<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/115598013412706547" -->

---
title: 6640--VISN 15 Automated Erythrocyte… (36C25526Q0092) | Closed - MatchAwards
description: 6640--VISN 15 Automated Erythrocyte Sedimentation Rate Analyzers -  36C255-26-AP-0538. United States Department of Veterans Affairs. Solicitation 36C25526Q0092. NAICS 334516 - Analytical Laboratory Instrument Manufacturing. Deadline 2025-12-05. This Sources Sought Notice is for planning purposes...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/115598013412706547
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6640--VISN 15 Automated Erythrocyte… (36C25526Q0092) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/115598013412706547
og:description: 6640--VISN 15 Automated Erythrocyte Sedimentation Rate Analyzers -  36C255-26-AP-0538. United States Department of Veterans Affairs. Solicitation 36C25526Q0092. NAICS 334516 - Analytical Laboratory Instrument Manufacturing. Deadline 2025-12-05. This Sources Sought Notice is for planning purposes...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6640--VISN 15 Automated Erythrocyte Sedimentation Rate Analyzers - 36C255-26-AP-0538

Status

Closed, the response deadline passed on Dec 5, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Sources Sought

Solicitation number

36C25526Q0092

NAICS

[334516 - Analytical Laboratory Instrument Manufacturing](/groups/520)

PSC

6640 - LABORATORY EQUIPMENT AND SUPPLIES

Category

[Test & Measurement Supplies (5.4)](/categories/industrial-products-and-services/test-and-measurement-supplies)

Posted

2025-11-21

Deadline

2025-12-05

Place of performance

UNITED STATES

## Description

This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products and/or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this Sources Sought Notice in accordance with (IAW) FAR Part 15.201(e). The purpose of this Sources Sought Notice announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service- Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the products and/or services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) Company Name; (b) Address; (c) Point of Contact; (d) Phone, Fax, and Email; (e) UEI Number; (f) Cage Code; (g) Tax ID Number; (h) Type of Small Business, e.g., Services Disabled Veteran Owned Small Business, Veteran Owned Small business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, or Small Business HUBZone business, etc.; (i) State if your business has an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed below and provide the contract number; and (j) Must provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. Requirement: The VA Heartland Network 15 Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide a Cost-Per-Test (CPT) Blanket Purchase Agreement (BPA) for Automated Erythrocyte Sedimentation Rate (ESR) Instrumentation. It is the intent of the Government to award a contract to a single contractor for Automated Coagulation Instrumentation for VISN 15 Heartland Network to include Kansas City VA Medical Center, Harry S. Truman Memorial Veterans' Hospital, Colmery-O'Neil VA Medical Center, Dwight D. Eisenhower VA Medical Center, Center, located in Kansas City, Missouri, and the John J. Cochran Veterans Hospital, Robert J. Dole VA Medical Center, St. Louis VA Medical Center Jefferson Barracks, St. Louis VA Medical Center John Cochran Division, Marion VA Medical Center, Evansville Health Care Center, John J. Pershing VA Medical Center and VA Cape Girardeau Health Care Center. This is a brand name or equal requirement. Please see the Statement of Work for more specifics and details. The North American Industry Classification System Code (NAICS Code) is 334516\. (Analytical Laboratory Instrument Manufacturing), size standard 1,000 Employees. Based on this information, please indicate whether your company would be a Large or Small Business and have a socio-economic designation as a Small Business, VOSB or SDVOSB. Important Information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service- Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set- aside or full and open may be used. Responses to this notice shall be submitted via email to Erika Kobulnicky at Erika.Kobulnicky@va.gov. Telephone responses will not be accepted. Responses must be received no later than Friday, December 5, 2025, at 7:00AM CST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation. STATEMENT OF REQUIREMENT VISN 15- HEARTLAND NETWORK Automated Erythrocyte Sedimentation Device SCOPE OF PROCUREMENT: It is the intent of VISN 15 Pathology & Laboratory Services to establish a Cost per Test agreement for Automated Erythrocyte Sedimentation Instrumentation. New equipment shall be acquired for each of the clinical laboratories located at the VISN facilities listed in Attachment A. Facilities within VISN 15 may be added or deleted by supplemental agreement of the Government and the Contractor. As requirements change, facilities within VISN 15 (Attachment A) may be added or deleted. Pricing to add new sites and/or equipment would be based on the costs spread out over the life of the remaining contract.Â Additional tests/reagents/instrumentation may be added to the BPA as new technology becomes available on the market and added to the base FSS contract. VISN 15 intends to establish the base year of the agreement for the period of 05/01/2026 through 04/30/2027\. This will be a single award, firm-fixed price with 5 ordering periods. The instrument shall have random access capability (if discrete testing is required) and be able to simultaneously perform the complete testing as described below meet the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). A total equipment footprint that when installed in the laboratory shall not impact on the functionality/operations of that laboratory. Equipment must maintain or, preferably, reduce the number of workstations or overall labor required to accomplish the required testing by each laboratory. If Contractor offers a family of analyzers, the technical evaluation panel will determine if instrumentation proposed meets needs of using facility. The Contractor is required to provide a continuously stocked inventory of reagents, standards, controls, supplies, disposables and any other materials required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration dates must be clearly marked on reagent, standard, and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. Estimated volumes of reagents can be found in Attachment A. Validation of new equipment must complete 30 days before expiration of current contract (April 30, 2026). DEFINITIONS: Cost per Patient Reportable Result (CPRR)- as defined in the Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers - Contractors are required to provide a price for a reportable patient result. The per patient reportable result price shall include costs covering: (1) 5-year equipment use, (2) all reagents, standards, quality controls, supplies, consumable/disposable items, parts, accessories and any other items required for the proper operation of the Contractor s equipment and necessary for the generation of a patient reportable result. This per patient reportable result price shall also encompass all costs associated with dilution, repeat and confirmatory testing required to produce a single patient reportable result. It shall also include the material to perform as well as all other costs associated with quality control, calibration and correlation study testing that is prescribed by the Clinical and Laboratory Standards Institute (CLSI). (3) all necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and (4) training for Government personnel. Contractors shall provide delivery, installation and removal of equipment at no additional charge. Business Associate Agreement (BAA)- A business associate is an entity, including an individual, company, or organization that, on behalf of VHA, performs or assists in the performance of functions or activities involving the use or disclosure of PHI, or that provides certain services involving the disclosure of protected health information (PHI). VHA is a covered entity under the HIPAA Privacy Rule (Privacy Rule). HIPAA regulations require VHA to execute HIPAA-compliant BAAs with certain entities that receive, uses, or discloses VHA PHI to perform some activity for VHA. These BAAs obligate VHA business associates to provide the same protections and safeguards to PHI that is required of VHA under the Privacy Rule. GENERAL REQUIREMENTS: Primary analyzer(s) Base equipment offered that shall fully support the scope of operations (minimal requirements). Depending upon the technical functionality and the capabilities of the individual manufacturer s instrumentation, one analyzer or multiple analyzers may be required to meet the productivity specifications defined herein. In those instances, the additional analyzer(s) shall, likewise, be considered primary instrumentation and shall meet all the technical specifications of this solicitation. Those additional analyzers(s) offered meeting the definition of a primary analyzer may serve as a back-up analyzer (see definition below) and shall replace the requirement for offering that category of equipment. Back-up Analyzer does NOT apply; equipment required in support of operations for the VA laboratories in the event the primary analyzer(s) becomes non-operational/non-functional. This category of equipment (loaners) shall only be operated during periods of time when the primary instrumentation is not available for use. As such, the requirements for consumable supplies, i.e. reagents, quality control material, calibrators, etc., shall be minimal and corollary to the successful operation of the primary instrumentation. Additional primary analyzers required for the performance of daily workload are not considered back-ups for the purposes of consumables, reagents, etc. Operational/Technical Features -The instrumentation offered shall have the following: Testing Instrumentation - The testing instrumentation must be approved by the Food and Drug Administration (FDA) and shall have the following: The capability of performing analysis of Erythrocyte Sedimentation Rate (ESR) The capability and throughput to meet the volume and service demands as defined in Attachment A. QC data management system and includes Levy-Jennings graphs. Analyzer must have the ability to capture & store QC data. Capability to detect and alert operator of out-of-range quality control results via flagged results on QC printout and visual alerts on display monitor. Ability to participate in peer data management system for quality control results. On board reagent inventory management must have: A system that provides reagent data to include but not limited to lot number and expiration date of reagents and quality control. Barcoding of reagents. On board reagent stability sufficient to accommodate both high and low volume use. Primary tube sampling from evacuated whole blood EDTA collection tubes from various manufacturers. The ability to continuously load patient specimens. The ability to detect short samples. The ability to perform testing on samples with 0.5 ml of whole blood. The ability to perform mixing of samples on board the analyzer. The ability to measure directly the intensity of red cell aggregation. Hardware Features- The instrumentation shall have the following: All monitors/screens will clearly display information in all light conditions. A printer that has the capability of printing a patient report with patient demographic information. that includes minimally the patient s name and accession or unique identifier number (UID). Interface Requirements A bi-directional, bar-coded computer interface compatible with the current VA laboratory information system and future system, Oracle Health (Formerly known as Cerner). The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. Equipment must accept, at a minimum, 10 characters in specimen identifier that is alphanumeric that may be enabled concurrently. A barcode reading accuracy rate of 99% or greater. The Contractor shall be responsible for providing all hardware required for the connection, implementation, and operation of the interface to the universal interface and any incremental fee that is required each time an instrument is added to an existing universal interface system (see Attachment A). Analyzer must have a bi-directional HL7 interface with Dual TCP/IP capability. The vendor shall provide assistance with setting up Autoverification through Data Innovations, and work with the Laboratory LIMs to interface VISTA LIS with vendor provided instruments. Provide remote or onsite guidance on validation techniques and assist troubleshooting. Provide support and guidance during modifications of final Autoverification build. For example, modifying rules logic cutoff based on evolving SOPs. The Contractor shall provide any and all necessary software support for ensuring that successful interfacing has been established. Specific requirements for the communication of the data streams will be unique to the instrument system involved and dictated by the manufacturer itself. Information necessary to make the determination for type and amount of interfacing equipment is supplied in Attachment A. If a site already has a universal interface box, the Contractor is responsible for everything leading up to the box including any incremental fee required to add additional equipment (e.g. licenses, ports/cards, cables, software, etc.) to the universal interfacing system. If a site does not have a universal interface and one is needed to optimally interface the instrument, then the Contractor is responsible for the acquisition of the universal interface box and everything else needed to connect with VA computerized hospital information system. If there are any software upgrades in the instrument during its life, the Contractor is responsible for seeing that the interface can accommodate any changes in the data stream going to the VA computerized hospital information system. Analyzer must function using an operating system that is approved to connect to the VA computer systems. Vendor must complete the following documentation that is attached to the solicitation: 6550 Pre-Procurement Assessment MDS2 ACL Communication Profile Current ISA/MOU and BAA with the VA, if applicable Contractor shall provide that are applicable for remote connection to the interface system used to manage the testing system. Method Performance/Validation Requirements Method performance/comparison shall be completed by and at the expense of the Contractor, shall include linearity material and reagents, and be consistent with current CLSI guidelines and related documents, College of American Pathologists (CAP) standards and Federal regulations. Correlation studies for each analyte. A minimum of 40 samples spanning the reportable range, shall be run by the present and the proposed method. In systems where multiple sampling modes exist, mode to mode correlation studies must also be performed. Contractor shall analyze results and provide statistical data to support acceptance of the new method for above studies. Statistics shall consist of at least mean, bias, slope, y-intercept, correlation coefficient, ROC analysis, and meet current standards defined by CLSI. Analytical Measurement Range (AMR) Validation shall be performed on proposed instrument(s) for each analyte to validate the reportable range. The material must have values which are near the low, mid, and high values of the AMR and be of appropriate matrix for the clinical specimens assayed by that method. A minimum 5-point linearity analysis that adheres to the Beer-Lambert Law and spans the entire range shall be performed as a minimum. Precision studies using normal and abnormal control material. This shall consist of a within-run precision study of 10 normal and 10 abnormal controls and a day-to-day precision study of normal controls and abnormal controls for 10 days (maybe run twice a day) for a total of 20 values per level of control. Intra-VISN facility variations should be kept at an absolute minimum. Sensitivity. Sensitivity may be validated concurrently with correlation studies. Mathematical calculations to determine efficiency, sensitivity, false positive rate, and false negative rate are applied. Specificity Studies. A review of product literature and assay inserts to determine any adverse effects for increased bilirubin, hemolysis, lipemia, or other interrupting substances. Reference Range A reference range must be determined for each test following CLSI Guidelines. Samples used for the reference range study must be representative of the patient population being tested. One of the following protocols shall be used: A verification of the manufacturer s suggested reference range may be performed as long as the suggested range is based on a comparable population of test subjects. The manufacturer shall provide specific information defining how the suggested range was determin 

<!-- mobian-agent-ad sponsored="true" id="44d8d46b-0f14-4e31-900f-e44ee980da06" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/test-and-measurement-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/969e18cca63447ea84d1bbf02b245911/download)

[Source notice](https://sam.gov/workspace/contract/opp/2bc171622b914ee08c5ad11acba6170c/view)

[More from United States Department of Veterans Affairs posted in November 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-11)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6640--VISN 15 Automated Erythrocyte Sedimentation Rate Analyzers -  36C255-26-AP-0538","description":"This Sources Sought Notice is for planning purposes only and shall not be considered as an invitation for bid, request for quotation, request for proposal, or as an obligation on the part of the Government to acquire any products and/or services. Your response to this Sources Sought Notice will be treated as information only. No entitlement to payment of direct or indirect costs or charges by the Government will arise because of contractor submission of responses to this announcement or the Government use of such information. This request does not constitute a solicitation for proposals or the authority to enter negotiations to award a contract. No funds have been authorized, appropriated, or received for this effort. The information provided may be used by the Department of Veterans Affairs in developing its acquisition approach, statement of work/statement of objectives and performance specifications. Interested parties are responsible for adequately marking proprietary or competition sensitive information contained in their response. The Government does not intend to award a contract based on this Sources Sought Notice or to otherwise pay for the information submitted in response to this Sources Sought Notice. The submission of pricing, capabilities for planning purposes, and other market information is highly encouraged and allowed under this Sources Sought Notice in accordance with (IAW) FAR Part 15.201(e). The purpose of this Sources Sought Notice announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service- Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the products and/or services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) Company Name; (b) Address; (c) Point of Contact; (d) Phone, Fax, and Email; (e) UEI Number; (f) Cage Code; (g) Tax ID Number; (h) Type of Small Business, e.g., Services Disabled Veteran Owned Small Business, Veteran Owned Small business, 8(a), HUBZone, Women Owned Small Business, Small Disadvantaged Business, or Small Business HUBZone business, etc.; (i) State if your business has an FSS contract with GSA, VA NAC, NASA SEWP, or any other federal contract, that can be utilized to procure the requirement listed below and provide the contract number; and (j) Must provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. Requirement: The VA Heartland Network 15 Contracting Office located at 3450 South 4th Street, Leavenworth, KS, 66048-5055 is seeking a potential qualified contractor to provide a Cost-Per-Test (CPT) Blanket Purchase Agreement (BPA) for Automated Erythrocyte Sedimentation Rate (ESR) Instrumentation. It is the intent of the Government to award a contract to a single contractor for Automated Coagulation Instrumentation for VISN 15 Heartland Network to include Kansas City VA Medical Center, Harry S. Truman Memorial Veterans' Hospital, Colmery-O'Neil VA Medical Center, Dwight D. Eisenhower VA Medical Center, Center, located in Kansas City, Missouri, and the John J. Cochran Veterans Hospital, Robert J. Dole VA Medical Center, St. Louis VA Medical Center Jefferson Barracks, St. Louis VA Medical Center John Cochran Division, Marion VA Medical Center, Evansville Health Care Center, John J. Pershing VA Medical Center and VA Cape Girardeau Health Care Center. This is a brand name or equal requirement. Please see the Statement of Work for more specifics and details. The North American Industry Classification System Code (NAICS Code) is 334516. (Analytical Laboratory Instrument Manufacturing), size standard 1,000 Employees. Based on this information, please indicate whether your company would be a Large or Small Business and have a socio-economic designation as a Small Business, VOSB or SDVOSB. Important Information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to an acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. Currently a total set-aside for Service- Disabled Veteran Owned Small Business firms is anticipated based on the Veterans Administration requirement with Public Law 109-461, Section 8127 Veterans Benefit Act. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set- aside or full and...","url":"https://matchawards.com/department_of_veterans_affairs/posts/115598013412706547","identifier":"36C25526Q0092","category":"334516 - Analytical Laboratory Instrument Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6640 - LABORATORY EQUIPMENT AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.4 Test \u0026 Measurement Supplies","url":"https://matchawards.com/categories/industrial-products-and-services/test-and-measurement-supplies"}],"availabilityStarts":"2025-11-21","availabilityEnds":"2025-12-05","validThrough":"2025-12-05T23:59:59-05:00","areaServed":"UNITED STATES","sameAs":"https://sam.gov/workspace/contract/opp/2bc171622b914ee08c5ad11acba6170c/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

