<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/107020497721473775" -->

---
title: Confocal Raman Chemical Imaging Microscopy System | Closed - MatchAwards
description: Confocal Raman Chemical Imaging Microscopy System. United States Department of the Army. Solicitation W911SR-21-R-SCOP. NAICS 334516 - Analytical Laboratory Instrument Manufacturing. Deadline 2021-09-30. SOURCES SOUGHT (SS) ON BEHALF OF THE COMBAT CAPABILITIES DEVELOPMENT COMMAND, CHEMICAL...
canonical: https://matchawards.com/dept_of_the_army/posts/107020497721473775
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Confocal Raman Chemical Imaging Microscopy System | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/107020497721473775
og:description: Confocal Raman Chemical Imaging Microscopy System. United States Department of the Army. Solicitation W911SR-21-R-SCOP. NAICS 334516 - Analytical Laboratory Instrument Manufacturing. Deadline 2021-09-30. SOURCES SOUGHT (SS) ON BEHALF OF THE COMBAT CAPABILITIES DEVELOPMENT COMMAND, CHEMICAL...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Confocal Raman Chemical Imaging Microscopy System

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

ABERDEEN PROVING GROU, USA

Notice type

Sources Sought

Solicitation number

W911SR-21-R-SCOP

NAICS

[334516 - Analytical Laboratory Instrument Manufacturing](/groups/520)

PSC

6640 - LABORATORY EQUIPMENT AND SUPPLIES

Category

[Test & Measurement Supplies (5.4)](/categories/industrial-products-and-services/test-and-measurement-supplies)

Posted

2021-09-30

Deadline

2021-09-30

## Description

SOURCES SOUGHT (SS) ON BEHALF OF THE COMBAT CAPABILITIES DEVELOPMENT COMMAND, CHEMICAL BIOLOGICAL CENTER (DEVCOM CBC) CONFOCAL RAMAN CHEMICAL IMAGING MICROSCOPY SYSTEM Type: Sources Sought Response Date: 11 August 2021, 12:00 PM Eastern Daylight Time (EDT) INTRODUCTION The Army Contract Command, Aberdeen Proving Ground, Edgewood Contracting Division (ACC APG ECD) on behalf of the U.S. Combat Capabilities Development Command, Chemical Biological Center (DEVCOM CBC) is issuing this sources sought synopsis as a means of conducting market research to identify potential sources having an interest and industry technologies available to provide a confocal raman chemical imaging microscopy system. BASED ON THE RESPONSES TO THIS NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET ASIDE FOR CERTIFIED SMALL BUSINESSES (IN FULL OR IN PART) OR MAY BE PROCURED THROUGH FULL AND OPEN COMPETITION. All Small Business set-aside categories will be considered. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. DISCLAIMER THIS SOURCES SOUGHT IS FOR INFORMATIONAL PURPOSES ONLY. THE RESULTS OF THIS MARKET RESEARCH WILL CONTRIBUTE TO DETERMININE THE METHOD OF PROCUEMENT. THIS IS NOT A REQUEST FOR PROPOSAL (RFP) TO BE SUBMITTED. IT DOES NOT CONSTITUTE A SOLICITATION AND SHALL NOT BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT. RESPONSES IN ANY FORM ARE NOT OFFERS AND THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. NO FUNDS ARE AVAILABLE TO PAY FOR PREPARATION OF RESPONSES TO THIS ANNOUNCEMENT. ANY INFORMATION SUBMITTED BY RESPONDENTS TO THIS TECHNICAL DESCRIPTION IS STRICTLY VOLUNTARY. RESPONSES WILL NOT BE RETURNED TO THE RESPONDER. NOT RESPONDING TO THIS NOTICE DOES NOT PRECLUDE PARTICIPATION IN ANY FUTURE REQUEST FOR QUOTE (RFQ) OR INVITATION FOR BID (IFB) OR RFP, IF ANY ISSUED. IF A SOLICITATION IS RELEASED, IT WILL BE SYNOPSIZED ON THE GOVERNMENT-WIDE POINT OF ENTRY (GPE). IT IS THE RESPONSIBILITY OF POTENTIAL OFFERORS TO MONITOR THE GPE FOR ADDITIONAL INFORMMATION PERTAINING TO THIS REQUIREMENT. ACC ECD is seeking the following information from respondents: REQUIRED CAPABILITIES The Government requires a confocal Raman chemical imaging microscopy system for performing fast, high-resolution Raman chemical imaging microscopy in a chemical fume hood. Due to safety reasons, the operator must minimize the interaction with microscope inside the chemical hood and preferably limit interactions only to placing and removing the samples. The intent of this Sources Sought is to assess the state-of-the art of the technology available that could be applied to meet this requirement. The following requirement MUST be met: 1\. The system will be used inside a chemical fume hood, and therefore it is required that the microscope body be separated from the lasers and spectrometers, which must be fiber coupled with the microscope body. Only the microscope body and its base support will be placed inside the hood. This is to eliminate the possibility of chemical contamination of those parts. The lasers, spectrometers, and associated electronics and miscellaneous components will be placed outside the chemical fume hood. Additional cables can be used to transmit electrical/data signals and power between the microscope in the fume hood and other components outside the fume hood. 2\. The system will be controlled via an included Windows 10 PC with monitor. Software for control of the instrument will be included. The software will also provide a suite of analysis tools including spectral filtering and baseline correction, spectral math, chemical component identification, and chemical image visualization. 3\. The system will include an optical microscope with motorized control and software selection between a minimum of 6 possible objective slots. The motorized system will also switch between white light and Raman spectroscopy measurements, and have motorized control of the field and aperture stops. This will reduce the interaction of an operator with the microscopy assembly. 4\. The microscope will have motorized xyz stage control via software. The z height control should have a step resolution of 10 nm or less, and a minimum total range of 25 mm. The xy control should have a minimum range of 50 mm x 50 mm. The step size for x and y should be 25 nm or less. 5\. The microscope will additionally have a piezo-driven stage cascaded on the main xyz stage. This should have a minimum range of 100 microns x 100 microns in x and y, and 20 microns in z. The resolution of this stage should be better than 0.5 nm in all dimensions. 6\. The system will have lasers with the following laser excitation wavelengths: 532 nm, 633 nm, 785 nm, and 1064 nm. The system will have software-controlled, motorized switching between the laser wavelengths. The lasers shall be coupled into the microscope using single mode, polarization maintaining fibers. Each laser shall have a single longitudinal mode. The lasers shall have the following minimum power outputs: 532 nm, 50 mW; 633 mm, 25 mW; 785 nm, 250 mW; 1064 nm, 400 mW. The system will be able to select the different lasers for coupling to the microscope via software computer control. The laser coupling, signal collection coupling, and signal optimization alignment shall be automated under computer control. 7\. The system will have the capability to automatically control and measure the laser power for each of the lasers via computer software. This should be able to control the power with a precision of 0.1 mW for each laser. 8\. The system will have an integrated calibration lamp that can be controlled via software and can automatically calibrate the wavelengths of the spectrometers used. 9\. Spectrometers used for each of these systems shall be optimized for the corresponding wavelengths. The spectrometers for the laser pairs of 532 nm/633 nm or 633 nm/785nm lasers may be shared. Each spectrometer will include a minimum of two gratings allowing for wide wavelength range and high spectral resolution, respectively. The spectrometer for 532 nm/633 nm will be optimized for sensitivity between 500-800 nm. The spectrometer for 633 nm/785 nm will be optimized for sensitivity between 630-1100 nm. The spectrometer for 1064 nm will be optimized for sensitivity between 1000-1600 nm. The system will be able to switch between the different spectrometers via computer software control with automated optimization and alignment. 10\. The cameras used for performing the spectroscopy measurements will be back-illuminated charge-couple device (CCD cameras) (532 nm, 633 nm, and 785 nm) or Indium-Gallium-Arsenide (InGaAs) CCD cameras (1064 nm) and optimized for each of the individual wavelengths. The same camera may be used for the pairs of 532 nm/633 nm or 633 nm/785nm lasers. The camera will be an electron-multiplying CCD (EM-CCD) for 532 nm/633 nm with a minimum quantum efficiency > 90% at 500 nm with readout up to 1300 spectra/second and thermoelectric cooling to -60 C or below. For 633 nm/785 nm the camera will be a back-illiuminated CCD with a quantum efficiency of >95% at 800 nm and thermoelectric cooling to <60 C. For 1064 nm the camera will be an InGaAs CCD sensor with quantum efficiency >80% from 1000-1600 nm and thermoelectric cooling to 

<!-- mobian-agent-ad sponsored="true" id="658e32f6-19c6-49a1-b607-b95174ab94a7" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/test-and-measurement-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Sheila Ramos
* Brian E Mazen

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/6c4523fb15f04e32a20b8061a7013a76/view)

[More from United States Department of the Army posted in September 2021](/dept%5Fof%5Fthe%5Farmy/archive/2021-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Confocal Raman Chemical Imaging Microscopy System","description":"SOURCES SOUGHT (SS) ON BEHALF OF THE COMBAT CAPABILITIES DEVELOPMENT COMMAND, CHEMICAL BIOLOGICAL CENTER (DEVCOM CBC) CONFOCAL RAMAN CHEMICAL IMAGING MICROSCOPY SYSTEM Type: Sources Sought Response Date: 11 August 2021, 12:00 PM Eastern Daylight Time (EDT) INTRODUCTION The Army Contract Command, Aberdeen Proving Ground, Edgewood Contracting Division (ACC APG ECD) on behalf of the U.S. Combat Capabilities Development Command, Chemical Biological Center (DEVCOM CBC) is issuing this sources sought synopsis as a means of conducting market research to identify potential sources having an interest and industry technologies available to provide a confocal raman chemical imaging microscopy system. BASED ON THE RESPONSES TO THIS NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET ASIDE FOR CERTIFIED SMALL BUSINESSES (IN FULL OR IN PART) OR MAY BE PROCURED THROUGH FULL AND OPEN COMPETITION. All Small Business set-aside categories will be considered. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. DISCLAIMER THIS SOURCES SOUGHT IS FOR INFORMATIONAL PURPOSES ONLY. THE RESULTS OF THIS MARKET RESEARCH WILL CONTRIBUTE TO DETERMININE THE METHOD OF PROCUEMENT. THIS IS NOT A REQUEST FOR PROPOSAL (RFP) TO BE SUBMITTED. IT DOES NOT CONSTITUTE A SOLICITATION AND SHALL NOT BE CONSTRUED AS A COMMITMENT BY THE GOVERNMENT. RESPONSES IN ANY FORM ARE NOT OFFERS AND THE GOVERNMENT IS UNDER NO OBLIGATION TO AWARD A CONTRACT AS A RESULT OF THIS ANNOUNCEMENT. NO FUNDS ARE AVAILABLE TO PAY FOR PREPARATION OF RESPONSES TO THIS ANNOUNCEMENT. ANY INFORMATION SUBMITTED BY RESPONDENTS TO THIS TECHNICAL DESCRIPTION IS STRICTLY VOLUNTARY. RESPONSES WILL NOT BE RETURNED TO THE RESPONDER. NOT RESPONDING TO THIS NOTICE DOES NOT PRECLUDE PARTICIPATION IN ANY FUTURE REQUEST FOR QUOTE (RFQ) OR INVITATION FOR BID (IFB) OR RFP, IF ANY ISSUED. IF A SOLICITATION IS RELEASED, IT WILL BE SYNOPSIZED ON THE GOVERNMENT-WIDE POINT OF ENTRY (GPE). IT IS THE RESPONSIBILITY OF POTENTIAL OFFERORS TO MONITOR THE GPE FOR ADDITIONAL INFORMMATION PERTAINING TO THIS REQUIREMENT. ACC ECD is seeking the following information from respondents: REQUIRED CAPABILITIES The Government requires a confocal Raman chemical imaging microscopy system for performing fast, high-resolution Raman chemical imaging microscopy in a chemical fume hood. Due to safety reasons, the operator must minimize the interaction with microscope inside the chemical hood and preferably limit interactions only to placing and removing the samples. The intent of this Sources Sought is to assess the state-of-the art of the technology available that could be applied to meet this requirement. The following requirement MUST be met: 1. The system will be used inside a chemical fume hood, and therefore it is required that the microscope body be separated from the lasers and spectrometers, which must be fiber coupled with the microscope body. Only the microscope body and its base support will be placed inside the hood. This is to eliminate the possibility of chemical contamination of those parts. The lasers, spectrometers, and associated electronics and miscellaneous components will be placed outside the chemical fume hood. Additional cables can be used to transmit electrical/data signals and power between the microscope in the fume hood and other components outside the fume hood. 2. The system will be controlled via an included Windows 10 PC with monitor. Software for control of the instrument will be included. The software will also provide a suite of analysis tools including spectral filtering and baseline correction, spectral math, chemical component identification, and chemical image visualization. 3. The system will include an optical microscope with motorized control and software selection between a minimum of 6 possible objective slots. The motorized system will also switch between white light and Raman spectroscopy measurements, and have motorized control of the field and aperture stops. This will reduce the interaction of an operator with the microscopy assembly. 4. The microscope will have motorized xyz stage control via software. The z height control should have a step resolution of 10 nm or less, and a minimum total range of 25 mm. The xy control should have a minimum range of 50 mm x 50 mm. The step size for x and y should be 25 nm or less. 5. The microscope will additionally have a piezo-driven stage cascaded on the main xyz stage. This should have a minimum range of 100 microns x 100 microns in x and y, and 20 microns in z. The resolution of this stage should be better than 0.5 nm in all dimensions. 6. The system will have lasers with the following laser excitation wavelengths: 532 nm, 633 nm, 785 nm, and 1064 nm. The system will have software-controlled, motorized switching between the laser wavelengths. The lasers shall be coupled into the microscope using single mode, polarization...","url":"https://matchawards.com/dept_of_the_army/posts/107020497721473775","identifier":"W911SR-21-R-SCOP","category":"334516 - Analytical Laboratory Instrument Manufacturing","additionalProperty":[{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6640 - LABORATORY EQUIPMENT AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.4 Test \u0026 Measurement Supplies","url":"https://matchawards.com/categories/industrial-products-and-services/test-and-measurement-supplies"}],"availabilityStarts":"2021-09-30","availabilityEnds":"2021-09-30","sameAs":"https://sam.gov/opp/6c4523fb15f04e32a20b8061a7013a76/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```