<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/117277273266933152" -->

---
title: Stryker Surgical Video Equipment | Closed - MatchAwards
description: Stryker Surgical Video Equipment. United States Department of Veterans Affairs. Solicitation 36C25526Q0665_1. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2026-09-22. This solicitation is for the purchase of Brand Name Stryker Video Equipment for the Wichita VAMC. See...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/117277273266933152
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Stryker Surgical Video Equipment | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/117277273266933152
og:description: Stryker Surgical Video Equipment. United States Department of Veterans Affairs. Solicitation 36C25526Q0665_1. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2026-09-22. This solicitation is for the purchase of Brand Name Stryker Video Equipment for the Wichita VAMC. See...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Stryker Surgical Video Equipment

Status

Closed, the response deadline passed on Sep 22, 2026

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Presolicitation

Solicitation number

36C25526Q0665\_1

NAICS

[339112 - Surgical and Medical Instrument Manufacturing](/groups/582)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2026-09-15

Deadline

2026-09-22

Place of performance

Wichita, Kansas 67218, UNITED STATES

## Description

This solicitation is for the purchase of Brand Name Stryker Video Equipment for the Wichita VAMC. See the following Solicitation for further information.

<!-- mobian-agent-ad sponsored="true" id="3b8d9d46-60c4-42db-b20a-af8756d9fb0d" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


**Camera Control Unit**

Quantity: 6 EA

Specification/Salient Characteristics:

* Minimum resolution: 4K
* Scalable to accommodate future advancements in peripheral device integration and control
* The ability to assess perfusion for open surgery
* Intuitive capacitive touch screen LCD interface for ease of operation
* Capable of accommodating up to 10 different surgical specialties settings for optimal color resolution and brightness
* User-friendly and easily understood by nursing staff
* The ability/compatibility to see lighted ureteral stents that when placed, emits infrared light that can be detected to visualize the ureters (critical anatomy) in real time
* The ability to see fluorescence in 4K and lighted ureteral stents simultaneously
* CF Rated
* Capable of visualizing and highlighting lung and ovarian cancer
* Can showcase over 1 billion reproducible colors
* Includes dynamic range enhancements that improve visualization in both the highlights and shadows of the picture to increase clarity and details across the image
* Has technology been built into the system designed to reduce the effects of RF
* 5 advanced imaging modes of fluorescence for visualization to accommodate multiple specialties all in 4K

 **Light Source**

Quantity: 6 EA

Specification/Salient Characteristics:

* It has technology that is designed to increase patient and operating rooms safety by minimizing the amount of time the light source is on, making patient and drape burns less likely
* Gives real time adjustments of light output to optimize visualization in every surgical scene
* 2 infrared lasers for advanced imaging (fluorescence/lighted stents)
* Gives visualize feedback to showcase when light cable is properly seated

 **32” 4K Wireless Transmitter**

Quantity: 4 EA

Specification/Salient Characteristics:

* Wirelessly transmits 4K and 1080p signals
* Improve safety and workflow efficiencies in the OR
* Eliminate tripping hazards from cabling on the ground
* Enable a seamless linking process with LED confirmation & permanent and non-permanent pairing options

 **32” 4K Wireless Receiver**

Quantity: 3 EA

Specification/Salient Characteristics:

* Wirelessly receives 4K and 1080p signals
* Improve safety and workflow efficiencies in the OR
* Eliminate tripping hazards from cabling on the ground
* Enable a seamless linking process with LED confirmation & permanent and non-permanent pairing options

 **32” 4K OLED Surgical Display & Covers**

Quantity: 11 EA

Specification/Salient Characteristics:

* Resolution: 4096 x 2160
* Size: 32” corner to corner
* Ability to represent 1.07 billion different colors
* Offers crisp contrast ratio of 1,000,000:1
* OLED technology with self-illuminating pixels, eliminating the need for external backlighting
* 0.1 ms response time for no detectable image lag
* 14.0 lbs. for easy installation in both integrated and cart-based rooms
* 9 preset surgical specialties
* Includes 32" 4K OLED display covers

 **OLED Surgical Display Cover**

 Quantity: 11 EA

 Specifications/Salient Characteristics:

* Intended to protect your displays from scratches/damage prolonging your investment
* Easily removable for cleaning
* Quick and seamless “install”
* Highly durable

 **Camera Head**

Quantity: 12 EA

 Specification/Salient Characteristics:

* CMOS 3-Chip camera technology designed for enhanced light sensitivity and increased patient safety
* Programmable to control OR equipment from camera head
* Ergonomic lightweight design for minimally invasive surgery

 **Insufflator**

Quantity: 6 EA

 Specifications/Salient Characteristics:

* Enhances image clarity
* For laparoscopic and robotic surgery
* Removes surgical smoke for a safer work environment
* 6 unique operating modes
* All-inclusive system with integrated heating, humidification, and smoke evacuation capabilities
* 4 interchangeable tube set options

**Light Cable**

 Quantity: 12 EA

 Specifications/Salient Characteristics:

* Scope sensing technology that automatically turns the light off when the scope is disconnected from the light cable
* Fiber optic cable
* Compatible Advanced Imaging modes  
  * Fluorescence
  * Consistent lighting in small cavities
  * Auto light feature
  * Overlay mode to highlight ICG
  * Contrast mode

**Portable Handheld Fluorescence Imager**

 Quantity: 1 EA

 Specifications/Salient Characteristics:

* Intuitive operator controls
* Comfortable single-handed operation
* Indicated for fluorescence imaging of blood flow and tissue perfusion before, during, and after vascular, gastrointestinal, organ transplant, and plastic, microsurgical, and reconstructive surgical procedures
* System is used to perform intraoperative fluorescence imaging and visualization of the lymphatic system, including lymphatic vessels and lymph nodes
* 1080p x 60fps
* Indicated for use in adult and pediatric patients one month of age and older
* Combine enhanced fluorescence signal information with vivid white light images in real-time
* 4 fluorescence modes for visualization
* Software allows the surgeon to further evaluate the intensity of the fluorescence signal in real time through relative percentage values and a color maps mode
* The ability to visualize lymphatic channels through the skin.

**Portable Handled Fluorescence Imager Video Processor** 

 Quantity: 1 EA

 Specifications/Salient Characteristics:

* Features a timer that is automatically activated when fluorescence is detected, and icons indicating ingress and the fluorescence assessment window
* Involves no ionizing radiation and utilizes a non-nephrotoxic fluorescence imaging agent with a very short half-life thus allowing surgeons to repeat intraoperative perfusion assessment numerous times throughout the procedure
* The ability to visualize lymphatic channels through the skin.

## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ee87b671ef1945a3be20d8db21217d4c/download)

## Contacts

* Tracie Raggs

Email and phone are in the source notice.

[Source notice](https://sam.gov/workspace/contract/opp/cb213b027e684eed8a0f60d3f1ecb84d/view)

[More from United States Department of Veterans Affairs posted in September 2026](/department%5Fof%5Fveterans%5Faffairs/archive/2026-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Stryker Surgical Video Equipment","description":"This solicitation is for the purchase of Brand Name Stryker Video Equipment for the Wichita VAMC. See the following Solicitation for further information. Camera Control Unit Quantity: 6 EA Specification/Salient Characteristics: Minimum resolution: 4K Scalable to accommodate future advancements in peripheral device integration and control The ability to assess perfusion for open surgery Intuitive capacitive touch screen LCD interface for ease of operation Capable of accommodating up to 10 different surgical specialties settings for optimal color resolution and brightness User-friendly and easily understood by nursing staff The ability/compatibility to see lighted ureteral stents that when placed, emits infrared light that can be detected to visualize the ureters (critical anatomy) in real time The ability to see fluorescence in 4K and lighted ureteral stents simultaneously CF Rated Capable of visualizing and highlighting lung and ovarian cancer Can showcase over 1 billion reproducible colors Includes dynamic range enhancements that improve visualization in both the highlights and shadows of the picture to increase clarity and details across the image Has technology been built into the system designed to reduce the effects of RF 5 advanced imaging modes of fluorescence for visualization to accommodate multiple specialties all in 4K Light Source Quantity: 6 EA Specification/Salient Characteristics: It has technology that is designed to increase patient and operating rooms safety by minimizing the amount of time the light source is on, making patient and drape burns less likely Gives real time adjustments of light output to optimize visualization in every surgical scene 2 infrared lasers for advanced imaging (fluorescence/lighted stents) Gives visualize feedback to showcase when light cable is properly seated 32” 4K Wireless Transmitter Quantity: 4 EA Specification/Salient Characteristics: Wirelessly transmits 4K and 1080p signals Improve safety and workflow efficiencies in the OR Eliminate tripping hazards from cabling on the ground Enable a seamless linking process with LED confirmation \u0026 permanent and non-permanent pairing options 32” 4K Wireless Receiver Quantity: 3 EA Specification/Salient Characteristics: Wirelessly receives 4K and 1080p signals Improve safety and workflow efficiencies in the OR Eliminate tripping hazards from cabling on the ground Enable a seamless linking process with LED confirmation \u0026 permanent and non-permanent pairing options 32” 4K OLED Surgical Display \u0026 Covers Quantity: 11 EA Specification/Salient Characteristics: Resolution: 4096 x 2160 Size: 32” corner to corner Ability to represent 1.07 billion different colors Offers crisp contrast ratio of 1,000,000:1 OLED technology with self-illuminating pixels, eliminating the need for external backlighting 0.1 ms response time for no detectable image lag 14.0 lbs. for easy installation in both integrated and cart-based rooms 9 preset surgical specialties Includes 32\" 4K OLED display covers OLED Surgical Display Cover Quantity: 11 EA Specifications/Salient Characteristics: Intended to protect your displays from scratches/damage prolonging your investment Easily removable for cleaning Quick and seamless “install” Highly durable Camera Head Quantity: 12 EA Specification/Salient Characteristics: CMOS 3-Chip camera technology designed for enhanced light sensitivity and increased patient safety Programmable to control OR equipment from camera head Ergonomic lightweight design for minimally invasive surgery Insufflator Quantity: 6 EA Specifications/Salient Characteristics: Enhances image clarity For laparoscopic and robotic surgery Removes surgical smoke for a safer work environment 6 unique operating modes All-inclusive system with integrated heating, humidification, and smoke evacuation capabilities 4 interchangeable tube set options Light Cable Quantity: 12 EA Specifications/Salient Characteristics: Scope sensing technology that automatically turns the light off when the scope is disconnected from the light cable Fiber optic cable Compatible Advanced Imaging modes Fluorescence Consistent lighting in small cavities Auto light feature Overlay mode to highlight ICG Contrast mode Portable Handheld Fluorescence Imager Quantity: 1 EA Specifications/Salient Characteristics: Intuitive operator controls Comfortable single-handed operation Indicated for fluorescence imaging of blood flow and tissue perfusion before, during, and after vascular, gastrointestinal, organ transplant, and plastic, microsurgical, and reconstructive surgical procedures System is used to perform intraoperative fluorescence imaging and visualization of the lymphatic system, including lymphatic vessels and lymph nodes 1080p x 60fps Indicated for use in adult and pediatric patients one month of age and older Combine enhanced fluorescence signal information with vivid white light images in real-time 4 fluorescence modes for visualization Software allows the surgeon to further...","url":"https://matchawards.com/department_of_veterans_affairs/posts/117277273266933152","identifier":"36C25526Q0665_1","category":"339112 - Surgical and Medical Instrument Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2026-09-15","availabilityEnds":"2026-09-22","validThrough":"2026-09-22T23:59:59-04:00","areaServed":"Wichita, Kansas 67218, UNITED STATES","sameAs":"https://sam.gov/workspace/contract/opp/cb213b027e684eed8a0f60d3f1ecb84d/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```