<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/114376271825331558" -->

---
title: H161--Generator Load Banking (36C24825Q0691) | Closed - MatchAwards
description: H161--Generator Load Banking. United States Department of Veterans Affairs. Solicitation 36C24825Q0691. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Total small business set-aside. Deadline 2025-05-13. STATEMENT OF...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/114376271825331558
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: H161--Generator Load Banking (36C24825Q0691) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/114376271825331558
og:description: H161--Generator Load Banking. United States Department of Veterans Affairs. Solicitation 36C24825Q0691. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. Total small business set-aside. Deadline 2025-05-13. STATEMENT OF...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# H161--Generator Load Banking

Status

Closed, the response deadline passed on May 13, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

TAMPA, USA

Notice type

Presolicitation

Solicitation number

36C24825Q0691

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

H161 - QUALITY CONTROL- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT

Set-aside

[Total Small Business Set-Aside (FAR 19.5)](/contracts/small-business)

Posted

2025-05-05

Deadline

2025-05-13

## Description

STATEMENT OF WORK FOR GENERATOR LOAD BANKING AT CW BILL YOUNG VA MEDICAL CENTER 10000 BAY PINES BLVD., BAY PINES, FL 33744 OVERVIEW The contractor shall provide all the necessary labor, equipment, cables, transportation and supervision for an annual load banking of eight (8) generator units at CW Bill Young VA Medical Center. This is for a four hour load bank. Base and 4 option years. Base year 06/29/2025 06/28/2026 Option year 1 06/29/2026 06/28/2027 Option year 2 06/29/2027 06/28/2028 Option year 3 06/29/2028 06/28/2029 Option year 4 06/29/2029 06/28/2030 GENERATORS The generators in this scope of work are: Bldg. 1, Marathon 600 kW, 750 kVA, 277/480v Bldg. 19, Magnetek 100 kW, 120 kVA, 120/208v Bldg. 24, Allis-Chalmers 100 kW, 113 kVA, 120/208 Bldg. 37, Caterpillar 300 kW, 375 kVA, 120/208v Bldg. 46, Onan 350 kW, 437 kVA, 277/480v Bldg. 101, Caterpillar 210 kW, 263 kVA, 277/480v Bldg. 102, Caterpillar 350 kW, 400 kVA, 277/480v Bldg. 106, Generac 600 kW, 750 kVA, 277/480v GENERAL REQUIREMENTS The load banking shall meet the Joint Commission s requirements and are as follows: 30% of nameplate rating for 2 hours, followed by 50% of nameplate rating for 1 hour, followed by 75% of nameplate ratings for 1 hour, plus warm up and cool down time for a total continuous run of 4 hours. A written record shall be kept of each generator run. At 15 minute intervals, the following readings will be recorded: Lube Oil Pressure Water Temperature Exhaust Temperature Amperes Volts Frequency Prior to starting the generators, the contractor shall perform a pre-run inspection to include checking the oil level, coolant level and a visual inspection of the motor/generator. The contractor will be required to furnish and make the necessary cable connections from the generator to the load bank. This may require parallel runs of cabling. In some locations, this may require barricades, safety cones or both. A site visit will be required to determine parking, pathways and proper connections to the generator units. Hours of work will be Monday through Friday, 6:00 AM - 4:00 PM. Government Holidays will not be worked. The target month for this work will be June. The work performed shall not interrupt any power to the buildings in this Scope of Work. QUALIFICATIONS OF CONTRACTORS The contractor shall have technical training and track records of proven experience with generator operations and load banking for a minimum of five (5) continuous years. The contractor shall have safety training either on-the-job or class-room type in electrical safety outlined in the OSHA Standard 29 Code of Federal Regulations (CFR) 1910 Subpart S Electrical and NFPA 70E Standard of Electrical Safety in the Workplace. Training certifications shall be submitted to the VA Contracting Officer prior to work. If no training certificates are available, the contractor s employer shall certify that the service technician has met this requirement and submit it to the VA Contracting Officer. The contractor shall contact the Supervisor of the Electric Shop, Greg Thomas, at (727) 410-4808 to schedule the load banking a minimum of two weeks in advance. SUMMARY OF WORK Provide a complete written report of the load banking for each generator. Information in the report shall have the following data: Company s name, address, telephone number and fax number Name and signature of contractors who performed the load bank. VA purchase order number or Contract Number. Date and time of work. Generator building number. Generator model, Engine model, Nameplate rating The fifteen minute interval log that was that was recorded during the load bank. Description of generator condition and any deficiencies, if any. 

<!-- mobian-agent-ad sponsored="true" id="24a4337a-c331-49ec-b97b-fba913162156" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/29d36f312b224a97999fe95bb863e64a/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/479e50973e7a4ac0b018ba4df3d62663/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e965fddca2ab40de806e6660527613ef/download)

## Contacts

* William Penhallegon, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/59a5fb10d91742fb9cff44c458ae8f8d/view)

[More from United States Department of Veterans Affairs posted in April 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-04)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Small Business Set-Aside Government Contracts Available Now](/contracts/small-business)

```json
{"@context":"https://schema.org","@type":"Demand","name":"H161--Generator Load Banking","description":"STATEMENT OF WORK FOR GENERATOR LOAD BANKING AT CW BILL YOUNG VA MEDICAL CENTER 10000 BAY PINES BLVD., BAY PINES, FL 33744 OVERVIEW The contractor shall provide all the necessary labor, equipment, cables, transportation and supervision for an annual load banking of eight (8) generator units at CW Bill Young VA Medical Center. This is for a four hour load bank. Base and 4 option years. Base year 06/29/2025 06/28/2026 Option year 1 06/29/2026 06/28/2027 Option year 2 06/29/2027 06/28/2028 Option year 3 06/29/2028 06/28/2029 Option year 4 06/29/2029 06/28/2030 GENERATORS The generators in this scope of work are: Bldg. 1, Marathon 600 kW, 750 kVA, 277/480v Bldg. 19, Magnetek 100 kW, 120 kVA, 120/208v Bldg. 24, Allis-Chalmers 100 kW, 113 kVA, 120/208 Bldg. 37, Caterpillar 300 kW, 375 kVA, 120/208v Bldg. 46, Onan 350 kW, 437 kVA, 277/480v Bldg. 101, Caterpillar 210 kW, 263 kVA, 277/480v Bldg. 102, Caterpillar 350 kW, 400 kVA, 277/480v Bldg. 106, Generac 600 kW, 750 kVA, 277/480v GENERAL REQUIREMENTS The load banking shall meet the Joint Commission s requirements and are as follows: 30% of nameplate rating for 2 hours, followed by 50% of nameplate rating for 1 hour, followed by 75% of nameplate ratings for 1 hour, plus warm up and cool down time for a total continuous run of 4 hours. A written record shall be kept of each generator run. At 15 minute intervals, the following readings will be recorded: Lube Oil Pressure Water Temperature Exhaust Temperature Amperes Volts Frequency Prior to starting the generators, the contractor shall perform a pre-run inspection to include checking the oil level, coolant level and a visual inspection of the motor/generator. The contractor will be required to furnish and make the necessary cable connections from the generator to the load bank. This may require parallel runs of cabling. In some locations, this may require barricades, safety cones or both. A site visit will be required to determine parking, pathways and proper connections to the generator units. Hours of work will be Monday through Friday, 6:00 AM - 4:00 PM. Government Holidays will not be worked. The target month for this work will be June. The work performed shall not interrupt any power to the buildings in this Scope of Work. QUALIFICATIONS OF CONTRACTORS The contractor shall have technical training and track records of proven experience with generator operations and load banking for a minimum of five (5) continuous years. The contractor shall have safety training either on-the-job or class-room type in electrical safety outlined in the OSHA Standard 29 Code of Federal Regulations (CFR) 1910 Subpart S Electrical and NFPA 70E Standard of Electrical Safety in the Workplace. Training certifications shall be submitted to the VA Contracting Officer prior to work. If no training certificates are available, the contractor s employer shall certify that the service technician has met this requirement and submit it to the VA Contracting Officer. The contractor shall contact the Supervisor of the Electric Shop, Greg Thomas, at (727) 410-4808 to schedule the load banking a minimum of two weeks in advance. SUMMARY OF WORK Provide a complete written report of the load banking for each generator. Information in the report shall have the following data: Company s name, address, telephone number and fax number Name and signature of contractors who performed the load bank. VA purchase order number or Contract Number. Date and time of work. Generator building number. Generator model, Engine model, Nameplate rating The fifteen minute interval log that was that was recorded during the load bank. Description of generator condition and any deficiencies, if any.","url":"https://matchawards.com/department_of_veterans_affairs/posts/114376271825331558","identifier":"36C24825Q0691","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"H161 - QUALITY CONTROL- ELECTRIC WIRE AND POWER DISTRIBUTION EQUIPMENT"}],"availabilityStarts":"2025-05-05","availabilityEnds":"2025-05-13","validThrough":"2025-05-13T23:59:59-04:00","sameAs":"https://sam.gov/opp/59a5fb10d91742fb9cff44c458ae8f8d/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Small business","item":"https://matchawards.com/contracts/small-business"}]}
```