<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/116716931627371795" -->

---
title: AMSCO 50 - series 3 - Bay Sink | Closed - MatchAwards
description: AMSCO 50 - series 3 - Bay Sink. United States Department of Veterans Affairs. Solicitation 36C25526Q0442. NAICS 327110 - Pottery, Ceramics, and Plumbing Fixture Manufacturing. Total small business set-aside. Deadline 2026-06-17. 1. STATEMENT OF WORK The contractor shall furnish all necessary...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/116716931627371795
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: AMSCO 50 - series 3 - Bay Sink | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/116716931627371795
og:description: AMSCO 50 - series 3 - Bay Sink. United States Department of Veterans Affairs. Solicitation 36C25526Q0442. NAICS 327110 - Pottery, Ceramics, and Plumbing Fixture Manufacturing. Total small business set-aside. Deadline 2026-06-17. 1. STATEMENT OF WORK The contractor shall furnish all necessary...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# AMSCO 50 - series 3 - Bay Sink

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Solicitation

Solicitation number

36C25526Q0442

NAICS

[327110 - Pottery, Ceramics, and Plumbing Fixture Manufacturing](/groups/390)

PSC

4510 - PLUMBING FIXTURES AND ACCESSORIES

Category

[Facility Related Materials (4.3)](/categories/facilities-and-construction/facility-related-materials)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2026-06-08

Deadline

2026-06-17

Place of performance

Kansas City, Missouri 64128, UNITED STATES

## Description

**1\. STATEMENT OF WORK**

The contractor shall furnish all necessary services, labor, travel, transportation, materials, shipping, parts, connections, and equipment. This includes the provision and on-site installation of at least 5 AMSCO 50 Series Reprocessing Sinks at 4801 Linwood Blvd, Kansas City MO 64128\. These reprocessing sinks are required by the Sterile Processing Services (SPS) to facilitate the manual cleaning of sterilization-compatible reusable medical devices (RMD) in invasive procedures. Their use will support a range of medical procedures and surgeries, including those in the operating room, dental services, procedural gastroenterology, procedural pulmonology and surgical clinics.

The contractor bears the responsibility for the removal and disposal of all debris and packaging materials resulting from the reprocessing sinks installation. Prior to equipment utilization, the contractor is required to provide training to clinical staff, with all duty tours for the sterile processing department being documented.

The scope of this contract comprises five AMSCO 50 Series Reprocessing Sinks. Associated services include complete installation components, execution of a post-installation check-out test, and implementation of any necessary adjustments.

2\. SPECIFICATIONS

* Minimum of five 3 Bay 97.5” x 28” x 33”- 41” Adjustable Height Reprocessing Sinks.  
  * Installer Must Maintain a Minimum Gap of .875” To All Adjacent Walls as a Pinch Point Protection.
  * Unit Must Be Installed Against a Wall, For Back-to-Back Installation a Pony Wall is Required.
  * 304 Stainless Steel Construction.
  * Pony Wall Must Be 53”
  * Wall Must Be Free of Obstructions to 54”
* Utility requirements (plumbing)  
  * Hot Water (HW)
1. Connection Type/Size- 3/8” COMPRESSION
2. Pressure Range- 15 to 125PSI
3. Operating Flow Rate- 1.6GPM @ MAX PSI
4. Temperature Range 40° to 180°F
5. Water Quality- Steris recommends the following water quality parameters:
* 100-200 PPM (500PPM MAX) TOTAL DISOLVED SOLIDS.
* 71-120 PPM (180PPM MAX) TOTAL ALKALINITY.
* 6.8-7.0PH (7.5 MAX).
* 0.1-0.5PPM (1.0) TOTAL SILICA.  
  * Cold Water (CW)
1. Connection Type/Size- 3/8” COMPRESSION
2. Pressure Range- 15 to 125PSI
3. Operating Flow Rate- 1.6GPM @ MAX PSI
4. Temperature Range- 70° F MAX
5. Water Quality- Steris Recommends The Following Water Quality Parameters:
* 100-200 PPM (500PPM MAX) TOTAL DISOLVED SOLIDS.
* 71-120 PPM (180PPM MAX) TOTAL ALKALINITY.
* 6.8-7.0PH (7.5 MAX).
* 0.1-0.5PPM (1.0) TOTAL SILICA  
  * PURE WATER (PW)
1. Connection Type/Size- ½” NPT
2. Pressure Range- 20 TO 125 PSI
3. Operating Flow Rate- .25 TO 2.0 GPM 15%
4. Temperature Range- 40° F to 140° F  
  * WATER GUN (WG)
1. Connection type/size- 3/8” Compression
2. Pressure Range- 0 TO 44 PSI
3. Temperature Range- 40° TO 125°
4. Water Quality- Recommendations listed under #5 of (HW & CW)  
  * Air Gun (AG)
1. Connection Type/Size- ¼” NPT
2. Pressure Range- 30 PSI MAX
3. Tip 1-5- Tip consumption at 30 PSI (Tip 4 and 5 must be operated at 30 PSI or less to comply with OSHA Directive.  
  * Basin Drain (BD)
1. Connection Type- 1-1/2” ABS P-TRAP (INCLUDED), 2” Copper P-Trap (Accessory)
2. Drain Rate At 20 GPM Each Basin (Estimated)  
  * Each Drain Individually Trapped
1. When Traps Are Not Required, Elbows Can Be Purchased Locally.
* Electricity- 120V, 15A GFCI Protected Outlet  
  * LINAK DL2 LIFT SYSTEM
1. Weight Capacity- 562LBS (2500 N) Each
2. Adjustment Range- 8.0” (203.2)
3. Lift Speed- Up To 3/8” (10) Per Second
4. Voltage- 120VAC, 3A With Overload Protection
* PHYSICAL SPECIFICATIONS
1. Shipping Dimensions- 132Lx 36Wx 48H
2. Shipping Weight- 580LBS
3. Operating Dimensions L x W x H- 97.5” x 28” x 44-9/16” TO 52-9/16” \[2477 x 711 x 1132 TO 1412\]
* Concrete Floor Must Remain Free of Defects in These Areas for Installation of Seismic Anchors (Not Provided by Steris).  
  * Refer to Equipment Specific Seismic Drawing for More Information.
* The Reprocessing Sinks must adhere to industry standards for AAMI/ ANSI, OSHA, etc.
* Documented FDA approval, as applicable.

3\. REQUIREMENTS

* The Contractor is responsible for conducting site visits to verify existing conditions, material quantities, installation instructions, and to identify any discrepancies or conflicting requirements within the Statements of Work before preparing the Final Proposal.
* The Contractor shall provide and install five AMSCO 50 Series Reprocessing Sinks to the VA Medical Center located at 4801 Linwood Kansas City, Mo 64128\.
* The Contractor must ensure that all repairs, preventative maintenance and remedial maintenance provided during this contract’s timeframe meet or exceed the OEM’S specifications.
* The contractor shall employ ONLY FULLY QUALIFIED TECHNICIANS/ENGINEERS for all work performed under this contract.
* The contractor shall ensure that only FULLY QUALIFIED TECHNICIANS/ENGINEERS are employed under this contract.
* The Contractor shall maintain the highest standard of professional capability and workmanship throughout the life of this contract.

4\. EQUIPMENT MAINTENANCE & RESPONSE TIMES

The vendor shall provide full-service maintenance through a service agreement for minimum 1 year post installation. The vendor shall provide all additional recurring and preventive maintenance activities:

1. Emergency response for equipment and MSPS failures. The vendor shall respond to the facility for any equipment failure resulting in a total or partial loss of the equipment installed within or any portion of the mobile sterile processing system within 4 hours from the time of VAMC contact. If a permanent solution cannot be resolved within 24 hours of initial failure, a temporary solution shall be operational within 24 hours of initial failure. An agreed permanent solution shall be planned, and replacements ordered within 5 business days of initial failure.

5\. SAFETY

The contractor/vendor shall always, ensure that all work provided complies with all local, State, and Federal rules and regulations pertaining to workplace safety. The contractor shall take all proper safety and health precautions to protect the work, the workers, the public and the property (OSHA). Installs and construction work will be in accordance with all applicable codes to include the most current codes National Fire Protection Association (NFPA), and the VA Design Guide Manuals that are applicable to the work. If the design guide is equivalent or more stringent then the mentioned codes, the VA Design Guide takes precedence.

6\. DOCUMENTATION

The contractor shall furnish to the KCVA Medical Center Biomedical Engineering department legible hard copies and electronic copies of service reports of the maintenance indicating details of the maintenance performed upon completion of all work.

7\. PLACE OF PERFORMANCE

Kansas City Veteran Administration Medical Center, 4801 Linwood Blvd. Kansas City 64128

8\. PERFORMANCE MONITORING

The contractor’s performance will be monitored by the Contracting Officer (CO), Contracting Officer Representative (COR), Infection Control Risk Assessment Office, and Safety Office during the rental agreement period.

Coordinate all administrative and construction requirements exclusively with or through assigned Contracting Officer Representative (COR).

The Construction Safety Officer, Construction Safety Committee, and COR will review the operations and site construction conditions of the project to confirm that all Safety regulations relating to construction and healthcare facilities are being adhered to. Daily and weekly safety rounds will be conducted. For non-compliance safety related issues, a safety report will be sent to the Contractor to correct within 14 days. Non-compliance may result in job-site suspense until compliance is met at the contractor’s expense.

9\. HOURS OF OPERATION

The contractor will perform services required during the hours of 7:30 am – 4:00 pm, Monday through Friday or as directed by the designated COR.

## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2ad72170f9f7465f948eb3b5d10a6dbc/download)

## Contacts

* Jon Lutmer

Email and phone are in the source notice.

[Source notice](https://sam.gov/workspace/contract/opp/dc8ba98fbd584a0496d02103810dfcc2/view)

```json
{"@context":"https://schema.org","@type":"Demand","name":"AMSCO 50 - series 3 - Bay Sink","description":"1. STATEMENT OF WORK The contractor shall furnish all necessary services, labor, travel, transportation, materials, shipping, parts, connections, and equipment. This includes the provision and on-site installation of at least 5 AMSCO 50 Series Reprocessing Sinks at 4801 Linwood Blvd, Kansas City MO 64128. These reprocessing sinks are required by the Sterile Processing Services (SPS) to facilitate the manual cleaning of sterilization-compatible reusable medical devices (RMD) in invasive procedures. Their use will support a range of medical procedures and surgeries, including those in the operating room, dental services, procedural gastroenterology, procedural pulmonology and surgical clinics. The contractor bears the responsibility for the removal and disposal of all debris and packaging materials resulting from the reprocessing sinks installation. Prior to equipment utilization, the contractor is required to provide training to clinical staff, with all duty tours for the sterile processing department being documented. The scope of this contract comprises five AMSCO 50 Series Reprocessing Sinks. Associated services include complete installation components, execution of a post-installation check-out test, and implementation of any necessary adjustments. 2. SPECIFICATIONS Minimum of five 3 Bay 97.5” x 28” x 33”- 41” Adjustable Height Reprocessing Sinks. Installer Must Maintain a Minimum Gap of .875” To All Adjacent Walls as a Pinch Point Protection. Unit Must Be Installed Against a Wall, For Back-to-Back Installation a Pony Wall is Required. 304 Stainless Steel Construction. Pony Wall Must Be 53” Wall Must Be Free of Obstructions to 54” Utility requirements (plumbing) Hot Water (HW) Connection Type/Size- 3/8” COMPRESSION Pressure Range- 15 to 125PSI Operating Flow Rate- 1.6GPM @ MAX PSI Temperature Range 40° to 180°F Water Quality- Steris recommends the following water quality parameters: 100-200 PPM (500PPM MAX) TOTAL DISOLVED SOLIDS. 71-120 PPM (180PPM MAX) TOTAL ALKALINITY. 6.8-7.0PH (7.5 MAX). 0.1-0.5PPM (1.0) TOTAL SILICA. Cold Water (CW) Connection Type/Size- 3/8” COMPRESSION Pressure Range- 15 to 125PSI Operating Flow Rate- 1.6GPM @ MAX PSI Temperature Range- 70° F MAX Water Quality- Steris Recommends The Following Water Quality Parameters: 100-200 PPM (500PPM MAX) TOTAL DISOLVED SOLIDS. 71-120 PPM (180PPM MAX) TOTAL ALKALINITY. 6.8-7.0PH (7.5 MAX). 0.1-0.5PPM (1.0) TOTAL SILICA PURE WATER (PW) Connection Type/Size- ½” NPT Pressure Range- 20 TO 125 PSI Operating Flow Rate- .25 TO 2.0 GPM 15% Temperature Range- 40° F to 140° F WATER GUN (WG) Connection type/size- 3/8” Compression Pressure Range- 0 TO 44 PSI Temperature Range- 40° TO 125° Water Quality- Recommendations listed under #5 of (HW \u0026 CW) Air Gun (AG) Connection Type/Size- ¼” NPT Pressure Range- 30 PSI MAX Tip 1-5- Tip consumption at 30 PSI (Tip 4 and 5 must be operated at 30 PSI or less to comply with OSHA Directive. Basin Drain (BD) Connection Type- 1-1/2” ABS P-TRAP (INCLUDED), 2” Copper P-Trap (Accessory) Drain Rate At 20 GPM Each Basin (Estimated) Each Drain Individually Trapped When Traps Are Not Required, Elbows Can Be Purchased Locally. Electricity- 120V, 15A GFCI Protected Outlet LINAK DL2 LIFT SYSTEM Weight Capacity- 562LBS (2500 N) Each Adjustment Range- 8.0” (203.2) Lift Speed- Up To 3/8” (10) Per Second Voltage- 120VAC, 3A With Overload Protection PHYSICAL SPECIFICATIONS Shipping Dimensions- 132Lx 36Wx 48H Shipping Weight- 580LBS Operating Dimensions L x W x H- 97.5” x 28” x 44-9/16” TO 52-9/16” [2477 x 711 x 1132 TO 1412] Concrete Floor Must Remain Free of Defects in These Areas for Installation of Seismic Anchors (Not Provided by Steris). Refer to Equipment Specific Seismic Drawing for More Information. The Reprocessing Sinks must adhere to industry standards for AAMI/ ANSI, OSHA, etc. Documented FDA approval, as applicable. 3. REQUIREMENTS The Contractor is responsible for conducting site visits to verify existing conditions, material quantities, installation instructions, and to identify any discrepancies or conflicting requirements within the Statements of Work before preparing the Final Proposal. The Contractor shall provide and install five AMSCO 50 Series Reprocessing Sinks to the VA Medical Center located at 4801 Linwood Kansas City, Mo 64128. The Contractor must ensure that all repairs, preventative maintenance and remedial maintenance provided during this contract’s timeframe meet or exceed the OEM’S specifications. The contractor shall employ ONLY FULLY QUALIFIED TECHNICIANS/ENGINEERS for all work performed under this contract. The contractor shall ensure that only FULLY QUALIFIED TECHNICIANS/ENGINEERS are employed under this contract. The Contractor shall maintain the highest standard of professional capability and workmanship throughout the life of this contract. 4. EQUIPMENT MAINTENANCE \u0026 RESPONSE TIMES The vendor shall provide full-service maintenance through a service agreement for minimum 1 year post...","url":"https://matchawards.com/department_of_veterans_affairs/posts/116716931627371795","identifier":"36C25526Q0442","category":"327110 - Pottery, Ceramics, and Plumbing Fixture Manufacturing","additionalProperty":[{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"4510 - PLUMBING FIXTURES AND ACCESSORIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.3 Facility Related Materials","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-materials"}],"availabilityStarts":"2026-06-08","availabilityEnds":"2026-06-17","areaServed":"Kansas City, Missouri 64128, UNITED STATES","sameAs":"https://sam.gov/workspace/contract/opp/dc8ba98fbd584a0496d02103810dfcc2/view"}
```

<!-- mobian-agent-ad sponsored="true" id="5902c487-2bc9-4f50-889f-39df0b9fcba7" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v3" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

| What | Where |
| :--- | :--- |
| Open federal and state contract opportunities | https://matchawards.com/contracts?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4 |
| Open federal contracts by Category Management category and PSC code | https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4 |
| Opportunities by state and city | https://matchawards.com/cities?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4 |
| Newest federal, grant and state opportunities | https://matchawards.com/explore_opportunities?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4 |

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->