<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/114478667561703907" -->

---
title: Thyroid Uptake System, Poplar Bluff, MO VAMC | Closed - MatchAwards
description: Thyroid Uptake System, Poplar Bluff, MO VAMC. United States Department of Veterans Affairs. Solicitation 36C25525Q0328. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. SDVOSB set-aside. Deadline 2025-05-16. STATEMENT OF REQUIREMENT A. GENERAL INFORMATION The Nuclear...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/114478667561703907
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Thyroid Uptake System, Poplar Bluff, MO VAMC | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/114478667561703907
og:description: Thyroid Uptake System, Poplar Bluff, MO VAMC. United States Department of Veterans Affairs. Solicitation 36C25525Q0328. NAICS 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing. SDVOSB set-aside. Deadline 2025-05-16. STATEMENT OF REQUIREMENT A. GENERAL INFORMATION The Nuclear...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Thyroid Uptake System, Poplar Bluff, MO VAMC

Status

Closed, the response deadline passed on May 16, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LEAVENWORTH, USA

Notice type

Solicitation

Solicitation number

36C25525Q0328

NAICS

[334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing](/groups/514)

PSC

6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2025-05-09

Deadline

2025-05-16

Place of performance

Poplar Bluff, Missouri 63901, UNITED STATES

## Description

STATEMENT OF REQUIREMENT  
A. GENERAL INFORMATION  
The Nuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software.  
Engineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated.  
B. SCOPE  
Delivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals, I-123, I-125 and I-131\. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files  
The Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists.  
The wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys. The system allows user to define an unlimited number of “Area” names and wipe “Locations” entered within the areas for testing and documentation. Each area may be designated as “restricted”, “unrestricted”, “package” or “sealed source”. The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options.  
The program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may  
also be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format.  
The application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable.  
The contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software.  
C. REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS  
Common Nomenclature: Medical Spectrometer Hardware  
Kind of material: ALL IN ONE Touch Screen Computer  
Electrical Data:  
Power: Low voltage transformer with hospital grade power cord and plug.  
Line Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker  
Dimensions, size, capacity:  
Minimum articulating arm with a minimum of 34-inch vertical range of travel with a minimum of 220-degree collimator rotation.  
Principles of operation:  
Multi-Channel Analyzer:  
Channels: 1024  
Spectral Resolution: FWHM 8%  
Count Rate: (Maximum) 150,000 cps for Tc-99m  
Count Rate Stability: 99%  
Gross Count Rate Linearity: Within 5% up to 150,000 cps  
Pulse Height Linearity: Within 2% (independent of detector)  
Detector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 μCi Cs-137 as the calibration source.  
Restrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half-life, name, efficiency and range.  
Intended use:  
Factory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window.  
Equipment with which the item is used, Job related tools:  
Probe: 2" x 2" Nal (Tl) integral line scintillation detector  
Other pertinent information that describes the item, material or service required:  
Uptake Stand:  
Dimensions:  
Arm down and retracted: 34" l x 26" w x 55" h (86.4 x 66 x 139.7 cm)  
Maximum Height: 60" (152.4 cm)  
Maximum Length: Arm Extended: 61" (154.9 cm)  
Collimated Shield: Flat field collimator meeting IAEA specifications  
Positioning: Distance bar and positioning light  
Casters: 4" Total locking  
Maximum weigh of 300 lbs.  
A maximum combined weight with Well Counter: 350 lbs.  
Power: Low voltage transformer with hospital grade power cord and plug.  
Line Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker  
OTHER UNIQUE REQUIREMENTS: Minimum of two-inch well container  
Compatibility with Existing Equipment: TRM Compliance with VA Directives  
WINDOWS 10 compatible or Newest Windows Version compliance with VHA standards.  
Must be DICOM compliance, Directives or IT Policies, Required.  
Coordination with On-going Construction Project (provide the project number): N/A  
Warranty: 1 year from date of receipt and verification of installation/operation. Two years part/labor warranty  
Training: Initial installation and launch training staff and service support  
Service and/or Maintenance: Preventive maintenance and training support, to include two Operating Manuals and two Service Manuals  
Safety/ISO/IT/BioMed/SPS & Other Departmental Compliance: Must meet Technical Reference Model (TRM) VA/BioMed Compliance.  
D. DELIVERY  
Contractor must deliver all components of the system within 30 days of award notice.  
Standard FOB Destination to:  
John J. Pershing VA Medical Center  
1500 North Westwood Blvd  
Poplar Bluff MO 63901  
Government-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI) N/A  
SECURITY N/A  
SPECIAL MATERIAL REQUIREMENT: Two Operator’s Manuals and two Service Manuals  
E. PLACE OF PERFORMANCE  
The system will be installed, serviced, and updated at the facility, John J. Pershing VAMC, Poplar Bluff, MO, Nuclear Medicine Department. Servicing, training, and support of personnel will be per stipulations on the final contract.

<!-- mobian-agent-ad sponsored="true" id="0b4600cc-e2a3-46f8-986f-59abe4c7b077" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a825ea5ba6ad4aeabd7d5d59b0f20fc5/download)

## Contacts

* Tywanna Sparks

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/c8aed55f45714c4ea51fe0d57b35e8cd/view)

[More from United States Department of Veterans Affairs posted in May 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-05)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Thyroid Uptake System, Poplar Bluff, MO VAMC","description":"STATEMENT OF REQUIREMENT A. GENERAL INFORMATION The Nuclear Medicine service at John J. Pershing VA Medical Center (VAMC) in Poplar Bluff, MO will better serve its Veterans by acquiring this Thyroid Uptake System with Well Counting System with 2 Inch Well Shielding, a multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. The system performs Uptake studies, wipe tests, and other user-defined tasks that are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software. Engineered for mobility, durability and operational efficiency, the unit handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Built-in menus follow conventionally established nuclear medicine procedures, providing step-by-step guidance throughout defined procedures. The system automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. User-defined uptake protocols can be initiated. B. SCOPE Delivery of the Thyroid Uptake system will allow a bioassay program for quick and efficient measurement of the staff thyroid burden for radiopharmaceuticals, I-123, I-125 and I-131. Measurement results can be reported in cpm, dpm, uCi, or Bq. Action levels may be set by the user for each isotope. System reporting facilitates single bioassay report, summary of multiple bioassays on an individual staff member, and summary report on multiple staff members. Reports are easily printed or saved as PDF files The Thyroid Uptake program supports multiple time-stamped uptake measurements, auto decay correction, user-defined uptake protocols, on-screen spectrum acquisition and analysis. The system provides reports that include normal ranges and allow notes/comments entered by the facility physician and technologists. The wipe test application automatically calculates net contamination levels and reports results in dpm, uCi and Bq. The program allows compliance with regulations for counting and reporting results of wipes taken for contamination surveys. The system allows user to define an unlimited number of “Area” names and wipe “Locations” entered within the areas for testing and documentation. Each area may be designated as “restricted”, “unrestricted”, “package” or “sealed source”. The user may specify count times, activity units, wide window, and individual isotopes and geometric efficiencies or simply utilize the wide range of factory default options. The program displays and stores the full spectrum with each wipe, automatically calculates net contamination levels and reports results in dpm, uCi or Bq. Wipes above the user defined trigger levels are easily identified. A detailed spectrum analysis may also be performed for any wipe to help identify isotopes causing contamination. Customized reports can be printed or saved in PDF format. The application specialist will provide training and guidance to ensure safe use of the equipment and the study and administration applications provided. The contractor will provide cybersecurity best practices information and training, when applicable. The contractor will provide application update to ensure information security in the current equipment and other factors that interconnects with the imaging system including the network, other current peripheral applications and other new tools and software that will be developed or installed to work with the current work station and imaging equipment hardware and software. C. REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS Common Nomenclature: Medical Spectrometer Hardware Kind of material: ALL IN ONE Touch Screen Computer Electrical Data: Power: Low voltage transformer with hospital grade power cord and plug. Line Voltage: 120 VAC, 60 Hz, 2 AMP circuit breaker; 230 VAC, 50 Hz, 1 AMP circuit breaker Dimensions, size, capacity: Minimum articulating arm with a minimum of 34-inch vertical range of travel with a minimum of 220-degree collimator rotation. Principles of operation: Multi-Channel Analyzer: Channels: 1024 Spectral Resolution: FWHM 8% Count Rate: (Maximum) 150,000 cps for Tc-99m Count Rate Stability: 99% Gross Count Rate Linearity: Within 5% up to 150,000 cps Pulse Height Linearity: Within 2% (independent of detector) Detector High Voltage Adjustment: Automatic adjustment for both probe and well; uses 10 μCi Cs-137 as the calibration source. Restrictive environmental conditions: User Set: Unlimited user defined Isotopes, setting ROI, half-life, name, efficiency and range. Intended use: Factory Programmed: Au-198, Ba-133, Co-57, Co-58, Co-60, Cr-51, Cs-137, F-18, Fe-59, Ga-67, Ga-68, Gd-153, Ge-68/Ga-68, Hg-197, I-123, I-125, I-131, In-111, Ir-192, K-42, Lu-177, Na-22, Na-24, Pd-103, Ra-223, Se-75, Sr-85, Tc-99m, Tc-99m/Tl-201, Tl-201, Yb-169, Wide Window. Equipment with which the item is used, Job related tools: Probe: 2\" x...","url":"https://matchawards.com/department_of_veterans_affairs/posts/114478667561703907","identifier":"36C25525Q0328","category":"334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2025-05-09","availabilityEnds":"2025-05-16","validThrough":"2025-05-16T23:59:59-04:00","areaServed":"Poplar Bluff, Missouri 63901, UNITED STATES","sameAs":"https://sam.gov/opp/c8aed55f45714c4ea51fe0d57b35e8cd/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```