CONSTRUCT ADDITION & REPAIR INTERIOR, BLDG 47, 328 WPS, NELLIS AFB NV
- Status
- Closed, the response deadline passed on Aug 28, 2025
- Agency
- United States Department of the Air Force
- Office
- NELLIS AFB, USA
- Notice type
- Sources Sought
- Solicitation number
- FA486125B0001
- NAICS
- 236220 - Commercial and Institutional Building Construction
- PSC
- Z2AA - REPAIR OR ALTERATION OF OFFICE BUILDINGS
- Category
- Facility Related Services (4.4)
- Set-aside
- 8(a) Set-Aside (FAR 19.8)
- Posted
- 2025-08-15
- Deadline
- 2025-08-28
- Place of performance
- Nellis AFB, Nevada 89191, UNITED STATES
Description
CONSTRUCT ADDTION AND REPAIR INTERIOR, B47, 328 WPS, NELLIS AFB NV
(RKMF230064)
MAGNITUDE: More than $10M
BONDING CAPABILITY: $15M
FAVORABLE CPARS / PAST PERFORMANCE
SOURCES SOUGHT FOR
8(a) CONTRACTORS IN SBA REGION 9 (CA, NV, HI, AZ)
SYNOPSIS
Design-Build; 8(a) contractor shall take current 35% design package to the 100% design level, then build.
Work consists of furnishing all labor, supplies, materials, supervision, transportation, and equipment required for repair and minor construction of Building 47. Building 47 is a single story facility, constructed of masonry units, built-up roofing on metal decking over steel joists, approximately 6,814 SF. Work required includes renovation of the existing structure to construct three (3) large offices, one (1) small and three (3) small multipurpose rooms, two (2) server rooms, a conference room, a mother’s room, restrooms, a utility room and breakroom. Work will also include two additions of over 5,000 SF. The west addition shall include the new building entry, a lobby, two (2) small offices, a large auditorium, a large multipurpose room, and a large office, covered by an extension of the existing roof. An addition on the south side shall have five (5) offices. The parking lot and landscaping shall be repaired as designed. Any suspect asbestos containing materials that are encountered during demolition or observed to be present during renovation activities, shall be sampled and analyzed for asbestos and shall treated, handled, and disposed of accordingly. Lead abatement will be required. The office rooms, large auditorium, multipurpose rooms and briefing rooms, inside renovated area, and new addition (except lobby and two (2) offices inside the lobby), are to be constructed to meet the requirements of ICD-705 Physical Security requirements. New power, communication, plumbing, drains, Heating Ventilation and Air Conditioning, Fire Alarm & Mass Notification System and fire suppression are required for the project. All conduits, J- boxes, electrical power, grounding, and communication circuits to support a new Access Control System (ACS), and Intrusion Detection System (IDS).
Attachments
- Attachment 1
- Attachment 2
- Attachment 3
- Attachment 4
- Attachment 5
- Attachment 6
- Attachment 7
- Attachment 8
- Attachment 9
- Attachment 10
- Attachment 11
- Attachment 12
- Attachment 13
- Attachment 14
- Attachment 15
- Attachment 16
- Attachment 17
- Attachment 18
- Attachment 19
- Attachment 20
- Attachment 21
- Attachment 22
- Attachment 23
- Attachment 24
Contacts
- Nina M. Young
Email and phone are in the source notice.
More from United States Department of the Air Force posted in April 2025