 VDC auxiliary power ? FSK interface for communication to D-21 through the standard integrated transceiver, or optional network or fiber module? Fire and MNS operation for first responders? Simple English messages identify alarm, trouble, and supervisory conditions? User-defined device and zone descriptions? Panel reset, alarm/trouble silence ? Displays zone input or addressable device programmable descriptions? LED status indicators for primary/secondary power, radio communication, general alarm, and trouble? Panel maintenance functions, such as: ? Zone and sensor device enable/disable? Walk test? Radio key-up test? Enhanced diagnostic information?identifying panel troubles and loop faults? Panel history? Standard card has eight default prerecorded MNS messages and one fire evacuation message for a total of nine prerecorded messages? User-defined messages available with a customer-option message card with eight user-defined prerecorded MNS messages and one user-defined prerecorded fire evacuation message? Transfer between AC primary power and battery secondary power is automatic","url":"https://matchawards.com/dept_of_the_army/posts/115020448047220709","identifier":"W911S225U1526","category":"335311 - Power, Distribution, and Specialty Transformer Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"1265 - FIRE CONTROL TRANSMITTING AND RECEIVING EQUIPMENT, EXCEPT AIRBORNE"}],"availabilityStarts":"2025-08-11","availabilityEnds":"2025-08-18","validThrough":"2025-08-18T23:59:59-04:00","areaServed":"74501","sameAs":"https://sam.gov/opp/0397f8fd9ea4480ea58f66f03705e159/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```