<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/115903790828050811" -->

---
title: VPRO Max2 Low Temp Sterilizers | Closed - MatchAwards
description: VPRO Max2 Low Temp Sterilizers. United States Department of Veterans Affairs. Solicitation 36C25526Q0154. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. Deadline 2026-01-21. 2. SPECIFICATIONS . Minimum of three low temperature sterilizers shall have a minimum...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/115903790828050811
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: VPRO Max2 Low Temp Sterilizers | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/115903790828050811
og:description: VPRO Max2 Low Temp Sterilizers. United States Department of Veterans Affairs. Solicitation 36C25526Q0154. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. Deadline 2026-01-21. 2. SPECIFICATIONS . Minimum of three low temperature sterilizers shall have a minimum...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# VPRO Max2 Low Temp Sterilizers

Status

Closed, the response deadline passed on Jan 21, 2026

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Sources Sought

Solicitation number

36C25526Q0154

NAICS

[334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing](/groups/514)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2026-01-14

Deadline

2026-01-21

Place of performance

Kansas City, Missouri 64128, UNITED STATES

## Description

2\. SPECIFICATIONS  
. Minimum of three low temperature sterilizers shall have a minimum individual dimensions of  
Cabinet (DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x 38-  
5/16 x 72” (838 x 973 x 1829 mm).  
o Mounting single door, cabinet  
o System installation requires no plumbing, ventilation or air  
o supply – only a dedicated electrical connection is needed. A power cord is supplied for  
this connection  
o The facility space in which the vehicle can occupy is approx. 35’ x 110’.  
. Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing heatsensitive  
materials because temperatures within the load currently do not exceed 55ºC (131ºF)  
and sterilization occurs in a low-moisture environment. Heat tolerant devices and materials can  
also be indicated for vaporized hydrogen peroxide sterilization processes. FDA-cleared vaporized  
hydrogen peroxide sterilizers, either with or without plasma, are currently available in the  
United States.  
. Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in an area  
with a ventilation system capable of at least 10 air exchanges per hour.  
. VPRO MaX2 must support utility requirements:  
o Current 16 AMP  
o Minimum Circuit Breaker 20 AMPS  
o Use NEMA L15-20R Plug  
o Provide grouped or ganged circuit protection and disconnect for phase 3 power as  
required by NEC and local codes.  
o Individual power shutoffs near each machine for servicing.

<!-- mobian-agent-ad sponsored="true" id="1d6a489f-9e23-4e28-93b6-413be6f7541c" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f73106613c564119864ffa307c94dd10/download)

[Source notice](https://sam.gov/workspace/contract/opp/4211ea88674841a19b166c31a5acd9f8/view)

[More from United States Department of Veterans Affairs posted in January 2026](/department%5Fof%5Fveterans%5Faffairs/archive/2026-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"VPRO Max2 Low Temp Sterilizers","description":"2. SPECIFICATIONS . Minimum of three low temperature sterilizers shall have a minimum individual dimensions of Cabinet (DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x 38- 5/16 x 72” (838 x 973 x 1829 mm). o Mounting single door, cabinet o System installation requires no plumbing, ventilation or air o supply – only a dedicated electrical connection is needed. A power cord is supplied for this connection o The facility space in which the vehicle can occupy is approx. 35’ x 110’. . Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing heatsensitive materials because temperatures within the load currently do not exceed 55ºC (131ºF) and sterilization occurs in a low-moisture environment. Heat tolerant devices and materials can also be indicated for vaporized hydrogen peroxide sterilization processes. FDA-cleared vaporized hydrogen peroxide sterilizers, either with or without plasma, are currently available in the United States. . Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in an area with a ventilation system capable of at least 10 air exchanges per hour. . VPRO MaX2 must support utility requirements: o Current 16 AMP o Minimum Circuit Breaker 20 AMPS o Use NEMA L15-20R Plug o Provide grouped or ganged circuit protection and disconnect for phase 3 power as required by NEC and local codes. o Individual power shutoffs near each machine for servicing.","url":"https://matchawards.com/department_of_veterans_affairs/posts/115903790828050811","identifier":"36C25526Q0154","category":"334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2026-01-14","availabilityEnds":"2026-01-21","validThrough":"2026-01-21T23:59:59-05:00","areaServed":"Kansas City, Missouri 64128, UNITED STATES","sameAs":"https://sam.gov/workspace/contract/opp/4211ea88674841a19b166c31a5acd9f8/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```