<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/116960176193237606" -->

---
title: J046--Installation and Maintenance for Water… (36C24126Q0489) | Closed - MatchAwards
description: J046--Installation and Maintenance for Water Monitoring System  at the Bedford VA Medical Center. United States Department of Veterans Affairs. Solicitation 36C24126Q0489. NAICS 221310 - Water Supply and Irrigation Systems. Total small business set-aside. Deadline 2026-08-13. 2 Description This...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/116960176193237606
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J046--Installation and Maintenance for Water… (36C24126Q0489) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/116960176193237606
og:description: J046--Installation and Maintenance for Water Monitoring System  at the Bedford VA Medical Center. United States Department of Veterans Affairs. Solicitation 36C24126Q0489. NAICS 221310 - Water Supply and Irrigation Systems. Total small business set-aside. Deadline 2026-08-13. 2 Description This...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J046--Installation and Maintenance for Water Monitoring System at the Bedford VA Medical Center

Status

Closed, the response deadline passed on Aug 13, 2026

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TOGUS, USA

Notice type

Combined Synopsis/Solicitation

Solicitation number

36C24126Q0489

NAICS

[221310 - Water Supply and Irrigation Systems](/groups/204)

PSC

J046 - MAINT/REPAIR/REBUILD OF EQUIPMENT- WATER PURIFICATION AND SEWAGE TREATMENT EQUIPMENT

Category

[Industrial Products Install / Maintenance / Repair (5.5)](/categories/industrial-products-and-services/industrial-products-install-maintenance-repair)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2026-07-21

Deadline

2026-08-13

## Description

2 Description This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) part 12, Acquisition of Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01, dated 3/13/2026\. This solicitation is a Small Business set aside. The associated North American Industrial Classification System (NAICS) code for this procurement is 221310, with a small business size standard of $41.0 million. The FSC/PSC is J046\. The Bedford VA Medical center located at 200 Springs Rd in Bedford, MA 01730 is seeking to purchase services to provide Repair and Maintenance Service for a Water Monitoring System at the Bedford VA Medical Center. Wage Determination 2015-4047 is applicable (see Attachment 1). This requirement contains references to Phigenics equipment and systems. These references establish the level of quality, characteristics, and functionality required. In accordance with FAR 11.104 and FAR 52.211-6, Phigenics brand name or equal products and services will be accepted if they meet or exceed the salient characteristics described in this solicitation. Statement of Work Water Management Equipment, Parts, and Monitoring Services Veterans Affairs Medical Center Bedford, MA 1\. PURPOSE AND SCOPE The VA Bedford Healthcare System requires equipment, parts, and ongoing monitoring services to support its Water Management Program (WMP) in compliance with VHA Directive 1061(4), Prevention of Health Care-Associated Legionella Disease and Scald Injury from Water Systems (February 16, 2021, as amended). The contractor shall provide chlorine monitoring systems, associated consumables and replacement parts, technical support, and continuous remote water analytics services across all applicable buildings on the Bedford campus. 2\. APPLICABLE REGULATIONS AND STANDARDS The contractor shall perform all work in accordance with: VHA Directive 1061(4) and all amendments (most recently October 21, 2024) EPA regulations at 40 C.F.R. Parts 141 142 ASHRAE Standard 188-2018, Legionellosis: Risk Management for Building Water Systems ASHRAE Guideline 12-2020 International Plumbing Code (IPC) American Water Works Association (AWWA) standards All applicable state and local drinking water regulations 3\. DELIVERABLES AND SERVICES 3.1 Equipment and Parts (Base Year) The contractor shall furnish and deliver all equipment and parts in accordance with the Price/Cost Schedule. Base Year equipment deliverables include: A Tubing + B Tubing Pairs (WME-3990): 24 pairs to support reagent delivery to CLX chlorine analyzers across monitored systems to ensure accurate parameter readings. pH Sensors (WME-2520): 7 sensors to support water quality parameter monitoring at designated system locations. Three-Foot Intake Tubing (WME-3990): 1 unit for Building 7, Room 233a. Pressure Regulators (WME-1915): 3 units for designated hot water locations to maintain consistent flow and support engineering control compliance. CLX Chlorine Monitors (WME-500): 12 units to support continuous biocide residual monitoring at water system management points throughout applicable buildings, consistent with the continuous monitoring requirements of VHA Directive 1061(4), Appendix A, paragraph 2.a. These will replace certain existing units already installed on Bedford s campus. All equipment shall be delivered in new condition, properly packaged, and accompanied by manufacturer documentation, installation guidance, and applicable warranties. Delivery shall be coordinated with the Contracting Officer's Representative (COR) to ensure minimal disruption to facility operations. 3.2 Technical Support and Start-Up (WME-9950 / WME-9974) The contractor shall provide on-site technical support and system start-up services, to include: Installation verification and commissioning of all CLX Chlorine Monitors and associated components delivered under this contract. Confirmation that all systems are communicating with the Phigenics Data Exchange (PDX) unit and transmitting data to phiAnalytics. Calibration of all installed sensors, including chlorine, pH, conductivity, and temperature sensors, as applicable to system type. Initial operational and overview training for VA Bedford facility engineering staff on PWA system operation, data interpretation, and basic troubleshooting, consistent with the training requirements embedded in the PWA base and advanced service scopes. Completion and submission of a start-up service report within phiAnalytics upon conclusion of start-up activities. Technical support shall be performed by qualified Phigenics personnel. The contractor shall coordinate all site visits in advance with the COR. All personnel entering VA premises shall comply with applicable VA credentialing, badging, and safety requirements. 3.3 PWA Base Monitoring System Service 2.0 WMS-1075 The contractor shall provide ongoing monitoring and maintenance services for 19 PWA base monitoring systems throughout the applicable period of performance. Services under this line item are provided at a flat monthly fee per system and shall include: 3.3.1 Chlorine Analyzer Maintenance Test CLX flow function at each scheduled service visit. Perform calibration of the CLX chlorine analyzer as necessary to maintain measurement accuracy. 3.3.2 Consumable Replacement The contractor shall supply and replace all consumables required for continued accurate system performance, including: Monthly: CLX reagents necessary for colorimetric chlorine measurement. Annually: Reagent tubing and replacement cuvette kits. As Needed: CLX check valve sets, replaced upon identification of wear or failure affecting system performance. 3.3.3 Cellular Connectivity and Data Transmission Provide and maintain monthly cellular service for the Phigenics Data Exchange (PDX) unit at each monitored system location, enabling continuous transmission of water quality monitoring parameters to phiAnalytics. Confirm cellular data connection at each scheduled service visit. Provide basic remote troubleshooting of connectivity issues and communicate recommended corrective actions to the facility. Notify the VA Bedford facility via email in the event of PDX connectivity loss occurring between scheduled service visits. 3.3.4 Reporting and Documentation Complete a PWA service report within phiAnalytics following each service visit, documenting work performed, calibration results, consumables replaced, and any issues identified. 3.3.5 Training Provide PWA system overview and operational training to facility engineering staff during initial system start-up. 3.4 PWA Advanced Monitoring System Service 2.0 WMS-1175 The contractor shall provide ongoing monitoring and maintenance services for 7 PWA advanced monitoring systems throughout the applicable period of performance. All services described under WMS-1075 (Section 3.3) are included. In addition, the following enhanced services shall be provided: 3.4.1 Multi-Parameter Sensor Calibration Calibrate conductivity, temperature, and pH sensors on a monthly basis to ensure continuous accuracy of multi-parameter water quality data transmitted to phiAnalytics. 3.4.2 Enhanced Annual Consumable Replacement Annually: Replace reagent tubing and cuvette kits, replacement cuvette, and pH sensor cartridge to maintain system accuracy and reliability over time. 3.4.3 Reporting and Documentation Complete a PWA service report within phiAnalytics following each service visit, consistent with the requirements described under WMS-1075\. 3.5 phiAnalytics Software Service WMS-520 The contractor shall provide continuous access to the phiAnalytics web-based water analytics platform for the duration of each contract period. This platform shall serve as the central repository for all water quality data collected by the PWA systems and shall support the VA Bedford facility's obligations under VHA Directive 1061(4) for data review, trend analysis, and documentation of engineering control performance. The platform shall maintain a complete digital record of monitoring data, alerts, and corrective actions. Visual reports of continuous data monitoring shall be available. The phiAnalytics software must allow users to establish and manage defined control limits for each required parameter with immediate alerts generated if a limit is exceeded. All records management with phiAnalytics shall be managed by NARA approved schedules found in VHA Records Control Schedule 10-1\. The platform shall remain operational and accessible 24 hours per day, 7 days per week. 4\. COMPLIANCE WITH VHA DIRECTIVE 1061(4) 4.1 Continuous Monitoring Support All PWA systems furnished and maintained under this contract shall support the continuous monitoring requirements of VHA Directive 1061(4), Appendix A, paragraph 2.a., by providing ongoing measurement and data transmission of the following parameters at applicable water system management points: Biocide (free chlorine) residual levels Water temperature pH Conductivity (advanced systems) Data shall be transmitted to phiAnalytics and shall be available for facility staff to review instantly. VA Bedford staff will review weekly in accordance with the directive's requirements. 4.2 Engineering Control Limits The monitoring systems shall be configured to support VA Bedford's established engineering control limits, including but not limited to: Minimum free chlorine residual of 0.5 mg/L at hot and cold water outlets, consistent with Appendix A, paragraph 2.c.(2). Hot water distribution system temperatures at or above 124Â°F (51.1Â°C) in system piping prior to mixing valves, consistent with Appendix A, paragraph 2.b.(1). Cold water temperatures at or below 67Â°F (19.4Â°C) to the greatest extent practicable, consistent with Appendix A, paragraph 2.b.(2). The contractor's monitoring systems are not responsible for implementing or enforcing these controls, but shall provide the data necessary for VA Bedford engineering staff to assess compliance and initiate corrective actions. 4.3 Corrective Action Notification The phiAnalytics platform shall be configured to alert designated VA Bedford facility personnel immediately when monitored parameters approach or exceed established control limits, supporting the facility's obligation to promptly assess and implement corrective actions as required by Appendix A, paragraph 2.d. All remediation actions must be documented in phiAnalytics by VA Bedford staff or the software will view the alarm as incomplete. 4.4 Environmental Legionella Testing Support While environmental Legionella culture testing is not within the scope of this contract, the data generated by PWA systems shall support the facility's quarterly environmental validation program by providing contemporaneous records of water temperature, pH, and biocide residual levels at sampled locations, as referenced in Appendix C, paragraph 2.a.(1). 5\. PERIOD OF PERFORMANCE Period Description Base Year Equipment, start-up, and 12 months of monitoring services Option Year 1 12 months of monitoring services Option Year 2 12 months of monitoring services Option Year 3 12 months of monitoring services Option Year 4 12 months of monitoring services Option years cover ongoing monitoring services only. Equipment and start-up costs are limited to the Base Year. Monthly service rates are fixed for each contract period as specified in the Price/Cost Schedule and reflect gradual annual increases across option years. 6\. EXCLUSIONS The following services are outside the scope of this contract. If out-of-scope services are identified during the execution of work, the contractor shall provide a separate proposal with applicable scope and pricing prior to performing any such work: Replacement of non-consumable internal components of the chlorine analyzer, including pressure regulators and solenoids. Replacement of sensor housings. Replacement of liquid end components on any chlorine dosing pump. Relocation of PDX units or installation of antenna extenders required to resolve persistent cellular connectivity issues (may be proposed separately if required). Response to or resolution of low or high chlorine alarms generated by phiAnalytics the facility's engineering staff are responsible for alarm response and corrective action logging. Routine review of phiAnalytics PWA charts and logs this responsibility rests with VA Bedford facility staff. Logging of corrective actions within phiAnalytics this responsibility rests with VA Bedford facility staff in accordance with VHA Directive 1061(4). 7\. CONTRACTOR PERSONNEL AND QUALIFICATIONS All contractor personnel performing on-site services shall be qualified Phigenics technicians trained in the operation, calibration, and maintenance of PWA system components. The contractor shall maintain documentation of personnel qualifications and make such documentation available to the COR upon request. In accordance with VHA Directive 1061(4), paragraph 5.j.(11), the VA Medical Facility Chief Engineer shall assess and document the competency of the contractor and contractor personnel as part of the acquisition process and on an ongoing basis, no less than annually. 8\. CONTRACTOR RESPONSIBILITIES The contractor shall: Coordinate all scheduled site visits with the COR no less than five (5) business days in advance. Comply with all VA badging, credentialing, and site access requirements. Maintain all required licenses, certifications, and state operating permits necessary to provide water treatment monitoring services. Retain records of all service visits, calibrations, and consumable replacements and make such records available to the COR upon request. Notify the COR promptly of any system anomaly, malfunction, or data gap that may affect the accuracy of water quality monitoring data. Ensure phiAnalytics remains continuously accessible and operational throughout the period of performance. 9\. GOVERNMENT RESPONSIBILITIES VA Bedford Healthcare System shall: Provide the contractor with safe and timely access to all PWA system locations during scheduled service visits. Designate a Contracting Officer's Representative (COR) to serve as the primary point of contact for all technical and operational matters under this contract. Review phiAnalytics data on a minimum weekly basis and take appropriate corrective action when engineering control limits are exceeded, as required by VHA Directive 1061(4). Respond to and log corrective actions for system alarms within phiAnalytics. Conduct all required quarterly environmental Legionella water testing, clinical validation activities, and reporting obligations in accordance with VHA Directive 1061(4), Appendices C and D. Maintain the Facility Water Safety Committee and all associated reporting and documentation obligations independent of this contract. END OF STATEMENT OF WORK The contract period Base plus 4 (one-year option periods). (Dates will be adjusted based on time of award) Base Year Pricing: 08/03/2026 08/02/2027 Option Year 1: 08/03/2027 08/02/2028 Option Year 2: 08/03/2028 08/02/2029 Option Year 3: 08/03/2029 08/02/2030 Option Year 4: 08/03/2030 08/02/2031 Place of Performance/Place of Delivery Address: Bedford VA Medical Center 200 Springs Road, Bedford, MA Postal Code: 01730 Country: UNITED STATES The following solicitation provisions apply to this acquisition: FAR 52.211-6, Brand Name or Equal (AUG 1999) FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services All offerors shall submit the following: Attachment 2 - Price Schedule Attachment 3 - Past Performance Worksheet Documentation required to demonstrate Brand Name or Equal compliance per FAR 52.211-6\. Offerors shall submit a technical narrative (not to exceed five pages) demonstrating the quoter's capability and approach to performing all services described in the Statement of Work, to include: PWA base and advanced monitoring system maintenance, sensor calibration, cellular connectivity management, consumable replacement, and phiAnalytics platform access and ongoing support. For Brand Name or Equal items, quoters shall provide a salient characteristics matrix demonstrating that proposed products meet or exceed the characteristics specified in the SOW per FAR 52.211-6\. Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/. FAR 52.212-2 Evaluation-Commercial Products and Commercial Services ADDENDUM to 52.212-2 EVALUATION COMMERCIAL PRODUCTS AND COMMERCIAL SERVICES (a) Basis for Award. The Government will issue a purchase order to the responsible quoter whose quotation conforming to the solicitation will be most advantageous to the Government, price and other factors considered. This acquisition is conducted using simplified acquisition procedures for the acquisition of commercial products and commercial services. The Government will evaluate quotations using a comparative evaluation process where quotations will be compared to one another to determine which provides the best benefit to the Government. The Government reserves the right to consider a quotation other than the lowest price that provides additional benefit(s). Each response must meet the minimum requirements of the solicitation. (b) The following factors shall be used to evaluate quotations: (1) Technical (2) Past Performance (3) Price (c) Evaluation Approach. The Government will evaluate quotations using the comparative evaluation process outlined in FAR 13.500 where quotations will be compared to one another to determine which provides the best benefit to the Government. The Government reserves the right to consider a quotation other than the lowest price that provides additional benefit(s). Quotations may exceed minimum requirements of the solicitation. The Government reserves the right to select a quotation that provides benefit to the Government that exceeds the minimum requirements of the solicitation, but is not required to do so. Each response must meet the minimum requirements of the solicitation. The Government is not requesting or accepting alternate quotations. The evaluation will consider the following: (1) Technical: The quotation will be evaluated to the extent to which it can meet and/or exceed the Government s requirements as outlined in the solicitation and based on the information requested in the instructions to quoters section of the solicitation. (2) Past Performance: The past performance evaluation will assess the relative risks associated with a quoter s likelihood of success in fulfilling the solicitation s requirements as indicated by the quoter s record of past performance. The past performance evaluation may be based on the contracting officer s knowledge of and previous experience with the supply or service being acquired; Customer surveys, and past performance questionnaire replies; Contractor Performance Assessment Reporting System (CPARS) at http://www.cpars.gov/; or any other reasonable basis. (3) Price: The Government will evaluate the price by adding the total of all line item prices, including all options The Total Evaluated Price will be that sum. (d) Options. The Government will evaluate quotations for award purposes by adding the total price for all options to the total price for the basic requirement. This includes options under FAR 52.217-8, Option to Extend Services, which applies to this solicitation. Evaluation of options under FAR 52.217-8 will be accompl 

<!-- mobian-agent-ad sponsored="true" id="449927fb-09c9-4561-afc0-5249fbe2252d" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/11c02866125e4e76970c6ce43ae3e1ae/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2d7be664006246fbb5d3109e177197c5/download)

## Contacts

* Yolanda Rankin, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/workspace/contract/opp/314b3c5f20b945e3800dcbee4ee2f733/view)

[More from United States Department of Veterans Affairs posted in July 2026](/department%5Fof%5Fveterans%5Faffairs/archive/2026-07)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J046--Installation and Maintenance for Water Monitoring System  at the Bedford VA Medical Center","description":"2 Description This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) part 12, Acquisition of Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01, dated 3/13/2026. This solicitation is a Small Business set aside. The associated North American Industrial Classification System (NAICS) code for this procurement is 221310, with a small business size standard of $41.0 million. The FSC/PSC is J046. The Bedford VA Medical center located at 200 Springs Rd in Bedford, MA 01730 is seeking to purchase services to provide Repair and Maintenance Service for a Water Monitoring System at the Bedford VA Medical Center. Wage Determination 2015-4047 is applicable (see Attachment 1). This requirement contains references to Phigenics equipment and systems. These references establish the level of quality, characteristics, and functionality required. In accordance with FAR 11.104 and FAR 52.211-6, Phigenics brand name or equal products and services will be accepted if they meet or exceed the salient characteristics described in this solicitation. Statement of Work Water Management Equipment, Parts, and Monitoring Services Veterans Affairs Medical Center Bedford, MA 1. PURPOSE AND SCOPE The VA Bedford Healthcare System requires equipment, parts, and ongoing monitoring services to support its Water Management Program (WMP) in compliance with VHA Directive 1061(4), Prevention of Health Care-Associated Legionella Disease and Scald Injury from Water Systems (February 16, 2021, as amended). The contractor shall provide chlorine monitoring systems, associated consumables and replacement parts, technical support, and continuous remote water analytics services across all applicable buildings on the Bedford campus. 2. APPLICABLE REGULATIONS AND STANDARDS The contractor shall perform all work in accordance with: VHA Directive 1061(4) and all amendments (most recently October 21, 2024) EPA regulations at 40 C.F.R. Parts 141 142 ASHRAE Standard 188-2018, Legionellosis: Risk Management for Building Water Systems ASHRAE Guideline 12-2020 International Plumbing Code (IPC) American Water Works Association (AWWA) standards All applicable state and local drinking water regulations 3. DELIVERABLES AND SERVICES 3.1 Equipment and Parts (Base Year) The contractor shall furnish and deliver all equipment and parts in accordance with the Price/Cost Schedule. Base Year equipment deliverables include: A Tubing + B Tubing Pairs (WME-3990): 24 pairs to support reagent delivery to CLX chlorine analyzers across monitored systems to ensure accurate parameter readings. pH Sensors (WME-2520): 7 sensors to support water quality parameter monitoring at designated system locations. Three-Foot Intake Tubing (WME-3990): 1 unit for Building 7, Room 233a. Pressure Regulators (WME-1915): 3 units for designated hot water locations to maintain consistent flow and support engineering control compliance. CLX Chlorine Monitors (WME-500): 12 units to support continuous biocide residual monitoring at water system management points throughout applicable buildings, consistent with the continuous monitoring requirements of VHA Directive 1061(4), Appendix A, paragraph 2.a. These will replace certain existing units already installed on Bedford s campus. All equipment shall be delivered in new condition, properly packaged, and accompanied by manufacturer documentation, installation guidance, and applicable warranties. Delivery shall be coordinated with the Contracting Officer's Representative (COR) to ensure minimal disruption to facility operations. 3.2 Technical Support and Start-Up (WME-9950 / WME-9974) The contractor shall provide on-site technical support and system start-up services, to include: Installation verification and commissioning of all CLX Chlorine Monitors and associated components delivered under this contract. Confirmation that all systems are communicating with the Phigenics Data Exchange (PDX) unit and transmitting data to phiAnalytics. Calibration of all installed sensors, including chlorine, pH, conductivity, and temperature sensors, as applicable to system type. Initial operational and overview training for VA Bedford facility engineering staff on PWA system operation, data interpretation, and basic troubleshooting, consistent with the training requirements embedded in the PWA base and advanced service scopes. Completion and submission of a start-up service report within phiAnalytics upon conclusion of start-up activities. Technical support shall be performed by qualified Phigenics...","url":"https://matchawards.com/department_of_veterans_affairs/posts/116960176193237606","identifier":"36C24126Q0489","category":"221310 - Water Supply and Irrigation Systems","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J046 - MAINT/REPAIR/REBUILD OF EQUIPMENT- WATER PURIFICATION AND SEWAGE TREATMENT EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.5 Industrial Products Install / Maintenance / Repair","url":"https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair"}],"availabilityStarts":"2026-07-21","availabilityEnds":"2026-08-13","validThrough":"2026-08-13T23:59:59-04:00","sameAs":"https://sam.gov/workspace/contract/opp/314b3c5f20b945e3800dcbee4ee2f733/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```