Bldng 957 Vault Repair and Bldng 937 Exit door Installation
- Status
- Closed, the response deadline passed on Aug 13, 2024
- Agency
- United States Department of the Army
- Office
- LACKLAND AFB, USA
- Notice type
- Sources Sought
- Solicitation number
- W50S78-SS
- NAICS
- 236220 - Commercial and Institutional Building Construction
- PSC
- Y1JZ - CONSTRUCTION OF MISCELLANEOUS BUILDINGS
- Category
- Construction Related Services (4.2)
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- Posted
- 2024-08-01
- Deadline
- 2024-08-13
- Place of performance
- Fort Cavazos, Texas 78236, UNITED STATES
Description
DEMO
BLDNG 957:
Remediate and properly remove existing metal window in accordance with UFGS 02 82 00
Asbestos Remediation and UFGS 02 83 00 Lead Remediation. Existing window metal frame,
has Lead based paint with asbestos on their window glaze.
NEW WORK
BLDNG957:
Provide and install new door seals and/or door sweeps for two standard man doors in the space
to ensure they meet sound attenuation. (Submittal #1)
Fill with concrete masonry unit (CMU) new open window area. Prepare and paint new install
CMU to match existing paint.
Ground existing conduit within six inches of the perimeter wall to an approved earth ground.
BLDNG 937:
Provide and install new sound rated seals (Sides and drops) and/or door sweeps along with
astragals to two Double 12’ Equipment Doors Emergency exits to meet sound attenuation.
Attachments
More from United States Department of the Army posted in August 2024