Fire Trainer Liner

Status
Closed, the response deadline passed on Jul 30, 2026
Agency
United States Department of the Air Force
Office
SEYMOUR JOHNSON AFB, USA
Notice type
Presolicitation
Solicitation number
FA480926Q0065
NAICS
238990 - All Other Specialty Trade Contractors
PSC
4240 - SAFETY AND RESCUE EQUIPMENT
Category
Fire/Rescue/Safety/Environmental Protection Equipment (5.2)
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
2026-07-21
Deadline
2026-07-30
Place of performance
Goldsboro, North Carolina 27531, UNITED STATES

Description

SALIENT CHARACTERISTICS
for
Structural Trainer Liner
DESCRIPTION: Replace liner inside the structural trainer
REQUIREMENTS: The liner components units shall:
1. Designed to meet all referenced safety, thermal, and regulatory specifications, this specific material is engineered for extreme live-fire training evolutions.
2. Specifically formulated for Class A, B, C, D, Electrical, and F/K fires within a controlled burn cell which complies with NFPA 1402 and related standards.
3. Made of a cementitious high temp composite formula, which has a negative health impact when installed by certified installers.
4. Have Kevlar additives
5. Unique tongue and groove installation method
6. Stainless Steel mounting hardware
7. Have five (5) to ten (10) year warranty to replace
8. Able to withstand 150 psi nozzle forces
9. 1.5 inches thick requires no additional insulation behind its barrier
10. Heat transfer 10.4% (1000 degree / 140 degree in 10 minutes)
11. Complies with all NFPA suggested burn matrix formulas
12. Certified as a protective skin for flammable hazmat storage cells