<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/114669398561116379" -->

---
title: 6515--MRI CONTRAST INJECTOR NAME BRAND: GUERBET… (36C25525Q0424) | Closed - MatchAwards
description: 6515--MRI CONTRAST INJECTOR    NAME BRAND: GUERBET OPTISTAR ELITE. United States Department of Veterans Affairs. Solicitation 36C25525Q0424. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2025-06-18. STATEMENT OF WORK Description of Use: For administering contrast...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/114669398561116379
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6515--MRI CONTRAST INJECTOR NAME BRAND: GUERBET… (36C25525Q0424) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/114669398561116379
og:description: 6515--MRI CONTRAST INJECTOR    NAME BRAND: GUERBET OPTISTAR ELITE. United States Department of Veterans Affairs. Solicitation 36C25525Q0424. NAICS 339112 - Surgical and Medical Instrument Manufacturing. Deadline 2025-06-18. STATEMENT OF WORK Description of Use: For administering contrast...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6515--MRI CONTRAST INJECTOR NAME BRAND: GUERBET OPTISTAR ELITE

Status

Closed, the response deadline passed on Jun 18, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Sources Sought

Solicitation number

36C25525Q0424

NAICS

[339112 - Surgical and Medical Instrument Manufacturing](/groups/582)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2025-06-11

Deadline

2025-06-18

Place of performance

Marion, Illinois 62959, UNITED STATES

## Description

STATEMENT OF WORK Description of Use: For administering contrast injection of diagnostic Magnetic Resonance Imaging (MRI) examination in the Marion IL VA Healthcare System MRI Suite within Imaging Service. Replacement of end-of-life cycle Magnetic Resonance (MR) dual syringe contrast media and flush solution injection system to be used in conjunction with GE Signa Artist 1.5 MRI Scanner. Brand Name, Guerbet OptiStarÂ® Elite required for compatibility with prefilled syringes used by MRI Service. Date of manufacture must not be greater than one (1) year before the purchase date. The equipment must not be used or refurbished. Training and installation must be included. Provide Trade-In for existing Guerbet OptiStarÂ® Must be compatible with and/or capable of : Interfacing with GE Signa Artist 1.5 MRI Scanner Prefilled Syringes DOTAREM contrast NDC: 67684-3001-02 and saline syringes NDC: 00019-1188-81 Minimum Technical Specification: To be used with prefilled syringe and vials Product will be mobile with installation of rolling pedestal design Syringe compatibility and Flow Rate: Side A: 60 mL syringes at 0.1 10.0 mL/sec; 10-, 15-, 20-, and 30-mL syringes at 0.1 0.8 mL/sec Side B: 60 mL single-use disposable syringes at 0.1 0.8 mL/sec; 50- and 125- mL prefilled saline syringes\* at 0.1 0.8 mL/sec (\*must fit cannula down to 6mm) Pressure Limit: 60 mL empty syringes: 150 psi 10-, 15-, 20-, and 30-mL prefilled syringes: 200 psi\* 50- and 125-mL prefilled saline syringes: 150 psi\* Volume: Side A: 10-, 15-, and 20-mL syringes: 1 mL to 20 mL; 30- and 60-mL syringes: to installed syringe size. Side B: 60 mL syringes: 1 mL to installed syringe size; 50- and 125-mL prefilled saline syringes\*: 1 mL to installed syringe size Scan Delay: 0-60 seconds Inject Delay: 0-300 seconds Number of Phases: 6 including Timing BolusÂ® feature Number of Programs: 40 Inject History: Last 48 injected protocols MR Compatibility: Up to 3 Tesla Patency test mode option to check vein prior to injection (dedicated powerhead key) Service contract for system maintenance with annual inspection (this service will be for a base plus four (4) option years). Optional/Value Added Features: IV fluid drip option for continuous IV-line patency throughout the examination. Timing Bolus: Test injection to confirm protocol Pressure: Automatic sensing & setting to ensure best security Direct power supply (e.g. not reliant on batteries) Touchscreen console with clearly identifiable color command keys Clear indicators & status line Remote begin and end injection options Programable injection protocol storage: up to 6 phases with Timing BolusÂ®, even more with injection & phase delays Powerhead keys 

<!-- mobian-agent-ad sponsored="true" id="b2ff2efa-a479-44c9-8105-12bd85c981d6" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e76b495d209e456fafc488a62e992870/download)

[Source notice](https://sam.gov/opp/257eee512eca48a3964422ee624f7cd9/view)

[More from United States Department of Veterans Affairs posted in June 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-06)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6515--MRI CONTRAST INJECTOR    NAME BRAND: GUERBET OPTISTAR ELITE","description":"STATEMENT OF WORK Description of Use: For administering contrast injection of diagnostic Magnetic Resonance Imaging (MRI) examination in the Marion IL VA Healthcare System MRI Suite within Imaging Service. Replacement of end-of-life cycle Magnetic Resonance (MR) dual syringe contrast media and flush solution injection system to be used in conjunction with GE Signa Artist 1.5 MRI Scanner. Brand Name, Guerbet OptiStarÂ® Elite required for compatibility with prefilled syringes used by MRI Service. Date of manufacture must not be greater than one (1) year before the purchase date. The equipment must not be used or refurbished. Training and installation must be included. Provide Trade-In for existing Guerbet OptiStarÂ® Must be compatible with and/or capable of : Interfacing with GE Signa Artist 1.5 MRI Scanner Prefilled Syringes DOTAREM contrast NDC: 67684-3001-02 and saline syringes NDC: 00019-1188-81 Minimum Technical Specification: To be used with prefilled syringe and vials Product will be mobile with installation of rolling pedestal design Syringe compatibility and Flow Rate: Side A: 60 mL syringes at 0.1 10.0 mL/sec; 10-, 15-, 20-, and 30-mL syringes at 0.1 0.8 mL/sec Side B: 60 mL single-use disposable syringes at 0.1 0.8 mL/sec; 50- and 125- mL prefilled saline syringes* at 0.1 0.8 mL/sec (*must fit cannula down to 6mm) Pressure Limit: 60 mL empty syringes: 150 psi 10-, 15-, 20-, and 30-mL prefilled syringes: 200 psi* 50- and 125-mL prefilled saline syringes: 150 psi* Volume: Side A: 10-, 15-, and 20-mL syringes: 1 mL to 20 mL; 30- and 60-mL syringes: to installed syringe size. Side B: 60 mL syringes: 1 mL to installed syringe size; 50- and 125-mL prefilled saline syringes*: 1 mL to installed syringe size Scan Delay: 0-60 seconds Inject Delay: 0-300 seconds Number of Phases: 6 including Timing BolusÂ® feature Number of Programs: 40 Inject History: Last 48 injected protocols MR Compatibility: Up to 3 Tesla Patency test mode option to check vein prior to injection (dedicated powerhead key) Service contract for system maintenance with annual inspection (this service will be for a base plus four (4) option years). Optional/Value Added Features: IV fluid drip option for continuous IV-line patency throughout the examination. Timing Bolus: Test injection to confirm protocol Pressure: Automatic sensing \u0026 setting to ensure best security Direct power supply (e.g. not reliant on batteries) Touchscreen console with clearly identifiable color command keys Clear indicators \u0026 status line Remote begin and end injection options Programable injection protocol storage: up to 6 phases with Timing BolusÂ®, even more with injection \u0026 phase delays Powerhead keys","url":"https://matchawards.com/department_of_veterans_affairs/posts/114669398561116379","identifier":"36C25525Q0424","category":"339112 - Surgical and Medical Instrument Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2025-06-11","availabilityEnds":"2025-06-18","validThrough":"2025-06-18T23:59:59-04:00","areaServed":"Marion, Illinois 62959, UNITED STATES","sameAs":"https://sam.gov/opp/257eee512eca48a3964422ee624f7cd9/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```