Description
Qty 1- GXT Stress Test Machine
- Must have SCIMAGE/PICOM connection capabilities.
- At least a Windows 10 Operating System or newer.
- Set-up, delivery, installation, and user interface training for technician.
- ELI LINK connectivity for SCIMAGE/PICOM connection integration.
- BP monitoring capabilities with SunTech Tango and SpO2
- Full features include:
• Automatic ST segment analysis and trending on all 12 leads.
• Superimposition comparison of current and reference complexes on both a 4x QRS, and updated 12-lead
median complexes.
• Context View during the exam allowing full disclosure review and addition of past ECG events.
• Automatic ventricular ectopic beat detection.
• Up to 100 different exercise protocols.
• Automatic 12-lead ECGs with prompts for manual or automated (optional) blood pressure acquisition.
• Multiple final report formats with custom report sequence capabilities and automated narrative summary.
• Networked export of XML, PDF, HL7, or DICOM® results.
• Networked receipt of XML, HL7, or DICOM orders.
• Archive directories with full disclosure exam data.
• User-defined ST measurement points.
• Analog and TTL output for interface with external devices.
• Programmable and fixed protocols, procedures, and final reports.
• Pre-test electrode impedance check.
• Demonstration mode.
• Automated NIBP and SpO2 readings (with optional device).
• Various text and graphical formats.
• Medications, notes, diagnoses, indications, and procedural comment entries.
• Rate of Perceived Exertion (RPE) entry during test.
• Source Consistency Filter (SCF).
• Beat Consistency Filter (BCF) on ECG printouts.
• METs, maximum predicted heart rate, and target heart rate formula selection.
• Various exercise controls with compatible treadmills, ergometers, and pharmacological studies.
• Ability to select final report segments including Patient Information, Exam Summary, Rate/BP/Workload
Trends, ST Level Trends, ST Slope Trends, Worst Case Average, Periodic Averages, Peak Averages, and
ECG Prints.
• ST level and slope data for lead and worst-case average beat, updated continually during test.
INTRODUCTION27
• Editing of final report in Review phase.
• Paperless workflow capability.
• Ability to store exams and final reports in a centralized database.
• Pre-registration and scheduling of patients.
• Health risk assessment based on Duke and Functional Aerobic Impairment (FAI) algorithms.