ClickCease Bldg 2000 Secure Area Upgrades | Closed - MatchAwards

Bldg 2000 Secure Area Upgrades

Status
Closed, the response deadline passed on Aug 7, 2025
Agency
United States Department of the Army
Office
COLUMBUS, USA
Notice type
Sources Sought
Solicitation number
W50S8P25BA001
NAICS
236220 - Commercial and Institutional Building Construction
PSC
Z2AA - REPAIR OR ALTERATION OF OFFICE BUILDINGS
Category
Facility Related Services (4.4)
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
2025-08-09
Deadline
2025-08-07
Place of performance
Columbus, Ohio 43217, UNITED STATES

Description

Building 2000 Secure Area Update Sources Sought

The purpose of this synopsis is to gain knowledge of potential sources for this project including interested Small Business sources. This notice is for planning purposes only. All interested parties should respond. Rickenbacker Air National Guard Base, Ohio intends to issue a solicitation and award of a contract to “Building 2000 Secure Area Update”.
The magnitude of this project is between $250,000 and $500,000. All interested concerns will provide this office, in writing, a notice stating their positive intent to submit a proposal as a prime contractor no later than 6 June 2025. This notification, which shall not exceed five typewritten pages, must include (1) positive statement of intent to bid as a prime contractor, and (2) a completed and signed Source Sought Information Request Form (add link to form) and (3) A listing of projects completed during the past three years, both for government and private industry. The type of project, dollar value, Contract number, location, and Point of Contact are to be included. Indicate if you were prime or subcontractor, and if subcontractor, provide the name and point of contact for the prime contractor. (4) A brief outline of resources, subcontractors, and key personnel that would be used to accomplish the contract.
In the event adequate Small Business contractors are not available for adequate competition for this project, it may be advertised as unrestricted. Information shall be provided via email to: 121.msg.contracting@us.af.mil. Include the following in the subject line "Sources Sought W50S8P-25-B-A001". No facsimile responses will be honored.

Project Summary 

To enhance security at the 121st Air Refueling Wing facility, the contractor will undertake a comprehensive modification of a 750 sf. office suite to meet stringent ICD 705 standards. This involves upgrading perimeter walls to achieve an STC 50 rating with sound attenuation and RF shielding, removing and infilling existing windows, managing utility and HVAC duct penetrations with sound masking and security measures, installing a new STC 50 security door with specific hardware requirements, and conducting thorough RF shielding attenuation testing to ensure compliance. The work also includes matching all new finishes to the existing aesthetic, ensuring a cohesive and secure environment.

Attachments

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of the Army posted in May 2025

More lists