<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/106743044525458272" -->

---
title: Uninterruptible Power Supply (UPS) Preventative Maintenance… | Closed - MatchAwards
description: Uninterruptible Power Supply (UPS) Preventative Maintenance Services. United States Department of the Army. Solicitation UPSMaintSSS. NAICS 541512 - Computer Systems Design Services. Deadline 2021-08-17. THIS IS A Sources Sought Notice ONLY. The U.S. Government desires to procure Uninterruptible...
canonical: https://matchawards.com/dept_of_the_army/posts/106743044525458272
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Uninterruptible Power Supply (UPS) Preventative Maintenance… | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/106743044525458272
og:description: Uninterruptible Power Supply (UPS) Preventative Maintenance Services. United States Department of the Army. Solicitation UPSMaintSSS. NAICS 541512 - Computer Systems Design Services. Deadline 2021-08-17. THIS IS A Sources Sought Notice ONLY. The U.S. Government desires to procure Uninterruptible...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Uninterruptible Power Supply (UPS) Preventative Maintenance Services

Status

Closed (archived notice)

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

JOINT BASE LEWIS MCCH, USA

Notice type

Sources Sought

Solicitation number

UPSMaintSSS

NAICS

[541512 - Computer Systems Design Services](/groups/908)

PSC

R425 - SUPPORT- PROFESSIONAL: ENGINEERING/TECHNICAL

Category

[Technical and Engineering Services (non-IT) (2.8)](/categories/professional-services/technical-and-engineering-services)

Posted

2021-08-12

Deadline

2021-08-17

Place of performance

Joint Base Lewis McChord, 98433

## Description

THIS IS A Sources Sought Notice ONLY. The U.S. Government desires to procure Uninterruptible Power Supply (UPS) Preventative Maintenance Services on a small business set-aside basis, provided 2 or more qualified small businesses respond to this sources sought synopsis with information sufficient to support a set-aside. Be advised that the U.S. Government will not be able to set aside this requirement if 2 or more small businesses do not respond with information to support the set-aside. We encourage all small businesses, in all socioeconomic categories (including, 8(a) Business Development Program, Small Disadvantage Business, Historically Underutilized Business Zone, Service-Disabled Veteran-Owned, Women-Owned Small Business concerns), to identify their capabilities in meeting the requirement at a fair market price. This notice is issued solely for information and planning purposes  it does not constitute a Request for Quote (RFQ)/Invitation for Bid (IFB)/Request for Proposal (RFP) or a promise to issue a RFQ, IFB or RFP in the future. This notice does not commit the U.S. Government to contract for any supply or service. Furthermore, the U.S. Government is not seeking quotes, bids or proposals at this time and will not accept unsolicited proposals in response to this sources sought notice. The U.S. Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ or IFB or RFP, if any is issued. If a solicitation is released, it will be synopsized on the Governmentwide Point of Entry (GPE). It is the responsibility of potential offerors to monitor the GPE for additional information pertaining to this requirement. The anticipated NAICS code is: 541512 Computer Systems Design Services, with a size standard of $30M. Place of Performance: Locations Joint Base Lewis-McChord, WA Yakima Training Center, Yakima, WA The contractor shall provide maintenance to include the following: Provide Preventative Maintenance twice a year for UPS maintenance at the two locations. Provide Preventative Maintenance twice a year for Battery maintenance at the two locations. Provide coverage 24 hours, 7 days a week corrective maintenance as required covering all parts, labor, travel time and expenses. Provide coverage 24 hours, 7 days a week dispatch technical support and service priority with 8-hours response time. Provide coverage 24 hours, 7 days a week customer reliability center triage. Performance during each preventative maintenance visit will be as follows: A. Measure and record: 1\. Individual cell battery float voltage and overall float voltage; 2\. Charger output current and voltage; 3\. AC ripple current and voltage imposed on battery; 4\. Internal ohmic values of each cell/battery or perform a continuity test of each cell/battery; 5\. Connection resistance of 10% of the inter cell/battery connection; 6\. Ambient temperature; and 7\. Negative terminal temperature of one cell/battery per battery cabinet or rack tier. B. Visually inspect conditions and appearance of the: 1\. Connection terminals inter cell/battery connectors, cables and associated hardware; 2\. Cell/battery covers, containers, and post seals; 3\. Battery racks or cabinets and associated components and hardware; 4\. Cell/battery jar or cover, nothing any excessive distortion; and 5\. Perform cleaning of all accessible surfaces as required. C. Measure and record the connection resistance of 100% of the inter cell/battery string. D. Re-torque any connection where the resistance is above 20% of the average. Reporting requirements for each preventative maintenance visit includes: The technician will provide the Government a verbal report summarizing the condition of the UPS and battery, and identifying any critical issues before leaving the performance site. A detailed written report containing all readings and observations will be sent to the Government within five (5) business days. The contractor shall be experienced and qualified to operate and repair the UPS systems and peripheral equipment at Table 1\. Table 1  List of UPS Equipment Equipment Type Model Number Serial Number Remarks Eaton Powerware UPS 9390 9390-100-160 EJ043CBC01 Includes Battery Cabinet and Controller Cabinet APC Symmetra PX PD40F6FK1-M 40kWA PD0818160213 Includes Power Management/ Power Distribution In response to this sources sought, please, complete the attached Sources Sought Synopsis Questionnaire. 

<!-- mobian-agent-ad sponsored="true" id="803adf47-43ba-434d-9ce7-494cb0dc8e95" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/professional-services/technical-and-engineering-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Beverly Cortez

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/88d848732bee4b479982247b25c926f7/view)

[More from United States Department of the Army posted in August 2021](/dept%5Fof%5Fthe%5Farmy/archive/2021-08)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Uninterruptible Power Supply (UPS) Preventative Maintenance Services","description":"THIS IS A Sources Sought Notice ONLY. The U.S. Government desires to procure Uninterruptible Power Supply (UPS) Preventative Maintenance Services on a small business set-aside basis, provided 2 or more qualified small businesses respond to this sources sought synopsis with information sufficient to support a set-aside. Be advised that the U.S. Government will not be able to set aside this requirement if 2 or more small businesses do not respond with information to support the set-aside. We encourage all small businesses, in all socioeconomic categories (including, 8(a) Business Development Program, Small Disadvantage Business, Historically Underutilized Business Zone, Service-Disabled Veteran-Owned, Women-Owned Small Business concerns), to identify their capabilities in meeting the requirement at a fair market price. This notice is issued solely for information and planning purposes  it does not constitute a Request for Quote (RFQ)/Invitation for Bid (IFB)/Request for Proposal (RFP) or a promise to issue a RFQ, IFB or RFP in the future. This notice does not commit the U.S. Government to contract for any supply or service. Furthermore, the U.S. Government is not seeking quotes, bids or proposals at this time and will not accept unsolicited proposals in response to this sources sought notice. The U.S. Government will not pay for any information or administrative costs incurred in response to this notice. Submittals will not be returned to the responder. Not responding to this notice does not preclude participation in any future RFQ or IFB or RFP, if any is issued. If a solicitation is released, it will be synopsized on the Governmentwide Point of Entry (GPE). It is the responsibility of potential offerors to monitor the GPE for additional information pertaining to this requirement. The anticipated NAICS code is: 541512 Computer Systems Design Services, with a size standard of $30M. Place of Performance: Locations Joint Base Lewis-McChord, WA Yakima Training Center, Yakima, WA The contractor shall provide maintenance to include the following: Provide Preventative Maintenance twice a year for UPS maintenance at the two locations. Provide Preventative Maintenance twice a year for Battery maintenance at the two locations. Provide coverage 24 hours, 7 days a week corrective maintenance as required covering all parts, labor, travel time and expenses. Provide coverage 24 hours, 7 days a week dispatch technical support and service priority with 8-hours response time. Provide coverage 24 hours, 7 days a week customer reliability center triage. Performance during each preventative maintenance visit will be as follows: A. Measure and record: 1. Individual cell battery float voltage and overall float voltage; 2. Charger output current and voltage; 3. AC ripple current and voltage imposed on battery; 4. Internal ohmic values of each cell/battery or perform a continuity test of each cell/battery; 5. Connection resistance of 10% of the inter cell/battery connection; 6. Ambient temperature; and 7. Negative terminal temperature of one cell/battery per battery cabinet or rack tier. B. Visually inspect conditions and appearance of the: 1. Connection terminals inter cell/battery connectors, cables and associated hardware; 2. Cell/battery covers, containers, and post seals; 3. Battery racks or cabinets and associated components and hardware; 4. Cell/battery jar or cover, nothing any excessive distortion; and 5. Perform cleaning of all accessible surfaces as required. C. Measure and record the connection resistance of 100% of the inter cell/battery string. D. Re-torque any connection where the resistance is above 20% of the average. Reporting requirements for each preventative maintenance visit includes: The technician will provide the Government a verbal report summarizing the condition of the UPS and battery, and identifying any critical issues before leaving the performance site. A detailed written report containing all readings and observations will be sent to the Government within five (5) business days. The contractor shall be experienced and qualified to operate and repair the UPS systems and peripheral equipment at Table 1. Table 1  List of UPS Equipment Equipment Type Model Number Serial Number Remarks Eaton Powerware UPS 9390 9390-100-160 EJ043CBC01 Includes Battery Cabinet and Controller Cabinet APC Symmetra PX PD40F6FK1-M 40kWA PD0818160213 Includes Power Management/ Power Distribution In response to this sources sought, please, complete the attached Sources Sought Synopsis Questionnaire.","url":"https://matchawards.com/dept_of_the_army/posts/106743044525458272","identifier":"UPSMaintSSS","category":"541512 - Computer Systems Design Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"R425 - SUPPORT- PROFESSIONAL: ENGINEERING/TECHNICAL"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"2.8 Technical and Engineering Services (non-IT)","url":"https://matchawards.com/categories/professional-services/technical-and-engineering-services"}],"availabilityStarts":"2021-08-12","availabilityEnds":"2021-08-17","areaServed":"Joint Base Lewis McChord, 98433","sameAs":"https://sam.gov/opp/88d848732bee4b479982247b25c926f7/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Professional services","item":"https://matchawards.com/contracts/professional-services"}]}
```