<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/111735788763351197" -->

---
title: Air Ejector, Steam Ejector or Vacuum Tank System, Wind-Tunnel… | Closed - MatchAwards
description: Air Ejector, Steam Ejector or Vacuum Tank System, Wind-Tunnel Heater. United States Department of the Army. Solicitation W15BW9-24-X-OZ3N. NAICS 333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing. Deadline 2024-01-31. INTRODUCTION: This is a Sources Sought (SS) issued by the Army...
canonical: https://matchawards.com/dept_of_the_army/posts/111735788763351197
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Air Ejector, Steam Ejector or Vacuum Tank System, Wind-Tunnel… | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/111735788763351197
og:description: Air Ejector, Steam Ejector or Vacuum Tank System, Wind-Tunnel Heater. United States Department of the Army. Solicitation W15BW9-24-X-OZ3N. NAICS 333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing. Deadline 2024-01-31. INTRODUCTION: This is a Sources Sought (SS) issued by the Army...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Air Ejector, Steam Ejector or Vacuum Tank System, Wind-Tunnel Heater

Status

Closed, the response deadline passed on Jan 31, 2024

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

PICATINNY ARSENAL, USA

Notice type

Sources Sought

Solicitation number

W15BW9-24-X-OZ3N

NAICS

[333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing](/groups/476)

PSC

2825 - STEAM TURBINES AND COMPONENTS

Posted

2024-01-10

Deadline

2024-01-31

## Description

INTRODUCTION: This is a Sources Sought (SS) issued by the Army Combat Capabilities Development Command (DEVCOM), Armaments Center (AC), Munitions Engineering & Technology Center (METC) and Aeroballistics Division. The effort involves TWO potential contracts, and is for two opportunities: The first contract is for an air ejector, steam ejector or vacuum tank system capable of drawing near vacuum conditions. The second contract is for a wind tunnel heater. The gas is expected to drop to temperatures that cause air to liquify. The contracts are for an effort that would enhance the Picatinny wind tunnel facility in building 266 and provide hypersonic testing capabilities. Responders to this SS notice are asked to provide statements with the following information related to meeting requirements: For the First Potential Contract: A narrative explaining the companys background, and past/current experience relevant to furnishing and installing any of the aforementioned systems that can create exit conditions of -14.5 PSI (\~10 torr or less) for 9-inch test section wind tunnel. There is 120,000 gallons of air storage (rated 190Psi) available to drive the system. Compressors of the current wind tunnel facility operate at no more than 350 PSI. If a vacuum tank system is suggested, the facility will require the option to switch exit pressure to barometric pressure to support lower speed wind tunnels. The system must be able to withstand temperatures as high as The outlet temperature of the gas for -14.5 PSI case will be 800F The outlet temperature of the gas for -13.0 PSI case will be 620F Ability to provide training on maintenance, safety, and other handling requirements of the system. For the Second Potential Contract: A narrative explaining the companys background, and past/current experience relevant to furnishing and installing wind tunnel heaters. The target temperature range required would be between 500F for a Mach 5.0 condition to 800F for a Mach 6.5 condition. If temperatures can exceed 800F, that would provide margin for the system to accommodate future higher velocity testing. There are two flow rates for given outlet (near vacuum conditions) of the air moving through the system. The flow rate must be sustainable for a minimum of 40 seconds. For an outlet pressure of -14.5 PSI: flow rate: 1.8 kg/s For an outlet pressure of -13.0 PSI: flow rate: 3.2 kg/s Ability to provide training on maintenance, safety, and other handling requirements of the system. This is a SS for market research purposes. Any response to this SS is at the sole-discretion of the contractor. No remittance payment will be made for any information sent in response to this SS. Information submitted in response to this SS may be used for procurement planning purposes. The information received by the Government will not be released to third parties. Interested parties should be cognizant of the beta.sam.gov portal, and of the acquisition process to ensure responsiveness to any opportunities related to issuance of a formal solicitation. The website for Beta.Sam is as follows https://sam.gov/. Currently, a formal solicitation is not definitive. All responses to this SS shall be unclassified. Request that all responses included the following information: Filly Company Name (Legal Entity): Cage Code: Website (if applicable): Contact Information: Business Size Status. 

<!-- mobian-agent-ad sponsored="true" id="9331be2f-4163-462a-bf4a-f9513c91c031" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


[Source notice](https://sam.gov/opp/ca0457e3c42d4fd8865ca68294d50981/view)

[More from United States Department of the Army posted in January 2024](/dept%5Fof%5Fthe%5Farmy/archive/2024-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Air Ejector, Steam Ejector or Vacuum Tank System, Wind-Tunnel Heater","description":"INTRODUCTION: This is a Sources Sought (SS) issued by the Army Combat Capabilities Development Command (DEVCOM), Armaments Center (AC), Munitions Engineering \u0026 Technology Center (METC) and Aeroballistics Division. The effort involves TWO potential contracts, and is for two opportunities: The first contract is for an air ejector, steam ejector or vacuum tank system capable of drawing near vacuum conditions. The second contract is for a wind tunnel heater. The gas is expected to drop to temperatures that cause air to liquify. The contracts are for an effort that would enhance the Picatinny wind tunnel facility in building 266 and provide hypersonic testing capabilities. Responders to this SS notice are asked to provide statements with the following information related to meeting requirements: For the First Potential Contract: A narrative explaining the companys background, and past/current experience relevant to furnishing and installing any of the aforementioned systems that can create exit conditions of -14.5 PSI (~10 torr or less) for 9-inch test section wind tunnel. There is 120,000 gallons of air storage (rated 190Psi) available to drive the system. Compressors of the current wind tunnel facility operate at no more than 350 PSI. If a vacuum tank system is suggested, the facility will require the option to switch exit pressure to barometric pressure to support lower speed wind tunnels. The system must be able to withstand temperatures as high as The outlet temperature of the gas for -14.5 PSI case will be 800F The outlet temperature of the gas for -13.0 PSI case will be 620F Ability to provide training on maintenance, safety, and other handling requirements of the system. For the Second Potential Contract: A narrative explaining the companys background, and past/current experience relevant to furnishing and installing wind tunnel heaters. The target temperature range required would be between 500F for a Mach 5.0 condition to 800F for a Mach 6.5 condition. If temperatures can exceed 800F, that would provide margin for the system to accommodate future higher velocity testing. There are two flow rates for given outlet (near vacuum conditions) of the air moving through the system. The flow rate must be sustainable for a minimum of 40 seconds. For an outlet pressure of -14.5 PSI: flow rate: 1.8 kg/s For an outlet pressure of -13.0 PSI: flow rate: 3.2 kg/s Ability to provide training on maintenance, safety, and other handling requirements of the system. This is a SS for market research purposes. Any response to this SS is at the sole-discretion of the contractor. No remittance payment will be made for any information sent in response to this SS. Information submitted in response to this SS may be used for procurement planning purposes. The information received by the Government will not be released to third parties. Interested parties should be cognizant of the beta.sam.gov portal, and of the acquisition process to ensure responsiveness to any opportunities related to issuance of a formal solicitation. The website for Beta.Sam is as follows https://sam.gov/. Currently, a formal solicitation is not definitive. All responses to this SS shall be unclassified. Request that all responses included the following information: Filly Company Name (Legal Entity): Cage Code: Website (if applicable): Contact Information: Business Size Status.","url":"https://matchawards.com/dept_of_the_army/posts/111735788763351197","identifier":"W15BW9-24-X-OZ3N","category":"333414 - Heating Equipment (except Warm Air Furnaces) Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"2825 - STEAM TURBINES AND COMPONENTS"}],"availabilityStarts":"2024-01-10","availabilityEnds":"2024-01-31","validThrough":"2024-01-31T23:59:59-05:00","sameAs":"https://sam.gov/opp/ca0457e3c42d4fd8865ca68294d50981/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

