<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/116200482471858745" -->

---
title: J049--Sources Sought Notice Need a contractor for Generator… | Closed - MatchAwards
description: J049--Sources Sought Notice  Need a contractor for Generator Testing Services  Louis A Johnson VA Medical Center  36C24526Q0352. United States Department of Veterans Affairs. Solicitation 36C24526Q0352. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/116200482471858745
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J049--Sources Sought Notice Need a contractor for Generator… | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/116200482471858745
og:description: J049--Sources Sought Notice  Need a contractor for Generator Testing Services  Louis A Johnson VA Medical Center  36C24526Q0352. United States Department of Veterans Affairs. Solicitation 36C24526Q0352. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J049--Sources Sought Notice Need a contractor for Generator Testing Services Louis A Johnson VA Medical Center 36C24526Q0352

Status

Closed, the response deadline passed on Mar 20, 2026

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LINTHICUM, USA

Notice type

Sources Sought

Solicitation number

36C24526Q0352

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

J049 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MAINTENANCE AND REPAIR SHOP EQUIPMENT

Category

[Industrial Products Install / Maintenance / Repair (5.5)](/categories/industrial-products-and-services/industrial-products-install-maintenance-repair)

Posted

2026-03-09

Deadline

2026-03-20

Place of performance

Clarksburg, West Virginia 26301, UNITED STATES

## Description

Summary: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor to provide Generator Testing Services for the Louis A Johnson VA Medical Center. Review last page for details on how to respond to this Sources Sought notice. Scope of work: Location of work: Louis A Johnson VA Medical Center 1 Medical Ctr Dr, Clarksburg, WV 26301 Base plus Four (4) Option Year contract. This ensures the Louis A. Johnson VAMC maintains continuous compliance with the most recent VHA-adopted NFPA 110 and is fully prepared for The Joint Commission (TJC) and OIG inspections. 1.0 Contract Structure Base Year: \[Dates\] Option Years 1-4: To be exercised annually. Emergency Coverage: 24/7/365 On-call availability. 2.0 Scope of Work The contractor shall provide all labor, materials, and equipment to perform monthly, annual, and triennial testing, as well as emergency repair services. Monthly Operational Test Duration: Minimum 30 continuous minutes under facility load. Time-to-Transfer: Must reach operating voltage/frequency and transfer load within 10 seconds. ATS Rotation: Contractor shall rotate the initiating Automatic Transfer Switch (ATS) monthly to ensure all switches are cycled annually. Supplemental Load Bank Testing (As Required) In accordance with the most recent NFPA 110, Section 8.4.2, if a generator fails to reach the required 30% of the nameplate kW rating or the manufacturer s recommended exhaust gas temperature during the monthly run: Requirement: The contractor shall provide a portable load bank. Procedure: The unit shall be exercised for 2 hours annually at a load increasing to at least 75% of the nameplate rating. Triennial (36-Month) 4-Hour Run Once every 36 months, the contractor shall conduct a continuous 4-hour load test: First 3 Hours: Minimum 30% of nameplate kW. Final Hour: Minimum 75% of nameplate kW (utilizing a load bank if facility load is insufficient). 3.0 Emergency Response & Repair Response Time: The contractor shall provide emergency repair services with a maximum 2-hour on-site response time from the initial call by the M&O Supervisor or Engineering Staff. Availability: This requirement applies 24 hours a day, 7 days a week, including holidays. Reporting: Any emergency repair must result in a "Return to Service" report documenting the FboNotice cause and the speci c NFPA 110 re-test performed to verify system readiness. 4.0 TJC & OIG Documentation Standards All reports must be "Audit-Ready" and submitted to the Facilities Management Service (FMS) within 72 hours. Speci c Data: Reports must include exact kW/Amperage, Hz, and exhaust temperatures. Battery Diagnostics: Conductance or speci c gravity readings are mandatory for each battery cell/unit. Certi cation: A signed attestation that the test met the most recent VHA/NFPA 110 performance criteria. 5.0 Contractor Quali cations & Safety Certi cation: Technicians must be EGSA-certi ed or factory-trained on VAMC-speci c assets. Safety: All work must comply with the most recent NFPA 70E standards. The contractor is responsible for all Arc Flash PPE and for establishing a safe working perimeter. Record Management. . Documentation Requirements: Date of test Start and end time. Total run duration. Generator identi cation number/location. Load percentage or kW output. Voltage and frequency readings. Oil pressure and coolant temperature readings. Fuel level. Battery condition. Following NFPA 110\. 7.0 Record Retention. Generator test records shall be maintained for a minimum of three (3) years. Records may be maintained electronically or in hard copy available to the facility when requested. 8.0 Generator Description. GENSET #1 GENSET #2 GENSET #3 Manufacturer/Make/Year: Caterpillar Caterpillar Kato Model No: SR-4 C32 500SS9D Serial/Order No: 6NA01031 G1G00044 7319 Load Rating: (Emergency/Standby/Prime) 1000 kva 1250 kva 625KVA Power Factor: .8 .8 .8 Frequency: 60 Hertz 60 Hertz 60 hertz Load in Amperage: 1000 amps 1000 amps 87 Output Voltage: 480 480 volts 4160 volts Phase: 3-phase 3-phase 3-phase Building: Bld 17 Bld 17 Bld 17 Location (Area/Room): Generator room Generator Rm Generator Rm GENSET #4 GENSET #5 (portable) Manufacturer/Make/Year: Kohler Baldor Model No: 100RE0ZJF TS225-3J Serial/Order No: 3346GMJL0001 P1205240012 Load Rating: (Emergency/Standby/Prime) 128 kva 225 kva Power Factor: .8 .8 Frequency: 60 Hertz 60 Hertz Load in Amperage: 153 amps 625 amps Output Voltage: 480 480 volts Phase: 3-phase 3-phase Building: Parking Garage Grounds Location (Area/Room): Parking Garage Grounds (portable) Please respond to this RFI/Sources Sought 36C24526Q0352 with your: 1\. Business name (including Unique Entity ID (SAM.gov) 2\. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3\. Person of contact (including telephone number & email address). 4\. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. 5\. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) 6\. Brief Summary of categories of services that your company can/cannot provide. 7\. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) 8\. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: a. Do you intend to self-perform this effort? b. If you are located outside the immediate area, how will you self-perform? c. Or do you intend to subcontract work under this contract? d. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? Response Instructions: Responses must be submitted NLT 10:00 AM (ET) 03-20-2026, Responses to the information requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov. Respond: 36C24526Q0352 Sources Sought Notice | Company Name This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open. 

<!-- mobian-agent-ad sponsored="true" id="122cb586-7fd6-49d8-ba42-7fe3fdbb6da6" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8da5fe919b1f4d0e87ce8d041f067928/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/d9734331c6c643629e3bcc9855ed3e03/download)

## Contacts

* Bill Pratt, Contracting Officer

Email and phone are in the source notice.

[Source notice](https://sam.gov/workspace/contract/opp/3a839ba680884c8a8ae6a71a3905cde0/view)

[More from United States Department of Veterans Affairs posted in March 2026](/department%5Fof%5Fveterans%5Faffairs/archive/2026-03)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J049--Sources Sought Notice  Need a contractor for Generator Testing Services  Louis A Johnson VA Medical Center  36C24526Q0352","description":"Summary: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor to provide Generator Testing Services for the Louis A Johnson VA Medical Center. Review last page for details on how to respond to this Sources Sought notice. Scope of work: Location of work: Louis A Johnson VA Medical Center 1 Medical Ctr Dr, Clarksburg, WV 26301 Base plus Four (4) Option Year contract. This ensures the Louis A. Johnson VAMC maintains continuous compliance with the most recent VHA-adopted NFPA 110 and is fully prepared for The Joint Commission (TJC) and OIG inspections. 1.0 Contract Structure Base Year: [Dates] Option Years 1-4: To be exercised annually. Emergency Coverage: 24/7/365 On-call availability. 2.0 Scope of Work The contractor shall provide all labor, materials, and equipment to perform monthly, annual, and triennial testing, as well as emergency repair services. Monthly Operational Test Duration: Minimum 30 continuous minutes under facility load. Time-to-Transfer: Must reach operating voltage/frequency and transfer load within 10 seconds. ATS Rotation: Contractor shall rotate the initiating Automatic Transfer Switch (ATS) monthly to ensure all switches are cycled annually. Supplemental Load Bank Testing (As Required) In accordance with the most recent NFPA 110, Section 8.4.2, if a generator fails to reach the required 30% of the nameplate kW rating or the manufacturer s recommended exhaust gas temperature during the monthly run: Requirement: The contractor shall provide a portable load bank. Procedure: The unit shall be exercised for 2 hours annually at a load increasing to at least 75% of the nameplate rating. Triennial (36-Month) 4-Hour Run Once every 36 months, the contractor shall conduct a continuous 4-hour load test: First 3 Hours: Minimum 30% of nameplate kW. Final Hour: Minimum 75% of nameplate kW (utilizing a load bank if facility load is insufficient). 3.0 Emergency Response \u0026 Repair Response Time: The contractor shall provide emergency repair services with a maximum 2-hour on-site response time from the initial call by the M\u0026O Supervisor or Engineering Staff. Availability: This requirement applies 24 hours a day, 7 days a week, including holidays. Reporting: Any emergency repair must result in a \"Return to Service\" report documenting the FboNotice cause and the speci c NFPA 110 re-test performed to verify system readiness. 4.0 TJC \u0026 OIG Documentation Standards All reports must be \"Audit-Ready\" and submitted to the Facilities Management Service (FMS) within 72 hours. Speci c Data: Reports must include exact kW/Amperage, Hz, and exhaust temperatures. Battery Diagnostics: Conductance or speci c gravity readings are mandatory for each battery cell/unit. Certi cation: A signed attestation that the test met the most recent VHA/NFPA 110 performance criteria. 5.0 Contractor Quali cations \u0026 Safety Certi cation: Technicians must be EGSA-certi ed or factory-trained on VAMC-speci c assets. Safety: All work must comply with the most recent NFPA 70E standards. The contractor is responsible for all Arc Flash PPE and for establishing a safe working perimeter. Record Management. . Documentation Requirements: Date of test Start and end time. Total run duration. Generator identi cation number/location. Load percentage or kW output. Voltage and frequency readings. Oil pressure and coolant temperature readings. Fuel level. Battery condition. Following NFPA 110. 7.0 Record Retention. Generator test records shall be maintained for a minimum of three (3) years. Records may be maintained electronically or in hard copy available to the facility when requested. 8.0 Generator Description. GENSET #1 GENSET #2 GENSET #3 Manufacturer/Make/Year: Caterpillar Caterpillar Kato Model No: SR-4 C32 500SS9D Serial/Order No: 6NA01031 G1G00044 7319 Load Rating: (Emergency/Standby/Prime) 1000 kva 1250 kva 625KVA Power Factor: .8 .8 .8 Frequency: 60 Hertz 60 Hertz 60 hertz Load in Amperage: 1000 amps 1000 amps 87 Output Voltage: 480 480 volts 4160 volts Phase: 3-phase 3-phase 3-phase Building: Bld 17 Bld 17 Bld 17 Location (Area/Room): Generator room Generator Rm Generator Rm GENSET #4 GENSET #5 (portable) Manufacturer/Make/Year: Kohler Baldor Model No: 100RE0ZJF TS225-3J Serial/Order No: 3346GMJL0001 P1205240012 Load Rating: (Emergency/Standby/Prime) 128 kva 225 kva Power Factor: .8 .8 Frequency: 60 Hertz 60 Hertz Load in Amperage: 153 amps 625 amps Output Voltage: 480 480 volts Phase: 3-phase 3-phase Building: Parking Garage Grounds Location (Area/Room): Parking Garage Grounds (portable) Please respond to this RFI/Sources Sought 36C24526Q0352 with your: 1. Business name (including Unique Entity ID (SAM.gov) 2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3. Person of...","url":"https://matchawards.com/department_of_veterans_affairs/posts/116200482471858745","identifier":"36C24526Q0352","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J049 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MAINTENANCE AND REPAIR SHOP EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.5 Industrial Products Install / Maintenance / Repair","url":"https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair"}],"availabilityStarts":"2026-03-09","availabilityEnds":"2026-03-20","validThrough":"2026-03-20T23:59:59-04:00","areaServed":"Clarksburg, West Virginia 26301, UNITED STATES","sameAs":"https://sam.gov/workspace/contract/opp/3a839ba680884c8a8ae6a71a3905cde0/view"}