<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/107405534870308784" -->

---
title: API 653 Tank Cleaning and Inspection Charleston AFB, South… | Closed - MatchAwards
description: API 653 Tank Cleaning and Inspection Charleston AFB, South Carolina. United States Department of the Army. Solicitation W9128F21Q0089. NAICS 541990 - All Other Professional, Scientific, and Technical Services. Total small business set-aside. Deadline 2021-11-08. Remove and transfer of 5,000...
canonical: https://matchawards.com/dept_of_the_army/posts/107405534870308784
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: API 653 Tank Cleaning and Inspection Charleston AFB, South… | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/107405534870308784
og:description: API 653 Tank Cleaning and Inspection Charleston AFB, South Carolina. United States Department of the Army. Solicitation W9128F21Q0089. NAICS 541990 - All Other Professional, Scientific, and Technical Services. Total small business set-aside. Deadline 2021-11-08. Remove and transfer of 5,000...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# API 653 Tank Cleaning and Inspection Charleston AFB, South Carolina

Status

Closed (archived notice)

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

OMAHA, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

W9128F21Q0089

NAICS

[541990 - All Other Professional, Scientific, and Technical Services](/groups/935)

PSC

H391 - INSPECTION- FUELS, LUBRICANTS, OILS, AND WAXES

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2021-12-07

Deadline

2021-11-08

Place of performance

Charleston AFB, 29404

## Description

Remove and transfer of 5,000 gallons of fuel product. Clean the tank and perform an internal AST inspection to also include the visual inspection of the containment area. The contractor shall visually inspect containment for ability to contain the entire contents of the tank in the event of catastrophic failure, assessing for cracks, settlement, and deterioration. Record dimensions of cracks and provide photographic evidence of each deficiency. Hydrostatically test the containment inlet, basin, line, valve. Visually assess the liner integrity and impermeability where applicable. Each containment drain inlet, drain line and containment drain valve shall be hydrostatically tested to assure the drainage system is liquid tight. The Contractor shall perform a hydrostatic test to ensure the drainpipe and release valve do not leak. The Contractor shall perform a hydrostatic test to ensure the integrity of the inlet sump. Drain Line and Release Valve. The Contractor shall perform a hydrostatic test to ensure the drainpipe and release valve do not leak. Test in accordance with applicable requirements of AWWA C600 for hydrostatic testing. Ensure the release valve is closed and pressurize the end of the pipe within the containment basin sump. Test for leakage by filling the pipe with water and pressurizing to 10 psi using a suitable pump connected to the pipeline. The test pressure shall not vary by more than ±1 psi for the duration of the test. Hold this pressure for not less than 2 hours. If the system does not hold pressure, check the outfall point to see if water is bypassing the valve. Test pressure shall be maintained during the test by adding makeup water through the pressure test pump into the pipeline. Accurately note the amount of makeup water required to maintain pressure during the test. Containment Drain Inlet. The Contractor shall perform a hydrostatic test to ensure the integrity of the inlet sump. Test for leakage by filling the inlet with water to a level at least 1-2 inches above the top of the inlet structure. The inlet shall hold this water for not less than 2 hours with no measurable change in the water level. Provide legible tank stencil or label on tank. Upon completion of the Out-of-Service inspection the contractor shall provide a legible tank stencil or decal, consisting of black letters at least 1 in height, stating the date cleaned and inspected, the contractors name and the name of the contractors personnel supervising the work. Remove any existing stencils displaying previous inspection information. New information shall be provided in the following format: Date Cleaned and Inspected: Day-Month-Year ABC Contracting Supervisor: John Doe Provide Teleconference out briefing prior to closing up the tank. The Contractor shall be responsible to establish a report of findings and coordinate a teleconference after the inspection is complete and at least 24 hours prior to placing tank back in service. This teleconference will review deficiencies found during the inspection with the Government making the final decision on whether or not to place this tank back into service. The Contractor can use Attachment H- API OUT-OF-SERVICE TELECON BRIEFING TEMPLATE or their own format however this document shall include the next recommended inspection intervals for both In-Service and Out-of-Service Inspection, and State regulated inspection intervals, if applicable. Also when listing the findings they shall be categorized as either Mandatory, Short Term or Long Term. Please coordinate with the following individuals in addition to on Installation personnel: Provide DRAFT and FINAL inspection reports per the attached templates 28 October 2021: Amendment issued to include the correct tank dimension in attachment B. Amendment documents are included in the attachments/links tab in this solicitation. Please submit proposals by the new due date. 28 October 2021: Wrong proposal due date entered in SAM. Changed from 11 Nov to 8 Nov. 

<!-- mobian-agent-ad sponsored="true" id="b1985e92-5f18-4196-9eef-3f42a950110f" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Steve Engen
* Denise M. Fricke

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/8e0097d7713642aa9f3740012e75c59f/view)

[More from United States Department of the Army posted in December 2021](/dept%5Fof%5Fthe%5Farmy/archive/2021-12)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)

```json
{"@context":"https://schema.org","@type":"Demand","name":"API 653 Tank Cleaning and Inspection Charleston AFB, South Carolina","description":"Remove and transfer of 5,000 gallons of fuel product. Clean the tank and perform an internal AST inspection to also include the visual inspection of the containment area. The contractor shall visually inspect containment for ability to contain the entire contents of the tank in the event of catastrophic failure, assessing for cracks, settlement, and deterioration. Record dimensions of cracks and provide photographic evidence of each deficiency. Hydrostatically test the containment inlet, basin, line, valve. Visually assess the liner integrity and impermeability where applicable. Each containment drain inlet, drain line and containment drain valve shall be hydrostatically tested to assure the drainage system is liquid tight. The Contractor shall perform a hydrostatic test to ensure the drainpipe and release valve do not leak. The Contractor shall perform a hydrostatic test to ensure the integrity of the inlet sump. Drain Line and Release Valve. The Contractor shall perform a hydrostatic test to ensure the drainpipe and release valve do not leak. Test in accordance with applicable requirements of AWWA C600 for hydrostatic testing. Ensure the release valve is closed and pressurize the end of the pipe within the containment basin sump. Test for leakage by filling the pipe with water and pressurizing to 10 psi using a suitable pump connected to the pipeline. The test pressure shall not vary by more than ±1 psi for the duration of the test. Hold this pressure for not less than 2 hours. If the system does not hold pressure, check the outfall point to see if water is bypassing the valve. Test pressure shall be maintained during the test by adding makeup water through the pressure test pump into the pipeline. Accurately note the amount of makeup water required to maintain pressure during the test. Containment Drain Inlet. The Contractor shall perform a hydrostatic test to ensure the integrity of the inlet sump. Test for leakage by filling the inlet with water to a level at least 1-2 inches above the top of the inlet structure. The inlet shall hold this water for not less than 2 hours with no measurable change in the water level. Provide legible tank stencil or label on tank. Upon completion of the Out-of-Service inspection the contractor shall provide a legible tank stencil or decal, consisting of black letters at least 1 in height, stating the date cleaned and inspected, the contractors name and the name of the contractors personnel supervising the work. Remove any existing stencils displaying previous inspection information. New information shall be provided in the following format: Date Cleaned and Inspected: Day-Month-Year ABC Contracting Supervisor: John Doe Provide Teleconference out briefing prior to closing up the tank. The Contractor shall be responsible to establish a report of findings and coordinate a teleconference after the inspection is complete and at least 24 hours prior to placing tank back in service. This teleconference will review deficiencies found during the inspection with the Government making the final decision on whether or not to place this tank back into service. The Contractor can use Attachment H- API OUT-OF-SERVICE TELECON BRIEFING TEMPLATE or their own format however this document shall include the next recommended inspection intervals for both In-Service and Out-of-Service Inspection, and State regulated inspection intervals, if applicable. Also when listing the findings they shall be categorized as either Mandatory, Short Term or Long Term. Please coordinate with the following individuals in addition to on Installation personnel: Provide DRAFT and FINAL inspection reports per the attached templates 28 October 2021: Amendment issued to include the correct tank dimension in attachment B. Amendment documents are included in the attachments/links tab in this solicitation. Please submit proposals by the new due date. 28 October 2021: Wrong proposal due date entered in SAM. Changed from 11 Nov to 8 Nov.","url":"https://matchawards.com/dept_of_the_army/posts/107405534870308784","identifier":"W9128F21Q0089","category":"541990 - All Other Professional, Scientific, and Technical Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H391 - INSPECTION- FUELS, LUBRICANTS, OILS, AND WAXES"}],"availabilityStarts":"2021-12-07","availabilityEnds":"2021-11-08","areaServed":"Charleston AFB, 29404","sameAs":"https://sam.gov/opp/8e0097d7713642aa9f3740012e75c59f/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```