<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/115156421636158302" -->

---
title: 6515--VISN 23 Bio Safety Cabinets/Grossing… (36C26325Q1095) | Closed - MatchAwards
description: 6515--VISN 23 Bio Safety Cabinets/Grossing Stations - Multiple Locations. United States Department of Veterans Affairs. Solicitation 36C26325Q1095. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2025-12-12. Statement of Work VISN 23 Grossing Station/BioSafety Cabinet...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/115156421636158302
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515--VISN 23 Bio Safety Cabinets/Grossing… (36C26325Q1095) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/115156421636158302
og:description: 6515--VISN 23 Bio Safety Cabinets/Grossing Stations - Multiple Locations. United States Department of Veterans Affairs. Solicitation 36C26325Q1095. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2025-12-12. Statement of Work VISN 23 Grossing Station/BioSafety Cabinet...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515--VISN 23 Bio Safety Cabinets/Grossing Stations - Multiple Locations

Status

Closed, the response deadline passed on Dec 12, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

Saint Paul, USA

Notice type

Solicitation

Solicitation number

36C26325Q1095

NAICS

[339112 - Surgical and Medical Instrument Manufacturing](/groups/582)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2025-11-28

Deadline

2025-12-12

## Description

Statement of Work VISN 23 Grossing Station/BioSafety Cabinet Replacement Procurement Background: Several sites in VISN 23 are in need of replacing their current grossing stations in the Histology Laboratories. These grossing stations have reached the end of their life expectancy and we have begun to see an increase in the stations experiencing issues that require a service call. The increased downtime of these machines greatly impacts the speed and efficiency of the labs throughout the VISN in performing specimen examination. Additionally, the labs are seeking a newer model of grossing station which has additional features that would increase the speed, efficiency, and safety of the staff performing specimen examinations. Purpose of Project: Replace 8 grossing stations throughout VISN 23\. Specifically 4 in Minneapolis and 1 each in Omaha (NWI), Fargo, Central Iowa, and Iowa City. Each of these sites have grossing stations that are past their life expectancy and are experiencing an increase in service calls. Statement of Work Description of Work: The vendor will provide the following quantities of grossing stations with the following features as required by site: Minneapolis QTY 4 Grossing Stations no larger than 60 inches long to fit into existing space Right hand sink Air Flow Detection with monitoring system Adjustable lighting Air Filtration System to prevent dust & debris build up Ventilation system Dual 8 (or comparable) duct stubs for in-house ventilation Hot/Cold Hand Sprayer Mechanism for mounting of monitor & keyboard arms Pegboard (or comparable) for mounting of accessories Include dye bottle holder Include large shelf approximately 14 L x 8 D x 2 H Include small shelf approximately 7 L x 8 D x 2 H Include bin for paper towels/c-fold gloves Include magnetic toolbar (or comparable) Two (2) GFCI receptacles, one (1) each with continuous power Work surface with interchangeable workflow components One (1) work surface perforated grid plate (or comparable) One (1) work surface dissecting board (or comparable) Mechanism for cord management 1/2 Hp. Disposal (or comparable) Magnetic instrument bar (or comparable) One (1) large and one (1) small organizer bin Mechanism for anchoring points Touchscreen monitor (or comparable) Monitor/keyboard mounting column Dual gooseneck LED task light (or comparable) At least 3 (2 small approximately 6 W x W 7 D x 4 H and 1 large approximately 26.5 W x 7 D X 4 H)) drawers per grossing station Rinsing system for work surface with temperature and flow control Formalin collection system Faucet with foot pedal control Omaha (NWI) QTY 1 Grossing Station no larger than 60 inches long to fit into existing space Right hand sink Air Flow Detection with monitoring system Adjustable lighting Air Filtration System to prevent dust & debris build up Ventilation system Dual 8 (or comparable) duct stubs for in-house ventilation Hot/Cold Hand Sprayer Mechnanism for mounting of monitor & keyboard arms Pegboard (or comparable) for mounting of accessories Include large shelf approximately 14 L x 8 D x 2 H Two (2) GFCI receptacles, one (1) each with continuous power Work surface with interchangeable workflow components One (1) work surface perforated grid plate (or comparable) One (1) work surface dissecting board (or comparable) Mechanism for cord management 1/2 Hp. Disposal (or comparable) Magnetic instrument bar (or comparable) One (1) large and one (1) small organizer bin Mechanism for anchoring points Touchscreen monitor (or comparable) Formalin collection system Hands free infared faucet Cabinet doors Fargo QTY 1 Grossing Station no larger than 60 inches long to fit into existing space Right hand sink Air Flow Detection with monitoring system Adjustable lighting Air Filtration System to prevent dust & debris build up Ventilation system Dual 8 (or comparable) duct stubs for in-house ventilation Hot/Cold Hand Sprayer Mechanism for mounting of monitor & keyboard arms Pegboard (or comparable) for mounting of accessories Include dye bottle holder Include large shelf approximately 14 L x 8 D x 2 H Include small shelf approximately 7 L x 8 D x 2 H Include bin for paper towels/c-fold gloves Include requisition holder should fit 8.5 x 11 requisitions Two (2) GFCI receptacles, one (1) each with continuous power Work surface with interchangeable workflow components One (1) work surface perforated grid plate (or comparable) One (1) work surface dissecting board (or comparable) Mechanism for cord management 1/2 Hp. Disposal (or comparable) Magnetic instrument bar (or comparable) One (1) large and one (1) small organizer bin Mechanism for anchoring points Touchscreen monitor (or comparable) Monitor/keyboard mounting column Single gooseneck LED task light (or comparable) At least 2 small approximately 6 W x W 7 D x 4 H drawer Rinsing system for work surface with temperature and flow control Formalin collection system Faucet with foot pedal control Central Iowa QTY 1 Grossing Station no larger than 60 inches long to fit into existing space Right hand sink Air Flow Detection with monitoring system Adjustable lighting Air Filtration System to prevent dust & debris build up Ventilation system Dual 8 (or comparable) duct stubs for in-house ventilation Hot/Cold Hand Sprayer Mechanism for mounting of monitor & keyboard arms Pegboard for mounting of accessories (or comparable) Include bin for paper towels/c-fold gloves Include requisition holder should fit 8.5 x 11 requisitions Two (2) GFCI receptacles, one (1) each with continuous power Work surface with interchangeable workflow components One (1) work surface perforated grid plate (or comparable) One (1) work surface dissecting board (or comparable) Mechanism for cord management 1/2 Hp. Disposal (or comparable) Magnetic instrument bar (or comparable) One (1) large and one (1) small organizer bin Mechanism for anchoring points Touchscreen monitor (or comparable) Keyboard arm mounting column Single gooseneck LED task light (or comparable) At least 2 small approximately 6 W x W 7 D x 4 H drawer Rinsing system for work surface with temperature and flow control Formalin collection system Under shelf lighting for work space Iowa City QTY 1 Grossing Station no larger than 72 inches long to fit into existing space Right hand sink Air Flow Detection with monitoring system Adjustable lighting Air Filtration System to prevent dust & debris build up Ventilation system Dual 8 (or comparable) duct stubs for in-house ventilation Hot/Cold Hand Sprayer Mechanism for mounting of monitor & keyboard arms Pegboard for mounting of accessories (or comparable) Include 2 dye bottle holders Include face shield holster (or comparable) Include bin for paper towels/c-fold gloves Include requisition holder should fit 8.5 x 11 requisitions Include 2 large shelves approximately 14 L x 8 D x 2 H Include 3 small shelves approximately 7 L x 8 D x 2 H Include magnetic toolbar (or comparable) Two (2) GFCI receptacles, one (1) each with continuous power Work surface with interchangeable workflow components One (1) work surface perforated grid plate (or comparable) One (1) work surface dissecting board (or comparable) Mechanism for cord management 1/2 Hp. Disposal (or comparable) Magnetic instrument bar (or comparable) One (1) large and one (1) small organizer bin Mechanism for anchoring points Touchscreen monitor (or comparable) Keyboard/monitor mounting column CPU mount dual gooseneck LED task light (or comparable) At least 3 (1 small approximately 6 W x W 7 D x 4 H drawer, 1 small instrument approximately 6 W x W 7 D x 4 H with drain petcock, and 1 large - approximately 26.5 W x 7 D X 4 H) drawers Rinsing system for work surface with temperature and flow control Under shelf lighting for work space Faucet with foot pedal Cabinet doors Vendor is to provide a copy of equipment operator documentation either in paper or electronic format. The equipment models being offered shall be in current production as of the date this offer is submitted. For purposes of this solicitation, current product shall mean that the grossing station is being offered as new equipment. Discontinued models that are only being made available as remanufactured equipment are not acceptable. Refurbished, used or current in house equipment is not acceptable. Equipment Warranty All of the equipment should come with a 1 year warranty and include any and all preventative maintenance services recommended by the original equipment manufacturer during that warranty period. Deinstallation of old equipment and Installation of New Equipment The vendor shall remove 3 existing grossing stations at Minneapolis and 1 existing grossing station each at Omaha (NWI), Fargo, Central Iowa, and Iowa City. The lab will be responsible for decontaminating the grossing station and the vendor shall dismantle and take the equipment to the loading dock. The VA will be responsible for disposable of the equipment. The vendor will be responsible for fully installing the equipment and then testing for correct function. The vendor will ensure the grossing station air flow/ventilation is functioning properly after installation by having it certified. Training The vendor shall provide at least 1 day of onsite training for up to 8 people. This should be offered over at least 2 different shifts if needed by the lab. Integrations: Must integrate with each facilities HVAC system. No other integrations this equipment will not be connected to the network. Schedule of Deliverables: All equipment and supplies shall be delivered to the following VA medical centers. Equipment shall be delivered within 60 days of receipt of an order. Deliveries shall be made to: VA Central Iowa Health Care System 3600 30th St, Des Moines, IA 50310 VA Iowa City Health Care System 601 Highway 6 West, Iowa City, IA 52246-2209 VA Minneapolis Health Care System 1 Veterans Dr, Minneapolis, MN 55417 VA Nebraska-Western Iowa Health Care System 4101 Woolworth Ave, Omaha, NE 68105 VA Fargo Health Care System 2101 Elm St NE, Fargo, ND 58102 Delivery times: Between 8:00AM and 3:30PM, Monday-Friday except Federal Holidays. All deliveries shall be accompanied by a delivery ticket or sales slip which shall contain: Vendor s name Purchase order number Date of order Date of delivery Itemized list of products furnished including product description and quantity shipped. Certificates of Performance Company shall provide certificates of performance shipped stating compliance with your company s standards and CLSI (formerly NCCLS) standards where they exist. Recalled and Defective Products The contractor will immediately notify the Contracting Officer of any recalls of product or other important safety issues. As appropriate, the Contractor will replace and/or reimburse recalled/defective products at no cost to the Government. The Contractor may be liable for costs of processing recalls, i.e. administrative and clinical services to replace recalled/defective products. 

<!-- mobian-agent-ad sponsored="true" id="c830b7da-3291-43b1-9106-126be6cafd9e" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/48285630794d4b9397ae240da367fec7/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/87415a69ef2e4190ab584f4f604ff48c/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fadbe3b8289949edaa85db79d518d958/download)

[Source notice](https://sam.gov/workspace/contract/opp/9886d6612a6e45f4b233726c52945e4a/view)

[More from United States Department of Veterans Affairs posted in September 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-09)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515--VISN 23 Bio Safety Cabinets/Grossing Stations - Multiple Locations","description":"Statement of Work VISN 23 Grossing Station/BioSafety Cabinet Replacement Procurement Background: Several sites in VISN 23 are in need of replacing their current grossing stations in the Histology Laboratories. These grossing stations have reached the end of their life expectancy and we have begun to see an increase in the stations experiencing issues that require a service call. The increased downtime of these machines greatly impacts the speed and efficiency of the labs throughout the VISN in performing specimen examination. Additionally, the labs are seeking a newer model of grossing station which has additional features that would increase the speed, efficiency, and safety of the staff performing specimen examinations. Purpose of Project: Replace 8 grossing stations throughout VISN 23. Specifically 4 in Minneapolis and 1 each in Omaha (NWI), Fargo, Central Iowa, and Iowa City. Each of these sites have grossing stations that are past their life expectancy and are experiencing an increase in service calls. Statement of Work Description of Work: The vendor will provide the following quantities of grossing stations with the following features as required by site: Minneapolis QTY 4 Grossing Stations no larger than 60 inches long to fit into existing space Right hand sink Air Flow Detection with monitoring system Adjustable lighting Air Filtration System to prevent dust \u0026 debris build up Ventilation system Dual 8 (or comparable) duct stubs for in-house ventilation Hot/Cold Hand Sprayer Mechanism for mounting of monitor \u0026 keyboard arms Pegboard (or comparable) for mounting of accessories Include dye bottle holder Include large shelf approximately 14 L x 8 D x 2 H Include small shelf approximately 7 L x 8 D x 2 H Include bin for paper towels/c-fold gloves Include magnetic toolbar (or comparable) Two (2) GFCI receptacles, one (1) each with continuous power Work surface with interchangeable workflow components One (1) work surface perforated grid plate (or comparable) One (1) work surface dissecting board (or comparable) Mechanism for cord management 1/2 Hp. Disposal (or comparable) Magnetic instrument bar (or comparable) One (1) large and one (1) small organizer bin Mechanism for anchoring points Touchscreen monitor (or comparable) Monitor/keyboard mounting column Dual gooseneck LED task light (or comparable) At least 3 (2 small approximately 6 W x W 7 D x 4 H and 1 large approximately 26.5 W x 7 D X 4 H)) drawers per grossing station Rinsing system for work surface with temperature and flow control Formalin collection system Faucet with foot pedal control Omaha (NWI) QTY 1 Grossing Station no larger than 60 inches long to fit into existing space Right hand sink Air Flow Detection with monitoring system Adjustable lighting Air Filtration System to prevent dust \u0026 debris build up Ventilation system Dual 8 (or comparable) duct stubs for in-house ventilation Hot/Cold Hand Sprayer Mechnanism for mounting of monitor \u0026 keyboard arms Pegboard (or comparable) for mounting of accessories Include large shelf approximately 14 L x 8 D x 2 H Two (2) GFCI receptacles, one (1) each with continuous power Work surface with interchangeable workflow components One (1) work surface perforated grid plate (or comparable) One (1) work surface dissecting board (or comparable) Mechanism for cord management 1/2 Hp. Disposal (or comparable) Magnetic instrument bar (or comparable) One (1) large and one (1) small organizer bin Mechanism for anchoring points Touchscreen monitor (or comparable) Formalin collection system Hands free infared faucet Cabinet doors Fargo QTY 1 Grossing Station no larger than 60 inches long to fit into existing space Right hand sink Air Flow Detection with monitoring system Adjustable lighting Air Filtration System to prevent dust \u0026 debris build up Ventilation system Dual 8 (or comparable) duct stubs for in-house ventilation Hot/Cold Hand Sprayer Mechanism for mounting of monitor \u0026 keyboard arms Pegboard (or comparable) for mounting of accessories Include dye bottle holder Include large shelf approximately 14 L x 8 D x 2 H Include small shelf approximately 7 L x 8 D x 2 H Include bin for paper towels/c-fold gloves Include requisition holder should fit 8.5 x 11 requisitions Two (2) GFCI receptacles, one (1) each with continuous power Work surface with interchangeable workflow components One (1) work surface perforated grid plate (or comparable) One (1) work surface dissecting board (or comparable) Mechanism for cord management 1/2 Hp. Disposal (or comparable) Magnetic instrument bar (or comparable) One (1) large and one (1) small organizer bin Mechanism for anchoring points Touchscreen monitor (or comparable) Monitor/keyboard mounting column Single gooseneck LED task light (or comparable) At least 2 small approximately 6 W x W 7 D x 4 H drawer Rinsing system for work surface with temperature and flow control Formalin collection system Faucet with foot pedal control Central Iowa QTY 1 Grossing Station no larger than...","url":"https://matchawards.com/department_of_veterans_affairs/posts/115156421636158302","identifier":"36C26325Q1095","category":"339112 - Surgical and Medical Instrument Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2025-11-28","availabilityEnds":"2025-12-12","validThrough":"2025-12-12T23:59:59-05:00","sameAs":"https://sam.gov/workspace/contract/opp/9886d6612a6e45f4b233726c52945e4a/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

