<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_army/posts/105638894012463841" -->

---
title: Lower Monumental DC and LV Switchgear Upgrades | Closed - MatchAwards
description: Lower Monumental DC and LV Switchgear Upgrades. United States Department of the Army. Solicitation W912EF21RSS16. NAICS 238210 - Electrical Contractors and Other Wiring Installation Contractors. Deadline 2021-02-17. The US Army Corps of Engineers (USACE), Walla Walla District is seeking sources...
canonical: https://matchawards.com/dept_of_the_army/posts/105638894012463841
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Lower Monumental DC and LV Switchgear Upgrades | Closed
og:url: https://matchawards.com/dept_of_the_army/posts/105638894012463841
og:description: Lower Monumental DC and LV Switchgear Upgrades. United States Department of the Army. Solicitation W912EF21RSS16. NAICS 238210 - Electrical Contractors and Other Wiring Installation Contractors. Deadline 2021-02-17. The US Army Corps of Engineers (USACE), Walla Walla District is seeking sources...
og:image: https://matchawards.com/system/accounts/avatars/000/000/092/original/04da5de8c6ff714b.png?1638996022
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Lower Monumental DC and LV Switchgear Upgrades

Status

Closed (archived notice)

Agency

[United States Department of the Army](/dept%5Fof%5Fthe%5Farmy)

Office

WALLA WALLA, USA

Notice type

Sources Sought

Solicitation number

W912EF21RSS16

NAICS

[238210 - Electrical Contractors and Other Wiring Installation Contractors](/groups/227)

PSC

Z2KA - REPAIR OR ALTERATION OF DAMS

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Posted

2021-01-29

Deadline

2021-02-17

Place of performance

Kahlotus, 99335

## Description

The US Army Corps of Engineers (USACE), Walla Walla District is seeking sources for a construction project entitled: Lower Monumental DC and LV Switchgear Upgrades. The work is located at the U.S. Army Corps of Engineers Lower Monumental Lock and Dam near Kahlotus, Washington. The resulting contract will be a firm fixed-price construction contract. The North American Industry Classification System (NAICS) code for this project is 238210 Electrical Contractors and Other Wiring Installation Contractors. The associated small business size standard is $16.5 million. The magnitude of construction for this project is expected to be between $10,000,000 and $25,000,000\. This sources-sought announcement is a tool to identify businesses with the capability to accomplish the work. This is not a solicitation. Only those firms that respond to this announcement by submitting the following information will be used in determining whether to set aside this requirement. 1\. A list of no more than five current projects at least 50% physically complete or past projects demonstrating technical experience with work of a similar nature to that listed in the Summary Scope of Work. For each project submitted, provide a brief narrative statement of the work involved, your firms role in the project, the dollar value and the completion date. 2\. A reference list for each of the projects submitted in 1\. above. Include the name, title, phone number and email address for each reference. 3\. Provide a statement of your firms business size (HUBZone, Service Disabled Veteran Owned, 8(a), small disadvantaged, or woman-owned) with regards to the NAICS code listed above. 4\. Provide a statement that your firm intends to submit an offer on the project when it is advertised. 5\. Provide a statement of your firms bonding capacity. A statement from your surety is NOT required. 6\. Cage Code and DUNS number. Submit this information to David Boone, Contract Specialist, via email to david.c.boone@usace.army.mil. Your response to this notice must be received on or before 4:00 pm Pacific Time on Wednesday, February 17, 2021\. Summary of Scope of Work: This project will upgrade the Direct Current Systems and Low Voltage Switchgear at Lower Monumental. The upgrade will improve reliability and align the projects with the Regional Station Service Design Philosophy. Upgrades to the DC Systems include replacement of the DC system panels, preferred AC panels, chargers, battery boards and installation of load bank for performing discharge tests on the batteries in accordance with IEEE and the NERC/WECC requirements. This project will also replace the 480-Volt Low Voltage Station Service Switchgear including breakers and transformers for SQ0, SQ1; transformers for SQ2; 480-Volt Motor Control Centers and Panelboards FCQ1, CQ1 and CQ1.1, CQ01 through CQ05, and SH and SU Switchgear. 480V Switchgears & panelboards a) Replacement of two (2) 480V switchgear, two (2) 480V transformers; ten (10) motor control centers, and four (4) panelboards. b) All cables associated with the switchgear, MCC and panelboards will be replaced. c) All new switchgears, MCCs and panelboards to be provided must be from the same manufacturer. d) Conversion of twelve (12) 4160V governor oil pumps to 480V pumps. e) Installation of local control cabinets for each SQ (including SQ2) which will provide local hardwired controls and indication for 480V breakers. Cabinets will also house PLC I/O modules which will be integrated into the existing plant All-In-One (a.k.a. stand-alone) system. PLC inputs will include, but not be limited to, breaker status and racked out contacts, protective device contacts, and other relevant annunciation points. PLC outputs will provide remote SQ breaker trip/close controls from All-In-One HMI screens in the control room. Existing, generic hardwired SQ alarms will be replaced in kind to the alarm control panel (code call) in the control room. PLC inputs will also be provided for the new DC and preferred AC system. These input modules will be incorporated into the All-In-One system. Generic hardwired alarms for new DC and preferred AC system will be added to alarm control panel. DC & Preferred AC System a) All DC and Preferred AC system switchboards and panelboards will be replaced. b) All cables associated with the switchboards and panelboards will be replaced. c) All battery chargers, and battery monitoring system will be replaced. d) Installation of a permanent load bank for battery testing. e) Provide local annunciation at the SB boards for alarms. Annunciation points will connect to the control room all-in one system. f) Relocate the battery room lights to the aisle way instead of directly above the battery. g) Replacement of the door to battery room. New door will have 1-hour fire rating, be open from the inside and be equipped with listed panic hardware. h) Install new smoke sensors and hydrogen detector in the battery room. Mechanical a) Ventilation inlet will be dropped to a level below the top of the battery cells. b) Eye wash/Shower system will have an on demand, electric heater added (Tepid Water System). A reservoir will have to be added to the drain lines or shower unit will have to have its own reservoir attached. TECHNICAL EXPERIENCE REQUIREMENTS a) Installation of low voltage switchgear components, and motor control centers b) Installation of 125VDC equipment including chargers, switchboards and panelboards c) Post-installation testing and commissioning of equipment All on-site work shall be performed in accordance with the Corps of Engineers Safety and Health Requirements Manual (EM 385-1-1). The Contractor will be responsible for establishing and managing an effective on-site Safety and Health program in accordance with EM 385-1-1 that will require the development and submission of a comprehensive project specific Accident Prevention Plan for Government acceptance. In addition, the Contractor will be required to develop and submit for Government acceptance Activity Hazard Analyses for each phase of work and a project specific Fall Protection Plan that comply with EM 385-1-1\. A Site Safety and Health Officer (SSHO) employed by the prime contractor shall be required for each shift of the contractors on-site operations. The SSHO shall possess a minimum of 5-years of experience in construction safety on similar projects, shall have completed the 30-Hour OSHA Construction Safety training within the last 5-years, and shall have completed at least 24-hours of formal safety training each year for the past 5-years. The contractor will be required to perform the on-site work in compliance with Government Safe Clearance/Hazardous Energy Control Procedures. Prior to commencing on-site work, the contractor will be required to complete applicable safe clearance training for all personnel working in areas involved with Hazardous Energy Control. The project will involve the development and management of Contractor furnished submittals for items such as pre-construction plans, product data, test reports, and contract close-out documentation as required by the technical specifications of the contract. 

<!-- mobian-agent-ad sponsored="true" id="9e7ae015-4182-47b5-8cb0-7ed6e6e819aa" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* David Boone

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/6d9b2920a914433d9a03f3ecced48278/view)

[More from United States Department of the Army posted in January 2021](/dept%5Fof%5Fthe%5Farmy/archive/2021-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Lower Monumental DC and LV Switchgear Upgrades","description":"The US Army Corps of Engineers (USACE), Walla Walla District is seeking sources for a construction project entitled: Lower Monumental DC and LV Switchgear Upgrades. The work is located at the U.S. Army Corps of Engineers Lower Monumental Lock and Dam near Kahlotus, Washington. The resulting contract will be a firm fixed-price construction contract. The North American Industry Classification System (NAICS) code for this project is 238210 Electrical Contractors and Other Wiring Installation Contractors. The associated small business size standard is $16.5 million. The magnitude of construction for this project is expected to be between $10,000,000 and $25,000,000. This sources-sought announcement is a tool to identify businesses with the capability to accomplish the work. This is not a solicitation. Only those firms that respond to this announcement by submitting the following information will be used in determining whether to set aside this requirement. 1. A list of no more than five current projects at least 50% physically complete or past projects demonstrating technical experience with work of a similar nature to that listed in the Summary Scope of Work. For each project submitted, provide a brief narrative statement of the work involved, your firms role in the project, the dollar value and the completion date. 2. A reference list for each of the projects submitted in 1. above. Include the name, title, phone number and email address for each reference. 3. Provide a statement of your firms business size (HUBZone, Service Disabled Veteran Owned, 8(a), small disadvantaged, or woman-owned) with regards to the NAICS code listed above. 4. Provide a statement that your firm intends to submit an offer on the project when it is advertised. 5. Provide a statement of your firms bonding capacity. A statement from your surety is NOT required. 6. Cage Code and DUNS number. Submit this information to David Boone, Contract Specialist, via email to david.c.boone@usace.army.mil. Your response to this notice must be received on or before 4:00 pm Pacific Time on Wednesday, February 17, 2021. Summary of Scope of Work: This project will upgrade the Direct Current Systems and Low Voltage Switchgear at Lower Monumental. The upgrade will improve reliability and align the projects with the Regional Station Service Design Philosophy. Upgrades to the DC Systems include replacement of the DC system panels, preferred AC panels, chargers, battery boards and installation of load bank for performing discharge tests on the batteries in accordance with IEEE and the NERC/WECC requirements. This project will also replace the 480-Volt Low Voltage Station Service Switchgear including breakers and transformers for SQ0, SQ1; transformers for SQ2; 480-Volt Motor Control Centers and Panelboards FCQ1, CQ1 and CQ1.1, CQ01 through CQ05, and SH and SU Switchgear. 480V Switchgears \u0026 panelboards a) Replacement of two (2) 480V switchgear, two (2) 480V transformers; ten (10) motor control centers, and four (4) panelboards. b) All cables associated with the switchgear, MCC and panelboards will be replaced. c) All new switchgears, MCCs and panelboards to be provided must be from the same manufacturer. d) Conversion of twelve (12) 4160V governor oil pumps to 480V pumps. e) Installation of local control cabinets for each SQ (including SQ2) which will provide local hardwired controls and indication for 480V breakers. Cabinets will also house PLC I/O modules which will be integrated into the existing plant All-In-One (a.k.a. stand-alone) system. PLC inputs will include, but not be limited to, breaker status and racked out contacts, protective device contacts, and other relevant annunciation points. PLC outputs will provide remote SQ breaker trip/close controls from All-In-One HMI screens in the control room. Existing, generic hardwired SQ alarms will be replaced in kind to the alarm control panel (code call) in the control room. PLC inputs will also be provided for the new DC and preferred AC system. These input modules will be incorporated into the All-In-One system. Generic hardwired alarms for new DC and preferred AC system will be added to alarm control panel. DC \u0026 Preferred AC System a) All DC and Preferred AC system switchboards and panelboards will be replaced. b) All cables associated with the switchboards and panelboards will be replaced. c) All battery chargers, and battery monitoring system will be replaced. d) Installation of a permanent load bank for battery testing. e) Provide local annunciation at the SB boards for alarms. Annunciation points will connect to the control room all-in one system. f) Relocate the battery room lights to the aisle way instead of directly above the battery. g) Replacement of the door to battery room. New door will have 1-hour fire rating, be open from the inside and be equipped with listed panic hardware. h) Install new smoke sensors and hydrogen detector in the battery room. Mechanical a) Ventilation inlet will...","url":"https://matchawards.com/dept_of_the_army/posts/105638894012463841","identifier":"W912EF21RSS16","category":"238210 - Electrical Contractors and Other Wiring Installation Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"Z2KA - REPAIR OR ALTERATION OF DAMS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2021-01-29","availabilityEnds":"2021-02-17","areaServed":"Kahlotus, 99335","sameAs":"https://sam.gov/opp/6d9b2920a914433d9a03f3ecced48278/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Construction","item":"https://matchawards.com/contracts/construction"}]}
```