<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/115748442300612498" -->

---
title: H165--Nuclear Medical Physicist and MRSE… (36C25526Q0130) | Closed - MatchAwards
description: H165--Nuclear Medical Physicist  and MRSE Services  36C255-26-AP-0874  Robert J. Dole VAMC, Wichita, KS 67218. United States Department of Veterans Affairs. Solicitation 36C25526Q0130. NAICS 541380 - Testing Laboratories and Services. SDVOSB set-aside. Deadline 2026-01-23. This Sources Sought...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/115748442300612498
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H165--Nuclear Medical Physicist and MRSE… (36C25526Q0130) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/115748442300612498
og:description: H165--Nuclear Medical Physicist  and MRSE Services  36C255-26-AP-0874  Robert J. Dole VAMC, Wichita, KS 67218. United States Department of Veterans Affairs. Solicitation 36C25526Q0130. NAICS 541380 - Testing Laboratories and Services. SDVOSB set-aside. Deadline 2026-01-23. This Sources Sought...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H165--Nuclear Medical Physicist and MRSE Services 36C255-26-AP-0874 Robert J. Dole VAMC, Wichita, KS 67218

Status

Closed, the response deadline passed on Jan 23, 2026

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Sources Sought

Solicitation number

36C25526Q0130

NAICS

[541380 - Testing Laboratories and Services](/groups/902)

PSC

H165 - QUALITY CONTROL- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2026-01-20

Deadline

2026-01-23

Place of performance

Kansas, UNITED STATES

## Description

This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products and/or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this Sources Sought Notice in accordance with (IAW) FAR Part 15.201(e). The purpose of this Sources Sought Notice announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service- Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the products and/or services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) Company Name; (b) Address; (c) Point of Contact; (d) Phone, Fax, and Email; (e) UEI Number; (f) Cage Code; (g) Tax ID Number; (h) Type of Small Business, e.g., Services Disabled Veteran Owned Small Business, Veteran Owned Small business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, or Small Business HUBZone business, etc.; (i) State if your business has an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed below and provide the contract number; and (j) Must provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. Requirements: The VA Heartland Network 15 Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide a physicist service contract for the provision of qualified diagnostic medical physics services. It is the intent of the Government to award a contract to a single contractor for Nuclear Medical Physicist and MRSE (Magnetic Resonance Safety Expert) Services for the Robert J. Dole VA Medical Center located at 5500 E. Kellogg Avenue, Wichita, KS 66622-0001.This is a brand name or equal requirement. Please see the Performance Work Statement for more specific details. The North American Industry Classification System Code (NAICS Code) is 541380 (Radiation Testing Laboratories or Services), size standard $19.0 million. Based on this information, please indicate whether your company would be a Large or Small Business and have a socio-economic designation as a Small Business, VOSB or SDVOSB. Important Information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service- Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set- aside or full and open may be used. Responses to this notice shall be submitted via email to Erika Kobulnicky at Erika.Kobulnicky@va.gov. Telephone responses will not be accepted. Responses must be received no later than Monday, December 29, 2025, at 10:00AM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. Performance Work Statement (PWS) Robert J. Dole VA Medical Center Veterans Health Administration INTRODUCTION This solicitation is to provide the Veterans Health Administration, Robert J. Dole VA Medical Center (Wichita VAMC) is requesting the services of a qualified diagnostic medical physicist. A qualified diagnostic medical physicist is a person who is certified by the American Board of Radiology, American Board of Medical Physics, or the Canadian College of Physicists in Medicine. For diagnostic computed tomography (CT), nuclear medicine, PET, or MRI, a qualified diagnostic medical physicist can meet the following requirements in lieu of board certification: A graduate degree in physics, medical physics, biophysics, radiologic physics, medical health physics, or a closely related science or engineering discipline from an accredited college or university Formal graduate-level coursework in the biological sciences with at least one course in biology or radiation biology and one course in anatomy, physiology, or a similar topic related to the practice of medical physics Documented 3 years of clinical experience in CT, nuclear medicine, PET, or MRI. The physicist must document the 3 years of experience for the modality being inspected. The qualified diagnostic medical physicist (hereafter medical physicist) will conduct testing and performance monitoring for imaging equipment to ensure compliance with applicable Federal, State, and JCAHO regulations and guidelines. All tests will be documented in a formal report and submitted within five working days of completion of the work. These tests will be reported to Biomed and the Radiation Safety Officer (RSO). Provides radiological physics support for the Imaging Service activities involving the use of medical radiation in the diagnosis and treatment of disease. Support encompasses the establishment and management of a department radiation protection program and a comprehensive quality assurance program for diagnostic equipment (ultrasound, computed tomography, magnetic resonance imaging, nuclear medicine, angiography, general radiography and fluoroscopy). Must provide MRSE (Magnetic Resonance Safety Expert) services to be performed either in person or virtually and will be responsible for (1) Providing guidance to the VA medical facility Radiology Service Chief on the clinical and administrative aspects of the safe use of MR equipment; the development of local rules and procedures related to MR safety; nonroutine MR processes, including but not limited to implanted medical devices; and the development and maintenance of MR Safety programs and MR Quality Assurance programs. (2) Providing assistance and consultation to the MRSO and MRMD on the development of MRI protocols to allow the safe imaging of patients with MRI conditional implanted devices. (3) Actively participating in the planning, installation, and acceptance testing for new equipment at the VA medical facility. (4) Serving as the VA medical facility subject matter expert for any FboNotice cause analyses or administrative investigations related to MRI adverse events. BACKGROUND Robert J. Dole VA currently has a service contract (36C25521D0022) for physicist services that expires Jan 31, 2026\. A Base +4 contract will be needed to ensure maximum up time and our compliance with NHPP and ACR standards. SCOPE OF WORK Description of Work: The contractor shall provide Inspection services and MRSE (Magnetic Resonance Safety Expert) services Section A: Inspection Services The medical physicist shall perform imaging equipment (x-ray equipment, nuclear medicine cameras, PET/CT cameras, ultrasound units, and MRIs) inspections to ensure compliance with the current American College of Radiology (ACR) requirements. Equipment listed in Appendix A. Any deficiencies or non-conformances discovered during the inspection shall be verbally communicated to the service supervisor or RSO prior to the medical physicist leaving the facility. A written report of the results shall be provided to the service supervisor or RSO within 10 working days after completion of the inspection. Equipment Inspections The medical physicist shall conduct equipment inspections or quality control surveys of the imaging equipment listed below. The medical physicist shall ensure the imaging equipment s compliance with applicable Federal regulations and ACR recommendations, and shall include, but not be limited to, monitoring the following basic performance characteristics. A. Radiographic and Fluoroscopic Equipment Physics inspections of radiographic and fluoroscopic equipment shall comply with the ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiographic and Fluoroscopic Equipment. The performance of each radiographic and fluoroscopic unit must be evaluated at least annually. This evaluation should include, but not be limited to the following tests (as applicable). Integrity of unit assembly. Collimation and radiation beam alignment. Fluoroscopic system resolution. Automatic exposure control system performance. Fluoroscopic automatic brightness control performance (high-dose-rate, pulsed modes, field-of-view \[FOV\] variation). Image artifacts. Fluoroscopic phantom image quality. kVp accuracy and reproducibility. Linearity of exposure versus mA or mAs. Exposure reproducibility. Timer accuracy. Beam quality assessment (half-value layer). Fluoroscopic entrance exposure. Maximum output for all clinically used settings. Image receptor entrance exposure. Equipment radiation safety functions. Patient dose monitoring system calibration. Video and digital monitor performance. Digital image receptor performance. Grids used with portable x-ray units shall be imaged for uniformity. B. Computed Radiography (CR) and Digital Radiography (DR) Physics inspections of CR and DR equipment shall comply with the American Association of Physicist in Medicine (AAPM) Report Number 93, Acceptance Testing and Quality Control of Photostimulable Storage Phosphor Imaging Systems. The performance of CR and DR must be evaluated at least annually. This evaluation should include, but not be limited to, the following tests (as applicable). Component and Imaging Plate Physical Inspection and Inventory. Imaging Plate Dark Noise and Uniformity. Exposure Indicator Calibration. Linearity and Auto-ranging Response. Laser Beam Function. Limiting Resolution and Resolution Uniformity. Noise and Low-Contrast Resolution. Spatial Accuracy. Erasure Thoroughness. Aliasing/Grid Response. IP Throughput. Positioning and Collimation Errors C. CT Scanners The physics inspection shall conform to the 2012 ACR Computed Tomography Quality Control Manual. The performance of each CT scanner shall be evaluated at least annually. This evaluation should include, but not be limited to, the following tests (as applicable). Review of Clinical Protocol Scout Prescription and Alignment Light Accuracy. Image Thickness Axial Mode. Table Travel Accuracy. Radiation Beam Width. Low-Contrast Performance. Spatial Resolution. CT Number Accuracy. Artifact Evaluation. CT Number Uniformity. Dosimetry (the scanner displayed CTDIvol values must be within +/- 20% of the measured CTDIvol values). Gray Level Performance of CT Acquisition Display Monitors. D. Dental The physics inspection shall conform to the Conference of Radiation Control Program Directors (CRCPD), Quality Control Recommendations for Diagnostic Radiography Volume 1 Dental Facilities July 2001\. The performance of dental x-ray inspections shall be annually or every 2 years, need to be determined by facility. This evaluation should include, but not be limited to, the following tests (as applicable). Collimation. Beam quality (half value layer). Timer Accuracy and Reproducibility. kVp Accuracy and Reproducibility. mA or mAs Linearity. Exposure Reproducibility. Entrance Skin Exposure Evaluation. Technique Chart Evaluation. Image uniformity (artifact evaluation). Dental CBCT Acceptance and Performance Testing Acceptance Testing. Acceptance testing and measurements of air kerma at the isocenter for each kVp station for a range of clinically used mAs settings will performed initially when the CBCT unit is installed, and following any move of the CBCT to another area inside or outside the initial clinical site. This testing is to ensure that the equipment performance is in agreement with the manufacturer s technical specifications. Performance Testing. Each CBCT unit shall undergo periodic quality control tests to insure that the performance of the machine has not significantly deteriorated and is operating within the manufacturer s technical specifications. This performance testing is performed by a qualified expert annually, at intervals not to exceed 14 months, and after repairs to the CBCT unit that may affect the radiation output or image quality. Some manufacturers provide a phantom and procedures to perform machine specific quality assurance (QA) tests. In cases where the manufacturer provides a phantom and procedures to perform specific tests but the tests are not included in this SOW, then the manufacturer s machine-specific QA tests shall be performed in addition to the QA tests in this SOW. Acceptance and Annual physics testing for Dental CBCT Radiation output Repeatability Make four measurements of the air kerma at the isocenter at a clinically used setting. The measurements should be less than +/-5% of the average of the five measurements and the measurements should be less than +/- 5% of the previous year s measurement. Radiation Output Reproducibility Measure the air kerma at the isocenter for each kVp station and a range of clinically used mAs setting. Compare the results to the baseline values established at the initial acceptance testing. The values should be +/-5% of the baseline. kVp Accuracy Measure the kVp at all clinically used settings. The measured kVp should be +/-5% of the selected kVp. kVp Repeatability Make five kVp measurements each for two clinically used kVp settings. All measured values should be +/-5% of the mean kVp. kVp Reproducibility Measure the kVp at all available kVp settings. The measured values should be +/-5% of the baseline. Beam quality Measure the half value layer (HVL) for aluminum. The minimum shall comply with Section F.4.d of the Suggested State Regulations for Control of Radiation, Conference of Radiation Control Program Directors. Radiation field of view (FOV) Measure the width of the radiation field at the isocenter. The width of the beam should be 3 mm or 30% of the total nominal collimated width. Image Quality Image the phantom provided by the manufacturer or another suitable phantom. Assess high contrast spatial resolution, uniformity of transaxial images, and image noise. Imaging uniformity shall be assessed over the entire range of axial images. Accuracy of Linear Measurements Using images of an appropriate phantom, assess the accuracy of distance measurements. Accuracy of Patient Dose Metric Indication Assess the accuracy of the indicated dose metric (typically DAP). Patient Dose Assessment From a scan or scans using the facility s standard techniques, record the dose metric (typically DAP) and compare to achievable levels and diagnostic reference levels (if available) Review of the technical QA program The qualified expert shall review the technical QA program. The review shall include a trend analysis of the QA data. The results of the technical QA program review shall be included in the written report. Any trends that identify problems shall be included in the report along with recommended corrective actions. Display Monitors Perform a visual analysis of the SMPTE test pattern. Display the test pattern on the imaging console. Set the display window width/level to the manufacturer-specified values for the pattern. Do not set the window/level by eye; doing so invalidates the procedure. Examine the pattern to confirm that the gray level display in the imaging console is subjectively correct. Review the line pair patterns in the center and at each of the corners. Review the black-white transition. Look for any evidence of scalloping (loss of bit depth) or geometric distortion. Use a photometer to measure the maximum and minimum monitor brightness (0% and 100% steps) Measure additional steps within the pattern to establish a response curve. Measure the brightness near the center of the monitor and near all 4 corners (or all 4 sides, depending on the test pattern used). Viewing Conditions Assess the viewing conditions for the area in which the monitor used to evaluation the CBCT studies is located. F. MRI The physics inspection shall conform to the 2004 ACR Magnetic Resonance Imaging Quality Control Manual. The performance of each MRI scanner shall be evaluated at least annually. This evaluation should include, but not be limited to, the following tests (as applicable). Magnetic field homogeneity. Geometric accuracy. Inter-slice RF interference. Slice position accuracy. High-contrast resolution RF coil performance. Volume coils signal-to-noise ratio Volume coils image uniformity Volume coils ghosting ratio Phased array coils' signal-to-noise ratio Surface coils signal-to-noise ratio Slice thickness accuracy Low-contrast detectability Soft copy displays Technologist s QC program Site phantom inventory Site RF coil inventory G. PET The physics inspection shall conform to the 2012 ACR Computed Tomography Quality Control Manual. The performance of each CT scanner shall be evaluated at least annually. This evaluation should include, but not be limited to, the following tests (as applicable). Review of Clinical Protocols. Scout Prescription and Alignment Light Accuracy. Image Thickness Axial Mode. Table Travel Accuracy. Radiation Beam Width. Low-Contrast Performance. Spatial Resolution. CT Number Accuracy. Artifact Evaluation. CT Number Uniformity. Dosimetry (the scanner displayed CTDIvol values must be within +/- 20% of the measured CTDIvol values). Gray Level Performance of CT Acquisition Display Monitors H. Nuclear Medicine The physics inspection shall conform to the ACR annual performance tests for nuclear medicine cameras. The qualified diagnostic medical physics shall also perform the quarterly testing on all cameras and equipment as outlined by the ACR, NHPP/NRC. The performance of each nuclear medicine scanner shall be at least annually. This evaluation should include, but not be limited to, the following tests (as applicable). Intrinsic Uniformity: fail criteria: > 5.0% System Uniformity: fail criteria: > 5.0% Intrinsic or System Spatial Resolution: fail criteria: > 3.5 mm bars Relative Sensitivity: fail criteria: COV > 2.5% Energy Resolution: fail criteria: > 12% Count Rate Param 

<!-- mobian-agent-ad sponsored="true" id="75e0aae9-ad68-4663-8968-33dec5c7ef4d" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup
- Pursuit brief for this NAICS code (award history, who buys, past awardees): https://matchawards.com/naics/541380/brief?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=brief

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/0055bb64a9c34db1a1153eae28a8077a/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/77231434856546269b69719e3494fa0d/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f5503e09b5914eecb71fa63b94b7a62b/download)
* [Attachment 4](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f586f76dba1a41fabc3d80230ec2b81f/download)

## Contacts

* Erika Kobulnicky, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/workspace/contract/opp/d514b3746fa04ababc32a09072791311/view)

[More from United States Department of Veterans Affairs posted in December 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-12)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Professional Services Government Contracts Available Now](/contracts/professional-services)
* [Pursuit brief for NAICS 541380](/naics/541380/brief)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H165--Nuclear Medical Physicist  and MRSE Services  36C255-26-AP-0874  Robert J. Dole VAMC, Wichita, KS 67218","description":"This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products and/or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this Sources Sought Notice in accordance with (IAW) FAR Part 15.201(e). The purpose of this Sources Sought Notice announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service- Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the products and/or services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) Company Name; (b) Address; (c) Point of Contact; (d) Phone, Fax, and Email; (e) UEI Number; (f) Cage Code; (g) Tax ID Number; (h) Type of Small Business, e.g., Services Disabled Veteran Owned Small Business, Veteran Owned Small business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, or Small Business HUBZone business, etc.; (i) State if your business has an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed below and provide the contract number; and (j) Must provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. Requirements: The VA Heartland Network 15 Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide a physicist service contract for the provision of qualified diagnostic medical physics services. It is the intent of the Government to award a contract to a single contractor for Nuclear Medical Physicist and MRSE (Magnetic Resonance Safety Expert) Services for the Robert J. Dole VA Medical Center located at 5500 E. Kellogg Avenue, Wichita, KS 66622-0001.This is a brand name or equal requirement. Please see the Performance Work Statement for more specific details. The North American Industry Classification System Code (NAICS Code) is 541380 (Radiation Testing Laboratories or Services), size standard $19.0 million. Based on this information, please indicate whether your company would be a Large or Small Business and have a socio-economic designation as a Small Business, VOSB or SDVOSB. Important Information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service- Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set- aside or full and open may be used. Responses to this notice shall be submitted via email to Erika Kobulnicky at Erika.Kobulnicky@va.gov. Telephone responses will not be accepted. Responses must be received no later than Monday, December 29, 2025, at 10:00AM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this...","url":"https://matchawards.com/department_of_veterans_affairs/posts/115748442300612498","identifier":"36C25526Q0130","category":"541380 - Testing Laboratories and Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H165 - QUALITY CONTROL- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES"}],"availabilityStarts":"2026-01-20","availabilityEnds":"2026-01-23","validThrough":"2026-01-23T23:59:59-05:00","areaServed":"Kansas, UNITED STATES","sameAs":"https://sam.gov/workspace/contract/opp/d514b3746fa04ababc32a09072791311/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

