ClickCease J047--Pneumatic Tube System Maintenance (36C24825Q0724) | Closed - MatchAwards

J047--Pneumatic Tube System Maintenance

Status
Closed, the response deadline passed on May 5, 2025
Agency
United States Department of Veterans Affairs
Office
TAMPA, USA
Notice type
Presolicitation
Solicitation number
36C24825Q0724
NAICS
811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
PSC
J047 - MAINT/REPAIR/REBUILD OF EQUIPMENT- PIPE, TUBING, HOSE, AND FITTINGS
Category
Industrial Products Install / Maintenance / Repair (5.5)
Posted
2025-04-25
Deadline
2025-05-05
Place of performance
Tampa,, Florida 33612, UNITED STATES

Description

2 | Page THIS IS NOT A SOLICITATION ANNOUNCEMENT. THIS IS A REQUEST FOR INFORMATION ONLY. This Request for Information (RFI) is intended for information and planning purposes only at this time; and shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs. Because this is a Request for Information announcement, no evaluation letters and/or results will be issued to the respondents. No solicitation exists. Therefore, do not request a copy of a solicitation. The Department of Veterans Affairs (VA), VISN 8, Network Contracting Office 8 (NCO 8), is seeking information and potential qualified sources capable of meeting the following minimum requirements and salient characteristics below for Pneumatic Tube Delivery System Preventative Maintenance Service. Requirements SCOPE: Service technicians shall perform two (2) site visit(s) per year to inspect, clean, adjust, calibrate and lubricate your pneumatic tube system. The labor necessary to replace worn or defective parts shall be included. Equipment maintenance is performed as described and recommended in accordance with the Service Manual for your system, based on cycle counts and equipment usage. Semi-annual preventive maintenance shall be performed. Additionally, technicians shall perform software update and/or confirm software is working properly. Contractor shall furnish all labor, transportation, and parts necessary to provide an on-going support and preventative maintenance agreement of the equipment listed for Pneumatic tube delivery service located at the James A. Haley Veterans Hospital, 13000 Bruce B. Downs Blvd., Tampa Florida. QUALIFICATIONS OF PERSONNEL SERVICING EQUIPMENT Each respondent must have an established business, with an office and full-time staff to include a Fully Qualified Field Service Engineer (FSE) who will serve as backup. Fully Qualified is based upon training and on experience in the field. For training, the FSE(s) has successfully completed a formalized training program for the equipment identified in the schedule of services. For field experience, the FSE(s) has a minimum of two years experience with respect to scheduled and unscheduled preventative and remedial maintenance of Pevco pneumatic tube delivery system equipment. The FSE shall be authorized by the contractor to perform the maintenance services. All work shall be performed by Fully Qualified competent FSE(s). The contractor shall provide written assurance to the competency of their personnel and a list of credentials of approved FSE(s) for each make and model the contractor services at the Veterans Administration (VA) Hospital. The Contracting Officer (CO) may authenticate the training requirements and request training certificates or credentials from the contractor at any time for any personnel who are servicing or installing any VA equipment. The CO and/or Contracting Officer s Representative (COR) specifically reserves the right to reject any of the contractor s personnel and refuse them permission to work on the VA equipment. If subcontractors are used, they must be approved in advance by the CO. The contractor shall submit any proposed change in subcontractor(s) to the CO for approval/disapproval. SERVICES TO BE PROVIDED. Service All maintenance will be performed during normal VA business hours (7:00 a.m. - 4:30 p.m.) Monday through Friday, except Federal holidays, unless otherwise specified. Contractor may work outside normal business hours by arrangement with the COR if such services are provided without additional charge to the Government. Any overtime charges must be approved by the CO or designee prior to the initiation of overtime work. TEN (10) HOLIDAYS OBSERVED BY THE FEDERAL GOVERNMENT New Years Day January 1st Martin Luther King Day 3rd Monday in January Presidents Day 3rd Monday in February Memorial Day Last Monday in May Juneteenth June 19th Independence Day July 4th Labor Day 1st Monday in September Columbus Day 2nd Monday in October Veterans Day November 11th Thanksgiving Last Thursday in November Christmas December 25th The VA shall not provide service manuals or service diagnostic software to the contractor. The contractor shall obtain, have on file, and make available to its FSE(s) all operational and technical documentation (e.g., operational and service manuals, schematics, and parts lists) which are necessary to meet the performance requirements of this contract. The location and listing of the service data manuals, by name, and/or the manuals themselves shall be provided to the CO upon request. Scheduled Maintenance. The contract shall include Two (2) comprehensive scheduled Preventative Maintenance (PM) inspections to be performed. A mutually agreed upon time for the inspections shall be scheduled through the COR s Point of Contact (POC) The contractor shall perform PM Service to ensure that equipment listed in the schedule functions in conformance with the latest published edition of NFPA-99, OSHA, and CDRH. The contractor shall provide and utilize procedures and checklists with worksheet originals indicating work performed and actual values obtained (as applicable) provided to the COR at the completion of each PM. PM procedures shall be submitted to the COR for approval prior to the initiation of this service contract. PM SERVICES SHALL INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING. Contractor shall provide Semi-annual preventative maintenance service in accordance with prescribed factory procedures. Additional visits determined for each component run time, application, and location. Preventative maintenance includes minor adjustments, lubricants, and replacement of worn seals. Replacement parts or equipment are government supplied or purchased at a discount from the contractor. * Contractor must provide quote prior to installation of any Government furnished parts/equipment. * Contractor must provide quote prior to installation of any contractor supplied parts/equipment. * Return the equipment to full and proper operating condition and provide documentation of service performed. Parts and assemblies shall be repaired or replaced as necessary. An electrical safety inspection shall be performed at the time of PM and the results documented. After each service call is completed, details from the service report shall be provided to the COR to ensure closed-loop performance. Equipment maintained under this agreement includes: All tubing Seven (7) Stations numbered 10, 20, 25, 30, 35, 45, 50 Four (4) Diverters numbered 11, 12, 13, 15 One (1) Blower numbered 3N *Any service or part replacement tasks not covered under the contract which will require additional funding must be approved, and a purchase order generated, prior to work commencing. OTHER SPECIFIC TASKS. Contractor shall fully maintain, provide upgrades, revisions, and warrants to the standard application software. 24/7 emergency service with a 6-hour response time billed at discounted rates. 24/7 toll free telephone technical support. COMPLIANCE. The Contractor shall be fully responsible for compliance with all Veterans Administration (VA), local, state, and Federal environmental/occupational safety laws, rules and regulations. The Contractor shall follow life and safety codes and take necessary actions to avoid conditions that may be hazardous to the health and safety of hospital personnel and patients. The Contractor is responsible for meeting all applicable OSHA and VA guidelines for safe working processes. ACCESSABILITY AND SECURITY. Contractor shall keep in mind and, to the extent applicable, follow practices that ensure the security and safety of JAH Veterans Hospital facilities, equipment and personnel. To this end, accessibility to all work areas will be provided by the COR. No keys will be issued to Contractor employees. CONTRACTOR EMPLOYEES. Contractor personnel shall present a neat appearance and be easily recognized as contractor employees. Example: wearing of distinctive clothing such as uniform, badges, patches, etc. ESCORT AND JAMES A. HALEY SECURITY POLICE CHECK-IN. Contractor personnel shall check in and out with VA Police dispatch located in the front entrance of the Main Hospital. Access to work areas and performance monitoring will be provided by the COR. PARKING. It is the responsibility of contractor personnel to park only in designated parking areas. Parking information is available from the VA police and COR. The VA will not invalidate or provide reimbursement for parking violations of the contractor s personnel under any circumstances. SMOKING. Smoking is not permitted within or around VA Healthcare System facilities, except within designated areas. LANGUAGE. Contractor personnel are expected to use appropriate and courteous language. Obscene language is not permitted. NOISE AND DISRUPTION. The contractor is required to continuously consider the impact to the medical center in completing the required work. Any operation causing excessive noise or vibration shall be coordinated in advance with the COR. Also, movement of equipment, supplies, and waste through occupied areas, corridors, and elevators must be planned and scheduled with the COR to minimize disruption to hospital operations. CELLULAR PHONES. Cellular phones are acceptable inside the building, except for posted critical care areas. With Sensitive Data and Training VA INFORMATION AND INFORMATION SYSTEM SECURITY/PRIVACY LANGUAGE ACCESS TO VA INFORMATION AND VA INFORMATION SYSTEMS: a. Contractors, contractor personnel, subcontractors, and subcontractor personnel shall be subject to the same Federal laws, regulations, standards, and VA Directives and Handbooks as VA and VA personnel regarding information and information system security. b. A contractor/subcontractor shall request logical (technical) or physical access to VA information and VA information systems for their employees, subcontractors, and affiliates only to the extent necessary to perform the services specified in the contract, agreement, or task order. c. All contractors, subcontractors, and third-party servicers and associates working with VA information are subject to the same investigative requirements as those of VA appointees or employees who have access to the same types of information. The level and process of background security investigations for contractors must be in accordance with VA Directive and Handbook 0710, Personnel Suitability and Security Program. The Office for Operations, Security, and Preparedness is responsible for these policies and procedures. d. Contract personnel who require access to national security programs must have a valid security clearance. National Industrial Security Program (NISP) was established by Executive Order 12829 to ensure that cleared U.S. defense industry contract personnel safeguard the classified information in their possession while performing work on contracts, programs, bids, or research and development efforts. The Department of Veterans Affairs does not have a Memorandum of Agreement with Defense Security Service (DSS). Verification of a Security Clearance must be processed through the Special Security Officer located in the Planning and National Security Service within the Office of Operations, Security, and Preparedness. e. The contractor or subcontractor must notify the Contracting Officer immediately when an employee working on a VA system or with access to VA information is reassigned or leaves the contractor or subcontractor s employ. The Contracting Officer must also be notified immediately by the contractor or subcontractor prior to an unfriendly termination. VA INFORMATION CUSTODIAL LANGUAGE: a. Information made available to the contractor or subcontractor by VA for the performance or administration of this contract or information developed by the contractor/subcontractor in performance or administration of the contract shall be used only for those purposes and shall not be used in any other way without the prior written agreement of the VA. This clause expressly limits the contractor/subcontractor's rights to use data as described in Rights in Data - General, FAR 52.227-14(d) (1). b. VA information should not be co-mingled, if possible, with any other data on the contractors/subcontractor s information systems or media storage systems in order to ensure VA requirements related to data protection and media sanitization can be met. If co-mingling must be allowed to meet the requirements of the business need, the contractor must ensure that VA s information is returned to the VA or destroyed in accordance with VA s sanitization requirements. VA reserves the right to conduct on-site inspections of contractor and subcontractor IT resources to ensure data security controls, separation of data and job duties, and destruction/media sanitization procedures are in compliance with VA directive requirements. c. Prior to termination or completion of this contract, contractor/subcontractor must not destroy information received from VA, or gathered/created by the contractor in the course of performing this contract without prior written approval by the VA. Any data destruction done on behalf of VA by a contractor/subcontractor must be done in accordance with National Archives and Records Administration (NARA) requirements as outlined in VA Directive 6300, Records and Information Management and its Handbook 6300.1 Records Management Procedures, applicable VA Records Control Schedules, and VA Handbook 6500.1, Electronic Media Sanitization. Self-certification by the contractor that the data destruction requirements above have been met must be sent to the VA Contracting Officer within 30 days of termination of the contract. d. The contractor/subcontractor must receive, gather, store, back up, maintain, use, disclose and dispose of VA information only in compliance with the terms of the contract and applicable Federal and VA information confidentiality and security laws, regulations and policies. If Federal or VA information confidentiality and security laws, regulations and policies become applicable to the VA information or information systems after execution of the contract, or if NIST issues or updates applicable FIPS or Special Publications (SP) after execution of this contract, the parties agree to negotiate in good faith to implement the information confidentiality and security laws, regulations and policies in this contract. e. The contractor/subcontractor shall not make copies of VA information except as authorized and necessary to perform the terms of the agreement or to preserve electronic information stored on contractor/subcontractor electronic storage media for restoration in case any electronic equipment or data used by the contractor/subcontractor needs to be restored to an operating state. If copies are made for restoration purposes, after the restoration is complete, the copies must be appropriately destroyed. f. If VA determines that the contractor has violated any of the information confidentiality, privacy, and security provisions of the contract, it shall be sufficient grounds for VA to withhold payment to the contractor or third party or terminate the contract for default or terminate for cause under Federal Acquisition Regulation (FAR) part 12. g. If a VHA contract is terminated for cause, the associated BAA must also be terminated and appropriate actions taken in accordance with VHA Handbook 1600.1, Business Associate Agreements. Absent an agreement to use or disclose protected health information, there is no business associate relationship. h. The contractor/subcontractor must store, transport, or transmit VA sensitive information in an encrypted form, using VA-approved encryption tools that are, at a minimum, FIPS 140-2 validated. i. The contractor/subcontractor s firewall and Web services security controls, if applicable, shall meet or exceed VA s minimum requirements. VA Configuration Guidelines are available upon request. j. Except for uses and disclosures of VA information authorized by this contract for performance of the contract, the contractor/subcontractor may use and disclose VA information only in two other situations: (i) in response to a qualifying order of a court of competent jurisdiction, or (ii) with VA s prior written approval. The contractor/subcontractor must refer all requests for, demands for production of, or inquiries about, VA information and information systems to the VA contracting officer for response. k. Notwithstanding the provision above, the contractor/subcontractor shall not release VA records protected by Title 38 U.S.C. 5705, confidentiality of medical quality assurance records and/or Title 38 U.S.C. 7332, confidentiality of certain health records pertaining to drug addiction, sickle cell anemia, alcoholism or alcohol abuse, or infection with human immunodeficiency virus. If the contractor/subcontractor is in receipt of a court order or other requests for the above-mentioned information, that contractor/subcontractor shall immediately refer such court orders or other requests to the VA contracting officer for response. l. For service that involves the storage, generating, transmitting, or exchanging of VA sensitive information but does not require C&A or an MOU-ISA for system interconnection, the contractor/subcontractor must complete a Contractor Security Control Assessment (CSCA) on a yearly basis and provide it to the COTR. SECURITY INCIDENT INVESTIGATION: a. The term security incident means an event that has, or could have, resulted in unauthorized access to, loss or damage to VA assets, or sensitive information, or an action that breaches VA security procedures. The contractor/subcontractor shall immediately notify the COTR and simultaneously, the designated ISO and Privacy Officer for the contract of any known or suspected security/privacy incidents, or any unauthorized disclosure of sensitive information, including that contained in system(s) to which the contractor/subcontractor has access. b. To the extent known by the contractor/subcontractor, the contractor/subcontractor s notice to VA shall identify the information involved, the circumstances surrounding the incident (including to whom, how, when, and where the VA information or assets were placed at risk or compromised), and any other information that the contractor/subcontractor considers relevant. c. With respect to unsecured protected health information, the business associate is deemed to have discovered a data breach when the business associate knew or should have known of a breach of such information. Upon discovery, the business associate must notify the covered entity of the breach. Notifications need to be made in accordance with the executed business associate agreement. d. In instances of theft or break-in or other criminal activity, the contractor/subcontractor must concurrently report the incident to the appropriate law enforcement entity (or entities) of jurisdiction, including the VA OIG and Security and Law Enforcement. The contractor, its employees, and its subcontractors and their employees shall cooperate with VA and any law enforcement authority responsible for the investigation and prosecution of any possible criminal law violation(s) associated with any incident. The contractor/subcontractor shall cooperate with VA in any civil litigation to recover VA information, obtain monetary or other compensation from a third party for damages arising from any incident, or obtain injunctive relief against any third party arising from, or related to, the incident. LIQUIDATED DAMAGES FOR DATA BREACH: a. Consistent with the requirements of 38 U.S.C. §5725, a contract may require access to sensitive personal information. If so, the contractor is liable to VA for liquidated damages in

Attachments

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in April 2025

More lists