B533--Legionella and Dental Water Line Sampling
- Status
- Closed, the response deadline passed on Jul 29, 2026
- Agency
- United States Department of Veterans Affairs
- Office
- TAMPA, USA
- Notice type
- Presolicitation
- Solicitation number
- 36C24826Q1019
- NAICS
- 541620 - Environmental Consulting Services
- PSC
- B533 - SPECIAL STUDIES/ANALYSIS- WATER QUALITY
- Category
- Management Advisory Services (2.3)
- Posted
- 2026-07-24
- Deadline
- 2026-07-29
- Place of performance
- UNITED STATES
Description
2 THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of a solicitation. The Department of Veterans Affairs (VA), VISN 8, Network Contracting Office 8 (NCO 8), is seeking information and potential qualified sources capable of meeting the following minimum requirements and salient characteristics below. PERFORMANCE WORK STATEMENT Legionella and Dental Water Line Sampling & Analysis and Water Management Plan Contract PLACE OF PERFORMANCE: James A. Haley Veterans Administration Medical Center (JAHVAMC) main campus at 13000 Bruce B. Downs Blvd Tampa FL, Primary Care Annex at 1315 Lake Terrace Ln. Tampa FL and New Port Richey VA Dental Clinic at 7900 Little Road New Port Richey FL. SCOPE OF WORK: The Contractor will provide all management, supervision, labor, materials, supplies and equipment, and will plan, schedule, coordinate and assure effective performance of all services described herein. This agreement will include the collection of water samples and the laboratory analysis of the collected water samples. Sampling will be conducted at the James Haley VA Hospital and its associated Outpatient Clinics. This requirement will be ONLY for the QUARTERLY water sampling and testing for Legionella, Dental Water Line and Ground Water Sampling. Vendors selected for this award will be excluded from all sales of products and equipment required to address issues identified associated with testing results. This is a Base plus four option year requirement. Please note the option years may be exercised after determination that it is in the best interest of the Government and it has been determined that it is the most advantageous method of fulfilling the Government s need for these services. SECURITY REQUIREMENTS: The C&A requirements do not apply, and a Security Accreditation Package is not required. DESCRIPTION OF SERVICE/GENERAL INFORMATION Hours of Operation and Scheduling: All work shall be accomplished during normal working hours 8:00AM - 5:00PM, Monday through Friday excluding Federal Holidays. This service is to collect water samples and analyze the collected water samples in a healthcare environment in accordance with current VA standards and directives. The contractor will demonstrate an adequate standard of care when performing the sampling and analysis of water samples by utilizing published or enunciated, peer reviewed industry appropriate standards of practice. Sampling Requirements: The collection of samples will be performed in accordance with the protocol established by the laboratory used to analyze the samples and will be collected by person(s) trained/experienced/certified and knowledgeable of appropriate potable and non-portable water sampling standards of practice and laboratory sampling protocol. Samples will be stored and shipped in accordance with the laboratory sampling protocol. The contractor will develop an annual schedule to include the dates and times planned to perform each quarterly sampling event. The schedule will consider all federally observed holidays. The schedule will be approved by the James Haley VA Hospital point of contact. The contractor will confirm the dates and times of each quarterly sampling event with the James Haley VA Hospital point of contact at least two weeks prior to arrival onsite. The contractor will be accompanied by James Haley VA Hospital staff during the course of the sampling as necessary. The contractor will not deviate from the original provisions of the contract unless specifically. SPECIFIC TASKS Legionella Specific Sampling Hot and Cold Potable Water Distribution System Outlet Sampling The contractor will sample outlets on designated buildings (Main Campus) hot and cold water distribution system(s) for Legionella on a quarterly basis (once per Federal Fiscal Year quarter). The Contractor will develop a routine sampling plan utilizing appropriate standards of practice to accommodate a stratified, random sampling methodology to ensure that samples are representative of all water lines and outlets during each quarterly sampling event. In addition to the protocol to be used for identifying the random sampling locations, the sampling plan will include, but is not limited to the following content: The sampling plan will include a means of easily identifying each sampled location (e.g., drawing, matrix, etc.) The sampling plan will include a means of identifying the distribution system (i.e., hot or cold) from which the sample was collected. Water Samples will be randomly collected from points in the water distribution systems listed in table 1 where the end user comes in contact with the water (e.g., faucets, showers, ice machines, and drinking fountains) and will be inclusive of all water lines and outlets. Samples will be collected in the quantities listed in table 1. The COR shall be notified immediately (within 1 hour) of any hot water temperatures greater than 110 degrees F. Cooling Tower System Sampling The Contractor will sample the cooling tower system(s) for Legionella on a quarterly basis (once per Federal Fiscal Year quarter). The contractor will develop a routine sampling plan utilizing appropriate standards of practice to accommodate an appropriate sampling methodology to ensure that samples are representative of the entire cooling tower system during each annual sampling event. The sampling plan will include, but is not limited to the following content and will be approved by the James Haley VA Hospital point of contact: The sampling plan will include a means of easily identifying each sampled location (e.g., drawing, matrix, etc.). The sampling plan will include a means of identifying the system from which the sample was collected. At a minimum, water samples will be collected from each cooling tower system at the basin or sump of the cooling tower at a location distant from the incoming make-up water. At the time each water sample is taken, the contractor will test and document the following for each sample: Water temperature, level of residual biocide, and pH. These water quality parameters will be tested in the field using appropriate test instruments, properly calibrated and traceable to a NIST standard. Table No. 1 Test Frequencies and Quantities Main Hospital and Primary Care Annex & NPR (Dental) Sampled System/Area Frequency * Legionella Test Bundle Total Heterotrophic Plate Count Oxidant Residual Water Quality Bundle Hot Water Distribution Outlets Quarterly 75 75 Cold Water Distribution Outlets Quarterly 75 75 Potable Water Supply Points of Entry Quarterly 3 3 3 Treadmill & Therapy Pool Quarterly 2 2 Cooling Towers Quarterly 10 10 10 Dental (PCA, TPA, Pasco) Quarterly 200 Sample Analysis Once collected, that contractor will have the samples processed by a testing laboratory with experience in microbial testing of potable and non-potable water. Analysis of water samples will be performed by a laboratory currently certified by the Centers for Disease Control and Prevention (CDC) Environmental Legionella Isolation Techniques Evaluation (ELITE) program as proficient at performing the culture of Legionella from environmental samples. Information about ELITE certified laboratories can be found at https://wwwn.cdc.gov/elite/Public/MemberList.aspx . In addition to the requirement for current CDC ELITE certification, the laboratory performing the analysis of water samples will have an environmental microbiology accreditation by a nationally recognized accrediting body (e.g., A2LA, NELAP). The laboratory will analyze each water sample for Legionella by performing the tests listed in the Legionella Test Bundle identified in table 2. The laboratory will have the capabilities of determining if the Legionella pneumophila is serogroup 1. When appropriate, the laboratory will concentrate water samples prior to plating the samples on selective media to increase the sensitivity of the assay. The Limit of Detection (LOD) used by the laboratory shall not be less than 0.4 CFU/ml. Example an LOD of 0.01 CFU/ml is NOT approved at this time. The laboratory will neutralize biocides that have been added to the building s potable water distribution systems prior to analysis. Rapid testing methods, such as polymerase chain reaction (PCR) and direct fluorescent antibody (DFA), are not permitted for the detection of Legionella in the water samples. The laboratory shall have the capability to store specimens in the event that molecular testing is required to investigate a possible hospital acquired Legionella disease case. Table 2 Legionella Test Bundle Temperature Residual Oxidant pH Legionella Serotypes - Lpn S1, Lpn S2-14, Legionella spp Legionella Analysis Reports Once analyzed, the laboratory will prepare and submit an analysis report to the James Haley VA Hospital point of contact. The analysis report will include an enumeration of Legionella concentrations for each result above the quantification limit. The analysis report will include the serogroup for all results determined to be above the quantification limit. All quantifiable/enumerated results will be reported in CFU/ml. All results determined to be below the quantification limit will be reported as Negative . Analysis reports will be submitted via email and hard copy to the James Haley VA Hospital point of contact. Analysis report data in CEOSH Excel spreadsheet format shall be sent via email to James Haley VA Hospital contact. The laboratory will have the capability to provide access to all sampling reports and supporting data through an internet-based tool at all times. Oxidant Residual Sampling Hot and Cold Potable Water Distribution System Outlet Sampling The contractor will sample outlets on each building s hot and cold water distribution system(s) for oxidant residual on a quarterly basis (once per Federal Fiscal Year quarter). The contractor will develop a routine sampling plan utilizing appropriate standards of practice to accommodate a stratified, random sampling methodology to ensure that samples are representative of all water lines and outlets during each quarterly sampling event. In addition to the protocol to be used for identifying the random sampling locations, the sampling plan will include, but is not limited to the following content and will be by the James Haley VA Hospital point of contact: The sampling plan will include a means of easily identifying each sampled location (e.g., drawing, matrix, etc.) The sampling plan will include a means of identifying the distribution system (i.e., hot or cold) from which the sample was collected. Water samples will be randomly collected from points in the water distribution systems listed in table 1 where the end user comes in contact with the water (e.g., faucets, showers, ice machines, and drinking fountains) and will be inclusive of all water lines and outlets. Samples will be collected in the quantities listed in table 1. The contractor will identify the applicable oxidant for which sampling and analysis will be performed and analyze samples for that oxidant only. Oxidant Residual Sample Analysis Once collected, the contractor will have the samples processed by a testing laboratory with experience in testing of potable and non-potable water. Analysis of water samples will be performed by a laboratory currently certified by the Florida Department of Health to perform microbiological analysis of public drinking water. The laboratory will be proficient at performing the analysis of oxidant residual using ASTM method D1253-86: Standard Test Method for Residual Chlorine in Water from environmental samples. In addition to the requirement for current Florida DOH certification, the laboratory performing the analysis of water samples will have an environmental microbiology accreditation by a nationally recognized accrediting body (e.g., A2LA, NELAP). The laboratory will analyze each water sample for oxidant residual using ASTM method D1253-86: Standard Test Method for Residual Chlorine in Water or equivalent method utilized to quantify the residual concentration of the oxidant in use. Oxidant Residual Analysis Reports Once analyzed, the laboratory will prepare and submit an analysis report to the James Haley VA Hospital point of contact. The analysis report will include an enumeration of oxidant residual concentrations for each result above the quantification limit. All qualifiable/enumerated results will be reported in mg/L. All results will be compared against the following minimum oxidant residual concentrations as applicable: Chlorine (as free Chlorine) 0.5mg/L Monochloramine 0.5mg/L Chlorine Dioxide 0.3mg/L All sample results exceeding the defined action levels will be conspicuously identified in the analysis report Analysis reports will be submitted via email and hard copy to the James Haley VA Hospital point of contact. The laboratory will have the capability to provide access to all sampling reports and supporting data through an internet-based tool at all times. Oxidant residual results will be reported within 3 days (48-72 hours for analysis and 1 day for handling). Potable Water Quality Supply Sampling The contractor will sample outlets on each building s potable water supply for water quality on a quarterly basis (once per Federal Fiscal Year quarter). The contractor will develop a routine sampling plan utilizing appropriate standards of practice to accommodate an appropriate sampling methodology to ensure that samples are representative of incoming supply of potable water during each annual sampling event. The sampling plan will include, but is not limited to the following content and will be approved by the James Haley VA Hospital point of contact: The sampling plan will include a means of easily identifying the sampled location (e.g., drawing, matrix, etc.) The sampling plan will include a means of identifying the system from which the sample was collected. At a minimum, water samples will be collected from the incoming potable water supply to the buildings. Samples will be collected in the quantities listed in table 1. The temperature of each sample will be taken at the time of collection. Potable Water Quality Analysis Once collected, that contractor will have the samples processed by a testing laboratory with experience in testing of potable and non-potable water. Analysis of water samples will be performed by a laboratory currently certified by the Florida Department of Health (DOH) to perform microbiological analysis of public drinking water. The laboratory will be proficient at performing the water quality test methods listed in table 3. In addition to requirement for current Florida DOH certification, the laboratory performing the analysis of water samples will have an environmental microbiology accreditation by a nationally recognized accrediting body (e.g., A2LA, NELAP). The laboratory will analyze each water sample for the total suspended solids, pH, and hardness using the approved test methods listed in table 3. Potable Water Quality Analysis Reports Once analyzed, the laboratory will prepare and submit an analysis report to the James Haley VA Hospital point of contact. The analysis report will include an enumeration of water quality concentrations for each result above the quantification limit. All quantifiable/enumerated will be reported in the following units: TSS - mg/L Hardness mg/L as CaCO3 pH pH units All results will be compared against the following maximum and minimum drinking water quality standards as applicable. All sample results determined to be above or below the drinking water quality standards will be conspicuously identified in the analysis report. Water temperatures taken at the time the sample was collected will be included on the analysis report for each sample. Analysis reports will be submitted via email and hard copy to the James Haley VA Hospital point of contact. The laboratory will have the capability to provide access to all sampling reports and supporting data through an internet-based tool at all times. Water Quality results will be reported within 3 days (48-72 hours for analysis and 1 day for handling). The laboratory will have the capability to provide access to all sampling reports and supporting data through an internet-based tool at all times. Table No. 3 Water Quality Test Bundle Test Acceptable Methods Total Suspended Solids (TSS) EPA Method: 160.2 pH Standard Method 4500H EPA Method 150.1 EPA Method 150.2 Hardness Standard Method 2340 EPA Method 130.2 Heterotrophic Plate Count Specific Sampling (Dental Water Line Sampling) The contractor will sample the contractor will sample Dental Water Lines for Heterotrophic Plate Count on a quarterly basis (once per Federal Fiscal Year quarter). Contractor will develop a routine sampling plan utilizing appropriate standards of practice to accommodate a sampling methodology to ensure that samples are representative of all water lines and outlets during each quarterly sampling event. The sampling plan will be consistent with the James Haley VA Hospital Dental Service Waterline Testing and Treatment Standard Operating Procedure. Dental Water Line sampling requires the manipulation of instruments and equipment. Special instructions or assistance from James Haley VA Hospital will be necessary to collect the samples appropriately and safety and in order to prevent damage to equipment. In addition to protocol to be used for identifying the sampling locations, the sampling plan will include, but is not limited to the following content and will be approved by the James Haley VA Hospital point of contact: The sampling plan will include a means of easily identifying each sampled location (e.g., drawing, matrix, etc.) The sampling plan will include a means of identifying the distribution system (i.e., hot or cold) from which the sample was collected. Samples will be collected in the quantities listed in table 1 and as defined in the James Haley VA Hospital Dental Service Waterline Testing and Treatment Standard Operating Procedure. Heterotrophic Plate Count Sample Analysis Once collected, the contractor will have the samples processed by a testing laboratory with experience in microbial testing of potable and non-potable water. Analysis of water samples will be performed by a laboratory currently certified by the Florida Department of Health to perform microbiological analysis of public drinking water. The laboratory will be proficient at performing the analysis of Heterotrophic Plate Count (HPC) using EPA/ELAP method SM 9215B from environmental samples. In addition to the requirement for current Florida EPA certification, the laboratory performing the analysis of water samples will have an environmental microbiology accreditation by a nationally recognized accrediting body (e.g., A2LA, NELAP). The laboratory will analyze each water sample for Heterotrophic Plate Count (HPC) using EPA/ELAP method SM 9215B. Heterotrophic Plate Count Analysis Report Once analyzed, the laboratory will prepare and submit an analysis report to the James Haley VA Hospital point of contact. The analysis report will include an enumeration of Heterotrophic Plate Count concentrations for each result above the quantification limit. All quantified/enumerated results will be reported in CFU/ml. All results determined to be below the quantification limit will be reported as Negative . All results will be compared against the action levels listed in the James Haley VA HoAttachments
Contacts
- Walida Moore-Saintil, Contract Officer Specialist
Email and phone are in the source notice.
More from United States Department of Veterans Affairs posted in July 2026