<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/115116715840626273" -->

---
title: J041--Chiller Plant Maintenance - Louis Stokes… (36C25026Q0018) | Closed - MatchAwards
description: J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC. United States Department of Veterans Affairs. Solicitation 36C25026Q0018. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Deadline 2025-09-12. Sources Sought...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/115116715840626273
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J041--Chiller Plant Maintenance - Louis Stokes… (36C25026Q0018) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/115116715840626273
og:description: J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC. United States Department of Veterans Affairs. Solicitation 36C25026Q0018. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Deadline 2025-09-12. Sources Sought...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC

Status

Closed, the response deadline passed on Sep 12, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

DAYTON, USA

Notice type

Sources Sought

Solicitation number

36C25026Q0018

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Posted

2025-08-29

Deadline

2025-09-12

Place of performance

Cleveland, Ohio 44106-1702, UNITED STATES

## Description

Sources Sought Notice Page 4 of 4 \*= Required Field Sources Sought Notice Page 1 of 4 Department of Veterans Affairs Sources Sought Notice Chiller Plant Maintenance Louis Stokes Cleveland VA Medical Center This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought. The Department of Veterans Affairs (VA), VA Healthcare System, Network Contracting Office (NCO) 10, on behalf of Louis Stokes Cleveland VA Medical Center in Cleveland, Ohio, is conducting market research through this sources sought notice to seek sources that can provide Chiller Plant Maintenance and Services for the Louis Stokes Cleveland VA Medical Center. The NAICS Code for this acquisition is 811310, size standard of $12,500,000\. The product service code is J041\. The contracting office is contemplating award of a Firm-Fixed-Price contract for this service. This Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Pursuant to FAR Part 10, Market Research, the purpose of this notice is to determine if sources capable of satisfying the agency's requirements exists and to determine the commercial practices of company's engaged in providing the needed service. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action. This is a "REQUEST FOR INFORMATION" only. Requests for a solicitation will not receive a response. DESCRIPTION The Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors. GENERAL REQUIREMENTS Please provide the requested information with any responses: 1\. Company Name and POC information. 2\. SAM.gov UEI number. 3\. GSA contract number if these services are offered on Federal Supply Schedule. 4\. Socioeconomic category (SDVOSB, VOSB, WOSB, 8a, Small Business or Large Business). If this contract is set-aside, it will be subject to the Limitations on Subcontracting rules per FAR 52.219-14, 13 CFR 125.6 and VAAR 852.219-75\. 5\. Please provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. 6\. Statement ensuring any licenses, insurances, training, certifications, or special accommodations necessary to perform this task will be met. If there are specific requirements, please provide rationale. 7\. Any questions, comments, or concerns, that may otherwise assist us. RESPONSE COMMITMENT Please send all inquiries to: chad.kemper@va.gov. Phone calls will not be accepted. Eligibility in participating in a future acquisition does not depend upon a response to this notice. ?.## STATEMENT OF WORK (SOW) Contract Title Chiller Plant Maintenance Background The Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors. Scope The vendor shall supply all labor, materials, equipment, clean up, transportation, and supervision necessary to perform all full-service, on-site maintenance, repairs, and replacement as scheduled and needed to the chiller plant chillers, cooling towers, pumps and any auxiliary equipment located at Louis Stokes Cleveland VA Medical Center to maintain the equipment in full operational status. This will include all equipment listed in Parts One, Two, Three, Four and Five. Vendor will have documented certified technicians and the ability to provide repair and replacement parts. The Louis Stokes Cleveland VA Medical Center is expecting to add an additional/new chiller during Fiscal Year 2026\. The new Chiller will be added to the scope of the contract. Specific Tasks See equipment list and maintenance description below: 5.1\. Task 1: Part One - Centrifugal Chillers NUMBER MFG MODEL TONS/ OUTPUT CH-I TRANE CVHF128NA 1,200 4160V CH-2 TRANE CVHF128NA 1,200 4160V CH-3 TRANE CVHF128NA 1 ,200 4160V CH-4 TRANE CVHF1280 1,200 480V CH-5 TRANE CVHF13DFA 1,200 480V 5.1.1\. Requirements for Centrifugal Chillers and Rotary Chillers: ANNUAL Maintenance Once a year, thorough preventative maintenance will be performed, including the following: Furnish oil filters and gaskets as required. Pressure test as required using system pressure. Repair any leaks. Provide refrigerant leak reports to owners as required by EPA guidelines. Detailed inspection of purge system and thorough cleaning of purge compressor, purge oil separator, purge drum. Detailed inspection of purge system to include control circuit diagnostics, purge tank checkout and water removal, replace filter drier cores and clean the air-cooled condenser, if applicable. Check the condition of contacts for wear, pitting, etc. Check and calibrate safety controls, including all transmitters, flow meters, and all other monitoring devices. Meg compressor motor and oil pump. Check main starters and perform recommended testing (this includes all the chillers). Check the main starters, tighten all starter terminals, and check contacts for wear. Check overloads. Tighten motor terminals and control panel terminals. Clean oil strainer, replace filter and gasket where required. Tighten oil heater leads. Check operation of vane position. Take oil sample and have analyzed for acid, moisture, and wear metal content. Change oil when so indicated by oil analysis unless done on annual schedule. Provide yearly recommended maintenance on refrigerant monitor along with calibration test, if applicable. Report any noted deficiencies. Monthly Maintenance: Monthly inspections to be made during the operating season, to include the following: Adjust operating and safety controls. Record settings. Complete operating log of temperatures, pressures, and voltages. Change oil in purge vacuum pumps when required. Check operation of purge system. Check operation of control circuit. Check operating of lubricant system including oil pump and oil pressure regulator. Check operation of motor and starter. Check customer log with the operator, discuss operation of the machine generally. Report to operator any uncorrected deficiencies noted. Make operating log of temperatures, pressures, voltages, amperages, etc. Check and adjust operating and safety controls. Check operation of oil reservoir sump heater. Check oil level and add as required. Check operation of control circuit. Check operating log with operator, discuss operation of the machine generally. Check operation of motor and starter. Seasonal Start Up The contractor will advise regarding the start of the month. 1\. Test motor (Meg). 2\. Start the machine, check controls, and calibrate. 3\. Complete operating log and record settings monthly. 4\. Check refrigerant and oil levels. 5\. Check purge operation. 6\. Check starter operation, voltage, and current. Set up operating log with operator, instruct, and advise troubleshooting techniques. Analysis Services Various diagnostic tests are to be performed depending on equipment duty and type. Reports with interpretation and recommendations are to be included. 1\. Oil sample and analysis for wear metals, acid content, and moisture. Sample to be taken two (2) times per year. 2\. Refrigerant analysis for acid and moisture content (as required). Annual Operator Training Training of operators or building engineers on the equipment covered, if required. 1\. Eight (8) hours of training per year for every boiler plant employee, up to 16 employees. 2\. Any un-utilized training costs will be reimbursed. Parts Replacement All parts needed to replace failed components on non-covered equipment will be offered at a discount percentage (30%). This does not include materials or components, such as refrigerant, oil, and other materials the contractor will provide to perform maintenance and repairs as emergencies or scheduled under annual maintenance, monthly maintenance, seasonal start up and analysis services. Any parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding. Written Reports: Provided to customer representative following each regular inspection or emergency call. 5.2\. Task 2: Part Two Trace Automation & Controls 5.2.1\. Requirements for Tracer Automation Equipment Main Plant and Process Chiller Plant: A. Contractor will provide full-service coverage for regular systematic maintenance and parts, materials and labor for repairs, including all software support, defects in materials or manufacture, or due to normal wear and tear. B. Contractor will provide and install any new operational software and/or graphics with the latest revisions over the course of the contract. C. Unit maintenance and repair/replacement of PCs, Monitors, UPSs and associated equipment will be the liability of the contractor over the duration of the contract with no additional cost. D. Scheduled maintenance includes diagnosis of system performance, inspection, cleaning, adjustments, and other procedures as required by specifications according to system use and configuration. Semi-Annual Preventative Maintenance Maintenance/repair or replacement if required of the Building Automation Systems. Includes all operated valves, programming panels, BCU s, Tracer Output/Input panels and workstations associated with Energy Center equipment and operations, to include the following: Master Station Check the operating environment and clean the console. Check and clean the central processing unit and record input voltage. 2\. If necessitated by operational difficulties, run system diagnostics. Contractor will provide and install any new operational software and/or graphics with the most current version at no cost over the course of the contract. 3\. Clean and maintain BCU modules in both the Penthouse and Ambulatory Care. 4\. Check and clean CRTs and Printers. 5\. Perform complete system backup. 6\. Remote Stations and Field Hardware: Verify regulated power assembly and battery voltages, adjust as required. Inspect cabinet at earth ground potential. Verify proper system electrical ground isolation. Inspect interconnecting cables and electrical connections. Via terminal exercise-controlled devices with manual command functions and verify proper response of connected field hardware. Check for alarms and overrides. Note specific alarm and override conditions for review with the owner personnel. Clean external surfaces of the panel enclosure and associated field equipment units. Review system performance with Medical Centers designated contact. Discuss specific parameter changes implemented as required. Inspect interior surfaces and components of the panel enclosure and associated field equipment. Ensure all mounted devices add plug in components are securely in place. Evaluate binary and analog points for proper operation and reporting Perform a general performance review of all points. Check individual critical points. Determine new or revised calibration coefficients as required. Record any parameter values which are different than those shown on program listings. ANNUAL OPERATOR TRAINING The contractor will provide up to eight (8) hours of Tracer Summit on-site customer training, if requested. WRITTEN REPORTS Provided written reports to COR following each regular inspection or emergency call. 5.3\. Task 3: Part Three Chill Water/Tower Water Pumps, & Drives NUMBER MFG MODEL SERVICE CWP-I WEINMAN 444TT CHILLED WATER 2400GPM 150HP CWP-2 WEINMAN 444TT CHILLED WATER 2400GPM 150HP CWP-3 WEINMAN 444TT CHILLED WATER 2400GPM 150HP CWP-4 WEINMAN 444TT CHILLED WATER 2400GPM 150HP CWP-5 PACO 444TT CHILLED WATER 2400GPM 150HP CWP-6 PACO 444TT CHILLED WATER 2400GPM 150HP VFD CWP-1 DANFOSS/ GRAHAM VLT6000H190 CHILLED WATER 480V VFD CWP-2 DANFOSS/ GRAHAM VLT6000H190 CHILLED WATER 480V VFD CWP-3 DANFOSS/ GRAHAM VLT6000H190 CHILLED WATER 480V VFD CWP-4 HONEYWELL SMART VFD HVFDSD3C1500G100 CHILLED WATER 480V VFD CWP-5 EATON CFX9000 CHILLED WATER 480V VFD CWP-6 EATON SVX9000 CHILLED WATER 480V TWP-I WEINMAN 12L2 TOWER WATER 3600GPM 100HP TWP-2 WEINMAN 12102 TOWER WATER 3600GPM 100HP TWP-3 WEINMAN 12L2 TOWER WATER 3600GPM 100HP TWP-4 WEINMAN 12L2 TOWER WATER 3600GPM 100HP TWP-5 PACO KP8012-56 TOWER WATER 3600GPM 100HP TWP-6 PACO 8012 TOWER WATER 3600GPM 100HP VFD-TWP-1 DANFOSS/ GRAHAM MCD3075 TOWER WATER 480V VFD-TWP-2 DANFOSS/ GRAHAM MCD3075 TOWER WATER 480V VFD-TWP-3 DANFOSS/ GRAHAM MCD3075 TOWER WATER 480V VFD-TWP-4 EATON SVX9000 TOWER WATER 480V VFD-TWP-5 EATON CFX9000 TOWER PUMP 480V VFD-TWP-6 EATON SVX9000 TOWER PUMP 480V 5.3.1\. Requirements for all Chill-Water, Tower/Condenser Water Pumps: Monthly Maintenance Monthly inspections to be made during the operating season, to include the following: 1\. Lubricate pump bearings per manufacturer s recommendations. 2\. Lubricate motor bearings per manufacturer s recommendations. 3\. Check the suction and discharge pressures. 4\. Check packing or mechanical seal and adjust as necessary. 5\. Check motor voltage and amperage. SEASONAL START UP 1\. Clean pump strainers. 2\. Lubricate pump bearings per manufacturer s recommendations. 3\. Lubricate motor bearings per manufacturer s recommendations. 4\. Tighten all nuts and bolts. Check motor mounts and vibration pads. 5\. Visually check pump alignment and coupling. 6\. Check motor operating conditions. 7\. Inspect electrical connections and contractors. 8\. check mechanical seals or pump packing. 9\. Operate pumps and check efficiency. PARTS REPLACEMENT All parts or failed components of the equipment needed to be replaced will be provided by the vendor/contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under monthly maintenance and seasonal start up. Any parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding. WRITTEN REPORTS Provided to customer representative following each regular inspection or emergency call. 5.3.2\. Requirements for Adjustable or Variable Frequency Drives ANNUAL MAINTENANCE: Once a year a thorough preventative maintenance schedule will be performed including the following: Base year initial base line reading of all VFDs will be provided in written report and subsequent yearly reports will be provided. Remove all debris, dust, or residue material from the drive enclosure. Clean printed circuit boards with an approved cleaner or small brush. Inspect for any lose plugs or ribbon cables. Inspect for any damaged or missing items. Look for any overheated or charred components. Look for discolored components, smudges, or smoke residue. Tighten all connections. Inspect cooling fans for proper operation and change filters quarterly. Check the continuity of all control circuit fuses. Perform diode test of the diode bridges. Perform continuity check of Debus and bus caps. Perform diode test of transistors. Check and record AC line voltage. Check and record motor output lead voltage for balanced supply. Check and record Debus voltage. Compare data with previous tests to expose degradation of components. PART REPLACEMENT All parts needed to replace failed components of the equipment will be provided by the contractor. This includes all materials or components, such as refrigerant, oil, and other materials the Contractor will provide to perform maintenance and repairs as scheduled under annual maintenance. Any parts, repairs, and/or maintenance outside of the standard maintenance that will require additional charges must be discussed with the COR and CO prior to any work being done. All additional charges will require a new purchase order to be issued. Work done without a purchase order will be assumed to be covered by the Vendor. Only the CO can obligate funding. 5.4\. Task 4: Part Four Cooling Towers, Cooling Tower Fan Drives, Semi-Annual Tower Cleaning, & Disinfection NUMBER MFG MODEL TONS MOTOR CT-I EVAPCO REP 224-018 1200TONS 2CELLS CT-2 EVAPCO REP 224-018 1200TONS 2CELLS CT-3 EVAPCO REP 224-018 1200TONS 2CELLS CT-4 EVAPCO REP224-118 1200TONS 2CELLS CT-5 EVAPCO AT224-118 1200TONS 2CELLS VFD-CT-I HONEYWELL SMART VFD HVFOSD306005100 COOLING TOWER FANS 30 60HZ VFD-CT-2 DANFOSS/ GRAHAM VLT6000 COOLING TOWER FANS 30 60HZ VFD-CT-3 DANFOSS/ GRAHAM VLT6000 COOLING TOWER FANS 2 @ 30EA 60HZ VFD-CT-4B EATON CFX9000 COOLING TOWER FAN 1 30HZ VFD-CT4A HONEYWELL NXS0300A1001 COOLING TOWER FAN 1 30HZ VFD-CT-5 EATON SVX9000 FANS 2 60HZ 5.4.1\. Requirements for Cooling Towers/Fluid Coolers MONTHLY MAINTENANCE Monthly inspections are to be made during the operating season, to include the following: Inspect the fan, motor, and belt. Check the oil level and add oil as needed. Check the intake strainer on cooling towers. Check operating conditions. Adjust as required. CLEANING & DISINFECTION PROCESS To be completed in early Spring (March/April) and late Fall (October/November) dependent on weather conditions and scheduled through the COR. The following stages highlight the general approach for cleaning and disinfection of cooling water systems. Certain modifications may be required depending on system access, design, operation or the like. All stages in the clean and disinfection process shall require assistance from the Customer such as the operation engineer who is familiar with the system. All supplies and PPE will be contractor supplied. Proper LOTO will be utilized as needed. Stage I Pre-Clean Disinfection for the destruction of biofilms and pathogens All cooling tower fans must be shut OFF and proper LOTO procedures in place prior to start of process, and all recirculation pumps must be ON. The system is disinfected using an oxidizing biocide such as chlorine or an equivalent chemistry. A bio dispersant may also be added to help remove organic deposits and enhance disinfection. Stage II Mechanical Cleaning for surface sanitation and removal of deposits Each system cell and/or sump is isolated and drain 

<!-- mobian-agent-ad sponsored="true" id="4a07ef2d-1e45-4587-b372-27ea15d38924" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a3b4cb1ce15e4e82891ea39e3a46f58a/download)

[Source notice](https://sam.gov/opp/1b47eb37f6cd41f99a3ea9641897ba0e/view)

[More from United States Department of Veterans Affairs posted in August 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-08)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J041--Chiller Plant Maintenance - Louis Stokes Cleveland VAMC","description":"Sources Sought Notice Page 4 of 4 *= Required Field Sources Sought Notice Page 1 of 4 Department of Veterans Affairs Sources Sought Notice Chiller Plant Maintenance Louis Stokes Cleveland VA Medical Center This is a Sources Sought notice and not a request for quotes. This request is solely for the purpose of conducting market research to enhance VHA s understanding of the market s offered products, services and capabilities. The Government will not pay any costs for responses submitted in response to this Sources Sought. The Department of Veterans Affairs (VA), VA Healthcare System, Network Contracting Office (NCO) 10, on behalf of Louis Stokes Cleveland VA Medical Center in Cleveland, Ohio, is conducting market research through this sources sought notice to seek sources that can provide Chiller Plant Maintenance and Services for the Louis Stokes Cleveland VA Medical Center. The NAICS Code for this acquisition is 811310, size standard of $12,500,000. The product service code is J041. The contracting office is contemplating award of a Firm-Fixed-Price contract for this service. This Sources Sought notice provides an opportunity for respondents to submit their notice of ability, and their available services in response to the requirement described below. Vendors are being invited to submit information relative to their potential of fulfilling the requirement below, in the form of a capability response that addresses the specific requirement identified in this Sources Sought. Pursuant to FAR Part 10, Market Research, the purpose of this notice is to determine if sources capable of satisfying the agency's requirements exists and to determine the commercial practices of company's engaged in providing the needed service. Pursuant to FAR Part 6 and FAR Part 19, competition and set-aside decisions may be based on the results of this market research. This notice in no way obligates the Government to any further action. This is a \"REQUEST FOR INFORMATION\" only. Requests for a solicitation will not receive a response. DESCRIPTION The Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors. GENERAL REQUIREMENTS Please provide the requested information with any responses: 1. Company Name and POC information. 2. SAM.gov UEI number. 3. GSA contract number if these services are offered on Federal Supply Schedule. 4. Socioeconomic category (SDVOSB, VOSB, WOSB, 8a, Small Business or Large Business). If this contract is set-aside, it will be subject to the Limitations on Subcontracting rules per FAR 52.219-14, 13 CFR 125.6 and VAAR 852.219-75. 5. Please provide a capability statement that addresses the organization s qualifications and ability to perform as a contractor for the work described below. 6. Statement ensuring any licenses, insurances, training, certifications, or special accommodations necessary to perform this task will be met. If there are specific requirements, please provide rationale. 7. Any questions, comments, or concerns, that may otherwise assist us. RESPONSE COMMITMENT Please send all inquiries to: chad.kemper@va.gov. Phone calls will not be accepted. Eligibility in participating in a future acquisition does not depend upon a response to this notice. ?.## STATEMENT OF WORK (SOW) Contract Title Chiller Plant Maintenance Background The Louis Stokes VA Medical Center located at 10701 East Blvd, Cleveland, Ohio 44106 is seeking a qualified contractor to provide all labor, materials, equipment, transportation, and supervision necessary to provide full-service, on-site Chiller Plant Maintenance to maintain and service all chillers, pumps, cooling towers, VFDs, and building automation controls necessary to cool and de-humidify the Medical Center for the health and safety of our patients, staff, medical equipment and visitors. Scope The vendor shall supply all labor, materials, equipment, clean up, transportation, and supervision necessary to perform all full-service, on-site maintenance, repairs, and replacement as scheduled and needed to the chiller plant chillers, cooling towers, pumps and any auxiliary equipment located at Louis Stokes Cleveland VA Medical Center to maintain the equipment in full operational status. This will include all equipment listed in Parts One, Two, Three, Four and Five. Vendor will have documented certified technicians and the ability to provide repair and replacement parts. The Louis Stokes Cleveland VA Medical Center is expecting to add an additional/new chiller during Fiscal Year 2026. The new Chiller will be added to the scope of the contract....","url":"https://matchawards.com/department_of_veterans_affairs/posts/115116715840626273","identifier":"36C25026Q0018","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2025-08-29","availabilityEnds":"2025-09-12","validThrough":"2025-09-12T23:59:59-04:00","areaServed":"Cleveland, Ohio 44106-1702, UNITED STATES","sameAs":"https://sam.gov/opp/1b47eb37f6cd41f99a3ea9641897ba0e/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"}]}
```

