ClickCease A24-007 Water Cooled Xray System | Closed - MatchAwards

A24-007 Water Cooled Xray System

Status
Closed, the response deadline passed on Jan 9, 2025
Agency
United States Department of the Air Force
Office
TINKER AFB, USA
Notice type
Sources Sought
Solicitation number
FA812525Q0027
NAICS
334519 - Other Measuring and Controlling Device Manufacturing
PSC
6680 - LIQUID AND GAS FLOW, LIQUID LEVEL, AND MECHANICAL MOTION MEASURING INSTRUMENTS
Category
Test & Measurement Supplies (5.4)
Set-aside
Total Small Business Set-Aside (FAR 19.5)
Posted
2025-01-08
Deadline
2025-01-09
Place of performance
Carlton Lndg, Oklahoma 73145, UNITED STATES

Description

A24-007 Water Cooled Xray System 76 AMXG Request for the purchase of 4 ea.

Water Cooled Xray System to include the following:

Input Line Requirements:

Automatically adapts to input line voltage100-130Vac, 50/60Hz, 20 Amperes maximum.

200-250Vac, 50/60Hz, 10 Amperes maximum.

10 to 160kV, 0.5mA to 5.0mA (800 watts max.)

Constant potential, end-grounded anode, liquid cooled version.

X-Ray Tube Window: Beryllium 0.8mm (directional) 40° directional.

Radiation Output: 14R/min at 50cm filtered with 0.5 inches (12.7mm).

aluminum at 160kV, 5mA.

Radiation Leakage: Less than 2.0 Roentgens per hour at 1 meter from the X-Ray tube target.

Effective Focal Spot: Standard: 0.7mm x 1.0mm (0.03in x 0.04in) EN125430.5mm x 0.5mm (0.02in x 0.02in) nominal IEC60336.

Ambient Temp: 100% duty cycle @ 120°F (49°C).

Duty Cycle: 100%.

Storage Temp: -30°F to 160°F (-35°C to 71°C).

Anode Cooling: Liquid coolant solution closed loop between X-Ray tube anode and cooling unit.

Liquid Cooling Unit Weight: 54lbs. (15.4kg) approx.

Tube Head Dimensions: No greater than 7.25" Diameter, 30" Length.

Liquid Cooled: 29lbs. (13.15kg) X-Ray Control Unit: X-Ray Control Unit Weight: 26lbs. (11.8kg) approx.

Safety Devices:

Tubehead Pressure Relief Valve

Tubehead Thermal Cut-Out

Tubehead Pressure Gauge

Tubehead Low Pressure Cut-Out @ 25psi (1.72 Bar)

Coolant Flow Sensor (liquid cooled only)

Control Unit Safety Keyswitch

Microcomputer-based Self Diagnostics

Continuous Exposure Parameter Display

Standard Accessories:

Operation manual

Tubehead carrying case

Tubehead Cable- 100’ with strain relief

Extra key (1) for Control Unit Safety Lock

Power cable - 25’ with strain relief

Coolant hose - twin, 50’ with self-sealing terminations

(liquid cooled only)

Cooler power cable

GUI Control Software for the GUI is specifically designed for controlling series systems. As an alternative to the front panel control, the GUI will allow the user to control all necessary functions of the system from a user-friendly windows-based menu. Additionally, the GUI can be used as a diagnostic tool when the system is controlled via the front panel.