<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/107699975016493920" -->

---
title: POL Tank Inspection - Youngstown (YNG) | Closed - MatchAwards
description: POL Tank Inspection - Youngstown (YNG). United States Department of the Army. Solicitation W9128F22Q0014. NAICS 541990 - All Other Professional, Scientific, and Technical Services. Total small business set-aside. Deadline 2022-02-25. Remove and transfer of 5000 gallons of fuel product. The...
canonical: https://matchawards.com/dept_of_the_army/posts/107699975016493920
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: POL Tank Inspection - Youngstown (YNG) | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/107699975016493920
og:description: POL Tank Inspection - Youngstown (YNG). United States Department of the Army. Solicitation W9128F22Q0014. NAICS 541990 - All Other Professional, Scientific, and Technical Services. Total small business set-aside. Deadline 2022-02-25. Remove and transfer of 5000 gallons of fuel product. The...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# POL Tank Inspection - Youngstown (YNG)

Status

Closed (archived notice)

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

OMAHA, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

W9128F22Q0014

NAICS

[541990 - All Other Professional, Scientific, and Technical Services](/groups/935)

PSC

H391 - INSPECTION- FUELS, LUBRICANTS, OILS, AND WAXES

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2022-01-28

Deadline

2022-02-25

Place of performance

Youngstown, 44501

## Description

Remove and transfer of 5000 gallons of fuel product. The contractor will be responsible to coordinate with environmental and safety authorities having jurisdiction to obtain and execute required permits, manifests, etc. to dispose of any fuel or residual product. Clean the tank and perform an internal AST inspection to also include the visual inspection of the containment area. The contractor shall visually inspect containment for ability to contain the entire contents of the tank in the event of catastrophic failure, assessing for cracks, settlement, and deterioration. Record dimensions of cracks and provide photographic evidence of each deficiency. Tank cleaning shall be done in accordance with UFGS 33 01 50.55\. The tank Inspection shall be in conformance with applicable industry standards API 653, NFPA 30, NFPA 326, UFGS 33 01 50.65, and in compliance with 40 CFR 112, UFC 3-460-01, UFC 3-460-03 and any other applicable federal, state, local, service or host nation requirements. At a minimum, table 8-1 within UFC 3-460-01 shall be followed. Remove and completely replace existing Internal Floating Roof Wiper Seal (foam log, double wiper, etc.) with a new double wiper seal in accordance with UFGS 33 56 21.17 and the IFR manufacturers recommendations; penetration seals in floating pan will also be replaced. Hydrostatically test the containment inlet, basin, line, valve. Visually assess the liner integrity and impermeability where applicable. Each containment drain inlet, drain line and containment drain valve shall be hydrostatically tested to assure the drainage system is liquid tight. The Contractor shall perform a hydrostatic test to ensure the drainpipe and release valve do not leak. The Contractor shall perform a hydrostatic test to ensure the integrity of the inlet sump. Drain Line and Release Valve: Test in accordance with applicable requirements of AWWA C600 for hydrostatic testing. Ensure the release valve is closed and pressurize the end of the pipe within the containment basin sump. Test for leakage by filling the pipe with water and pressurizing to 10 psi using a suitable pump connected to the pipeline. The test pressure shall not vary by more than ±1 psi for the duration of the test. Hold this pressure for no less than 2 hours. If the system does not hold pressure, check the outfall point to see if water is bypassing the valve. Test pressure shall be maintained during the test by adding makeup water through the pressure test pump into the pipeline. Accurately note the amount of makeup water required to maintain pressure during the test. Containment Drain Inlet: Test for leakage by filling the inlet with water to a level at least 1-2 inches above the top of the inlet structure. The inlet shall hold this water for not less than 2 hours with no measurable change in the water level. Provide legible tank stencil or label on tank. Upon completion of the Out-of-Service inspection the contractor shall provide a legible tank stencil or decal, consisting of black letters at least 1 in height, stating the date cleaned and inspected, the contractors name and the name of the contractors personnel supervising the work. Remove any existing stencils displaying previous inspection information. New information shall be provided in the following format: Date Cleaned and Inspected: Day-Month-Year ABC Contracting Supervisor: John Doe Provide Teleconference out briefing prior to closing the tank. The Contractor shall be responsible to establish a report of findings and coordinate a teleconference after the inspection is complete and at least 24 hours prior to placing tank back in service. This teleconference will review deficiencies found during the inspection with the Government making the final decision on whether to place this tank back into service. The Contractor can use Attachment E- API OUT-OF-SERVICE TELECON BRIEFING TEMPLATE or their own format however this document shall include the next recommended inspection intervals for both In-Service and Out-of-Service Inspection, and State regulated inspection intervals, if applicable. When listing the findings, they shall be categorized as either Mandatory, Short Term or Long Term. Personnel to be included on the call will be identified after award. Complete roundness survey as required per Attachment B. Provide DRAFT and FINAL inspection reports per the attached templates. Provide separate report for each tank inspected. Specify the due date for the next inspection. Include API Std 653 inspector record certificate number and signature. SUTABILITY FOR SERVICE: Evaluate inspection data to determine suitability for continued use. Identify conditions which pose a risk to integrity. Determine a metal loss threshold for mandatory repairs. In the determination of mandatory repairs: a. Use a "first, do no harm" approach to classifying tank repairs. b. Use Desired Service Interval as the time to next inspection unless notified otherwise by the Contracting Officer. c. Use minimum remaining thickness (MRT) no less than 100 mils at the next inspection. d. Do not classify as mandatory repair of conditions which are noncompliant with current standards but are un-related to structural or hydraulic integrity (e.g., gouge, improper weld spacing, weld profile). e. Apply repair determination to individual indications. Do not average across an entire plate or course. 

<!-- mobian-agent-ad sponsored="true" id="b7565067-a4c1-4a36-9e13-79c9d0cb27a8" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Nicole Parker

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/a06340c22c094355b0f6078142294601/view)

[More from United States Department of the Army posted in January 2022](/dept%5Fof%5Fthe%5Farmy/archive/2022-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)

```json
{"@context":"https://schema.org","@type":"Demand","name":"POL Tank Inspection - Youngstown (YNG)","description":"Remove and transfer of 5000 gallons of fuel product. The contractor will be responsible to coordinate with environmental and safety authorities having jurisdiction to obtain and execute required permits, manifests, etc. to dispose of any fuel or residual product. Clean the tank and perform an internal AST inspection to also include the visual inspection of the containment area. The contractor shall visually inspect containment for ability to contain the entire contents of the tank in the event of catastrophic failure, assessing for cracks, settlement, and deterioration. Record dimensions of cracks and provide photographic evidence of each deficiency. Tank cleaning shall be done in accordance with UFGS 33 01 50.55. The tank Inspection shall be in conformance with applicable industry standards API 653, NFPA 30, NFPA 326, UFGS 33 01 50.65, and in compliance with 40 CFR 112, UFC 3-460-01, UFC 3-460-03 and any other applicable federal, state, local, service or host nation requirements. At a minimum, table 8-1 within UFC 3-460-01 shall be followed. Remove and completely replace existing Internal Floating Roof Wiper Seal (foam log, double wiper, etc.) with a new double wiper seal in accordance with UFGS 33 56 21.17 and the IFR manufacturers recommendations; penetration seals in floating pan will also be replaced. Hydrostatically test the containment inlet, basin, line, valve. Visually assess the liner integrity and impermeability where applicable. Each containment drain inlet, drain line and containment drain valve shall be hydrostatically tested to assure the drainage system is liquid tight. The Contractor shall perform a hydrostatic test to ensure the drainpipe and release valve do not leak. The Contractor shall perform a hydrostatic test to ensure the integrity of the inlet sump. Drain Line and Release Valve: Test in accordance with applicable requirements of AWWA C600 for hydrostatic testing. Ensure the release valve is closed and pressurize the end of the pipe within the containment basin sump. Test for leakage by filling the pipe with water and pressurizing to 10 psi using a suitable pump connected to the pipeline. The test pressure shall not vary by more than ±1 psi for the duration of the test. Hold this pressure for no less than 2 hours. If the system does not hold pressure, check the outfall point to see if water is bypassing the valve. Test pressure shall be maintained during the test by adding makeup water through the pressure test pump into the pipeline. Accurately note the amount of makeup water required to maintain pressure during the test. Containment Drain Inlet: Test for leakage by filling the inlet with water to a level at least 1-2 inches above the top of the inlet structure. The inlet shall hold this water for not less than 2 hours with no measurable change in the water level. Provide legible tank stencil or label on tank. Upon completion of the Out-of-Service inspection the contractor shall provide a legible tank stencil or decal, consisting of black letters at least 1 in height, stating the date cleaned and inspected, the contractors name and the name of the contractors personnel supervising the work. Remove any existing stencils displaying previous inspection information. New information shall be provided in the following format: Date Cleaned and Inspected: Day-Month-Year ABC Contracting Supervisor: John Doe Provide Teleconference out briefing prior to closing the tank. The Contractor shall be responsible to establish a report of findings and coordinate a teleconference after the inspection is complete and at least 24 hours prior to placing tank back in service. This teleconference will review deficiencies found during the inspection with the Government making the final decision on whether to place this tank back into service. The Contractor can use Attachment E- API OUT-OF-SERVICE TELECON BRIEFING TEMPLATE or their own format however this document shall include the next recommended inspection intervals for both In-Service and Out-of-Service Inspection, and State regulated inspection intervals, if applicable. When listing the findings, they shall be categorized as either Mandatory, Short Term or Long Term. Personnel to be included on the call will be identified after award. Complete roundness survey as required per Attachment B. Provide DRAFT and FINAL inspection reports per the attached templates. Provide separate report for each tank inspected. Specify the due date for the next inspection. Include API Std 653 inspector record certificate number and signature. SUTABILITY FOR SERVICE: Evaluate inspection data to determine suitability for continued use. Identify conditions which pose a risk to integrity. Determine a metal loss threshold for mandatory repairs. In the determination of mandatory repairs: a. Use a \"first, do no harm\" approach to classifying tank repairs. b. Use Desired Service Interval as the time to next inspection unless notified otherwise by the Contracting...","url":"https://matchawards.com/dept_of_the_army/posts/107699975016493920","identifier":"W9128F22Q0014","category":"541990 - All Other Professional, Scientific, and Technical Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H391 - INSPECTION- FUELS, LUBRICANTS, OILS, AND WAXES"}],"availabilityStarts":"2022-01-28","availabilityEnds":"2022-02-25","areaServed":"Youngstown, 44501","sameAs":"https://sam.gov/opp/a06340c22c094355b0f6078142294601/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```