Description
Title: Inspection, Maintenance, and Repair of Automatic and Fire-Rated Doors – VA Northern California Health Care System (VANCHCS)
Description: The Department of Veterans Affairs, Network Contracting Office (NCO) 21, has a requirement for a contractor to provide all labor, materials, tools, equipment, supervision, and transportation necessary to perform comprehensive inspection, preventive maintenance (PM), testing, and repair services for automatic and fire-rated pedestrian door systems,.
Scope of Work: The Contractor shall maintain all automatic sliding and swinging doors, low- and high-energy operators, motion/presence sensors, control access systems, and fire-rated pedestrian doors,. Services shall ensure equipment functions safely, reliably, and in compliance with NFPA 80, NFPA 101, California Building/Fire Codes, and ANSI/BHMA A156.10 and A156.19 standards.
Key Requirements:
• Preventive Maintenance: Quarterly PM for automatic doors and annual inspection/functional testing for fire-rated doors and automatic door openers-.
• Emergency & Corrective Repair: The Contractor shall provide unscheduled maintenance and repairs upon request. Emergency after-hours service must be available 24/7 with a response time not exceeding six (6) hours. Routine corrective maintenance during business hours requires a response time of four (4) hours.
• Parts: Repairs requiring parts must be completed within 48 hours, subject to availability. All parts used must be Original Equipment Manufacturer (OEM) or approved equal.
• Certifications: Technicians must be American Association of Automatic Door Manufacturers (AAADM) certified or possess equivalent certification and experience.
• Reporting: Detailed service reports and Fire Door Inspection Reports (compliant with NFPA 80) are required within 14 calendar days of service,.
Place of Performance: Services are required at seven (7) locations within the VANCHCS:
1. Sacramento VA Medical Center (Mather, CA)
2. McClellan VA Outpatient Clinic (McClellan, CA)
3. Mare Island Outpatient Clinic (Vallejo, CA)
4. Travis Air Force Base – David Grant Medical Center (Fairfield, CA) – Note: DBIDS access required 14 days in advance
5. Travis Air Force Base – Sequoia Clinic (Fairfield, CA)
6. Stockton Community Based Outpatient Clinic (French Camp, CA)
7. Martinez Outpatient Clinic (Martinez, CA)
Contract Type: Firm-Fixed-Price with ) Contract Line Items (CLINs) for unscheduled repairs.
Attachments
- Attachment 1
- Attachment 2
- Attachment 3
- Attachment 4
- Attachment 5
- Attachment 6
- Attachment 7
- Attachment 8
- Attachment 9
- Attachment 10
Contacts
- Edwin Rivera, Contract Specialist
Email and phone are in the source notice.
More from United States Department of Veterans Affairs posted in January 2026