<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/116699708725950297" -->

---
title: J012--Fire Sprinkler Repairs (36C26226Q0654) | Closed - MatchAwards
description: J012--Fire Sprinkler Repairs. United States Department of Veterans Affairs. Solicitation 36C26226Q0654. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. SDVOSB set-aside. Deadline 2026-06-19. Page 1 of 14 Page 12 of 12 Page 1 of 14 STATEMENT OF WORK CONTRACT TITLE: Fire...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/116699708725950297
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J012--Fire Sprinkler Repairs (36C26226Q0654) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/116699708725950297
og:description: J012--Fire Sprinkler Repairs. United States Department of Veterans Affairs. Solicitation 36C26226Q0654. NAICS 238220 - Plumbing, Heating, and Air-Conditioning Contractors. SDVOSB set-aside. Deadline 2026-06-19. Page 1 of 14 Page 12 of 12 Page 1 of 14 STATEMENT OF WORK CONTRACT TITLE: Fire...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J012--Fire Sprinkler Repairs

Status

Closed, the response deadline passed on Jun 19, 2026

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

Gilbert, USA

Notice type

Sources Sought

Solicitation number

36C26226Q0654

NAICS

[238220 - Plumbing, Heating, and Air-Conditioning Contractors](/groups/228)

PSC

J012 - MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2026-06-05

Deadline

2026-06-19

Place of performance

Tucson, AZ 85723

## Description

Page 1 of 14 Page 12 of 12 Page 1 of 14 STATEMENT OF WORK CONTRACT TITLE: Fire Sprinkler repairs PLACE OF PERFORMANCES: VA San Diego Healthcare System 3350 La Jolla Village Dr. San Diego, CA 92161 PERIOD OF PERFORMANCE: 07/01/2026-06/30/2027 CONTRACT TYPE: Firm Fixed Price BACKGROUND: Fire sprinkler deficiencies from 2025 annual inspection and testing. GENERAL REQUIREMENTS: Per applicable VA San Diego requirements/standards, the contractor will: BLDG 1 WETPIPE REQUIRED REPAIRS: \*\*\*\* 6TH FLOOR \*\*\*\* NORTH: The following areas were found to have 50yr old sprinklers: 6231 (2), 6232 (2), 6233A (2), 6242 (2), 6239 (2), 6240, 6233 (2), 6243 (2), 6254 (6), 6245 (2), 6246 (4), 6246A (2), 6230 (4), 6252B (2), 6252C (1), 6252E (4), 6247 (2), 6249 (2), 6250 (1), 6251 (1), 6254 (6), 6254A (2), 6256 (2), 6257 (2), 6264 (1), 6254B (2), 6263 (2), 6267 (6), 6268 (1), 6269 (2), 6259 (2),6263A (1), 6224 (1), 6225 (1), 6219 (2), 6218 (2), 6217 (4), 6215 (1), 6268 (2). Replace (88) 165Â° STD Â½ Chrome SSP 401chrome trim. WEST: The following areas were found to have 50yr old sprinklers: 6097 (1), 6024 (1), 6035 (4), 6025 (2), 6032 (2), 6030(4), 6070 (1), 6029 (2), 6083 (2), 6082 (2), 6050 (1), 6045 (2), 6080 (1), 6081 (14), 6062 (3), 6048 (2), 6051 (2), 6049 (2), 6052(5), 6055 (3), 6058 (2), 6061 (2), 6056A (2), 6069 (2), 6074 (2), 6086 (2), 6087 (2), 6088 (4), 6095 (2), 6096 (2), 6091 (1), 6091A(1). Replace (82) 165Â° STD Â½ chrome SSP 401 chrome trim. SOUTH: The following areas were found to have 50yr old sprinklers: 6105 (3), 6107 (4), 6110 (4) 6118 (2), 6112 (1). Replace(14) 165Â° STD Â½ chrome SSP 401 chrome trim. EAST: The following areas were found to have 50yr old sprinklers: 6149 (1), 6150 (4), 6153 (2), 6160 (1), 6163 (2), 6164 (4),6169 (2), 6170 (2), 6171 (2), 6172 (2), 6176 (2), 6174C (3), 6174G (4), 6174F (4), 6184 (2), 6189A (3), 6189C (2), 6187 (1), 6190(1), 6191 (2), 6192 (2), 6197 (1), 6198 (2) , 6200 (3), 6202 (2), 6203 (2), 6204 (2), 6205 (2), 6207 (2). Replace (66) 165Â° STD Â½ chrome SSP 401 chrome trim. CORE: Housekeeping closet 6010 replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim. NORTH: 6254B replace (2) 20yr old 155Â° QR Â½ chrome SSP 399 chrome trim (2001). NORTH: 6252A next to cage washer door replace (1) corroded 200Â° QR Â½ chrome SSP 401 Chrome trim. NORTH: 6268 replace (2) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim (2001). WEST: refrigerator 6037 replace (2) 20yr old 200Â° QR 1 x 12 chrome dry pendant w/ chrome trim (2002). NOTE: This will require majority stitch work. WEST: 6028 replace (2) loaded/corroded 155Â° QR Â½ chrome SSP 401 chrome trim. WEST: 6044A in 6043 replace (1) corroded 155Â° QR Â½ white SSP SRW. WEST: 6044 entry replace (1) corroded 155Â° QR Â½ white SSP SRW. WEST: 6040 women s bathroom shower replace (1) corroded 155Â° STD Â½ chrome SSP 401 chrome. WEST: refrigerator 6081E replace (1) 10yr old 200Â° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6070 refrigerator replace (1) 10yr old 200Â° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6056A & 6057 replace (2) 20yr old 155Â° QR Â½ chrome SSP SRC trim (2001). WEST: 6062 replace (3) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim (2002). WEST: 6070 replace (1) 20yr old 155Â° QR Â½ white SSP SRW trim (2004). WEST: 6091 & 6091A replace (2) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim (2002). SOUTH: 6104 refrigerator replace (1) 10yr old 200Â° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. SOUTH: 6108A replace (4) corroded 165Â° STD Â½ chrome SSP 401 chrome trim. SOUTH: 6112 replace (1) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim (2005). SOUTH: 6112 refrigerator replace (1) 10yr old 200Â° STD 1 x 12 chrome dry pendant w/ chrome trim (2013) this will require majority stitch work. NOTE: Inside refrigerator is very warm! EAST: hallway leading to stair 12 replace (9) corroded 155Â° STD Â½ white SSP 401 white trim. EAST: 6155 replace (2) corroded 165Â° STD Â½ chrome SSP 401 chrome trim. EAST: refrigerator 6166 replace (2) 10yr old 200Â° QR 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. EAST: 6179 replace (2) corroded 165Â° STD Â½ chrome SSP 401 chrome trim EAST: 6197A in 6198 replace (3) corroded 165Â° STD Â½ chrome SSP 401 chrome trim \*\*\*\* 5TH FLOOR \*\*\*\* SOUTH: exterior core hallway from stair 11 to dead end into east wing replace (7) corroded 155Â° QR Â½ White SSP 401 white trim. NORTH: exterior core hallway to stair 9 replace (5) corroded 155Â° QR Â½ white SSP 401 white. These Sprinklers are also near 20yrs old (2008). NORTH: hallway outside 5315 replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim. WEST: 5004 next to 5003 men s bathroom replace (2) corroded 155Â° QR Â½ chrome SSP 401 chrome Trim. CORE: hallway to south wing door replace (4) 20yr old 155Â° QR Â½ chrome SSP SRC trim. CORE: 5019 replace (1) 20yr old 155Â° QR Â½ chrome SSP SRC trim. CORE: 5020 replace (9) 20yr old 155Â° QR Â½ chrome SSP SRC trim. CORE: 5006 (2), 5005 (2), 5021 (1), 5010 (1), women s restroom (2), 5008 (6). Replace (14) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. NORTH: 5280 replace (6) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. NORTH: 5284 area and hallways replace (20) 20yr old 155Â° QR Â½ chrome SSP SRC trim. NORTH: 5341 replace (1) 20yr old 155Â° QR Â½ chrome HSW 401 chrome trim. NORTH: Vascular Lab area and hallways replace (61) 20yr old 155Â° QR Â½ chrome SSP SRC trim. NORTH: ASU area replace (72) 20yr old 155Â° QR Â½ chrome SSP SRC trim & (7) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. EAST: east wing hallway and rooms replace (36) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. EAST: C Pod replace (22) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim . EAST: B Pod replace (18) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. EAST: B Pod in room 5219 replace (2) 20yr old 155Â° QR Â½ chrome HSW 401 chrome trim. SOUTH: 5106B (1), 5126 (1), 5106A (1). Replace (3) 20yr old 155Â° QR Â½ chrome SSP 401 chrome Trim. SOUTH: 5104 replace (4) 20yr old 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 5140 replace (4) 20yr old 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 5105 replace (2) 20yr old 155Â° QR Â½ chrome SSP SRC trim. SOUTH: hallway from nurse station C to room 7 replace (40) 20yr old 155Â° QR Â½ chrome SSP SRC trim. SOUTH: entrance to reception desk replace (7) 20yr old 155Â° QR Â½ chrome SSP SRC trim. SOUTH: Nurses station A replace (18) 20yr old 155Â° QR Â½ chrome SSP SRC trim. SOUTH: DOU area & patient rooms (31), staff office area (33). Replace (64) 20yr old 155Â° QR Â½ chrome SSP SRC trim. EAST: 5244 bathroom replace (1) corroded 155Â° QR Â½ chrome SSP 401 chrome trim. EAST: 5229 house keeping replace (1) missing Victaulic SRC trim. WEST: throughout Anesthesia/Surgery replace (128) 20yr old 155Â° QR Â½ chrome SSP 401 chrome Trim & (56) 20yr old 155Â° QR Â½ chrome SSP SRC trim. NOTE: Work to be completed at night. \*\*\*\* 4TH FLOOR \*\*\*\* SOUTH: 4329 replace (1) painted 155Â° QR Â½ chrome SSP 401 chrome trim SOUTH: 4004 women s bathroom replace (1) corroded 155Â° QR Â½ chrome SSP 401 chrome trim SOUTH: 4108 room #7 replace (3) corroded 155Â° QR Â½ chrome SSP (1) SRC trim & (2) 401 chrome Trim NORTH: 4284 in 4289 exam room replace (1) corroded 155Â° QR Â½ chrome SSP 401 chrome Trim NORTH: 4026 EP holding room replace (1) corroded 155Â° QR Â½ white SSP SRW trim WEST: 4040 Specialty a clinic in 4045 clean linen replace (1) Victaulic SRC trim WEST: in 4071 Nuclear Medicine Hallway outside staff bathroom 4054 replace (1) corroded 155Â° QR Â½ chrome SSP 401 chrome trim EAST: 4184B there are (2) sprinkler under 6 of each other in a cold solder situation. Need to relocate One sprinkler. SOUTH: 4124 room #16 replace (4) corroded 155Â° QR Â½ chrome SSP (1) SRC trim & (3) 401 Chrome trim. SOUTH: 4113 room #12 replace (3) corroded 155Â° QR Â½ chrome SSP (1) SRC trim & (2) 401 chrome Trim. SOUTH: 4115 meditation room replace (2) corroded 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 4162 conference room replace (2) corroded 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 4122 room #14 replace (2) corroded 155Â° QR Â½ chrome SSP (1) SRC trim & (1) 401 chrome Trim. SOUTH: 4123 room #15 replace (4) corroded 155Â° QR Â½ chrome SSP (1) SRC trim & (3) 401 Chrome trim. SOUTH: hallway outside 4123 & 4124 replace (2) corroded 155Â° QR Â½ chrome SSP SRC trim. CORE: 4000A (2), 4008 (7), 4006 (2), 4005 (1). replace (12) 20yr old 155Â° QR Â½ chrome SSP 401 Chrome trim. CORE: 4016 replace (5) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. CORE: 4015 (9), 4015A (2) replace (11) 20yr old 155Â° QR Â½ chrome SSP SRC trim. NORTH: 4366 (11), 4370 (1), 4303 (2), 4304 (5), main hallway (13), Exam rooms 12-21 & hall Way (32), exam rooms 1-11 & hallway (34). replace (98) 20yr old 155Â° QR Â½ chrome SSP 401 chrome SSP 401 chrome trim. EAST: 4263 surgical service Annex replace (39) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. EAST: 4186 nursing service replace (34) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. EAST: ELT area replace (75) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim & (5) SRC. EAST: hallway & rooms off hallway replace (30) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. WEST: 4071 (32), 4044A (1), 4044 (2), 4043 (1), 4079 (1), 4086A (1), hallway (2), 4075 (4), 4076 (12), 4085 (5), 4022 (23).Replace (84) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. SOUTH: 4125 room #17 replace (2) corroded 155Â° QR Â½ chrome 401 chrome trim. SOUTH: hallway outside 4126 replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 4139 room #23 replace (4) corroded 155Â° QR Â½ chrome SSP (1) SRC trim & (3) 401 Chrome trim. SOUTH: 4134 room #27 replace (2) corroded 155Â° QR Â½ chrome SSP 401 chrome trim. SOUTH: hallway outside 4137 replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 4175D bathroom replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 4175 right hand closet replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim. SOUTH: hallway outside 4175 replace (2) corroded 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 4156 Ante room - 4157 room #30 bathroom replace (1) corroded 155Â° QR Â½ chrome SSP 401 chrome trim. \*\*\*\* 3RD FLOOR \*\*\*\* CORE / NORTH: 3308C replace (1) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. CORE: 3018 (9), 3002 (2), 3004 (6), 3008 (7), 3007 (1). Replace (25) 20yr old 155Â° QR Â½ chrome SSP 401 chrome Trim. NORTH: The following areas were found to have 20yr old sprinklers: 3317 (1), hallway from 3317 to 3310 (7), 3318 (1),3322 (5), 3324 (1), 3316 (2), 3325 (3), 3314 (4), 3327 (3), 3317A (2), 3313 (1), 3310 (1), hallway from north wing entry to 3337(6), 3383 (1), 3382 (1), 3380 (2), Dayroom (3), 3334 (1), 3333 (1), 3379, (1), 3378 (1), 3336 (1), 3377 (1), 3357 (4), 3357B (1), hallway from 3372 To 3342 (9), 3339 (1), 3356 (1), 3354 (6), 3340 (3), 3353A (1), 3342 (3), hallway from 3345 to 3349 (3), 3345(5), 3347 (3), 3349 (3), 3352 (1), 3359 (3), 3360 (5), 3374 (3), 3372 (3), 3371 (1), 3369 (3), hallway from 3369 to 3363 (3), 3363A(1), 3363 (1), 3402 (1), hallway outside 3402 (2), 3386 (2) 3388 (3), hallway from 3399 to 3395 (6), D Pod staff bathroom (1), bathroom outside 3391 (1), 3393 (3), 3395 (3), 3397A (1), 3397 (1). Replace (150) 155Â° QR Â½ chrome SSP 401 chrome Trim. EAST: The following areas were found to have 20yr old sprinklers: hallway from 3217 to 3225 (4), 3219 (3), 3217 (1), 3217A , 3221 (4), 3223 (4), 3225 (1), 3227 (3), 3226 (1), 3213 (1). Replace (23) 20yr old 155Â° QR Â½ chrome SSP SRC trim. SOUTH: The following areas were found to have 20yr old sprinklers: 3207A (2), South entry to 3162 (8), 3207B (2), 3161, 3168 (2), 3170 (2), 3172 (1), hallway from 3170 to 3162 (6), 3176 (1), 3175 (1), 3174B (1), 3174 (1), 3167 (1), 3177 (1), 3162G (4), 3164 (2), 3185 (2), 3186B (1), 3186A (2), 3187 (1), 3188 (1), 3190 (1), 3206 (1), 3191 (1), 3192 (2), 3207 (1), hallway from 3206 to 3202 (5), 3193 (2), 3203 (1), 3195 (1), 3196 (4), 3200 (3), 3202 (1), 3202A (1). Replace (70) 20yr old 155Â° QR Â½ chrome SSP 401 Chrome Trim. SOUTH: The following areas were found to have 20yr old sprinklers: 3117 (6), 3121 (1), 3120 (1), 3125 (1), 3 south special procedures area entry to To 3138 (36), outside 3150 (1), 3161 (1), 3139 (1) 3142 (5), 3140 (4), 3143 (2), 3144 (1), 3146 (1), 3148B (2), 3147 (1), 3162 (9). Replace (73) 20yr old 155Â° QR Â½ chrome SSP SRC trim. SOUTH: 3126 & 3129 replace (2) 20yr old 155Â° QR Â½ chrome HSW SRC trim. EAST: The following areas were found to have 20yr old sprinklers: east wing entry to 3211 (4), 3209 (4), 3210 (2), 3211 (2),3307 (1), 3306 (4), 3213 (1), hallway from 3227 to 3300 (3), hallway From 3260 to 3257 (5), 3260 (1), 3258 (1), 3234 (1), 3257 (2), 3236 (1), 3251 (6), 3237 (2), Hallway from 3236 to 3249A (7), 3246 (3), 3249A (1), 3249 (1), 3246A (1), 3246 (3), 3244 (3), 3242 (5), 3240 (3), 3273C (3), 3253 (2), 3256 (1), hallway from 3256 to 3276A (7), 3275A (1), 3275 (2), hallway from 3285 to 3263 (6), 3262A (1), 3262A (1), 3264 (1), 3263 (1), 3266 (2), 3287 (2), 3267 (2), 3286A (2), 3267A (1), 3285 (1), 3268 (4), 3270 (2), 3272 (1), 3271 (1), 3274 (1), 3284 (1), 3283 (1), 3281 (2), 3280A (1), 3282 (3), 3276B (1), 3280 (1), 3276A (1), 3276 (1), 3279 (1) Replace (125) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. EAST: 3214 replace (1) missing Viking VK4621 white concealed cover plate. EAST: hallway outside 3249A replace (1) 20yr old 155Â° QR Â½ chrome HSW 401 chrome trim. \*\*\*\* 2ND FLOOR \*\*\*\* EAST: The following areas were found to have 20yr old sprinklers: 2244A (1), 2356A (1), 2356 (1), Hallway from 2243 to 2354 (4), 2356A (2), 2356 (2), 2355 (2), 2354 (2), hallway from 2254A to 2339 (17), 2349 (2), 2346 (2), 2348 (2), 2345 (2), 2343(2), 2247 (1), 2248 (1), 2249 (1), 2252 (1), 2253 (1), 2254 (1), 2254A (2), 2254B (1), 2256 (3), 2260 (5), 2262 (1), 2263 (1), 2264(5), 2270 (1) 2274 (1), 2275 (1), 2278 (5), 2280 (5), 2282 (1), 2284 (1), 2286 (1), 2289 (1), 2290 (1), 2291 (1), 2292 (6), 2296 (2),2296A (2), 2296B (1), 2297C (3), 2297A (1), 2298 (1), 2299 (1), 2300 (1), 2302 (1), 2303 (1), 2304 (1), 2305A (1), 2305 (1), 2305B(2), 2306 (5), 2308 (1), 2309 (1), 2310 (7), 2312 (1), 2313 (1), 2314 (1), 2316 (3), 2318 (3), 2320 (3), 2322 (6), 2324 (5), 2326 (1),2327 (1), 2328 (2), 2331 (1), 2332 (1), 2336 (6), 2339 (2), 2341 (5), 2343 (1), 2345 (1), 2346 (1), 2348 (1), 2350 (1), 2351 (5),2353 (1), hallway from 2302 to 2314 (9), hallway from 2269 to 2290 (10). Replace (178) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. NORTH: in 2452 (2) sprinklers are 2 apart causing a cold solder situation, need to plug off (2). In 2452A (2) sprinklers are 4 apart causing a cold solder situation, need to plug off (1). NORTH: 2469 (1), 2358 (1), 2468 (1), 2359 (1), 2360 (1), 2466 (1), 2361 (1), 2362 (1), 2366 (4), 2367 (1), 2368 (1), 2369 (3), 2372 (1), 2374 (1), 2374B (2), 2376 (3), 2379 (6), 2382 (1), 2387 (2), 2388 (1), 2389 (1), 2393 (4), 2394 (4), 2397 (2), 2398 (1),2401 (2), 2404 (1), 2406 (6), 2408 (1), 2410 (6), 2410D (1), 2410E (1), 2416A (4), 2413A (1), 2413 (1), 2417 (3), 2418 (1), 2425(1), 2429 (1), 2433 (1), 2436 (5), 2338 (5), 2439 (1), 2440 (1), 2441 (1), 2442 (1), lobby linen closet (1) 2454 (3), 2452 (3), 2455(5), 2457 (2), 2460 (2), 2461 (1), 2462 (1), 2449 (1), 2463 (5), 2465 (1), 2445 (1) SRC, all hallways (43). Replace (140) 20yr old155Â° QR Â½ chrome SSP 401 chrome trim. WEST: 2017 (1), 2018 (2), 2129 (1), 2128 (1), 2127 (1), 2021 (1), 2025 (1), 2026 (1), 2028 (2), 2032 (3), 2034 (1), 2035 (1),2036 (4). Replace (20) 20yr old 155Â° QR Â½ chrome SSP 401 chrome Trim. WEST: hallway from 2019 to 2017 replace (4) 20yr old 155Â° QR Â½ chrome SSP SRC trim. WEST: 2056 replace (1) missing Tyco SRW trim. CORE: 2013 (1), 2014 (1), 2002 (10), 2012 (2), 2011 (7). Replace (21) 20yr old 155Â° QR Â½ chrome SSP SSP 401 chrome trim. \*\*\*\* 1ST FLOOR \*\*\*\* 1.2/ INTERSTITIAL SPACE: Northeast system the 3 OS&Y is leaking at the flanges, recommend demoing And replacing with a 3 Butterfly valve w/ tamper. Will need (1) 3 x 2 -0 GxP filler piece of pipe, cut to fit on-site. Also need (3) 3 flex grooved couplings. Everon to wire new tamper. 1505: VA Police monitor room replace (2) 20yr old 155Â° QR Â½ chrome SSP SRC trim (2002) 1597: replace (1) missing Tyco SRC trim. 1465: in exam room 1474 replace (1) 20yr old 155Â° QR Â½ chrome SSP SRC trim (2002). 1487: PMRS storage sprinkler needs to be lowered (1) 155Â° STD Â½ chrome SSP SRC trim. \*\*\*\* BASEMENT \*\*\*\* B135A (1), hallway from B135 to B156A (19), B156 (20), hallway from B118 to B115A (6). Replace (46) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim. B125B: food services there was 20yr old QR sprinklers found, replace (76) 155Â° QR Â½ White SSP 401 white trim (Any Central or Grinnell model sprinkler). B125B: food services in refrigerators B136 (1), B137 (2), B138 (2) & freezer B181 (2) Replace (7) 10yr old 200Â° QR 1 x 12 chrome dry pendant w/ chrome trim. (2020). NOTE: this will require majority stitch work. B121 (10), B126 (4), B115A (1), replace (15) 20yr old 155Â° QR Â½ White SSP 401 white trim. B125B: Women s bathroom replace (1) corroded 155Â° QR Â½ white SSP 401 white trim B114A replace (3) 50yr old 165 STD Â½ Chrome SSP 401 chrome trim. B251: manifold room on system 12 riser (Shop) replace (1) corroded angled main drain Valve And Nipple. Material needed: (1) 2 x 0-2 TxT nipple and 2 x close TxT nipple, (1) 2 elbow, (1) 2 x 0-4 TxT nipple & (1) 2 angled main drain valve. There is a 2 union down stream where Work can Start to back out piping. Hallway from door B102 to door B101 replace (5) corroded 155Â° QR Â½ chrome SSP SRC trim NOTE: these sprinklers could be crossed from building 11, recommend impairment/shut Down Request be for both buildings 1 & 11\. The following areas were found to have 20yr old sprinklers: hallway from Stair 6 to B200 (10), B213 (12), B217 (15), B217A(4). Replace (41) 155Â° QR Â½ chrome SSP 401 chrome trim. The following areas were found to have 20yr old sprinklers: B206 (2), B205 (3), hallway from B247 To B231 (14), service Elevator lobby to SW-13 (10), elevator lobby to B155 (16), B162 (2), B159B (2). Replace (49) 155Â° QR Â½ chrome SSP SRC trim. The following areas were found to have 50yr old sprinklers: B233 (9), B232 (9), B216C (1), B223 (25), B238 (25), B233 (15),B114 (1). B230 (2). Replace (87) 165Â° STD Â½ chrome SSP 401 chrome. The following areas were found to have 50yr old sprinklers: Above roll up door over pump house 165Â° STD Â½ chrome (4) SSU & (1) SSP no trims. One man Genie lift needed. HTM OPS: mezzanine & open area replace (29) 20yr old 155Â° QR Â½ brass SSU no trim Single man genie lift needed for open area. hallway from B102 to B223C replace (5) corroded 155Â° QR Â½ chrome SSP SEC trim. B238: refrigerator B235 replace (2) 20yr old 200Â° STD 1 x 12 chrome dry pendant w/ Chrome trim. NOTE: this will require majority stitch work. BLDG 1 STANDPIPE REQUIRED REPAIRS: Elevator machine room on roof 1 1/2 hose valve replace (1) missing 1 1/2 brass threaded cap. Elevator machine room roof - 50% of the (9) 1 1/2 hose valves on the roof have handles and stems that are starting to corroded. Will need to replace if condition worsens. Station 22: replace (1) broken 1 Â½ angled STD Powhatan hose valve. BLDG 2 WETPIPE REQUIRED REPAIRS: 1st flr: Decon / shower 101B & storage closet replace (1) corroded 155Â° QR Â½ chrome SSP SRC. 2nd flr: in room 204 pipe & fittings area replace (3) corroded and 20yr old 155Â° QR Â½ brass SSP W/ red head guards. BLDG 11: REQUIRED REPAIRS: Basement: just inside door B106 replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim Basement: BB103C 

<!-- mobian-agent-ad sponsored="true" id="0c2a317a-0579-488c-93aa-1b9678d59112" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/204563fb6c4f452ba69e9265f7dfae74/download)

## Contacts

* Diana McInnis, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/workspace/contract/opp/80877120a98e4da28fe10fbc86adff2c/view)

[More from United States Department of Veterans Affairs posted in June 2026](/department%5Fof%5Fveterans%5Faffairs/archive/2026-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J012--Fire Sprinkler Repairs","description":"Page 1 of 14 Page 12 of 12 Page 1 of 14 STATEMENT OF WORK CONTRACT TITLE: Fire Sprinkler repairs PLACE OF PERFORMANCES: VA San Diego Healthcare System 3350 La Jolla Village Dr. San Diego, CA 92161 PERIOD OF PERFORMANCE: 07/01/2026-06/30/2027 CONTRACT TYPE: Firm Fixed Price BACKGROUND: Fire sprinkler deficiencies from 2025 annual inspection and testing. GENERAL REQUIREMENTS: Per applicable VA San Diego requirements/standards, the contractor will: BLDG 1 WETPIPE REQUIRED REPAIRS: **** 6TH FLOOR **** NORTH: The following areas were found to have 50yr old sprinklers: 6231 (2), 6232 (2), 6233A (2), 6242 (2), 6239 (2), 6240, 6233 (2), 6243 (2), 6254 (6), 6245 (2), 6246 (4), 6246A (2), 6230 (4), 6252B (2), 6252C (1), 6252E (4), 6247 (2), 6249 (2), 6250 (1), 6251 (1), 6254 (6), 6254A (2), 6256 (2), 6257 (2), 6264 (1), 6254B (2), 6263 (2), 6267 (6), 6268 (1), 6269 (2), 6259 (2),6263A (1), 6224 (1), 6225 (1), 6219 (2), 6218 (2), 6217 (4), 6215 (1), 6268 (2). Replace (88) 165Â° STD Â½ Chrome SSP 401chrome trim. WEST: The following areas were found to have 50yr old sprinklers: 6097 (1), 6024 (1), 6035 (4), 6025 (2), 6032 (2), 6030(4), 6070 (1), 6029 (2), 6083 (2), 6082 (2), 6050 (1), 6045 (2), 6080 (1), 6081 (14), 6062 (3), 6048 (2), 6051 (2), 6049 (2), 6052(5), 6055 (3), 6058 (2), 6061 (2), 6056A (2), 6069 (2), 6074 (2), 6086 (2), 6087 (2), 6088 (4), 6095 (2), 6096 (2), 6091 (1), 6091A(1). Replace (82) 165Â° STD Â½ chrome SSP 401 chrome trim. SOUTH: The following areas were found to have 50yr old sprinklers: 6105 (3), 6107 (4), 6110 (4) 6118 (2), 6112 (1). Replace(14) 165Â° STD Â½ chrome SSP 401 chrome trim. EAST: The following areas were found to have 50yr old sprinklers: 6149 (1), 6150 (4), 6153 (2), 6160 (1), 6163 (2), 6164 (4),6169 (2), 6170 (2), 6171 (2), 6172 (2), 6176 (2), 6174C (3), 6174G (4), 6174F (4), 6184 (2), 6189A (3), 6189C (2), 6187 (1), 6190(1), 6191 (2), 6192 (2), 6197 (1), 6198 (2) , 6200 (3), 6202 (2), 6203 (2), 6204 (2), 6205 (2), 6207 (2). Replace (66) 165Â° STD Â½ chrome SSP 401 chrome trim. CORE: Housekeeping closet 6010 replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim. NORTH: 6254B replace (2) 20yr old 155Â° QR Â½ chrome SSP 399 chrome trim (2001). NORTH: 6252A next to cage washer door replace (1) corroded 200Â° QR Â½ chrome SSP 401 Chrome trim. NORTH: 6268 replace (2) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim (2001). WEST: refrigerator 6037 replace (2) 20yr old 200Â° QR 1 x 12 chrome dry pendant w/ chrome trim (2002). NOTE: This will require majority stitch work. WEST: 6028 replace (2) loaded/corroded 155Â° QR Â½ chrome SSP 401 chrome trim. WEST: 6044A in 6043 replace (1) corroded 155Â° QR Â½ white SSP SRW. WEST: 6044 entry replace (1) corroded 155Â° QR Â½ white SSP SRW. WEST: 6040 women s bathroom shower replace (1) corroded 155Â° STD Â½ chrome SSP 401 chrome. WEST: refrigerator 6081E replace (1) 10yr old 200Â° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6070 refrigerator replace (1) 10yr old 200Â° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. WEST: 6056A \u0026 6057 replace (2) 20yr old 155Â° QR Â½ chrome SSP SRC trim (2001). WEST: 6062 replace (3) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim (2002). WEST: 6070 replace (1) 20yr old 155Â° QR Â½ white SSP SRW trim (2004). WEST: 6091 \u0026 6091A replace (2) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim (2002). SOUTH: 6104 refrigerator replace (1) 10yr old 200Â° STD 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. SOUTH: 6108A replace (4) corroded 165Â° STD Â½ chrome SSP 401 chrome trim. SOUTH: 6112 replace (1) 20yr old 155Â° QR Â½ chrome SSP 401 chrome trim (2005). SOUTH: 6112 refrigerator replace (1) 10yr old 200Â° STD 1 x 12 chrome dry pendant w/ chrome trim (2013) this will require majority stitch work. NOTE: Inside refrigerator is very warm! EAST: hallway leading to stair 12 replace (9) corroded 155Â° STD Â½ white SSP 401 white trim. EAST: 6155 replace (2) corroded 165Â° STD Â½ chrome SSP 401 chrome trim. EAST: refrigerator 6166 replace (2) 10yr old 200Â° QR 1 x 12 chrome dry pendant w/ chrome trim (2013). NOTE: this will require majority stitch work. EAST: 6179 replace (2) corroded 165Â° STD Â½ chrome SSP 401 chrome trim EAST: 6197A in 6198 replace (3) corroded 165Â° STD Â½ chrome SSP 401 chrome trim **** 5TH FLOOR **** SOUTH: exterior core hallway from stair 11 to dead end into east wing replace (7) corroded 155Â° QR Â½ White SSP 401 white trim. NORTH: exterior core hallway to stair 9 replace (5) corroded 155Â° QR Â½ white SSP 401 white. These Sprinklers are also near 20yrs old (2008). NORTH: hallway outside 5315 replace (1) corroded 155Â° QR Â½ chrome SSP SRC trim. WEST: 5004 next to 5003 men s bathroom replace (2) corroded 155Â° QR Â½ chrome SSP 401 chrome Trim. CORE: hallway to south wing door replace (4) 20yr old 155Â° QR Â½ chrome SSP SRC trim. CORE: 5019 replace (1)...","url":"https://matchawards.com/department_of_veterans_affairs/posts/116699708725950297","identifier":"36C26226Q0654","category":"238220 - Plumbing, Heating, and Air-Conditioning Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J012 - MAINT/REPAIR/REBUILD OF EQUIPMENT- FIRE CONTROL EQUIPMENT"}],"availabilityStarts":"2026-06-05","availabilityEnds":"2026-06-19","validThrough":"2026-06-19T23:59:59-04:00","areaServed":"Tucson, AZ 85723","sameAs":"https://sam.gov/workspace/contract/opp/80877120a98e4da28fe10fbc86adff2c/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```