<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/115737598954163302" -->

---
title: Z1DA-- Elevator Maintenance, Testin and Repair -… (36C25226Q0164) | Closed - MatchAwards
description: Z1DA-- Elevator Maintenance, Testin and Repair - 585 Iron Mountain   (VA-26-00001274). United States Department of Veterans Affairs. Solicitation 36C25226Q0164. NAICS 238290 - Other Building Equipment Contractors. Total small business set-aside. Deadline 2026-02-12. Page 3 of 3 SOURCES SOUGHT...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/115737598954163302
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Z1DA-- Elevator Maintenance, Testin and Repair -… (36C25226Q0164) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/115737598954163302
og:description: Z1DA-- Elevator Maintenance, Testin and Repair - 585 Iron Mountain   (VA-26-00001274). United States Department of Veterans Affairs. Solicitation 36C25226Q0164. NAICS 238290 - Other Building Equipment Contractors. Total small business set-aside. Deadline 2026-02-12. Page 3 of 3 SOURCES SOUGHT...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Z1DA-- Elevator Maintenance, Testin and Repair - 585 Iron Mountain (VA-26-00001274)

Status

Closed, the response deadline passed on Feb 12, 2026

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

MILWAUKEE, USA

Notice type

Sources Sought

Solicitation number

36C25226Q0164

NAICS

[238290 - Other Building Equipment Contractors](/groups/229)

PSC

Z1DA - MAINTENANCE OF HOSPITALS AND INFIRMARIES

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2026-02-04

Deadline

2026-02-12

## Description

Page 3 of 3 SOURCES SOUGHT SYNOPSIS The Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify firms having an interest in and the resources to support a requirement for elevator maintenance and testing at the Iron Mountain VAMC in Iron Mountain MI. The result of this market research may contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 238290\. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Tentative requirements: The Contractor shall furnish all material, parts, labor, lubricants, hydraulic fluids, disposal, supervision, tools, shipping, travel and equipment necessary to provide full maintenance services, including all adjustments, tests, parts replacement related to preventative maintenance and repairs necessary to keep the elevators in continuous use at their initial performance ability (same speed, capacity, safety and efficiency) as originally specified by the equipment manufacturer as modified thereafter at the Oscar G. Johnson VAMC, 325 East H Street, Iron Mountain, MI 49801-4760\. The contractor shall provide all labor, materials, tools, and supervision to provide maintenance service, provide support for all testing and inspections; annual elevator re-call testing, semi-annual inspections and testing with federal elevator inspector including all full load, rupture valve, no load and any other required testing on all four (4) passenger elevators, one (1) freight elevator, and two (2) dumbwaiters. Also there is a 2 hour response time requirement for all emergency issues. If your Company has the potential capacity to perform these contract services, please provide the following information:1) Company name, address, email address, web site address, telephone number, and size and type of ownership for the company; 2) Tailored capability statements addressing the particulars of this effort, vehicle fleet size, and documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, companies should address the administrative and management structure of such arrangements; and 3) Confirmation your company can meet the Limitations of Subcontracting should they apply (see below) The government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated. Based on the responses to this synopsis and other market research, this requirement may be set-aside for small businesses (limitation of subcontracting would apply), small businesses (limitations on subcontracting would apply) or procured through full and open competition. Limitations on Subcontracting 13 CFR Â§125.6 will apply to any procurement set-aside for veteran-owned small businesses (SDVOSBs or VOSBs) or small businesses. 13 CFR Â§125.6 states: (a) General. In order to be awarded a full or partial small business set-aside contract with a value greater than the simplified acquisition threshold (as defined in the FAR at 48 CFR 2.101) in paragraph (a) introductory text; and an 8(a) contract, an SDVO SBC contract, a HUBZone contract, a WOSB or EDWOSB contract pursuant to part 127 of this chapter, a small business concern must agree that: (1) In the case of a contract for services (except construction), it will not pay more than 50% of the amount paid by the government to it to firms that are not similarly situated. Any work that a similarly situated subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Before any small or large business can be awarded a federal contract, a contracting officer (CO) must affirmatively determine that the firm is responsible to perform the specific contract it is otherwise in line to receive. If an apparent small business successful offeror is denied a contract award because it lacks certain elements of responsibility, the CO will refer the matter to the Small Business Administration. Once a CO s referral is received by the SBA s area office, the SBA will then inform the small business of the CO s determination and offer it the opportunity to apply to the SBA for a Certificate of Competency by a specific date. Burden of proof is on the small business to demonstrate that it meets specific COC eligibility criteria. After award, if a CO or other VA officials determine a review of limitations on subcontracting compliance is warranted based upon reasonable information of possible noncompliance, a request for review will be submitted to VA s Subcontracting Compliance Review Program. Submission Instructions: Interested parties who consider themselves qualified to perform the above-listed services are invited to submit a response to this Sources Sought Notice by 10:00 AM CST on December 23, 2025\. All responses under this Sources Sought Notice must be emailed to Michelle.klug2@va.gov. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. ELEVATOR & DUMBWAITER MAINTENANCE OSCAR G JOHNSON VAMC IRON MOUNTAIN MI STATEMENT OF WORK The Contractor shall furnish all material, parts, labor, lubricants, hydraulic fluids, disposal, supervision, tools, shipping, travel and equipment necessary to provide full maintenance services, including all adjustments, tests, parts replacement related to preventative maintenance and repairs necessary to keep the elevators in continuous use at their initial performance ability (same speed, capacity, safety and efficiency) as originally specified by the equipment manufacturer as modified thereafter per the Statement of Work at the Oscar G. Johnson VAMC, 325 East H Street, Iron Mountain, MI 49801-4760\. 1\. GENERAL SERVICES The contractor shall provide all labor, materials, tools, and supervision to provide maintenance service, provide support for all testing and inspections; annual elevator re-call testing, semi-annual inspections and testing with federal elevator inspector including all full load, rupture valve, no load and any other required testing on all four (4) passenger elevators, one (1) freight elevator, and two (2) - dumbwaiters identified in the Equipment Identification in Section 2 to include the following: A. Systematic examination of equipment Preventative maintenance on elevators shall be performed on a monthly basis, to include the code required monthly fire test on all elevators. Preventive maintenance on the 2 dumb waiters shall be performed semi-annually. Contractor technician(s) shall provide a minimum of eight (8) hours of onsite maintenance labor time per month to ensure elevator s and dumb waiter s operational up- time is acceptable. B. All adjustments, repairs and modifications, shall conform to the manufacturer guidelines, applicable codes and the following industry standards, as applicable, whichever is more stringent: ASME A17.1 Safety Code for Elevators and Escalators, latest edition ASME A17.2 Inspectors Manual for Elevators and Escalators, latest edition ASME A17.3 Safety Code for Existing Elevators and Escalators, latest edition ANSI NFPA 70 National Electric Code, latest edition Manufacturer s requirements and specifications on inspection, maintenance, and operation of each elevator and dumbwaiter model C. Contractor shall have in his possession throughout the term of the contract all diagnostic equipment necessary to fully maintain, test, repair, adjust or reprogram the systems. D. Contractor shall be required to attach tags or labels after testing as specified by Code, such as at the governor-releasing carrier, oil buffer, rupture valve test, etc. E. Any repairs or adjustments necessary to complete a test and return the elevator to service shall be performed by the Contractor at no additional expense to the Medical Center. F. Contractor shall maintain an adequate supply of spare parts to ensure prompt preventive maintenance and repair services. G. Contractor shall provide emergency call back service. H. The Contractor shall obtain all necessary licenses and/or permits required to perform the work if required. I. All tests or inspections that will remove the elevator from normal operation shall be scheduled in advance with the COR. J. The Government reserves the right to perform emergency repairs to any elevator which is Disabled if, in the Government s opinion, it jeopardizes patient or employee safety. 2\. EQUIPMENT Upon contract award, the contractor accepts "as is" all elevator equipment specified in the contract. Failure to inspect the elevators, prior to contract award, will not relieve the contractor from performing services/repairs in accordance with the strict intent and meaning of the specifications at no additional cost to the VA. Offerors should inspect the premises prior to submitting their offers in order to be fully aware of the scope of services required. Contractor shall provide service on the following Five (5) Elevators and Two (2) Dumbwaiters: 1) Elevator 1 Service Car: Motion control Engineering cable car, Motion 4000, S/N: 3336987, 8 stops, 11 openings 2) Elevator 2 West Passenger Car: Motion Control Engineering cable car, Motion 4000, S/N: 3336938, 7 Stops, 7 openings 3) Elevator 3 East Passenger Car: Motion Control Engineering cable car, Motion 4000, S/N: 3336982 7 stops, 7 openings 4) Elevator 4 North Passenger Car: Otis hydraulic, with HMC-2000 Controller, S/N: 2013077167 Openings, 5 Stops. EE# 20348 5) Elevator 6 North Out-Patient car: Otis Hydraulic Elevator, with HMC-2000 Controller, S/N: 864074, 2- Openings, 2- Stops. EE# 17484 6) Dumbwaiter DW 1: Otis Model 101, Electric Winding Drum, S/N: 132880 7) Dumbwaiter DW 2: Otis Model 101, Electric Winding Drum, S/N: 132881 3\. SPECIFIC TASKS A. The Contractor shall furnish all labor and supplies, parts and materials necessary to regularly and systematically clean, examine, adjust, lubricate as required and if conditions warrant, repair or replace as follows: 1\. Machine, worm gear, thrust bearings, drive sheave, drive sheave shaft bearings, brake pulley, brake coil, brake contact, brake linings and component parts. 2\. Machine motor, motor generator, motor windings, rotating element, commutator, brushes, brush holders and bearings. 3\. Controller, selector and dispatching equipment, all relays, solid state components, resistors, condensers, transformers, contacts, leads, dashpots, time devices, computer devices, CRT devices, selector tape or wire and mechanical and electrical driving equipment. 4\. Governor, governor cables/ropes, governor sheave and shaft assembly, bearings, contacts, and jaws. 5\. Deflector or secondary sheave, bearings, car and counterweight buffers, car and counterweight guide rails, top and bottom limit switches, governor tension sheave assembly, compensating sheave assembly, counterweight guide shoes including rollers.. 6\. Hoist way door interlocks, hoist way door hangers, bottom door guides and auxiliary door devices. 7\. Automatic power operated door operator, car door hanger, car door contact, door protective devices, load weighing equipment, car frame, car safety mechanism, platform, wood flooring, car guide shoes including gibs and rollers. 8\. Car operating panel(s) and equipment, hall lanterns, hall buttons and signal devices. 9\. Cab Lighting 10\. Where applicable to hydraulic elevators, include cylinder head, plunger exposed surfaces, gland and packing, pumps, exposed piping, fittings and flexible pipe connections, operating controls, check and relief valves, valves, gages and tanks. 11\. All parts and materials shall be of the original manufacturer s design and specification, or thereto. All lubricants shall be as recommended by the manufacturer. B. The Contractor shall: 1\. Examine periodically, all safety devices and governors and conduct an annual no load safety test and each fifth year for cable cars and three years for hydraulic cars; perform a , full speed test of safety mechanism, overhead speed governors, car and counterweight buffers. If required, the governor will be calibrated and sealed for proper tripping speed. 2\. Maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, re replace conductor cables and hoist way and machine room wiring. 3\. Keep car emergency light units in an operable condition at all times, test special emergency (fireman s service) service and emergency power circuits, where provided in accordance with Code requirements. 4\. Furnish lubricants specified to the various lubrication needs. 5\. Maintain a supply of contacts, coils, leads, brushes, lubricants, wiping cloths and other parts in each machine room for the performance of routine preventative maintenance. 6\. Maintain a complete set of current, legible schematic wiring diagrams in each elevator room for each elevator contained therein. 7\. Periodically clean hoist way including all equipment located in or moving through the Hoist way, car top, car sling, safeties, appliances, pits, sills, door tracks and hangers. monthly all elevator machine room floors. 8\. The Contractor shall ensure that the elevator pits(s) and elevator machine room(s) are and free from dirt and debris. Contractor shall clean and vacuum all HOISTWAY(s), pi machine rooms once a month to remove dust and debris accumulation. C. The Contractor shall comply with the following procedures when an elevator is removed from service for any reason: Notify Facilities Engineering Service Chief, Maintenance and Repair Supervisor, COR or his/her designee either by phone, or in person, before removing elevator from service. If work requires more than one day, daily notification will be made. Notification to the above-mentioned persons shall be given when placing the elevator back in service. D. The Contractor shall immediately notify the COR in writing of the existence or the development of any defects in, or repairs required to, the equipment covered under this contract, which the Contractor considers are not covered by the contract and shall furnish a written estimate of the proposed cost including material cost and labor charge breakdowns. Final determination of responsibility will be by mutual agreement between the COR and the Contractor. E. The CO, COR or designee must approve, in advance, any extra charge work attributed to vandalism or misuse which will be paid separate from this contract, on a separate purchase order. No invoice will be paid without prior approval and issuance of purchase order. Any repairs due to misuse or negligence shall be billed according to the labor rate specified in the pricing schedule. Parts will be billed at actual invoiced cost. Upon each departure, Contractor will serve notice of disposition of work and furnish a copy of a work order, service sheet or other such written notification of services performed as outlined below items (1) to (7). In the event the emergency repair is after hours, the Contractor can proceed with work with verbal purchase order and notice to proceed by phone from Engineering Chief, COR, Maintenance Supervisor, or his/her designee) Written reports will be provided on the next scheduled visit and will include: 1) Name and address of contractor 2) Name of contractor employee(s) performing the work 3) Date(s) work performed, and hours spent. 4) Person authorizing repair 5) Brief description of work performed, including PMI s and identification of equipment worked on. 6) Signature of contractor s employee(s) and signature of COR, Maintenance and Repair Supervisor or his designee. If the report is not submitted, it will indicate that no inspection or maintenance was performed and payment may be withheld and/or delayed. 7) Invoices- as outlined elsewhere in this contract must contain: parts cost, labor rate and hour Breakdown or invoices will not be paid. 4\. EMERGENCY RESPONSE A. The Contractor shall provide the COR with pertinent emergency telephone numbers, in order to summon assistance in case an emergency develops. At least one emergency telephone number shall be manned twenty-four (24) hours per day. This information shall be provided in writing to the COR, prior to the contract start date. B. Entrapments: Contractor shall respond to all entrapments as an emergency and shall have a technician on site within two (2) hours of being notified of entrapment if VA employees are not able to extradite trapped passengers. Contractor shall notify the VA with an estimated time of arrival (ETA) for technician being dispatched to confirm assistance is on the way. During Normal business hours: Engineering - (906) 774-3300 ext. 32200 After hours and weekends o Police Service (906) 774-330 ext. 32030 C. One elevator is out of service: Contractor s FSE must respond with a phone call to the COR or his/her designee within two (2) hours after receipt of telephone notification twenty-four (24) hours per day. If the problem cannot be corrected by phone, the FSE shall commence work (on-site physical response) within eight (8) hours after receipt of this second notice and shall proceed progressively to completion without undue delay. For example, since normal hours of coverage are Monday through Friday from 7:00 a.m. to 4:30 p.m., excluding holidays, a three (3) hour response means if a call is placed at 3:30 p.m. on a Friday, the FSE shall start on-site service before 9:00 a.m. Monday. D. Two (2) or more elevators out of service: Contractor s FSE shall respond and commence work, (on-site physical response) within four (4) hours after receipt of phone notification. 5\. TESTING & INSPECTIONS Testing typically takes place in June and December of each contract year or as otherwise specified below. A. Rupture Valve/Full Load Test/Bypass Relief/No Load : 1\. Cable Elevators a. Full load tests with weights shall be performed as follows on cable elevators: s/n 3336987, 3336938, and 3336982 once every 5 years; first test scheduled December 2029\. b. Annual - No Load Test 2\. Hydraulic Elevators - s/n 2013077167 and s/n 864074, a. Full load tests with weights shall be performed once every 3 years first test scheduled December 2027\. b. Rupture valve test 

<!-- mobian-agent-ad sponsored="true" id="34c2c176-ce80-4172-9198-4505b405610b" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/6f787389bed54ca8a41a369513bfb37a/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ea9771f9352e4ea1afc179adf417e2d0/download)

## Contacts

* Michelle R Klug, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/workspace/contract/opp/f06d5ae469d94c13aa009f5d5b2b5ab4/view)

[More from United States Department of Veterans Affairs posted in December 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-12)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)
* [Construction Government Contracts Available Now](/contracts/construction)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Z1DA-- Elevator Maintenance, Testin and Repair - 585 Iron Mountain   (VA-26-00001274)","description":"Page 3 of 3 SOURCES SOUGHT SYNOPSIS The Department of Veterans Affairs is issuing this sources sought synopsis as a means of conducting market research to identify firms having an interest in and the resources to support a requirement for elevator maintenance and testing at the Iron Mountain VAMC in Iron Mountain MI. The result of this market research may contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 238290. THERE IS NO SOLICITATION AT THIS TIME. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Tentative requirements: The Contractor shall furnish all material, parts, labor, lubricants, hydraulic fluids, disposal, supervision, tools, shipping, travel and equipment necessary to provide full maintenance services, including all adjustments, tests, parts replacement related to preventative maintenance and repairs necessary to keep the elevators in continuous use at their initial performance ability (same speed, capacity, safety and efficiency) as originally specified by the equipment manufacturer as modified thereafter at the Oscar G. Johnson VAMC, 325 East H Street, Iron Mountain, MI 49801-4760. The contractor shall provide all labor, materials, tools, and supervision to provide maintenance service, provide support for all testing and inspections; annual elevator re-call testing, semi-annual inspections and testing with federal elevator inspector including all full load, rupture valve, no load and any other required testing on all four (4) passenger elevators, one (1) freight elevator, and two (2) dumbwaiters. Also there is a 2 hour response time requirement for all emergency issues. If your Company has the potential capacity to perform these contract services, please provide the following information:1) Company name, address, email address, web site address, telephone number, and size and type of ownership for the company; 2) Tailored capability statements addressing the particulars of this effort, vehicle fleet size, and documentation supporting claims of organizational and staff capability. If significant subcontracting or teaming is anticipated in order to deliver technical capability, companies should address the administrative and management structure of such arrangements; and 3) Confirmation your company can meet the Limitations of Subcontracting should they apply (see below) The government will evaluate market information to ascertain potential market capacity to provide services consistent in scope and scale with those described in this notice and otherwise anticipated. Based on the responses to this synopsis and other market research, this requirement may be set-aside for small businesses (limitation of subcontracting would apply), small businesses (limitations on subcontracting would apply) or procured through full and open competition. Limitations on Subcontracting 13 CFR Â§125.6 will apply to any procurement set-aside for veteran-owned small businesses (SDVOSBs or VOSBs) or small businesses. 13 CFR Â§125.6 states: (a) General. In order to be awarded a full or partial small business set-aside contract with a value greater than the simplified acquisition threshold (as defined in the FAR at 48 CFR 2.101) in paragraph (a) introductory text; and an 8(a) contract, an SDVO SBC contract, a HUBZone contract, a WOSB or EDWOSB contract pursuant to part 127 of this chapter, a small business concern must agree that: (1) In the case of a contract for services (except construction), it will not pay more than 50% of the amount paid by the government to it to firms that are not similarly situated. Any work that a similarly situated subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Before any small or large business can be awarded a federal contract, a contracting officer (CO) must affirmatively determine that the firm is responsible to perform the specific contract it is otherwise in line to receive. If an apparent small business successful offeror is denied a contract award because it lacks certain elements of responsibility, the CO will refer the matter to the Small Business Administration. Once a CO s referral is received by the SBA s area office, the SBA will then inform the small business of the CO s determination and offer it the opportunity to apply to the SBA for a Certificate of Competency by a specific date. Burden of proof is on the small business to demonstrate that it meets specific COC eligibility criteria. After award, if a CO or other VA officials determine a review of limitations on subcontracting compliance is warranted based upon reasonable information of possible noncompliance, a request for review will be submitted to VA s...","url":"https://matchawards.com/department_of_veterans_affairs/posts/115737598954163302","identifier":"36C25226Q0164","category":"238290 - Other Building Equipment Contractors","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"Z1DA - MAINTENANCE OF HOSPITALS AND INFIRMARIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2026-02-04","availabilityEnds":"2026-02-12","validThrough":"2026-02-12T23:59:59-05:00","sameAs":"https://sam.gov/workspace/contract/opp/f06d5ae469d94c13aa009f5d5b2b5ab4/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```

