ClickCease CONSTRUCT ADDITION & REPAIR INTERIOR, BLDG 47, 328 WPS, NELLIS… | Closed - MatchAwards

CONSTRUCT ADDITION & REPAIR INTERIOR, BLDG 47, 328 WPS, NELLIS AFB NV

Status
Closed, the response deadline passed on Aug 28, 2025
Agency
United States Department of the Air Force
Office
NELLIS AFB, USA
Notice type
Sources Sought
Solicitation number
FA486125B0001
NAICS
236220 - Commercial and Institutional Building Construction
PSC
Z2AA - REPAIR OR ALTERATION OF OFFICE BUILDINGS
Category
Facility Related Services (4.4)
Set-aside
8(a) Set-Aside (FAR 19.8)
Posted
2025-08-15
Deadline
2025-08-28
Place of performance
Nellis AFB, Nevada 89191, UNITED STATES

Description

CONSTRUCT ADDTION AND REPAIR INTERIOR, B47, 328 WPS, NELLIS AFB NV

(RKMF230064)

MAGNITUDE:  More than $10M

BONDING CAPABILITY: $15M

FAVORABLE CPARS / PAST PERFORMANCE

SOURCES SOUGHT FOR

8(a) CONTRACTORS IN SBA REGION 9 (CA, NV, HI, AZ)

SYNOPSIS

Design-Build; 8(a) contractor shall take current 35% design package to the 100% design level, then build.

Work consists of furnishing all labor, supplies, materials, supervision, transportation, and equipment required for repair and minor construction of Building 47. Building 47 is a single story facility, constructed of masonry units, built-up roofing on metal decking over steel joists, approximately 6,814 SF. Work required includes renovation of the existing structure to construct three (3) large offices, one (1) small and three (3) small multipurpose rooms, two (2) server rooms, a conference room, a mother’s room, restrooms, a utility room and breakroom. Work will also include two additions of over 5,000 SF. The west addition shall include the new building entry, a lobby, two (2) small offices, a large auditorium, a large multipurpose room, and a large office, covered by an extension of the existing roof. An addition on the south side shall have five (5) offices. The parking lot and landscaping shall be repaired as designed. Any suspect asbestos containing materials that are encountered during demolition or observed to be present during renovation activities, shall be sampled and analyzed for asbestos and shall treated, handled, and disposed of accordingly. Lead abatement will be required. The office rooms, large auditorium, multipurpose rooms and briefing rooms, inside renovated area, and new addition (except lobby and two (2) offices inside the lobby), are to be constructed to meet the requirements of ICD-705 Physical Security requirements. New power, communication, plumbing, drains, Heating Ventilation and Air Conditioning, Fire Alarm & Mass Notification System and fire suppression are required for the project. All conduits, J- boxes, electrical power, grounding, and communication circuits to support a new Access Control System (ACS), and Intrusion Detection System (IDS).

Attachments

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of the Air Force posted in April 2025

More lists