ClickCease National Guard Bureau, Architect and Engineering Indefinite… | Closed - MatchAwards

National Guard Bureau, Architect and Engineering Indefinite Delivery Indefinite Quantity Contract for Vertical and Horizontal Projects for Hawaii

Status
Closed (archived notice)
Agency
United States Department of the Army
Office
HONOLULU, USA
Notice type
Solicitation
Solicitation number
W912J6-22-R-0001
NAICS
541330 - Engineering Services
PSC
C211 - ARCHITECT AND ENGINEERING- GENERAL: LANDSCAPING, INTERIOR LAYOUT, AND DESIGNING
Category
Construction Related Services (4.2)
Set-aside
Partial Small Business Set-Aside (FAR 19.5)
Posted
2021-11-05
Deadline
2021-11-12

Description

5-November 2021: See attached Amendment 01. All changes to the Synopsis are in the document attached "W912J6-22-R-0001 Synopsis - Amendment 01 20211105". Changes to the synopsis are shown as stricken text and highlighted text. Please see important note regarding acknowledgement of amendments. The proposal due date is extended to 12 Nov 2021 03:00 pm HST. 4 November 2021: See attached W912J6-22-R-0001 - RFI Responses 2 - 7 (04 Nov 21). An amendment will be issued soon to incorporate changes resulting in RFI 3 and other important changes. 20 October 2021: See attached W912J6-22-R-0001 - RFI Responses 1 (19 Oct 21) 8 October 2021: See attached W912J6-22-R-0001 - Synopsis Attachment - Combined Q&As 20211008 INDEFINITE DELIVERY TYPE ARCHITECT ENGINEER (A-E) CONTRACT FOR THE NATIONAL GUARD BUREAU IN SUPPORT OF THE AIR AND ARMY NATIONAL GUARD VERTICAL & HORIZONTAL CONSTRUCTION PROGRAMS THROUGHOUT HAWAII CONTRACT INFORMATION: The National Guard Bureau is soliciting for Non-Personal Architect-Engineer (A-E) Services in accordance with Public Law 92-582 (Selection of A-E Statute) and Federal Acquisition Regulation (FAR) Part 36. As a result of this announcement, the National Guard Bureau intends to award a target of Three (3) Indefinite Delivery Indefinite Quantity (IDIQ) contracts with one (1) solicited as Other than Small Business (i.e. unrestricted) and two (2) reserved for small business concerns, if there is adequate completion in accordance with FAR 36.602. These contracts will provide Vertical and Horizontal A-E services in support of Air National Guard (ANG) and Army National Guard (ARNG) mission requirements located throughout Hawaii, which includes the Islands of Oahu, Kauai, Molokai, Maui, and Hawaii in the State of Hawaii. The total capacity of the three (3) contracts is $40M. This capacity will be shared among all firms. The Government may award more contracts within each business category (i.e. Small Business or Other than Small Business) depending on the source selection decision regarding how many firms are considered the most highly qualified per the 2014 Selection of A&E Contracts Act selection procedures. Each IDIQ will be for a five (5) year ordering period from the date of award of all contracts. Guidelines for competition of task orders: Non-Complex A-E task order requirements with a Programmed Amount (PA) less than $3M must be set-aside for competition among the reserved Small Business Firms. Non-Complex A-E task order requirements with a Programmed Amount (PA) above $3M may be competed among all IDIQs Complex A-E task order requirements with a Programmed Amount (PA) less than $3M may be competed among all IDIQs Complex A-E task order requirements with a Programmed Amount (PA) above $3M may be reserved to the Unrestricted IDIQ The following definitions apply to the items above for Vertical requirements: Complex work is defined as projects that involve multiple concurrent disciplines or considers unique design solutions considering size and scope as determine by the Government. Examples: SCIF, Hangars, Major Building Renovations. Non-complex work is defined as work that involves limited disciplines or design solutions that are not considered unique. Examples: Administrative facilities and maintenance facilities (non-Hangars). The following definitions apply to the Horizontal requirements: Complex work is defined as projects that include uncommon characteristics (such as control systems, arresting systems, new construction airfield pavements, micro-grids, utility stations, or other similar uncommon characteristics) or work that requires significant planning or siting. Non-Complex is defined as any requirement that does not fit the definition of Complex. All firms responding to the announcement will be required to identify which category they are submitting. All firms will be required to state the words, "Small Business", or "Other than Small Business" after the solicitation number in PART I, A, Block 3 of Standard Form 330. Firms will be required to submit a separate SF 330 for each category in which the firm wants consideration. No one firm will receive more than one award as a result of this solicitation. The North American Industry Classification System (NAICS) code for this action is 541330. The Small Business size standard is $16.5M in average annual receipts of a business’s latest five (5) fiscal years. Small businesses are encouraged to team with other businesses. These are not requirements contracts. The contract will consist of two (2) ordering periods; one (1) ordering period will be for five (5) years and one (1) optional ordering period for six months with a total contract ceiling of $45M for the entire program. The total contract period shall not exceed five (5) calendar years and an option to extend six (6) additional months. Task orders will be primarily for projects with a construction value typically between $100K and $30M, however, as required, larger and/or smaller projects may be executed. The minimum total fee guaranteed to each contract awardee is $2,500.00. Order limitations are as follows: The Contractor is not obligated to honor (1) any order for a single item above $6M or (2) any order for a combination of items over $8M. Work will be issued by negotiated firm-fixed price task orders. Projects to be designed are not yet determined and funds (except those reserved for the minimum fee guarantee) are not presently available. The selection of A-E firms is based on professional qualifications necessary for the performance of the required services (rather than competitive bidding procedures). All A-E firms are cautioned to review the restrictions of FAR 9.5 Organizational and Consultant Conflicts of Interest and FAR 36.209 Construction Contracts with Architect-Engineer Firms. Any A-E firm that prepares a Design-Build Request for Proposal for a particular project will be restricted from participating in any contract or task order for the Design-Build of that particular project. All interested Architect-Engineers are reminded that, under the provisions of PL 95-507, they will be expected to place subcontracts to the maximum practicable extent consistent with the efficient performance of the contract with small and small disadvantaged firms. Large business firms that intend to pursue an IDIQ contract must convey their intent to meet the minimum small business goals on the SF330, Section C, by identifying subcontracting opportunities with small businesses. Minimum goals for this procurement are: Small Business (all types of small business combined) 14%; Small Disadvantaged Businesses 3%; Woman Owned Small Business 5%; HUBZone Small Business 1%; Veteran-Owned SB 3% and Service Disabled Veteran Owned SB 3% Small Business firms. If selected as the most highly qualified firm, the large business offeror will be required to submit a Small Business Subcontracting Plan following FAR 52.219-9 and DFARS 219.704/705 as a part of the Request for Proposal Package (RFPP). The subcontracting plan will be based on subcontracting dollars. The subcontracting plan is NOT required with the SF330 submittal. Small Business firms that are selected under the Small Business set aside must perform 50 percent of the contract performance by the prime or a similarly situated Small Business subcontractor in accordance with Deviation 2020-O0008. The wages and benefits of service employees (FAR 22.10) performing under this contract must be at least equal to those determined by the Department of Labor under the Service Contract Act. This is a multiple award effort with the most-highly qualified firm in the Small Business group and the most-highly qualified firm in the Unrestricted group receiving their RFPP’s first. Once that process is complete, the next most highly qualified firm will be provided their RFPP, and so on. In accordance with 40 USC 11, Selection of Architect and Engineers, the negotiation process will continue until an agreement is reached and all contracts are awarded. PROJECT INFORMATION: Anticipated A-E services for Hawaii may include but are not be limited to performance of planning, master planning, and program support; A-E investigative and design services including development of construction documents; construction support; engineering and environmental studies, National Environmental Policy Act (NEPA) documentation; investigations and surveys in support of the and Air and Army National Guard Programs. Typical work may include, but is not specifically limited to: A: the preparation of plans, specifications, calculations, and cost estimates; B: the development of cost management, quality control and quality assurance plans; C: construction inspection, testing and management services; D: development of engineering standards; E: preparations for design submissions; F: technical, economic, planning, environmental, value engineering and other studies, analyses, surveys, investigations, and reports; G: development of performance criteria for bridging documents for design build projects; H: development of documents to support various government construction programs; I: commissioning services; J: comprehensive interior design. Services may also include, but are not limited to, a wide variety of professional services in support of projects for administrative, industrial, and support facilities to meet the needs of the National Guard. Various projects may include services associated with National Guard installations/facilities, such as aircraft hangars, corrosion control facilities, aircraft maintenance facilities, SCIF facilities, vehicle maintenance facilities, support equipment maintenance facilities, administrative offices, supply facilities, civil engineering facilities, dormitory buildings, training site facilities, readiness centers (armory), fire stations, security forces facilities, munitions maintenance and storage facilities, communications and electronic maintenance, mobility and aerial port facilities, dining facilities, medical training facilities, roadways, pavements to include airfield, roads, parking lots and sidewalks, utilities (water, sewer, electrical, natural gas, storm drainage), infrastructure, aircraft fuel storage and distribution systems, running tracks, fencing and gates, exterior lighting for parking and airfields, oil water separators, automated record fire ranges, gunnery complex, clear zones, bridges, generator connections for facilities, smart meters, barriers, lightning protection systems, reservoirs, fall protection, fire loops, fuel systems and other support facilities. Additionally, task orders may be issued for support services which require A-E Services as defined in FAR 2.101. SELECTION CRITERIA: The selection criteria are listed below in descending order of importance (first by major criterion and then by each sub-criterion). Criteria A – Professional Qualifications necessary for satisfactory performance of required services (SF330, Part I, Section E): The selected firm must have, either in?house or through consultants, all disciplines listed for this criteria and must provide resumes in Part I, Section E, of the SF330. Resumes shall not exceed two (2) pages each. All engineers, architects and the project manager must have the following in the role they are assigned to on the project team: a Bachelor’s degree, professional registration, and at least five (5) years of relevant experience. The Government may give additional consideration for special training or certifications, additional registration, higher level of education degrees, and/or years of experience that exceeds the five (5) year minimum requirement. (1) Mechanical Engineer; (2) Project Manager; (3) Architect; (4) Electrical Engineer; (5) Structural Engineer; (6) Civil Engineer; (7) Fire Protection Engineer - an individual who is a registered professional engineer (P.E.) within the United States or its territories who has passed the fire protection engineering examination administered by the National Council of Examiners for Engineering and Surveying (NCEES) and has relevant fire protection engineering experience; (8) Communications Specialist with an engineering degree or physical science degree and having a Registered Communications Distribution Design (RCDD) certification; (9) Environmental Engineer or Physical Scientist with experience in NEPA processes; registered engineer or similar registration that includes documented work history, state examination, and state certification board; (10) Surveyor who is a registered professional land surveyor with 5 years of relevant experience (11) Cost Estimator; the cost engineering specialist(s) must be certified by a professional organization, such as the Association for the Advancement of Cost Engineering (AACE), International Costs Engineering Council (ICEC), and Professional Construction Estimators Association (PCEA). The firm's and/or consultant's cost engineering or estimating specialist(s), must be specifically identified and his (their) competence indicated by resume(s). (12) Geotechnical Engineer; (13) Corrosion Engineer Registered National Association of Corrosion Engineers (NACE) Certified Corrosion Specialist NACE Certified Cathodic Protection Specialist (CP-4), or registered professional corrosion engineer with a minimum of five (5) years’ experience; (14) Security/Cyber Security Specialist; the security/cyber security specialist(s) must have minimum of five (5) years of experience in cybersecurity of facility related control systems; (15) Landscape Architect; who is a registered professional landscape architect (16) Interior Designer who is a registered architect with specialized experience in interior design and/or state registered interior designer and/or National Council for Interior Design Qualification (NCIDQ) certified interior designer; (17) Geologist; with a Geology or Physical Scientist Bachelor’s degree, a Certified Professional Geologist (CPG) from the American Institute of Professional Geologist (AIPG) or a registered Professional Geologist license and at least 8 years of professional experience as a geologist. **Note that the government will consider more favorably team members with Design Build Institute of America (DBIA) certification and Building Information Modeling (BIM) competence certifications. These will be credited with a strength. If an individual will serve in more than one discipline then those disciplines shall be indicated in Block 13, PART I, Section E. Resumes (Section E of the SF 330) must be provided for all disciplines, including consultants. In the resumes under Project Assignments, use the same discipline nomenclature as is used in this announcement. The Government may provide additional consideration to offerors where key personnel worked on relevant projects that demonstrates experience relevant to Criteria B. Criteria B – Specialized Experience and Technical Competence in the type of work required, including, as appropriate, experience in sustainable design, energy conservation, pollution prevention, waste reduction, and the use of recovered materials: (SF330, Part I, Section F). The offeror shall provide a combined maximum of five (5) projects in total within the past six (6) years preceding the date of this announcement for both, the prime firm and subcontractor(s) in PART I, Section F, of the SF330. Examples of projects shall not exceed two (2) pages each. If any portion of the work provided as specialized experience is subcontracted, clearly identify that work as such and provide the required experience of that subcontractor as it relates to work the subcontractor is to perform for this solicitation. If the offeror is a joint venture, each firm shall provide information demonstrating experience relevant to their role on this project. Joint Venture Requirements - Parties wishing to propose as a joint venture must submit, with the Pro Forma documents, an executed copy of the joint venture agreement. The joint venture agreement shall be executed in accordance with FAR 4.102(d). Each joint venture partner shall submit evidence satisfactory to the Contracting Officer that its Board of Directors has approved its participation in the joint venture or by an instrument of similarly binding character in the case of an unincorporated entity. Offerors are reminded that to obtain an award the awardee, to include a joint venture, must be registered in the System for Award Management (SAM) database. Applicable to set aside solicitations: Joint Ventures must meet applicable size standards (See FAR Subpart 19.1). Submit with the proposal any size determination for the Joint Venture entity received from the Small Business Administration. A Joint Venture where-in one party is not a small business may be referred to the Small Business Administration (IAW FAR 19.302 (b)) to determine eligibility. All questions regarding Joint Ventures must be directed to the Small Business Administration (SBA) and not the Contracting Officer. A Project is defined as a single, stand-alone contract and/or a single task order issued under an existing IDIQ contract(s) unless the project included multiple phases and was issued under more than one contractual order. It shall be noted that an IDIQ contract is not a project. Do not combine multiple task orders unrelated to a stand-alone project to create a single project example. Combining multiple task orders under an IDIQ to create a single project will not be compliant with the solicitation criteria, and it will not be evaluated or considered. The contract number or IDIQ number and individual task order number associated with the project in the title must be included for each of the projects. If the project is not 100% complete, note the current percentage and estimated date when the project will be completed for each contract and/or task order. Include the percentage of work self-performed by the prime for each contract and/or task order. Firms shall only submit projects as evidence of experience if those projects are at a minimum beyond B1/65% design submission for Type A/B experience, and at a mininum 50% complete on construction for Type C experience. Include the percentage of work self-performed by the prime for each contract and/or task order. If proposing as a joint venture, ascribe the percentage of work self-performed by each Joint Venture member. The offeror and/or subcontractors must demonstrate experience in the following areas with narrative and by average revenue in part II where indicated. For codes where the work is incidental or small and cannot be broken down, offeror can instead provide an explanation indicating why there is no data: (1) Experience in the design of military projects (Profile Code M05 in Part II), including the production of programming documents, plans and specifications. (2) Design of government and commercial facilities including specific experience designing work meeting the unique requirements presented by island/tropical environments, major weather, wind, and flooding events, humidity, etc... and ways you have mitigated challenges associated with material acquisition delays, available construction technicians and local labor skill levels. (3) Specialized Expertise demonstrating a broad base of knowledge integrating federal requirements to include: Sustainable design experience (Profile Code S11 in Part II) per UFC 1?200?02, High Performance and Sustainable Building Requirements and certified LEED AP; Technical Competence & Experience using DOD UFC and associated Unified Facilities Guide Specifications (UFGS); Design and construction experience conforming to Department of Defense Antiterrorism/Force Protection Construction Standards and DOD Unified Facilities Criteria (UFC 4?010?01), (note that the Government may provide additional consideration for engineers and architects who have attended any DoD Security Engineer Course); Performance of surveying and mapp

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of the Army posted in November 2021

More lists