<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/dept_of_the_air_force/posts/108424750712645083" -->

---
title: Upgrade the Emergency Power System at Building 104 | Closed - MatchAwards
description: Upgrade the Emergency Power System at Building 104. United States Department of the Air Force. Solicitation FA2823-22-R-0014. NAICS 236220 - Commercial and Institutional Building Construction. Total small business set-aside. Deadline 2022-06-20. SYNOPSIS AT FA2823-22-R-0014 Eglin Air Force Base...
canonical: https://matchawards.com/dept_of_the_air_force/posts/108424750712645083
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Upgrade the Emergency Power System at Building 104 | Closed
og:url: https://matchawards.com/dept_of_the_air_force/posts/108424750712645083
og:description: Upgrade the Emergency Power System at Building 104. United States Department of the Air Force. Solicitation FA2823-22-R-0014. NAICS 236220 - Commercial and Institutional Building Construction. Total small business set-aside. Deadline 2022-06-20. SYNOPSIS AT FA2823-22-R-0014 Eglin Air Force Base...
og:image: https://matchawards.com/system/accounts/avatars/000/000/081/original/b1dfb2d25d539fd5.png?1638989862
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Upgrade the Emergency Power System at Building 104

Status

Closed (archived notice)

Agency

[United States Department of the Air Force](/dept%5Fof%5Fthe%5Fair%5Fforce)

Office

EGLIN AFB, USA

Notice type

Presolicitation

Solicitation number

FA2823-22-R-0014

NAICS

[236220 - Commercial and Institutional Building Construction](/groups/212)

PSC

Z2JZ - REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2022-06-05

Deadline

2022-06-20

Place of performance

FL-05, 32542

## Description

SYNOPSIS AT FA2823-22-R-0014 Eglin Air Force Base (AFB), FL has a requirement to provide all design and construction effort required to upgrade the Building 104, Eglin Radar Control Facility Emergency Power System on Eglin AFB, FL. The North American Industry Classification System (NAICS) code for this requirement is 236220 Commercial and Institutional Building Construction Contractors with a size standard of $39.5M. Statement of Magnitude is between $1,000,000 and $5,000,000\. This is a Small Business Set-Aside competitive acquisition utilizing a best value source selection process and award will be made based upon the Best Value to the Government in accordance with FAR Part 15.3\. This project includes, but is not limited to, the following: provide a new Emergency Power System that shall consolidate all mission critical electrical loads on one emergency generator and one automatic transfer switch (ATS). Replace 277/480 V, 800 A main distribution electrical panel MDP with new panel. Remove panel PC and transfer its circuits to new panel MDP. Remove 150 KVA and 225 KVA transformer banks, and replace with a new 480 V primary, 120/208 V secondary dry-type transformer (sized as required) fed from new panel MDP. Remove the 400 A safety switch feeding ATS #1, remove the 400 A technical ATS #1, and the 600 A mechanical ATS #2\. Then, install a new 120/208 V, 4-pole, Bypass Isolation, and Closed Transition ATS (sized as required) fed from the new dry-type transformer referenced above. Install a new 120/208 V circuit breaker sized as required to feed the new ATS referenced above. Remove the existing 175 KW and 100 KW emergency generators and install a new 120/208 V emergency generator (sized as required) in the existing generator roomif possible. Remove the existing underground diesel fuel storage tank and fuel piping. Install a new 1,000 gallon above ground storage tank and fuel piping connected to new generator. Remove the two 25-gallon generator day tanks in the existing generator room. Install a new 120/208 V emergency distribution panel DPE (sized as required) fed by a new ATS. Replace the existing 120/208 VAC, 600 A (MLO) electrical panel DPME and 120/208 VAC, 400 A (MLO) electrical panel DPTE with new panels fed from the new panel DPE. Remove the panel LA and transfer its circuits to the new panel DPME. Transfer the lighting circuit/s for mechanical room to the new panel DPME. Also, remove associated wiring and conduit not required by any existing electrical systems not being removed by this project. The project shall comply with applicable DOD, Air Force, and base design rules and standards. Proposals are not being requested or accepted at this time. As stipulated in FAR 15.201(e), responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. No solicitation (Request for Proposal) exists at this time; therefore, do not request a copy of the solicitation. The decision to solicit for a contract shall be solely within the Governments discretion. The Request for Proposal (RFP) will be available on SAM.gov on or about 16 July 2022\. Prospective contractors must be registered in the System for Award Management (SAM) database prior to award of a Government contract. Offerors are further advised that failure to register in the SAM database will render your firm ineligible for award. Registration requires applicants to have a DUNS number; recommend registering immediately in order to be eligible for timely award. The solicitation will be available only via the Internet at the following address: SAM.gov. For information on how to register your company on SAM.gov, to view or receive updates and notifications to the solicitation, please reference the guides located on the web site home page. NO paper copies of the impending solicitation will be furnished. The Government will be requesting that Proposal be valid until 31 December 2022\. Point of Contact: Mary E. Hallmon/Contracting Officer/Email: mary.hallmon@us.af.mil. 

<!-- mobian-agent-ad sponsored="true" id="dfde8091-4022-4353-b00b-be59ee39d64d" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Contacts

* Mary Hallmon

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/d7c5b6e1a83441dab789a9d624e8493f/view)

[More from United States Department of the Air Force posted in June 2022](/dept%5Fof%5Fthe%5Fair%5Fforce/archive/2022-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Upgrade the Emergency Power System at Building 104","description":"SYNOPSIS AT FA2823-22-R-0014 Eglin Air Force Base (AFB), FL has a requirement to provide all design and construction effort required to upgrade the Building 104, Eglin Radar Control Facility Emergency Power System on Eglin AFB, FL. The North American Industry Classification System (NAICS) code for this requirement is 236220 Commercial and Institutional Building Construction Contractors with a size standard of $39.5M. Statement of Magnitude is between $1,000,000 and $5,000,000. This is a Small Business Set-Aside competitive acquisition utilizing a best value source selection process and award will be made based upon the Best Value to the Government in accordance with FAR Part 15.3. This project includes, but is not limited to, the following: provide a new Emergency Power System that shall consolidate all mission critical electrical loads on one emergency generator and one automatic transfer switch (ATS). Replace 277/480 V, 800 A main distribution electrical panel MDP with new panel. Remove panel PC and transfer its circuits to new panel MDP. Remove 150 KVA and 225 KVA transformer banks, and replace with a new 480 V primary, 120/208 V secondary dry-type transformer (sized as required) fed from new panel MDP. Remove the 400 A safety switch feeding ATS #1, remove the 400 A technical ATS #1, and the 600 A mechanical ATS #2. Then, install a new 120/208 V, 4-pole, Bypass Isolation, and Closed Transition ATS (sized as required) fed from the new dry-type transformer referenced above. Install a new 120/208 V circuit breaker sized as required to feed the new ATS referenced above. Remove the existing 175 KW and 100 KW emergency generators and install a new 120/208 V emergency generator (sized as required) in the existing generator roomif possible. Remove the existing underground diesel fuel storage tank and fuel piping. Install a new 1,000 gallon above ground storage tank and fuel piping connected to new generator. Remove the two 25-gallon generator day tanks in the existing generator room. Install a new 120/208 V emergency distribution panel DPE (sized as required) fed by a new ATS. Replace the existing 120/208 VAC, 600 A (MLO) electrical panel DPME and 120/208 VAC, 400 A (MLO) electrical panel DPTE with new panels fed from the new panel DPE. Remove the panel LA and transfer its circuits to the new panel DPME. Transfer the lighting circuit/s for mechanical room to the new panel DPME. Also, remove associated wiring and conduit not required by any existing electrical systems not being removed by this project. The project shall comply with applicable DOD, Air Force, and base design rules and standards. Proposals are not being requested or accepted at this time. As stipulated in FAR 15.201(e), responses to this notice are not considered offers and cannot be accepted by the Government to form a binding contract. No solicitation (Request for Proposal) exists at this time; therefore, do not request a copy of the solicitation. The decision to solicit for a contract shall be solely within the Governments discretion. The Request for Proposal (RFP) will be available on SAM.gov on or about 16 July 2022. Prospective contractors must be registered in the System for Award Management (SAM) database prior to award of a Government contract. Offerors are further advised that failure to register in the SAM database will render your firm ineligible for award. Registration requires applicants to have a DUNS number; recommend registering immediately in order to be eligible for timely award. The solicitation will be available only via the Internet at the following address: SAM.gov. For information on how to register your company on SAM.gov, to view or receive updates and notifications to the solicitation, please reference the guides located on the web site home page. NO paper copies of the impending solicitation will be furnished. The Government will be requesting that Proposal be valid until 31 December 2022. Point of Contact: Mary E. Hallmon/Contracting Officer/Email: mary.hallmon@us.af.mil.","url":"https://matchawards.com/dept_of_the_air_force/posts/108424750712645083","identifier":"FA2823-22-R-0014","category":"236220 - Commercial and Institutional Building Construction","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"Z2JZ - REPAIR OR ALTERATION OF MISCELLANEOUS BUILDINGS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2022-06-05","availabilityEnds":"2022-06-20","areaServed":"FL-05, 32542","sameAs":"https://sam.gov/opp/d7c5b6e1a83441dab789a9d624e8493f/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```