6550--Reagents and Consumables for Laboratory Tests. This is for Puget Sound VA Medical Center
- Status
- Closed, the response deadline passed on Feb 9, 2026
- Agency
- United States Department of Veterans Affairs
- Office
- VANCOUVER, USA
- Notice type
- Solicitation
- Solicitation number
- 36C26026Q0316
- NAICS
- 325413 - In-Vitro Diagnostic Substance Manufacturing
- PSC
- 6550 - IN VITRO DIAGNOSTIC SUBSTANCES, REAGENTS, TEST KITS AND SETS
- Category
- Medical Equipment and Accessories and Supplies (10.2)
- Posted
- 2026-02-03
- Deadline
- 2026-02-09
- Place of performance
- Seattle, Washington, UNITED STATES
Description
STATEMENT OF WORK 1.1. SCOPE OF PROCUREMENT: 1.1.1. The instruments shall have random access capability (if discrete testing is required) and be able to simultaneously perform the complete profile for VA Puget Sound Healthcare System with locations in Seattle and Tacoma/American Lake VA as described in Attachment A; meeting the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). 1.1.2. The Contractor is required to provide a continuously stocked inventory of reagents, standards, vendor provided Controls, supplies, disposables, validation materials, CAP proficiency testing, linearity materials, printers, scanners, computers and any other materials, to include replacement parts, required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration date must be clearly marked on reagent, standards and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. 1.1.3. Contractor is required to provide quality controls for troubleshooting and/or routine use as needed. 1.1.4. The Contractor will provide a detailed list of all parts and supplies that are to be purchased by the facility and are not included in the Cost Per Reportable Result (CPRR) contract. 1.1.5. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. 1.2. DEFINITIONS: The per patient reportable result price shall include costs covering: five-year equipment use, all reagents, validation materials, CAP survey materials, linearity materials, standards, contractor provided quality controls, supplies, consumable/disposable items, parts, printers, scanners, computers accessories and any other item required for the proper operation of the Contractor s equipment and necessary for the generation of a patient reportable result. This per patient reportable result price shall also encompass all costs associated with dilution; repeat and confirmatory testing required to produce a single patient reportable result. It shall also include the material to perform as well as all other costs associated with quality control, calibration and correlation study testing that is prescribed by the Clinical and Laboratory Standards Institute (CLSI). All necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and training for Government personnel. Contractors shall provide delivery, installation and removal of equipment at no additional charge. 1.2.2. Contractors are required to provide a price for each test that can be performed on its equipment. The CPRR price shall include costs covering five-year equipment use including the following: All reagents, standards, quality Contractor provided Controls, linearity materials, calibration verification materials, supplies, consumable/disposable items, parts, accessories. Including any other item required for the proper operation of the Contractor s equipment and necessary for the generation and reporting of a test result. All necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and training for Government personnel. Contractors are required to provide delivery, installation and removal of equipment at no additional charge. 1.2.3. Business Associate Agreement (BAA)- A business associate is an entity, including an individual, company, or organization that, on behalf of VHA, performs or assists in the performance of functions or activities involving the use or disclosure of protected health information (PHI), or that provides certain services involving the disclosure of (PHI). VHA is a covered entity under the HIPAA Privacy Rule (Privacy Rule). HIPAA regulations require VHA to execute HIPAA-compliant BAAs with certain entities that receives, uses, or discloses VHA PHI to perform some activity for VHA. These BAAs obligate VHA business associates to provide the same protections and safeguards to PHI that is required of VHA under the Privacy Rule. 1.2.4. Specimen Processing Automation Line Pre-analytical processing and archival processing equipment offered to the Seattle VA laboratory providing automation of specimen processing functions, as indicated in the general requirements section. 1.2.5. Specimen Management System - A component of the Processing Automation Line that directs and manages the operation and components of the pre-analytical processing/automation system. 1.2.6. Contractor Middleware Management System - A server installed with software that interfaces the testing instrumentation to the VA Laboratory Information System (LIS) or VA Middleware and can receive, process and send data following CLSI guidelines. 1.2.7. Throughput The speed that the equipment processes and/or operates reported in units per hour. GENERAL REQUIREMENTS: 1.2.8. Primary analyzer(s) Base equipment offered shall be new and shall fully support the scope of operations (minimal requirements). Depending upon the technical functionality and the capabilities of the individual manufacturer s instrumentation, one analyzer or multiple analyzers may be required to meet the productivity specifications defined herein. Analyzers offered shall provide sufficient capacity and throughput to meet the volume and service demands in those instances, the additional analyzer(s) shall, likewise, be considered primary instrumentation and shall meet all of the technical specifications of this solicitation. Those additional analyzer(s) offered meeting the definition of a primary analyzer may serve as a back-up analyzer (see definition below) and shall replace the requirement for offering that category of equipment. 1.2.8.1. (Applies only if selected) Back-up Analyzer; equipment required in support of operations for the VA laboratories in the event the primary analyzer(s) becomes non-operational/non-functional. In the instance that the mirror imaged analyzers become unavailable the back-up analyzer will be used. As such, the requirements for consumable supplies, i.e. reagents, quality control material, calibrators, etc., shall be minimal and corollary to the successful operation of the primary instrumentation. Specific tests that require back-up performance. Additional primary analyzers required for the performance of daily workload are not considered back-ups for the purposes of consumables, reagents, etc. 1.2.8.2. Installation (applies only if selected): Contractor will provide an alternate site for validation of the instrumentation if space is not available for side-by-side validation with existing instrumentation. Contractor will perform, at their cost, new validation studies as defined by the customer when instrumentation is installed in the final workspace. 1.2.9. Operational and Technical Features- The instrumentation offered shall be approved by the Food and Drug Administration (FDA): 1.2.9.1. Primary Processing Automation Line Instrumentation and Integrated Clinical Laboratory Chemistry/Immunochemistry Instrumentation and Robotics System (Automated track or line) for Seattle location only. The offerings for the Seattle location shall be in accordance with requirements listed below. Please include a clear description regarding how samples are transported on the rack. NOTE: American Lake location will not have Primary Processing Automation Line Instrumentation or need an Integrated Clinical Laboratory Chemistry/Immunochemistry Instrumentation and Robotics System (Automated track or line). 1.2.9.1.1. Sufficient capacity and throughput to meet the volume and service demands. 1.2.9.1.2. Includes a specimen management system to manage and track sample progress and position. 1.2.9.1.3. Seattle location only: Specimen archival through mapping of specimen location; for easy retrieval once moved off-line. (Specimen Management System). 1.2.9.1.4. Seattle location only: The ability, based on test requests, to sort and route specimens. (Line/track system/ Specimen Management System) 1.2.9.1.5. Seattle location only: The ability to send the primary tube or processed aliquots by means of a tracking system to the proper testing instrumentation to maximize efficiency and to maintain and standardize turnaround times of results. (Line/track system/ Specimen Management System) 1.2.9.1.6. Minimal operator intervention to introduce STAT specimens or to change a routine specimen priority. 1.2.9.1.7. The ability to detect processing errors and provide error notification. (Specimen Management System) 1.2.9.1.8. Seattle location only: The ability to separate the serum/plasma from the blood cells through the process of centrifugation. (Centrifuge) 1.2.9.1.9. Seattle location only: Ability to detect short samples and clots (Alliquoter) 1.2.9.1.10. Seattle location only: The ability to remove caps from blood collection tubes. (Decapper) 1.2.9.1.11. Seattle location only: The ability to recap and/or reseal - tubes. (Recapper) 1.2.9.1.12. Seattle location only: The ability to remove an aliquot of serum/plasma using disposable pipette tips to prevent contamination and move into another specimen tube or cup for analysis. (Aliquotter) 1.2.9.1.13. Seattle location only: The ability to print bar code labels and label daughter (aliquot) tubes to maintain positive specimen identification. 1.2.9.1.14. Seattle location only: The ability to connect all primary and back-up testing analyzers. 1.2.9.1.15. Seattle location only: Ensure immediate availability of primary tube after initial testing is completed. 1.2.9.1.16. Seattle location only: The ability to auto-archive, store and retrieve specimens. 1.2.9.1.17. Barcode reader stations must have the following capabilities: 1.2.9.1.17.1. The accuracy of the barcode reading must have less than a 1.0 % failure rate. 1.2.9.1.17.2. Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. 1.2.9.1.17.3. Equipment must accept, at a minimum, 10 characters in specimen identifier that is alpha, numeric, and/or alphanumeric concurrently. 1.2.9.1.18. Seattle location only: The ability to connect instrumentation from other vendors to the processing line. Offer must state what other instrumentation can be connected. 1.2.9.2. Seattle location only: Testing Instrumentation; The testing instrumentation must be an integrated platform with flexible, components that can be upgraded and or reconfigured on site and is approved by the Food and Drug Administration (FDA) at the time of proposal submission and shall have the following: 1.2.9.2.1. Sufficient capacity and throughput to meet the volume and service demands. 1.2.9.2.2. An instrument management system (internal to testing instrumentation) that provides/maintains the following: 1.2.9.2.3. Ability to monitor instrument performance. 1.2.9.2.3.1. Continuous monitoring of vital functions with immediate operator notification of failure(s) and on-board storage of these records. 1.2.9.2.3.2. Capability to detect and alert operator of out of range quality control results via flagged results on QC printout and visual alerts on display monitor. 1.2.9.2.3.3. Ability to store and retransmit patient records to the VA Laboratory Information system for a minimum 48 hours in case of interface outage. 1.2.9.2.3.4. Capability to record, store and print the following information: 1.2.9.2.3.4.1. Required quality control and instrument maintenance information. 1.2.9.2.3.4.2. Patient demographic information and specimen results. 1.2.9.2.3.5. On board reagent inventory system. 1.2.9.2.4. A bi-directional, bar-coded computer interface compatible with the current VA laboratory information system. The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system. 1.2.9.2.4.1. The accuracy of the barcode reading must have less than a 1.0 % failure rate. 1.2.9.2.4.2. Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. 1.2.9.2.4.3. Equipment must accept, at a minimum, 10 characters in specimen identifier that is alpha and/or numeric depending on site that may be enabled concurrently. 1.2.9.3. Bar coding of reagents and the ability to track reagent containers throughout the testing process using bar code technology. 1.2.9.4. Ability to prioritize STAT testing without compromising existing programmed testing. 1.2.9.5. Minimal operator intervention to introduce STAT specimens or to change a routine specimen to a STAT specimen, as well as introduce STAT specimens during a test run without aborting a run. Contractor will outline STAT procedure. 1.2.9.6. On board reagent stability, sufficient to accommodate both high and low volume use. See ATT A. 1.2.9.7. The ability to detect and alert operator of low reagent levels and the potential of depletion. 1.2.9.8. The ability to load and unload all reagents from the equipment during operation without interrupting testing in progress or have sufficient capacity to complete 24 hours of testing. 1.2.9.9. The ability to support multiple reagent lots of the same reagent on the equipment at the same time with active, valid calibrations. 1.2.9.10. The ability to maintain multiple calibrations per analyte. 1.2.9.11. The capability to calibrate assays during test run without aborting the run. 1.2.9.12. The capabilities to store, print, and retrieve calibration data. 1.2.9.13. For routine (general) chemistry tests, when more than one lot of a given reagent has a valid calibration and quality control material is programmed to run as a control (in the control mode): 1.2.9.13.1. Facility shall be notified if a new lot number is about to be run to ensure that quality control material is performed. 1.2.9.13.2. Quality control results will be easily distinguishable i.e., identified by reagent lot number or similar mechanism, on instrument printout or display monitor. 1.2.9.13.3. Operator may select to run a test on only a specified lot of reagent even though more than one lot has a valid calibration. 1.2.9.14. The ability to continuously load patient specimens. 1.2.9.15. The ability to detect short samples. 1.2.9.16. Clot detection with alert notification. 1.2.9.17. Primary tube sampling from various manufacturers and sizes of evacuated tubes. 1.2.9.18. The instrumentation shall be capable of handling all routine sample collection tubes e.g.: 13x75, 13x100, 16x100. plus, other various sized sample containers i.e., sample cups (0.5, 1.0, and 2.0 ml), carrier tubes and tube inserts. 1.2.9.19. Automatically repeat testing when defined limits are exceeded via auto dilution or sample volume adjustment. 1.2.9.20. The capability to program a test as a repeat with interfacing of results to overlay initial result. 1.2.9.21. Safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. 1.2.9.22. The backup analyzer will be a mirror image or have the same reagent requirement as the primary analyzer. 1.2.9.23. Calibration stability adheres to manufacture s specifications. 1.2.9.24. User defined/Open Channel test capability. In the event that the contractor cannot provide desired assays, the contractor will provide application development support for open channel test implementation. 1.2.10 Inventory Management System 1.2.10.1 The contractor shall provide an automated Inventory Management system to track and provide real time inventory of reagents and supplies. 1.2.11. Contractor Middleware Management System 1.2.11.1. The Contractor shall provide instrumentation and middleware that is compatible with VA LIS or interfaces directly with Data Innovations Middleware. 1.2.11.2. The Middleware shall be able to communicate via HL7 messages version 1.6 or later. 1.2.11.3. Middleware for clinical chemistry systems must be bidirectional interfaceable to include front end automation, laboratory /clinical information systems, third party middleware applications, laboratory instrumentation, current and future generations, for all other laboratory sections at no additional cost. 1.2.11.4. The Contractor shall provide the server(s) and Data Innovations Instrument Manager Middleware software, to include wrapper rules for Auto Verification, or other middleware that is compatible with VA LIS/middleware, and provide technical support for both the hardware and software for the duration of the contract. 1.2.11.5. All driver development shall be provided by the respective contractor, free-of-charge. 1.2.11.6. The middleware should have the ability to interface with regulatory agency applications. i.e. CAP. 1.2.11.7. The Contractor shall assist in the provision of the appropriate software drivers and interfaces for effective use of automated regulatory agency reporting features. 1.2.11.8. The Contractor shall assist in the establishment, testing, deployment, and troubleshooting of the full capacity of the Middleware before implementation date. 1.2.11.9. The Middleware shall contain systems that facilitate the analysis of laboratory pre-analytic, analytic, and post-analytic processes and the generation of summary reports for quality improvement and monitoring efforts. 1.2.11.10. Summary reports shall be interactive, customizable, and accessible on-demand. 1.2.11.11. Reports shall have, at a minimum, the flexibility to display information organized by department, workflow unit, desired time frame, production phase and priority. Software shall have the capability to drill down within the summary reports, identify problematic data and generate corrective action plans. 1.2.11.12. Canned summary reports shall include, at a minimum: Turnaround time, specimen and test volumes, instrument quality control, specimen quality indicators, and % auto-verification, % (and number) repeat tests. 1.2.11.13. The Middleware shall include moving averages system. The Contractor shall establish, test, deploy and troubleshoot the functionality of the moving averages system. 1.2.11.14. The patient moving average system should have real-time, failure notification capability and an auto verification interrupt function at the analyte, specimen, and patient or instrument level. 1.2.11.15. The Middleware shall include Boolean logic rule writing applications and contractor deveAttachments
More from United States Department of Veterans Affairs posted in February 2026