<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_air_force/posts/116795496975911400" -->

---
title: Oil/ Coolant Storage & Dispenser System | Closed - MatchAwards
description: Oil/ Coolant Storage & Dispenser System. United States Department of the Air Force. Solicitation FA452826QSP02. NAICS 332420 - Metal Tank (Heavy Gauge) Manufacturing. Total small business set-aside. Deadline 2026-07-16. Name: Oil/Coolant Storage and Dispenser Make: NOT A BRAND NAME SET-ASIDE...
canonical: https://matchawards.com/dept_of_the_air_force/posts/116795496975911400
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Oil/ Coolant Storage & Dispenser System | Closed
og:url: https://matchawards.com/dept_of_the_air_force/posts/116795496975911400
og:description: Oil/ Coolant Storage & Dispenser System. United States Department of the Air Force. Solicitation FA452826QSP02. NAICS 332420 - Metal Tank (Heavy Gauge) Manufacturing. Total small business set-aside. Deadline 2026-07-16. Name: Oil/Coolant Storage and Dispenser Make: NOT A BRAND NAME SET-ASIDE...
og:image: https://matchawards.com/system/accounts/avatars/000/000/081/original/b1dfb2d25d539fd5.png?1638989862
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Oil/ Coolant Storage & Dispenser System

Status

Closed, the response deadline passed on Jul 16, 2026

Agency

[United States Department of the Air Force](/dept%5Fof%5Fthe%5Fair%5Fforce)

Office

MINOT AFB, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

FA452826QSP02

NAICS

[332420 - Metal Tank (Heavy Gauge) Manufacturing](/groups/440)

PSC

5430 - STORAGE TANKS

Category

[Construction Related Materials (4.1)](/categories/facilities-and-construction/construction-related-materials)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2026-07-08

Deadline

2026-07-16

Place of performance

Minot AFB, North Dakota 58704, UNITED STATES

## Description

Name: Oil/Coolant Storage and Dispenser

Make: **NOT A BRAND NAME SET-ASIDE** Lubrisource or **equal**

Model: HDL4-FS-0064-3W-2E-1F-1SP or equal

The suggested brand name is Lubrisource; however, quotes for "**equal**" products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics

<!-- mobian-agent-ad sponsored="true" id="f721b096-f1f2-4350-8d07-2cf5c23706b2" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/construction-related-materials?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


**System Configuration & Facility Requirements**

Must fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space).

Stackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4.

Must operate on standard 115V power utilizing Type B plugs.

Equipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup.

Eight (8) 65-Gallon aluminized steel, rectangular containers. Tanks must feature sloped bottoms and drain ports for easy cleaning.

Fluid Capacities & Coding

System must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids.

Top-mounted ports must utilize 1 ½” Quick-Disconnect (QD) fittings connected to 2” NPT ports.

Top-mounted desiccant breathers featuring visual "Color-Change" indicators.

Sight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations.

Two (2) 115V, minimum 8 GPM, self-priming gear pumps (or stronger) with suction tube assemblies. (One dedicated to Oil, one for Coolant).

Two (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill.

Must include lockable dispensing ball valves.

It must feature 10-micron inline filters prior to dispensing.

Must include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes.

Spill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement).

Drip pans must be included. (Drain valves on drip pans are not required).

All sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.

## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2139616af7b0472eaeb4dce234fea61e/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2d5a10094c2f421aabde07dd967bfe75/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6d3ef36ec314401f9724415597080027/download)
* [Attachment 4](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/90672601a95e4372b3da6864f8b2e81a/download)
* [Attachment 5](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ce2bfc96ab434eb2a1d5470553d916db/download)
* [Attachment 6](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cf57ff15c56e4387aee03ecbe8fd946c/download)
* [Attachment 7](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fab34482c23e47549cd5319e26544fa8/download)

## Contacts

* Sherry L. Platt
* Ted Arneson

Email and phone are in the source notice.

[Source notice](https://sam.gov/workspace/contract/opp/cd0bb264c4d14fb6ad5a7e02e79ba7e5/view)

[More from United States Department of the Air Force posted in June 2026](/dept%5Fof%5Fthe%5Fair%5Fforce/archive/2026-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Oil/ Coolant Storage \u0026 Dispenser System","description":"Name: Oil/Coolant Storage and Dispenser Make: NOT A BRAND NAME SET-ASIDE Lubrisource or equal Model: HDL4-FS-0064-3W-2E-1F-1SP or equal The suggested brand name is Lubrisource; however, quotes for \" equal \" products will be evaluated and accepted provided they meet all the essential physical, functional, and performance characteristics System Configuration \u0026 Facility Requirements Must fit within a maximum space of 12ft W x 9ft D x 10ft H. (Dimensions may be adjusted if the design safely maximizes vertical space). Stackable, modular, or racked design. Must include brackets to hold the containers securely in 2 rows of 4. Must operate on standard 115V power utilizing Type B plugs. Equipment delivery only. Contractors are NOT required to perform physical assembly, anchoring, or setup. Eight (8) 65-Gallon aluminized steel, rectangular containers. Tanks must feature sloped bottoms and drain ports for easy cleaning. Fluid Capacities \u0026 Coding System must be capable of holding a minimum of 275 Gallons of Oil (up to 15W-40 viscosity) and 165 Gallons of Coolant. Tanks must be color-coded to clearly identify different fluids. Top-mounted ports must utilize 1 ½” Quick-Disconnect (QD) fittings connected to 2” NPT ports. Top-mounted desiccant breathers featuring visual \"Color-Change\" indicators. Sight gauges for visual monitoring of liquid levels. Gauges must include printed volume demarcations. Two (2) 115V, minimum 8 GPM, self-priming gear pumps (or stronger) with suction tube assemblies. (One dedicated to Oil, one for Coolant). Two (2) 50ft Hose Reels (one for Oil, one for Coolant). Pumps must be strong enough to support the 50ft reels and intake/refill. Must include lockable dispensing ball valves. It must feature 10-micron inline filters prior to dispensing. Must include isolation valves installed before the filters for both coolant and oil to allow fluid shutoff during filter changes. Spill containment must hold a minimum of 130 Gallons (which satisfies the 25% of total liquid stored requirement). Drip pans must be included. (Drain valves on drip pans are not required). All sight gauges must have isolation valves installed to prevent leaks if the gauge glass is broken.","url":"https://matchawards.com/dept_of_the_air_force/posts/116795496975911400","identifier":"FA452826QSP02","category":"332420 - Metal Tank (Heavy Gauge) Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"5430 - STORAGE TANKS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.1 Construction Related Materials","url":"https://matchawards.com/categories/facilities-and-construction/construction-related-materials"}],"availabilityStarts":"2026-07-08","availabilityEnds":"2026-07-16","validThrough":"2026-07-16T23:59:59-04:00","areaServed":"Minot AFB, North Dakota 58704, UNITED STATES","sameAs":"https://sam.gov/workspace/contract/opp/cd0bb264c4d14fb6ad5a7e02e79ba7e5/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```

