<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/112007581721776242" -->

---
title: Albeni Falls Project Fencing | Closed - MatchAwards
description: Albeni Falls Project Fencing. United States Department of the Army. Solicitation W912DW24Q0013. NAICS 238990 - All Other Specialty Trade Contractors. Total small business set-aside. Deadline 2024-03-08. *Note: See attached Statement of Work & Request For Quote for complete project details. Scope...
canonical: https://matchawards.com/dept_of_the_army/posts/112007581721776242
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Albeni Falls Project Fencing | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/112007581721776242
og:description: Albeni Falls Project Fencing. United States Department of the Army. Solicitation W912DW24Q0013. NAICS 238990 - All Other Specialty Trade Contractors. Total small business set-aside. Deadline 2024-03-08. *Note: See attached Statement of Work & Request For Quote for complete project details. Scope...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Albeni Falls Project Fencing

Status

Closed, the response deadline passed on Mar 8, 2024

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

SEATTLE, USA

Notice type

Solicitation

Solicitation number

W912DW24Q0013

NAICS

[238990 - All Other Specialty Trade Contractors](/groups/237)

PSC

5660 - FENCING, FENCES, GATES AND COMPONENTS

Category

[Security Systems (3.2)](/categories/security-and-protection/security-systems)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2024-02-27

Deadline

2024-03-08

Place of performance

Oldtown, 83822

## Description

\*Note: See attached Statement of Work & Request For Quote for complete project details. Scope of Work Albeni Falls Project Fencing Contract Albeni Falls Dam, Idaho General Information 1\. General: This is a non-personal requirement to provide services consisting of repair, replacement and/or newly constructing fencing at the Albeni Falls Dam Project. The project office is located at 2376 E Highway 2, Oldtown Idaho, 83822\. The Government shall not exercise any supervision or control over the contractor. Subcontractors shall be accountable solely to the Contractor who, in turn is responsible to the Government. 1.1 Description /Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, parts, supervision, and other items to accomplish this non-personal services requirement necessary to perform the replacement/construction as defined in this Statement of Work (SOW). The contractor shall perform to the standards in this contract. 1.2 Background: The United States Army Corps of Engineers manages the Albeni Falls Powerhouse. It is their responsibility to ensure protection, integrity, and stewardship of public lands and infrastructure under their jurisdiction. A part of the management requires proactive inspection and replacement/reinforcement of boundary identification such as fences, line signage, blazing, clearing, and survey monuments to ensure boundary lines are clearly defined and visible to adjacent properties, which is helpful in preventing encroachments and trespasses. Currently there are areas in and around the powerhouse where no fencing currently exists, areas which have been damaged and need repaired, and areas not designed to required security standards. Fencing work is needed at: Albeni Falls Dam Project Powerhouse 2376 E. Highway 2 Oldtown, Idaho 83822 1.3 Principal Items to be Accomplished: All work must be accomplished in accordance with the material and installation standards found in sections 1.3.1 and 1.3.2 of this contract. Installation details found in Technical Exhibit 8, must also be followed. Base Bid Item 0001 Powerhouse Repairs Near Transformer Yard Refer to Technical Exhibits 1a and 1b. Technical Exhibit 1a: Part A: Replace vertical barbed wire with two (2) perpendicular 3 chain link panels with 7 fabric height. Install 18 diameter strand of razor wire vertically along inside edge of newly installed chain link panel nearest Part B. Part B: Add 18 razor wire on inside edge of fence above top horizontal rail. See red line on Technical Exhibit 1a for location. Length is 20\. Gate: Extend height of gate 14 and extend fabric to account for additional gate height. Reinstall 3 strands of barbed wire at top of gate. Gate is 3.5 wide. Technical Exhibit 1b: Part C: Raise end post 20 as represented by red cylinder on Technical Exhibit 1b. Replace all barbed wire and terminate barbed wire at end posts, not outriggers. Replace vertical barbed wire that hangs over cliff edge with a minimum of a 4 wide by 6 tall, cantilevered chain link panel. Add 18 razor wire along entire length of inside edge of barbed wire and outriggers and down the side of the newly installed chain link panel that hangs over the cliff edge. Length of fence is 30\. Note that fall protection is required when working in the area near the cliff edge. An accident prevention plan, fall protection plan, and activity hazard analysis is required to be submitted for government approval prior to start of work. Examples of these documents can be found in the EM 385-1-1\. Base Bid Item 0002 Powerhouse Repairs Near Entrance Gate Refer to Technical Exhibit 2\. Install new 18 diameter razor wire vertically at slide gate on end closest to the powerhouse. See red rectangle on Technical Exhibit 2 for location. Razor wire shall extend from the conduit mounted on the vertical concrete wall to the top of the security gate. Total length of razor wire is 12\. Note that fall protection is required when working in the area with fall hazard. An accident prevention plan, fall protection plan, and activity hazard analysis is required to be submitted for government approval prior to start of work. Examples of these documents can be found in the EM 385-1-1\. Base Bid Item 0003 Powerhouse Repairs Near Spillway Side of Island Refer to Technical Exhibit 3\. Install (1) 10 section of security fence with 8 fabric, (1) end post, outriggers, and barbed wire per security fence specifications. Tie this portion of fence into the existing fence located on the spillway side of the island near the spillway gate maintenance pit. A 4 long section of fence is also required on the downhill side and running perpendicular to the newly installed fence to block the opening between the new fence section and the spillways concrete structure. Install 18 diameter razor wire on any portion that does not adequately deter climbing over fence. Follow security fence specifications for construction and installation. Base Bid Item 0004 Powerhouse Repairs on South Abutment Refer to Technical Exhibits 4a, 4b, 4c, and 4d. Technical Exhibits 4a and 4b: Existing fence fabric needs to be lowered to within 2 of the ground in multiple locations on South abutment fence. In areas where fabric lowering does not bring fabric to within 2 of the ground due to uneven terrain, rebar shall be epoxied into holes that are rotary drilled into the rocky terrain at spacing no greater than 6 to fill the gap. There is approximately 250 of fencing that needs to be lowered. Technical Exhibit 4c: Readjust approximately 20 outriggers and tack weld into position. Base Bid Item 0005 Powerhouse Repairs on South Abutment Western Edge Refer to Technical Exhibits 5a, 5b and 5c. Technical Exhibit 5a: Extend gate post height by 6\. Remove outriggers and barbed wire. Install new barbed wire and attach to raised gate posts. Install new 18 diameter strand of razor wire on inside edge of new barbed wire. Tack weld clamp holding gate latch to fence post in place so clamp cannot rotate. Gate is 12 wide. Technical Exhibit 5b: Remove and replace all barbed wire and razor wire along this section. Barbed wire shall be attached to end posts at termination and not outriggers, per security fencing specifications. Readjust any outriggers as required and tack weld into place. Total length of fence in this area is 70\. Technical Exhibit 5c: Extend fence post shown in red by approximately 12 to provide attachment point for barbed wire. Remove and replace all barbed wire in locations indicated by red lines. Replace razor wire in locations that it was removed. Total length of fence in this area is 35\. Note that fall protection is required when working in the area near the cliff edge. Technical Exhibit 5c is near a cliff edge. An accident prevention plan, fall protection plan, and activity hazard analysis is required to be submitted for government approval prior to start of work. Examples of these documents can be found in the EM 385-1-1\. Base Bid Item 0006 Powerhouse Repairs on South Abutment Eastern Edge Refer to Technical Exhibit 6 Replace vertical barbed wire with 5 wide by 6 tall, cantilevered chain link panel. Install 18 diameter razor wire along perimeter of panel. Note that fall protection is required when working in the area near the cliff edge. Technical Exhibit 6 is near a cliff edge. An accident prevention plan, fall protection plan, and activity hazard analysis is required to be submitted for government approval prior to start of work. Examples of these documents can be found in the EM 385-1-1\. Materials: Standards for security fencing materials at the powerhouse: Fabric and Accessories Fencing fabric must be mounted on steel posts that are set in concrete with additional bracing at corners and gate openings, as necessary. If steel posts are not available, reinforced concrete posts will be used. Posts, bracing, and all other structural members must be placed on the secure side of the fencing fabric. Fencing fabric shall consist of FS RR-F191/1, Type 1, zinc-coated steel wire with minimum coating weight of 1.2 ounces of zinc per square foot of coated surface. Fencing fabric must be minimum 9-gage wire mesh and mesh openings must be not be greater than 2-inches per side. Fence fabric material will be galvanized steel. The fencing fabric must be extended to within 2-inches of firm ground and anchored, using horizontal bottom rails, tension wires, concrete curbs, sills, sheet piling, piping, or other materials. Horizontal bottom rails, concrete curbs, or sills can assist in mitigating an intruder from lifting the fence fabric beyond the requirement above. Mesh openings in chain link fencing are intended to not be covered, blocked, or laced with material which would prevent a clear view of personnel, vehicles, or material in outer clear zones. Locate all posts, rails, bracing and tension wires on the secure/protected side, i.e. inner side, of the fencing fabric. Select the framework components and material from ASTM F626, ASTM F1043, and ASTM F1083\. Tension wire shall be 7-gauge galvanized spring steel wire. Ferrous accessories shall be zinc or aluminum coated. Fence Fabric Height Unless otherwise directed all security and perimeter fencing must have a minimum fence fabric height of 7 feet, excluding the top guard. Fence height including outriggers must be a minimum of 8 feet. Posts, Rails, and Braces Posts must be vertical within plus or minus 2 degrees in each direction. Determine the embedment depth of the fence posts and associated footings considering wind load, local soil conditions, and the potential for wind and water erosion. Posts for security fencing must be spaced, embedded, and encased in concrete according to the design details in Appendix A. Concrete shall comply with ASTM C-94 using inch maximum size aggregate and having a minimum compressive strength of 3,000 PSI at 28 days NOTE: Steel pipe is available in two grades: A or B. Grade A is zinc-coated with 1.8 ounces per square foot of zinc. Grade B consists of a zinc-coating with 0.9 ounce per square foot, a chromate conversion coating, followed by a clear acrylic or polyester coating. Grade A pipe which has the heavier zinc-coated interior may be desired in some coastal regions located in highly corrosive salt-laden environments to prevent rust caused by condensation inside the pipe. Grade A or Grade B pipe may be used in inland and desert areas, provided Grade B pipe meets the salt spray test. Line Posts Provide minimally acceptable end, corner, and pull posts as follows: 2.375-inch O.D. Galvanized. End, Corner, and Pull Posts Provide minimally acceptable end, corner, and pull posts as follows: Grade A: DN70 2.875-inch O.D. pipe weighing 5.79 pounds per linear foot, Or Grade B: DN70 2.875-inch O.D. pipe weighing 4.64 pounds per linear foot. Sleeves Provide sleeves for setting into concrete construction of the same material as post sections, sized 1 inch greater than the diameter or dimension of the post. Weld flat plates to each sleeve base to provide anchorage and prevent intrusion of concrete. Top Rail Provide top rails with a minimum of DN40 1.660 inches O.D. pipe rails. Grade A weighing 2.27 pounds per linear foot, Or Grade B weighing 1.82 pounds per linear foot. Provide expansion couplings 6 inches long at each joint in top rails. Center Rails Between Line Posts Provide DN40 1.660 inches O.D. pipe center rails, Grade A weighing 2.27 pounds per linear foot Or Grade B weighing 1.82 pounds per linear foot. Bottom Rail Provide bottom rail conforming to minimum sizes specified in FS RR-F-191/3 for each class and grade unless members are to be oversized. Post-Brace Assembly Provide bracing consisting of DN40 1.660 inches O.D. pipe \[Grade A weighing 2.27 pounds per linear foot\] Or \[Grade B weighing 1.82 pounds per linear foot\] and 3/8-inch adjustable truss rods and turnbuckles. Provide bracing for each gate, terminal, and end post. Install truss rods diagonally from near ground level of the gate, terminal, or end post to within 6 inches from the top of the fabric at the adjacent line post. Fencing fabric can be securely fastened to tension wires on the top and bottom with 9 gage galvanized tie wires incorporating at least three full twists, 9 gage round wire galvanized hog rings, or in a manner that provides a tensile strength equal to or greater than the strength of the fencing fabric. Consider securing all fastening and hinge hardware by peening or welding to prevent disassembly of fencing and gate components where warranted by the required level of protection. Stretcher Bars Provide bars that have one-piece lengths equal to the full height of the fabric with a minimum cross section of 3/16 by inch, in accordance with ASTM F626\. Stretcher Bar Bands Provide bar bands for securing stretcher bars to posts that are steel, wrought iron, or malleable iron spaced not over 15 inches on center. Bands may also be used in conjunction with special fittings for securing rails to posts. Provide bands with projecting edges chamfered or eased. Post Tops Provide tops that are steel, wrought iron, or malleable iron designed as a weathertight closure cap. Provide one cap for each post unless equal protection is provided by a combination post-cap and wire supporting arm. Provide caps with an opening to permit through passage of the top rail. Top and Bottom Selvages Selvage is the edge finish on woven chain link fabric joining pairs of pickets. The selvage may be knuckled or twisted depending on application. Knuckled selvage is defined as the type of selvage obtained by interlocking adjacent pairs of wire ends and bending the wire back into a loop. Twisted is obtained by twisting adjacent pairs of wire ends together in a close helix of 11?2 machine turns, which is equivalent to three full twists. Twisted selvage must be provided on the top of the fence fabric to deter climbing. Twisted selvage must be provided at the bottom of the fence fabric to deter borrowing unless the fence has a bottom rail, is buried, or encased in concrete. In these applications the selvage may be knuckled. See Figure 2-2 for selvage examples Figure 2-2 Selvage Top Guards, Barbed Wire and Concertina Wire When required, install outriggers (support arms) at 45-degree angles in a single arm (towards the threat side) or Y/V configuration, constructed of a single or double outrigger consisting of 18-inch arm(s), each having three strands of barbed wire at regular intervals along the top of the fence. The outriggers must provide a minimum of an additional 12-inches to the fence height. The top guard fencing adjoining gates may range from a vertical height of 18-inches to the normal 45-degree outward protection, but for a limited distance along the fence line to adequately open the gates. Outriggers must be permanently affixed to the fence posts with screws or by spot welding. Screws used to affix outriggers to posts must be made tamper-proof either by design, peening, or welding. Outrigger/Barbed Wire Arm Material Specifications Top guards must be constructed of the same material as the other fencing components in accordance to ASTM F626\. See Appendix 9A for details. Barbed Wire and Barbed Tape Concertina Barbed wire is a fabricated wire product consisting of two-line wires twisted to form a two-wire strand, into which 2point or 4point barbs are tightly wrapped and locked into place at specific intervals. Barbed tape concertina is a strip of metal, machined to produce clusters of sharp points. Provide three strands of barbed wire, equally spaced, on outrigger/support arms where barbed tape/concertina is mounted. Barbed Wire Fences requiring barbed wire must use a minimum of 3 strands of barbed wire equally spaced. Additional strands may be added as required. Barbed wire must consist of two 12.5 -gage /0.099-inch (+0\. 005- inch) twisted line wires with 15- gage /0.080- inch (+0, 005-inch) round barbs. Barbed wire must be zinc-coated steel, aluminum coated steel, aluminum alloy, or PVC over zinc-coated steel as specified. All barbs must consist of four points and spacing of barbs must be at 5- inch (+1- inch) centers. Barbed Wire Material Specifications Barbed wire must be in accordance to ASTM A121 and ASTM F1665\. See Appendix A for barbed wire support configurations. Barbed Tape/Concertina Barbed-tape concertina is a commercially manufactured wire coil constructed of high strength- steel barbed wire that is clipped together at intervals to form a single coil or double coil. The single coil must be a minimum of 2 feet in diameter and extend at least 50 feet without permanent distortion. Double coil must be 24/30 inch and extend at least 50 feet without permanent distortion. Barbed tape concertina may be added to the top and, in some cases, to the bottom to increase the level of protection. Barbed tape concertina must be secured at a minimum interval of 18 inches along the fence fabric to the top barbed wire strand and a maximum gap of 2 inches must be maintained between the bottom barbed wire and the top of the chain-link fabric. After use, barbed tape concertina may be recoiled and reused without distortion. For additional protection, barbed tape concertina may be installed between the Y configuration of the outriggers. Barbed Tape/Concertina Material Specifications Barbed tape concertina must be in accordance to ASTM F1911 and ASTM F1910\. See Appendix A barbed tape configurations. Gates NOTE: The gate frames and intermediate braces indicated are adequate for gate sizes less than or equal to 8 feet high and 14 feet wide. Gate configurations larger than 8 feet high and 14 feet wide require special design consideration. Figure 9.3.22 Single Swing Gate Single Swing Gates For swing gates, the cable must be looped around the gatepost, the gate frame upright, and through the fence cable loop. Cable must be strung across the inside of the gate leaf and fastened around the vertical gate frame upright and fabric tension bar midway above the road surface. The cable must be terminated with a swaged loop or wire rope clamp around the gatepost to interconnect with the gate cable barrier system. All cable ends must be looped and terminated with either four wire rope clamps or hydraulically swaged wire rope fittings. Remove sheathing on covered cables at connections so that the connections can be properly made and rated. Design single swing gates to match fence fabric height, with an additional 1 ft of three strand barbed wire added to the height if barb wire is part of the fence structure. The gate opening should not exceed a width of 14 ft. See ASTM F900 for additional gate requirements. Gate Posts Provide a gate post for supporting each gate leaf as follows: Up to 6-feet wide: DN75 2.875-inch O.D. pipe \[Grade A weighing 5.79 pounds per linear foot.\] Or \[Grade B weighing 4.64 pounds per linear foot.\] Over 6 feet wide and up to 13 feet wide: DN75 2.875-inch O.D. pipe \[Grade A weighing 5.79 pounds per linear foot.\] Or \[Grade B weighing 4.64 pounds per linear foot.\] Over 13-feet and up to 18-feet wide: Provide DN150 6.625-inch O.D. pipe weighing 18.97 pounds per linear foot. Over 8-feet wide: Provide DN220 8.625-inch O.D. pipe weighing 24.70 pounds per linear foot Installation: Standards for security fencing installation: Posts shall be placed plumb and in alignment at minimum intervals as shown in Appendix A. Ground surface irregularities along the fence line shall be eliminated to the extent necessary to maintain less than 2-inch ground clearance between the bottom of the fabric and the existing grade. Irregularities in ground surface causing a deviation from clearance range must be filled and compacted. End posts and corner posts and those post immediately adjacent to them shall be set in concrete. Posts shall be set in concrete to a d 

<!-- mobian-agent-ad sponsored="true" id="188e83d0-ad92-41ff-8049-423a4df35809" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/security-and-protection/security-systems?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/e43187e2e40f4310953ae80b110262b6/view)

[More from United States Department of the Army posted in February 2024](/dept%5Fof%5Fthe%5Farmy/archive/2024-02)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Albeni Falls Project Fencing","description":"*Note: See attached Statement of Work \u0026 Request For Quote for complete project details. Scope of Work Albeni Falls Project Fencing Contract Albeni Falls Dam, Idaho General Information 1. General: This is a non-personal requirement to provide services consisting of repair, replacement and/or newly constructing fencing at the Albeni Falls Dam Project. The project office is located at 2376 E Highway 2, Oldtown Idaho, 83822. The Government shall not exercise any supervision or control over the contractor. Subcontractors shall be accountable solely to the Contractor who, in turn is responsible to the Government. 1.1 Description /Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, parts, supervision, and other items to accomplish this non-personal services requirement necessary to perform the replacement/construction as defined in this Statement of Work (SOW). The contractor shall perform to the standards in this contract. 1.2 Background: The United States Army Corps of Engineers manages the Albeni Falls Powerhouse. It is their responsibility to ensure protection, integrity, and stewardship of public lands and infrastructure under their jurisdiction. A part of the management requires proactive inspection and replacement/reinforcement of boundary identification such as fences, line signage, blazing, clearing, and survey monuments to ensure boundary lines are clearly defined and visible to adjacent properties, which is helpful in preventing encroachments and trespasses. Currently there are areas in and around the powerhouse where no fencing currently exists, areas which have been damaged and need repaired, and areas not designed to required security standards. Fencing work is needed at: Albeni Falls Dam Project Powerhouse 2376 E. Highway 2 Oldtown, Idaho 83822 1.3 Principal Items to be Accomplished: All work must be accomplished in accordance with the material and installation standards found in sections 1.3.1 and 1.3.2 of this contract. Installation details found in Technical Exhibit 8, must also be followed. Base Bid Item 0001 Powerhouse Repairs Near Transformer Yard Refer to Technical Exhibits 1a and 1b. Technical Exhibit 1a: Part A: Replace vertical barbed wire with two (2) perpendicular 3 chain link panels with 7 fabric height. Install 18 diameter strand of razor wire vertically along inside edge of newly installed chain link panel nearest Part B. Part B: Add 18 razor wire on inside edge of fence above top horizontal rail. See red line on Technical Exhibit 1a for location. Length is 20. Gate: Extend height of gate 14 and extend fabric to account for additional gate height. Reinstall 3 strands of barbed wire at top of gate. Gate is 3.5 wide. Technical Exhibit 1b: Part C: Raise end post 20 as represented by red cylinder on Technical Exhibit 1b. Replace all barbed wire and terminate barbed wire at end posts, not outriggers. Replace vertical barbed wire that hangs over cliff edge with a minimum of a 4 wide by 6 tall, cantilevered chain link panel. Add 18 razor wire along entire length of inside edge of barbed wire and outriggers and down the side of the newly installed chain link panel that hangs over the cliff edge. Length of fence is 30. Note that fall protection is required when working in the area near the cliff edge. An accident prevention plan, fall protection plan, and activity hazard analysis is required to be submitted for government approval prior to start of work. Examples of these documents can be found in the EM 385-1-1. Base Bid Item 0002 Powerhouse Repairs Near Entrance Gate Refer to Technical Exhibit 2. Install new 18 diameter razor wire vertically at slide gate on end closest to the powerhouse. See red rectangle on Technical Exhibit 2 for location. Razor wire shall extend from the conduit mounted on the vertical concrete wall to the top of the security gate. Total length of razor wire is 12. Note that fall protection is required when working in the area with fall hazard. An accident prevention plan, fall protection plan, and activity hazard analysis is required to be submitted for government approval prior to start of work. Examples of these documents can be found in the EM 385-1-1. Base Bid Item 0003 Powerhouse Repairs Near Spillway Side of Island Refer to Technical Exhibit 3. Install (1) 10 section of security fence with 8 fabric, (1) end post, outriggers, and barbed wire per security fence specifications. Tie this portion of fence into the existing fence located on the spillway side of the island near the spillway gate maintenance pit. A 4 long section of fence is also required on the downhill side and running perpendicular to the newly installed fence to block the opening between the new fence section and the spillways concrete structure. Install 18 diameter razor wire on any portion that does not adequately deter climbing over fence. Follow security fence specifications for construction and installation. Base Bid Item...","url":"https://matchawards.com/dept_of_the_army/posts/112007581721776242","identifier":"W912DW24Q0013","category":"238990 - All Other Specialty Trade Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"5660 - FENCING, FENCES, GATES AND COMPONENTS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"3.2 Security Systems","url":"https://matchawards.com/categories/security-and-protection/security-systems"}],"availabilityStarts":"2024-02-27","availabilityEnds":"2024-03-08","validThrough":"2024-03-08T23:59:59-05:00","areaServed":"Oldtown, 83822","sameAs":"https://sam.gov/opp/e43187e2e40f4310953ae80b110262b6/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```

