ClickCease GXT Stress Test Machine (FA700025Q0GXT) | Closed - MatchAwards

GXT Stress Test Machine

Status
Closed, the response deadline passed on Sep 12, 2025
Agency
United States Department of the Air Force
Office
USAF ACADEMY, USA
Notice type
Sources Sought
Solicitation number
FA700025Q0GXT
NAICS
334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
PSC
6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
Category
Medical Equipment and Accessories and Supplies (10.2)
Posted
2025-09-10
Deadline
2025-09-12
Place of performance
USAF Academy, Colorado 80840, UNITED STATES

Description

Qty 1- GXT Stress Test Machine

- Must have SCIMAGE/PICOM connection capabilities.
- At least a Windows 10 Operating System or newer.
- Set-up, delivery, installation, and user interface training for technician.
- ELI LINK connectivity for SCIMAGE/PICOM connection integration.
- BP monitoring capabilities with SunTech Tango and SpO2
- Full features include:
• Automatic ST segment analysis and trending on all 12 leads.
• Superimposition comparison of current and reference complexes on both a 4x QRS, and updated 12-lead
median complexes.
• Context View during the exam allowing full disclosure review and addition of past ECG events.
• Automatic ventricular ectopic beat detection.
• Up to 100 different exercise protocols.
• Automatic 12-lead ECGs with prompts for manual or automated (optional) blood pressure acquisition.
• Multiple final report formats with custom report sequence capabilities and automated narrative summary.
• Networked export of XML, PDF, HL7, or DICOM® results.
• Networked receipt of XML, HL7, or DICOM orders.
• Archive directories with full disclosure exam data.
• User-defined ST measurement points.
• Analog and TTL output for interface with external devices.
• Programmable and fixed protocols, procedures, and final reports.
• Pre-test electrode impedance check.
• Demonstration mode.
• Automated NIBP and SpO2 readings (with optional device).
• Various text and graphical formats.
• Medications, notes, diagnoses, indications, and procedural comment entries.
• Rate of Perceived Exertion (RPE) entry during test.
• Source Consistency Filter (SCF).
• Beat Consistency Filter (BCF) on ECG printouts.
• METs, maximum predicted heart rate, and target heart rate formula selection.
• Various exercise controls with compatible treadmills, ergometers, and pharmacological studies.
• Ability to select final report segments including Patient Information, Exam Summary, Rate/BP/Workload
Trends, ST Level Trends, ST Slope Trends, Worst Case Average, Periodic Averages, Peak Averages, and
ECG Prints.
• ST level and slope data for lead and worst-case average beat, updated continually during test.
INTRODUCTION27
• Editing of final report in Review phase.
• Paperless workflow capability.
• Ability to store exams and final reports in a centralized database.
• Pre-registration and scheduling of patients.
• Health risk assessment based on Duke and Functional Aerobic Impairment (FAI) algorithms.
 

Source notice