<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/114869367151096217" -->

---
title: Radio Frequency Therapy System for WACH | Closed - MatchAwards
description: Radio Frequency Therapy System for WACH. United States Department of the Army. Solicitation W81K0025QA150. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2025-08-26. Clinical Efficacy and Performance. Ablation Success Rates: Documented amenorrhea rates (e.g.,>50-60%) and a...
canonical: https://matchawards.com/dept_of_the_army/posts/114869367151096217
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Radio Frequency Therapy System for WACH | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/114869367151096217
og:description: Radio Frequency Therapy System for WACH. United States Department of the Army. Solicitation W81K0025QA150. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2025-08-26. Clinical Efficacy and Performance. Ablation Success Rates: Documented amenorrhea rates (e.g.,>50-60%) and a...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Radio Frequency Therapy System for WACH

Status

Closed, the response deadline passed on Aug 26, 2025

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

JBSA FT SAM HOUSTON, USA

Notice type

Sources Sought

Solicitation number

W81K0025QA150

NAICS

[339112 - Surgical and Medical Instrument Manufacturing](/groups/582)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2025-08-19

Deadline

2025-08-26

Place of performance

Fort Stewart, Georgia 31314, UNITED STATES

## Description

Clinical Efficacy and Performance.

Ablation Success Rates: Documented amenorrhea rates (e.g.,>50-60%) and a significant reduction in bleeding (e.g.,>90% patient satisfaction) at 12 months post-procedure from clinical trials or post-market surveillance.

<!-- mobian-agent-ad sponsored="true" id="fd292f6f-14e0-40a8-831d-1fe94227d078" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


Treatment Time: Short, standardized procedure time (e.g., typically <90 seconds for the RF energy delivery phase, total procedure time including setup and removal <5-10 minutes)

Uterine Cavity Compatibility: Stated range of uterine lengths (e.g., 6-10 cm, or 8-12 cm) and fundal width accommodation (e.g., by expandable array). Ensures applicability to a broad range of patients without requiring multiple specialized probes, reducing inventory and ensuring more patients are eligible (e.g., 4-6mm) across the entire endometrial surface, including cornual regions, as confirmed by histology or follow-up. Importance: reduced risk of incomplete alation, persistent bleeding, and need for repeat procedure.

End-point Detection: Automatic system shut-off based on reaching specific internal parameters (e.g., impedance rise, temperature plateau, complete energy delivery) that indicate successful ablation. Endures consistent, complete ablation while preventing overtreatment and relies less on user judgment, improving consistency across multiple gynecologists.

Real-time Monitoring and Feedback: Continuous, real-time display of critical parameters such as intrauterine temperature, pressure (if balloon-based), and impedance. Allows immediate detection of potential issues (e.g., perforation, inadequate tissue contact) and endures optimal ablation. System automatically terminates energy delivery and provides distinct auditory/visual alarms for abnormal conditions (e.g., uterine perforation/pressure drop, excessive temperature, high impedance, low tissue contact, power surges0\. Prevents patient injury and ensures a safe procedure even with varying user experience.

Intuitive user Interface: Touchscreen interface with clear, guided prompts; minimal steps for setup and operation; single button start/stop for ablation. Can be assessed by observing average setup time for a new user (< 5 minutes) or number of steps to initiate therapy. Reduces training time for six gynecologists and support staff, minimized user errors and streamlines workflow in a busy operating room (OR).

Disposable Probe/Catheter Design: Single use, presterilized probe. Easy inserting and removal without complex maneuvers. Minimal components for assembly. Ensures sterility, eliminates reprocessing needs, and simplifies setup/takedown for faster OR turnover.

Does not have to interface with other equipment.

Minimum one-year warranty, guaranteed service response time (e.g., <24 hours for phone support, <48 hours for on-site repair), comprehensive warranty (e.g., 1-2 years) and availability of local field service engineers. Ensure rapid resolution of issues, minimizing disruption to patient scheduling.

Clear policy on software upgrades (e.g., free for the life of the product, or clear upgrade path/cost) for performance enhancements and bug fixes. Ensure system remains current and supported.

Availability of on-site training for all six gynecologists and support staff, including hands-on simulation, clinical proctoring and comprehensive user manuals/videos.

Access to clinical specialists for ongoing questions, troubleshooting and best practice sharing. Valuable resource for optimization and addressing specific case challenges for multiple users. Ensure all six surgeons are proficient and comfortable leading to consistent outcomes and reduced errors.

FDA clearance (510(k)) and/or CE mark. Confirms device meets established safety and efficacy standards.

## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/98d4df8ca9b4444fad6d081f180cf8da/download)

## Contacts

* Troy Loge
* Kiah Washington

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/0eb42353bb52440289a7c26c1612558b/view)

[More from United States Department of the Army posted in July 2025](/dept%5Fof%5Fthe%5Farmy/archive/2025-07)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Radio Frequency Therapy System for WACH","description":"Clinical Efficacy and Performance. Ablation Success Rates: Documented amenorrhea rates (e.g.,\u003e50-60%) and a significant reduction in bleeding (e.g.,\u003e90% patient satisfaction) at 12 months post-procedure from clinical trials or post-market surveillance. Treatment Time: Short, standardized procedure time (e.g., typically \u003c90 seconds for the RF energy delivery phase, total procedure time including setup and removal \u003c5-10 minutes) Uterine Cavity Compatibility: Stated range of uterine lengths (e.g., 6-10 cm, or 8-12 cm) and fundal width accommodation (e.g., by expandable array). Ensures applicability to a broad range of patients without requiring multiple specialized probes, reducing inventory and ensuring more patients are eligible (e.g., 4-6mm) across the entire endometrial surface, including cornual regions, as confirmed by histology or follow-up. Importance: reduced risk of incomplete alation, persistent bleeding, and need for repeat procedure. End-point Detection: Automatic system shut-off based on reaching specific internal parameters (e.g., impedance rise, temperature plateau, complete energy delivery) that indicate successful ablation. Endures consistent, complete ablation while preventing overtreatment and relies less on user judgment, improving consistency across multiple gynecologists. Real-time Monitoring and Feedback: Continuous, real-time display of critical parameters such as intrauterine temperature, pressure (if balloon-based), and impedance. Allows immediate detection of potential issues (e.g., perforation, inadequate tissue contact) and endures optimal ablation. System automatically terminates energy delivery and provides distinct auditory/visual alarms for abnormal conditions (e.g., uterine perforation/pressure drop, excessive temperature, high impedance, low tissue contact, power surges0. Prevents patient injury and ensures a safe procedure even with varying user experience. Intuitive user Interface: Touchscreen interface with clear, guided prompts; minimal steps for setup and operation; single button start/stop for ablation. Can be assessed by observing average setup time for a new user (\u003c 5 minutes) or number of steps to initiate therapy. Reduces training time for six gynecologists and support staff, minimized user errors and streamlines workflow in a busy operating room (OR). Disposable Probe/Catheter Design: Single use, presterilized probe. Easy inserting and removal without complex maneuvers. Minimal components for assembly. Ensures sterility, eliminates reprocessing needs, and simplifies setup/takedown for faster OR turnover. Does not have to interface with other equipment. Minimum one-year warranty, guaranteed service response time (e.g., \u003c24 hours for phone support, \u003c48 hours for on-site repair), comprehensive warranty (e.g., 1-2 years) and availability of local field service engineers. Ensure rapid resolution of issues, minimizing disruption to patient scheduling. Clear policy on software upgrades (e.g., free for the life of the product, or clear upgrade path/cost) for performance enhancements and bug fixes. Ensure system remains current and supported. Availability of on-site training for all six gynecologists and support staff, including hands-on simulation, clinical proctoring and comprehensive user manuals/videos. Access to clinical specialists for ongoing questions, troubleshooting and best practice sharing. Valuable resource for optimization and addressing specific case challenges for multiple users. Ensure all six surgeons are proficient and comfortable leading to consistent outcomes and reduced errors. FDA clearance (510(k)) and/or CE mark. Confirms device meets established safety and efficacy standards.","url":"https://matchawards.com/dept_of_the_army/posts/114869367151096217","identifier":"W81K0025QA150","category":"339112 - Surgical and Medical Instrument Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2025-08-19","availabilityEnds":"2025-08-26","validThrough":"2025-08-26T23:59:59-04:00","areaServed":"Fort Stewart, Georgia 31314, UNITED STATES","sameAs":"https://sam.gov/opp/0eb42353bb52440289a7c26c1612558b/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

