J041-- Boiler Plant Control Systems Preventative Maintenance Services B+4
- Status
- Closed, the response deadline passed on Dec 15, 2025
- Agency
- United States Department of Veterans Affairs
- Office
- AUGUSTA, USA
- Notice type
- Combined Synopsis/Solicitation
- Solicitation number
- 36C24726Q0127
- NAICS
- 561210 - Facilities Support Services
- PSC
- J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
- Category
- Facility Related Services (4.4)
- Set-aside
- Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Posted
- 2026-01-28
- Deadline
- 2025-12-15
- Place of performance
- Columbia, South Carolina 29209, UNITED STATES
Description
36C24726Q0127 Page 1 of Page 39 of 69 Page 1 of This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2025-06, dated 10-01-2025. This solicitation is set-aside for Service-Disabled Veteran-Owned Small Business concerns. To be considered for award prospective offerors must be registered and active in the System for Award Management (www.SAM.gov) and SBA verified SDVOSB Veteran Small Business Certification Veteran Small Business Certification (VetCert) (https://veterans.certify.sba.gov/) concern verified at the date and time set for receipt of offers. An Offeror, who is not SAM registered, or SBA Vet Cert verified SDVOSB concern at the date and time set for receipt of offers will have their offer rejected as non-responsive and will not be considered for award. The associated North American Industrial Classification System (NAICS) code for this procurement is 561210-Facilities Support Services, with a small business size standard of $47.0 Million. The FSC/PSC is J041. The Department of Veterans Affairs (VA), Veterans Integrated Service Network (VISN) 07, William Jennings Bryan Dorn VA Medical Center, 6439 Garners Ferry Rd., Columbia, SC 29209 is seeking to purchase Boiler Preventative Maintenance Services. All interested companies shall provide quotations for the following: Supplies/Services PRICE/COST SCHEDULE ITEM INFORMATION ITEM NUMBER DESCRIPTION OF SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 2.00 JB __________________ __________________ Contractor shall provide annual boiler maintenance for seven (7) boilers. The Contractor shall furnish all labor, travel, equipment, supplies and materials required to perform preventative maintenance and repair services of seven (7) boilers, including one (1) annual and one (1) semi-annual testing in accordance with the Statement of Work (SOW). Contract Period: Base POP Begin: 05-01-2026 POP End: 04-30-2027 1001 2.00 JB __________________ __________________ Contractor shall provide annual boiler maintenance for seven (7) boilers. The Contractor shall furnish all labor, travel, equipment, supplies and materials required to perform preventative maintenance and repair services of seven (7) boilers, including one (1) annual and one (1) semi-annual testing in accordance with the Statement of Work (SOW). Contract Period: Option 1 POP Begin: 05-01-2027 POP End: 04-30-2028 2001 2.00 JB __________________ __________________ Contractor shall provide annual boiler maintenance for seven (7) boilers. The Contractor shall furnish all labor, travel, equipment, supplies and materials required to perform preventative maintenance and repair services of seven (7) boilers, including one (1) annual and one (1) semi-annual testing in accordance with the Statement of Work (SOW). Contract Period: Option 2 POP Begin: 05-01-2028 POP End: 04-30-2029 3001 2.00 JB __________________ __________________ Contractor shall provide annual boiler maintenance for seven (7) boilers. The Contractor shall furnish all labor, travel, equipment, supplies and materials required to perform preventative maintenance and repair services of seven (7) boilers, including one (1) annual and one (1) semi-annual testing in accordance with the Statement of Work (SOW). Contract Period: Option 3 POP Begin: 05-01-2029 POP End: 04-30-2030 4001 2.00 JB __________________ __________________ Contractor shall provide annual boiler maintenance for seven (7) boilers. The Contractor shall furnish all labor, travel, equipment, supplies and materials required to perform preventative maintenance and repair services of seven (7) boilers, including one (1) annual and one (1) semi-annual testing in accordance with the Statement of Work (SOW). Contract Period: Option 4 POP Begin: 05-01-2030 POP End: 04-30-2031 GRAND TOTAL __________________ STATEMENT OF WORK Boiler Preventative Maintenance Services 1. REQUIREMENT: This requirement is for annual boiler plant control system maintenance on seven (7) boilers and associated systems, on behalf of the Columbia Healthcare System, WJB Dorn VA Medical Center, located in Columbia South Carolina. Contract Type: Firm-Fixed Price 2. BACKGROUND: The WJB Dorn VA Medical Center (VAMC) is a 216-bed facility, encompassing acute medical, surgical, psychiatric, and long-term care. The hospital is located in Columbia, South Carolina and provides primary, secondary, and some tertiary care. Satellite outpatient clinics are located in Anderson, Greenville, Florence, Orangeburg, Rock Hill, Sumter, and Spartanburg, South Carolina. 3. PERIOD OF PERFORMANCE: This procurement is for a Base Year with the possibility of Four (4), One (1) Year Options. Base Year May 1, 2026, through April 30, 2027 Option Year 1 May 1, 2027, through April 30, 2028 Option Year 2 May 1, 2028, through April 30, 2029 Option Year 3 May 1, 2029, through April 30, 2030 Option Year 4 May 1, 2030, through April 30, 2031 Work shall be performed during the hours of 8:00 a.m. through 4:00 p.m. from Monday through Friday. Excluding weekends and all federally observed holidays. At this time, no overtime is authorized. 4. PLACE OF PERFORMANCE: WJB Dorn VA Medical Center 6439 Garners Ferry Road Columbia, SC 29209 5. PERFORMANCE REQUIREMENTS: A Contracting Officer Representative (COR) and/or Alternate Contracting Officer Representative (ACOR) shall be assigned to this procurement, and written notification will be provided to the Contractor after contract is awarded. Scheduling of work performance shall be arranged through the designated COR/ACOR assigned. The Contractor shall provide annual boiler maintenance for seven (7) boilers. The Contractor shall furnish all labor, travel, equipment, supplies and materials required to perform preventative maintenance and repair services of seven (7) boilers. If a subcontractor is utilized, the Contractor shall provide a Subcontract Plan within 10 days of Contract award, that will include: Statement of Work. List of personnel that have had training with fireye controls who will be working on the boilers. Conveys fulfilling reporting requirements of all adjustments made to the controls to include previous settings to current settings signed off on by the technician Two semi-annual Testing and Maintenance services in accordance with VHA Directive 1810, current edition. Inspection and testing will be conducted and documented as defined in the latest VHA Boiler Plant Safety Device Testing Manual. All inspections and testing must be done by qualified individuals annually. At the conclusion of each inspection, the Customer will be provided with a written field service report detailing equipment condition and any recommendations for necessary repairs or enhancements to maintain system/equipment capacity, reliability, and efficiency. During the annual comprehensive inspection, an operational log will be completed and left with the Customer for their records. Any equipment deficiencies will be noted on the log and addressed outside the scope of this preventative maintenance agreement. Customer will be provided instructions to Customer s personnel who are responsible for Equipment operation and familiarize them with normal operation. The Boiler Plant Control System maintenance will consist of maintenance on four (4) Duel Fuel Boilers (#2 Fuel Oil/ Natural Gas), three (3) single fuel boilers, and all associated systems, covering the following areas: A: Server and Software Maintenance: 1. Server Maintenance Excluding Parts 2. Windows Updates 3. Kepware Updates 4. Iconics Updates 5. HC900 Firmware Updates 6. Fireye Firmware Updates 7. Software Maintenance/ Assistance 8. System Software Modifications (Control, Alarms, Trending, Reports, Graphics, etc.) 9. Boiler Plant monitors B. Boiler Combustion Control Point Calibration and Combustion Testing for Each Boiler as Applicable 1. Plant Master Control PV 2. Boiler Master Control Loop (Drum Pressure) 3. Combustion Air Control Loop (VFD, CMD, & FB/ Drum Level) 4. Gas Control Loop (Gas Valve CMD & FB/ Gas Flow) 5. Oil Control Loop (Oil Valve CMD &FB/ Oil Flow) 6. Feed Water Control Loop (Feed Water Valve CMD & FB/ Drum Level) 7. Furnace Pressure Control Loop (Stack Damper CMD &FB/ Furnace) 8. O2 Trim Loop 9. Boiler Steam Flow 10. Feed Water Flow 11. Windbox Pressure 12. Furnace Pressure 13. Boiler Outlet Pressure 14. Economizer Outlet Pressure 15. Economizer Inlet and outlet Gas Temperature and Water Temperature 16. Pilot Gas Pressure 17. Oil Pressures 18. Feed Water Pressure 19. Atomizing Media Pressure C. Boiler Safety Switch Calibration and Testing for Each Boiler 1. High Steam Pressure 2. High Furnace Pressure 3. Low Combustion Air Pressure 4. Low Instrument Air Pressure 5. High Gas Pressure 6. Low Gas Pressure 7. Low Oil/Steam Differential Pressure 8. Low Atomizing Media Pressure 9. High Oil Pressure 10. Low Oil Pressure 11. High Pilot Gas Pressure 12. High Water Alarm Switch 13. Low Water Alarm Switch 14. Low Water Cutout Probe 1 (Main) 15. Low Water Cutout Probe 2 (Auxiliary) D. Boiler Plant Loop Tuning for Each System 1. Main Steam Pressure 2. Main Steam Heater 1 Pressure 3. Steam PRV-1 4. Steam PRV-2 5. Steam PRV-3 6. Condensate Tank 1 Level Control 7. D/A Tank 1 Level Control 8. D/A Tank 1 Pressure Control 9. Continuous Blowdown Tank Level 10. Bottom Blowdown Tank E. Common Plant I/O Control and Instrumentation Preventative Maintenance and Calibration 1. Fuel Oil Tank Level Indication 2. City Water Filter Inlet Pressure 3. City Water Filter Outlet Pressure 4. Condensate Pressure (DA Intake) 5. PRV- 1, PRV-2, PRV-3 Condensate Return Flow 6. Feedwater Header Pressure (Primary and Secondary) 7. Ambient Relative Humidity and Temperature Sensor F. Conduct annual checks on Lochinvar boilers to include service. As per Service manual. 1. Clean heat exchanger 2. Remove and clean burner 3. clean blower wheel 4. Inspect ignition and flame sense electrodes 5. Check ignition ground wiring 6. Check all boiler wiring 7. check control settings G. Gas Detection System Preventative Maintenance and Calibration 1. Bump Test Each Local Sensor Semi Annually 2. Verify Calibration / Calibrate Each Local Sensor Annually H. All routine Repairs will have a response time of less than 24 hours I. Provide Emergency Service and after-hours response, if needed, to maintain system stability to the facility. 1. All emergency repairs, (especially the Master Control Panel), will have a response time of less than two (2) hours. 2. Boiler repairs to meet N+1 requirements must have 2-hour response time. 3. Contractor will provide an emergency recall plan that will include: 2-hour on site response time plan, to maintain VA requirements of N+1. Conveys fulfilling reporting requirements of all adjustments made to the controls to include previous settings to current settings signed off on by the technician The Contractor shall ensure that the area is clearly blocked off when commencement of work occurs so that no traffic of personnel disrupts services. The COR shall ensure the front entrance is secured and a detour sign posted for entry into the building if required during installation. EMERGENCY CALL IN REQUIREMENT: The Contractor shall provide a telephonic method for the facility to call in emergency work orders for the system during any failures at any time, 24 hours a day, 7 days a week. Upon notification of emergency failures, the Contractor shall have a qualified technician at the facility within two (2) hours to conduct necessary repairs. REPORT REQUIREMENT: The Contactor shall provide a report of service after each preventive maintenance occurs for each system. The report will be in accordance with (IAW) the current VHA Boiler and Associated Plant Safety Device Testing Manual and IAW VA Directive 1810. This report shall be submitted to the COR no later than ten (10) business days after each inspection occurs. The report shall contain a minimum of the following items. Date of Inspection Unit # Manufacturer, Model and Serial Numbers Previous Settings Current Settings Any areas of concern on each System Name of Inspector CHECK-IN REQUIREMENTS: Contractor and all Contractor s Service Personnel shall check in and out with Engineering in Building 20 prior to performing and upon completion of all required service. This information is required to contact mechanics in case of an emergency during regular hours. SAFETY REQUIREMENTS: Contractor shall ensure all tools and equipment are always secured. Tools and equipment must be removed from open areas or stored in secured location during breaks, lunch, and/or at the end of each workday. All debris must be removed from the facility upon completion of service each day. The WJB Dorn VA Medical Center is a smoke free campus. Smoking is not permitted indoors or on campus (except at the Regional Office location), to include parking lots, at any time. All smoking shall be conducted at designated smoking areas. TRAINING REQUIREMENTS: 10-Hour OSHA Training for all personnel involved with the required service Technicians must be fully trained on Fireye Controls A Site Visitation is required during the solicitation phase. Date and time will be coordinated through the COR, by the Contracting Officer (CO). All questions will be annotated during the site visit; however, answers will be provided to the CO only, who will in turn disseminate the information to the vendors. Included in vendor proposals will be a past performance report including two (2) years showing satisfactory performance under the same scope of work included in this Statement of Work, No. 5, Performance Requirements. 6. RECORDS MANAGEMENT LANGUAGE FOR CONTRACTS: The following standard items relate to records generated in executing the contract and should be included in a typical Electronic Information Systems (EIS) procurement contract: Citations to pertinent laws, codes and regulations such as 44 U.S.C chapters 21, 29, 31 and 33; Freedom of Information Act (5 U.S.C. 552); Privacy Act (5 U.S.C. 552a); 36 CFR Part 1222 and Part 1228. Contractor shall treat all deliverables under the contract as the property of the U.S. Government for which the Government Agency shall have unlimited rights to use, dispose of, or disclose such data contained therein as it determines to be in the public interest. Contractor shall not create or maintain any records that are not specifically tied to or authorized by the contract using Government IT equipment and/or Government records. Contractor shall not retain, use, sell, or disseminate copies of any deliverable that contains information covered by the Privacy Act of 1974 or that which is generally protected by the Freedom of Information Act. Contractor shall not create or maintain any records containing any Government Agency records that are not specifically tied to or authorized by the contract. The Government Agency owns the rights to all data/records produced as part of this contract. The Government Agency owns the rights to all electronic information (electronic data, electronic information systems, electronic databases, etc.) and all supporting documentation created as part of this contract. Contractor must deliver sufficient technical documentation with all data deliverables to permit the agency to use the data. Contractor agrees to comply with Federal and Agency records management policies, including those policies associated with the safeguarding of records covered by the Privacy Act of 1974. These policies include the preservation of all records created or received regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.] or state of completion [draft, final, etc.]. No disposition of documents will be allowed without the prior written consent of the Contracting Officer. The Agency and its Contractors are responsible for preventing the alienation or unauthorized destruction of records, including all forms of mutilation. Willful and unlawful destruction, damage or alienation of Federal records is subject to the fines and penalties imposed by 18 U.S.C. 2701. Records may not be removed from the legal custody of the Agency or destroyed without regard to the provisions of the agency records schedules. The contract period of performance is a base year with the possibility of four (4), one (1) year options. Base Year May 1, 2026, through April 30, 2027 Option Year 1 May 1, 2027 through April 30, 2028 Option Year 2 May 1, 2028 through April 30, 2029 Option Year 3 May 1, 2029 through April 30, 2030 Option Year 4 May 1, 2030 through April 30, 2031 Place of Performance/Place of Delivery Address: William Jennings Bryan Dorn VA Medical Center 6439 Garners Ferry Road Columbia, SC Postal Code: 29209 Country: UNITED STATES The full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far. The following solicitation provisions apply to this acquisition: FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services Provisions that are incorporated by reference (by Citation Number, Title, and Date), have the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. The following provisions are incorporated into 52.212-1 as an addendum to this solicitation: FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/ in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services. If paragraph (j) of the provision is applicable, a written submission is required. FAR 52.212-2 Evaluation-Commercial Products and Commercial Services [In accordance with FAR 12.301(c) when the use of evaluation factors is appropriate, the contracting officer may (1) Insert the provision at 52.212-2, Evaluation-Commercial Products and Commercial Services, in solicitations for commercial products or commercial services (see 12.602); or (2) Include a similar provision containing all evaluation factors required by 13.106, subpart 14.2 or subpart 15.3, as an addendum (see 12.302(d)).] The following contract clauses apply to this acquisition: FAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (NOV 2023) FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Products and Commercial Services (OCT 2025) (DEVIATION FEB 2025) The following subparagraphs of FAR 52.212-5 are applicable: Subparagraph b: 52.203 6, 52.204 10, 52.204 27, 52.204 30, 52.209 6, 52.219-8, 52.219 27, 52.219-28, 52.222-3, 52.222 35, 52.222 36, 52.222 37, 52.222-40, 52.222-50, 52.225-13, 52.226-8, 52.229 12, 52.232-33, 52.240 1. Subparagraph c: 52.222-41, 52.222-42, 52.222-43, 52.222-55, 52.222-62 52.217-8 OPTION TO EXTEND SERVICES (NOV 1999) The Government may require continued performance of any services within the limits and at the rates specified in the contract. These raAttachments
Contacts
- LaTerrica Sewell, Contracting Officer
Email and phone are in the source notice.
More from United States Department of Veterans Affairs posted in November 2025