<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/114269635097156669" -->

---
title: 6640--New Long Term Procurement - Base 2 CPRR… (36C26025Q0422) | Closed - MatchAwards
description: 6640--New Long Term Procurement  - Base   2  CPRR reagents and consumables for Laboratory Tests. United States Department of Veterans Affairs. Solicitation 36C26025Q0422. NAICS 325413 - In-Vitro Diagnostic Substance Manufacturing. Deadline 2025-04-11. BPA LANGUAGE INTENT: Pursuant to Federal...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/114269635097156669
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: 6640--New Long Term Procurement - Base 2 CPRR… (36C26025Q0422) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/114269635097156669
og:description: 6640--New Long Term Procurement  - Base   2  CPRR reagents and consumables for Laboratory Tests. United States Department of Veterans Affairs. Solicitation 36C26025Q0422. NAICS 325413 - In-Vitro Diagnostic Substance Manufacturing. Deadline 2025-04-11. BPA LANGUAGE INTENT: Pursuant to Federal...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# 6640--New Long Term Procurement - Base 2 CPRR reagents and consumables for Laboratory Tests.

Status

Closed, the response deadline passed on Apr 11, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

VANCOUVER, USA

Notice type

Solicitation

Solicitation number

36C26025Q0422

NAICS

[325413 - In-Vitro Diagnostic Substance Manufacturing](/groups/361)

PSC

6640 - LABORATORY EQUIPMENT AND SUPPLIES

Category

[Test & Measurement Supplies (5.4)](/categories/industrial-products-and-services/test-and-measurement-supplies)

Posted

2025-04-02

Deadline

2025-04-11

## Description

BPA LANGUAGE INTENT: Pursuant to Federal Supply Schedule (FSS) and FSS Contract Clause I-FSS-646, it is the intent of the Department of Veterans Affairs, (herein afterwards referred to as VHAPORHCS to establish a Three-year procurement for Automated Chemistry Immunochemistry Instrumentation or continuation of current Automated Chemistry Immunochemistry Instrumentation. The Government will award a CPRR BPA to a single Contractor for Automated Chemistry Immunochemistry Instrumentation. Contractor agrees to the following terms of the BPA exclusively with VAPORHCS awarded in the final BPA. Additional tests/reagents/instrumentation may be added to the BPA as new technology becomes available on the market and added to the base FSS contract. ORDERS: All products ordered under this BPA, placed against the Federal Supply Schedule Award Contract(s), are subject to the terms and conditions of the FSS contract. This BPA does not obligate any funds. The Government is obligated only to the extent of authorized orders actually issued under the BPA by authorized individuals. PRICES AND TERMS: VAPORHCS will provide an estimated annual volume by test as reflected in Attachment D.1\. The Government estimates the volumes at VAPORHCS as listed in Attachment D.1, but does not guarantee volumes as listed; they are estimates ONLY. The facility will fax, email or upload their test counts from the chemistry analyzers. By the 10th of the following month to the contractor. TERM OF AGREEMENT: This will be a single award, firm-fixed price BPA with one base year and two, one year options and shall be effective for the term of the FSS Contract including additional FSS extensions. The Contractor is required to immediately notify the CO (Government Contracting Officer), in writing, if at any time the FSS contract upon which this BPA is based, is no longer in force. The resulting BPA shall be automatically extended for the remaining term of the BPA without modification upon any extensions of the Contractor s FSS contract. In addition, where a new FSS contract replaces Contractor s current FSS contract, the resulting BPA may be reassigned under the new FSS contract for the remaining term of the BPA with written agreement between Contractor and the contracting officer. This BPA is not a contract. If the Contractor fails to perform in a manner satisfactory to the CO, this BPA may be canceled with thirty (30) days written notice to the Contractor by the CO. The Contractor shall also reserve the right to terminate this contract with 60 days notification to the CO. This BPA shall be reviewed annually. VAPORHCS intends to establish the base year of the agreement for the period of 6/16/2025 through 6/15/2026\. IDENTIFICATION: Delivery Orders issued shall be identified by their applicable FSS Contract Number and BPA Number. FSS & BPA identification numbers are assigned through the VHA Procurement Activity; CO: click here to insert identification numbers (BPA & FSS). ORDERING METHOD: The participating facilities may order products via Electronic Data Interchange (EDI), telephone, facsimile or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. DESCRIPTION/SPECIFICATIONS/TECHNICAL EVALUATION PLAN SCOPE OF PROCUREMENT: The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the Technical Evaluation Plan. The instrument shall have random access capability (if discrete testing is required) and be able to simultaneously perform the complete profile as described below meeting the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). If Contractor offers an integrated family of analyzers, the technical evaluation panel will determine if instrumentation proposed meets needs of using facility. Equipment shall be acquired for each of the clinical laboratories located at the VAPORHCS. The Contractor is required to provide a continuously stocked inventory of reagents, standards, Vendor provided Controls, supplies, disposables and any other materials, to include replacement parts, required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration date must be clearly marked on reagent, standards and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. Contractor is required to provide vendor controls for troubleshooting and/or routine use as needed. The Contractor will provide a detailed list of all parts and supplies that are to be purchased by the facility and are not included in the CPRR contract. Special handling for emergency orders of supplies: In the event that the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery. DEFINITIONS: Cost per Patient Reportable Result (CPRR)- as defined in the Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers - Contractors are required to provide a price for a reportable patient result. The per patient reportable result price shall include costs covering: (1) 5 year equipment use, (2) all reagents, standards, Vendor provided quality Controls, supplies, consumable/disposable items, parts, accessories and any other item required for the proper operation of the Contractor s equipment and necessary for the generation of a patient reportable result. This per patient reportable result price shall also encompass all costs associated with dilution; repeat and confirmatory testing required to produce a single patient reportable result. It shall also include the material to perform as well as all other costs associated with quality control, calibration and correlation study testing that is prescribed by the Clinical and Laboratory Standards Institute (CLSI). (3) all necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and (4) training for Government personnel. Contractors shall provide delivery, installation and removal of equipment at no additional charge. Cost per Test (CPT)- as defined in the Federal Supply Schedule FSC Group 66, Part III, Cost-Per-Test Clinical Laboratory Analyzers Contractors are required to provide a price for each test that can be performed on its equipment. The per test price shall include costs covering (1) 5 year equipment use, (2) all reagents, standards, quality Vendor provided Controls, linearity material, calibration verification material, supplies, consumable/disposable items, parts, accessories and any other item required for the proper operation of the Contractor s equipment and necessary for the generation and reporting of a test result, (3) all necessary maintenance to keep the equipment in good operating condition (This element includes both preventive maintenance and emergency repairs) and (4) training for Government personnel. Contractors are required to provide delivery, installation and removal of equipment at no additional charge. Business Associate Agreement (BAA)- A business associate is an entity, including an individual, company, or organization that, on behalf of VHA, performs or assists in the performance of functions or activities involving the use or disclosure of PHI, or that provides certain services involving the disclosure of protected health information (PHI). VHA is a covered entity under the HIPAA Privacy Rule (Privacy Rule). HIPAA regulations require VHA to execute HIPAA-compliant BAAs with certain entities that receives, uses, or discloses VHA PHI in order to perform some activity for VHA. These BAAs obligate VHA business associates to provide the same protections and safeguards to PHI that is required of VHA under the Privacy Rule. Specimen Processing Automation Line Pre-analytical processing and archival processing equipment that will automate these specimen processing functions, as indicated in the general requirements section. Specimen Management System - A component of the Processing Automation Line that directs and manages the operation and components of the pre-analytical processing/automation system. Contractor Middleware Management System - A server installed with software that interfaces the testing instrumentation to the Laboratory Information system and is able to receive, process and send data following CLSI guidelines. Throughput The speed that the equipment processes and/or operates reported in units per hour. TEST MENU: Refer to Attachment D.1 for desired test menu and estimated annual volumes by laboratory. Special testing requirements: HIV Methodology shall be 4th generation or higher to meet the CDC requirement for HIV testing. Rapid testing for cardiac marker High Sensitive Troponin T, 10 minutes or less. IDMS traceable Creatinine Reagent is available. Rapid testing for intraoperative PTH. 10 minute or less. GENERAL REQUIREMENTS: Primary analyzer(s) Base equipment offered shall be new and shall fully support the scope of operations (minimal requirements). Depending upon the technical functionality and the capabilities of the individual manufacturer s instrumentation, one analyzer or multiple analyzers may be required to meet the productivity specifications defined herein. Analyzers offered per facility shall provide sufficient capacity and throughput to meet the volume and service demands as defined in Attachment D.1\. In those instances, the additional analyzer(s) shall, likewise, be considered primary instrumentation and shall meet all of the technical specifications of this solicitation. Those additional analyzer(s) offered meeting the definition of a primary analyzer may serve as a back-up analyzer (see definition below) and shall replace the requirement for offering that category of equipment. Back-up Analyzer; equipment required in support of operations for the VA laboratories in the event the primary analyzer(s) becomes non-operational/non-functional. In the instance that the mirror imaged analyzers become unavailable the back-up analyzer will be used. As such, the requirements for consumable supplies, i.e. reagents, quality control material, calibrators, etc., shall be minimal and corollary to the successful operation of the primary instrumentation. Specific tests that require back-up performance are listed in Attachment D.1\. Additional primary analyzers required for the performance of daily workload are not considered back-ups for the purposes of consumables, reagents, etc. Installation Contractor will provide an alternate site for validation of the instrumentation if space is not available for side-by-side validation with existing instrumentation. Contractor will perform, at their cost, new validation studies as defined by the customer when instrumentation is installed in the final workspace. Operational and Technical Features- The instrumentation offered shall be approved by the Food and Drug Administration (FDA) and Contractor s FSS Contract at the time of proposal submission and have the following: Primary Processing Automation Line Instrumentation. Offering for an Integrated Clinical Laboratory Chemistry/Immunochemistry Instrumentation and Robotics System (Automated track or line) in accordance with the requirements of each respective laboratory, as listed in Attachment D.2, shall have the following listed below. Please include a clear description regarding how samples are transported on the rack. Sufficient capacity and throughput to meet the volume and service demands as defined in Attachment D.1\. Includes a specimen management system to manage and track sample progress and position. Specimen archival through mapping of specimen location; for easy retrieval once moved off-line. (Specimen Management System). The ability, based on test requests, to sort and route specimens. (Line/track system/ Specimen Management System) The ability to send the primary tube or processed aliquots by means of a tracking system to the proper testing instrumentation to maximize efficiency and to maintain and standardize turnaround times of results. (Line/track system/ Specimen Management System) Minimal operator intervention to introduce STAT specimens or to change a routine specimen priorities. The ability to detect processing errors and provide error notification. (Specimen Management System) The ability to separate the serum/plasma from the blood cells through the process of centrifugation. (Centrifuge) Ability to detect short samples and clots (Aliquotter) The ability to remove caps from blood collection tubes. (Decapper) The ability to recap and/or reseal - tubes. (Recapper) The ability to remove an aliquot of serum/plasma using disposable pipette tips to prevent contamination and move into another specimen tube or cup for analysis. (Aliquotter) The ability to print bar code labels and label daughter (aliquot) tubes to maintain positive specimen identification. The ability to connect all primary and back-up testing analyzers offered in accordance with Attachment D.2 Ensure immediate availability of primary tube after initial testing is completed. The ability to auto-archive, store and retrieve specimens. Capacity to be determined by Attachment D.2\. Barcode reader stations must have the following capabilities: The accuracy of the barcode reading must have less than a 1.0 % failure rate. Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. Equipment must accept, at a minimum, 10 characters in specimen identifier that is alpha, numeric, and/or alphanumeric concurrently. Testing Instrumentation The testing instrumentation must be an integrated platform with flexible, components that can be upgraded and or reconfigured on site and is approved by the Food and Drug Administration (FDA) and on Contractors FSS Contract at the time of proposal submission and shall have the following: The capability of performing analysis on 100% of the tests listed in Attachment D.1\. with no more than 10% repeats of CPRR. Sufficient capacity and throughput to meet the volume and service demands as defined in Attachment D.1\. An instrument management system (internal to testing instrumentation) that provides/maintains the following: Ability to monitor instrument performance. Continuous monitoring of vital functions with immediate operator notification of failure(s) and on-board storage of these records. Capability to detect and alert operator of out of range quality control results via flagged results on QC printout and visual alerts on display monitor. Ability to store and retransmit patient records to the VA Laboratory Information system for a minimum 48 hours in case of interface outage. Capability to record, store and print the following information: Required quality control and instrument maintenance information. Patient demographic information and specimen results. On board reagent inventory system. A bi-directional, bar-coded computer interface compatible with the current VA laboratory information system. The fully operational interface (both hardware and software) shall be immediately available for implementation to the VA computerized hospital information system. The accuracy of the barcode reading must have less than a 1.0 % failure rate. Equipment must be able to support multiple barcode formats (Code 39, Code 128) that may be enabled concurrently. Equipment must accept, at a minimum, 10 characters in specimen identifier that is alpha and/or numeric depending on site that may be enabled concurrently. Bar coding of reagents and the ability to track reagent containers throughout the testing process using bar code technology. Ability to prioritize STAT testing without compromising existing programmed testing. Minimal operator intervention to introduce STAT specimens or to change a routine specimen to a STAT specimen, as well as introduce STAT specimens during a test run without aborting a run. Vendor will outline STAT procedure. On board reagent stability, sufficient to accommodate both high and low volume use. See ATT D.1 The ability to detect and alert operator of low reagent levels and the potential of depletion. The ability to load and unload all reagents from the equipment during operation without interrupting testing in progress or have sufficient capacity to enable a complete 24 hours of testing. The ability to support multiple reagent lots of the same reagent on the equipment at the same time with active, valid calibrations. The ability to maintain multiple calibrations per analyte. The capability to calibrate assays during test run without aborting the run. The capabilities to store, print, and retrieve calibration data. For routine (general) chemistry tests, when more than one lot of a given reagent has a valid calibration and quality control material is programmed to run as a control (in the control mode): Operatory shall be notified if a new lot number is about to be run to ensure that quality control material is performed. Quality control results will be easily distinguishable i.e., identified by reagent lot number or similar mechanism, on instrument printout or display monitor. Operator may select to run a test on only a specified lot of reagent even though more than one lot has a valid calibration The ability to continuously load patient specimens. The ability to detect short samples and interfering indices i.e. hemolysis, lipemia, and icterus, on all systems including Chemistry, Immunochemistry and pre-analytics. Clot detection with alert notification. Primary tube sampling from various manufacturers and sizes of evacuated tubes. Automatically repeat testing when defined limits are exceeded via auto dilution or sample volume adjustment. The capability to program a test as a repeat with interfacing of results to overlay initial result. Safety features to avoid unnecessary exposure to biohazardous and chemical material. The exposure to and the volume of biohazardous and chemical material generated by the equipment must be minimal and require a minimum amount of handling. For those sites requiring back up analyzers, it is desirable for the backup analyzer to be a mirror image or have the same reagent requirement as the primary analyzer. Ability to store and retransmit records (48 hours of maximal instrument throughput) in case of interface outage. Calibration stability adheres to manufacture s specifications. User defined/Open Channel test capability. In the event that the contractor cannot provide desired assays, the contractor will provide appl 

<!-- mobian-agent-ad sponsored="true" id="c62a9980-6e10-4748-9e50-5fa90fb2527b" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/test-and-measurement-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cfbd85493f2c4cfba6781b4f8826c784/download)

## Contacts

* Hector D Gonzalez, Contract Specialist

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/9439f3c91359491297cee6597e6707a3/view)

[More from United States Department of Veterans Affairs posted in April 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-04)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Manufacturing Government Contracts Available Now](/contracts/manufacturing)

```json
{"@context":"https://schema.org","@type":"Demand","name":"6640--New Long Term Procurement  - Base   2  CPRR reagents and consumables for Laboratory Tests.","description":"BPA LANGUAGE INTENT: Pursuant to Federal Supply Schedule (FSS) and FSS Contract Clause I-FSS-646, it is the intent of the Department of Veterans Affairs, (herein afterwards referred to as VHAPORHCS to establish a Three-year procurement for Automated Chemistry Immunochemistry Instrumentation or continuation of current Automated Chemistry Immunochemistry Instrumentation. The Government will award a CPRR BPA to a single Contractor for Automated Chemistry Immunochemistry Instrumentation. Contractor agrees to the following terms of the BPA exclusively with VAPORHCS awarded in the final BPA. Additional tests/reagents/instrumentation may be added to the BPA as new technology becomes available on the market and added to the base FSS contract. ORDERS: All products ordered under this BPA, placed against the Federal Supply Schedule Award Contract(s), are subject to the terms and conditions of the FSS contract. This BPA does not obligate any funds. The Government is obligated only to the extent of authorized orders actually issued under the BPA by authorized individuals. PRICES AND TERMS: VAPORHCS will provide an estimated annual volume by test as reflected in Attachment D.1. The Government estimates the volumes at VAPORHCS as listed in Attachment D.1, but does not guarantee volumes as listed; they are estimates ONLY. The facility will fax, email or upload their test counts from the chemistry analyzers. By the 10th of the following month to the contractor. TERM OF AGREEMENT: This will be a single award, firm-fixed price BPA with one base year and two, one year options and shall be effective for the term of the FSS Contract including additional FSS extensions. The Contractor is required to immediately notify the CO (Government Contracting Officer), in writing, if at any time the FSS contract upon which this BPA is based, is no longer in force. The resulting BPA shall be automatically extended for the remaining term of the BPA without modification upon any extensions of the Contractor s FSS contract. In addition, where a new FSS contract replaces Contractor s current FSS contract, the resulting BPA may be reassigned under the new FSS contract for the remaining term of the BPA with written agreement between Contractor and the contracting officer. This BPA is not a contract. If the Contractor fails to perform in a manner satisfactory to the CO, this BPA may be canceled with thirty (30) days written notice to the Contractor by the CO. The Contractor shall also reserve the right to terminate this contract with 60 days notification to the CO. This BPA shall be reviewed annually. VAPORHCS intends to establish the base year of the agreement for the period of 6/16/2025 through 6/15/2026. IDENTIFICATION: Delivery Orders issued shall be identified by their applicable FSS Contract Number and BPA Number. FSS \u0026 BPA identification numbers are assigned through the VHA Procurement Activity; CO: click here to insert identification numbers (BPA \u0026 FSS). ORDERING METHOD: The participating facilities may order products via Electronic Data Interchange (EDI), telephone, facsimile or other written communication, identifying the products by number, quantity, purchase price, address for delivery, and any special instructions. DESCRIPTION/SPECIFICATIONS/TECHNICAL EVALUATION PLAN SCOPE OF PROCUREMENT: The desired instrumentation shall have the capability of performing or reporting the clinical parameters as defined in the Technical Evaluation Plan. The instrument shall have random access capability (if discrete testing is required) and be able to simultaneously perform the complete profile as described below meeting the performance characteristics for accuracy and precision as defined by the 1988 Clinical Laboratory Improvement Act (CLIA) and the Clinical and Laboratory Standards Institute (CLSI). If Contractor offers an integrated family of analyzers, the technical evaluation panel will determine if instrumentation proposed meets needs of using facility. Equipment shall be acquired for each of the clinical laboratories located at the VAPORHCS. The Contractor is required to provide a continuously stocked inventory of reagents, standards, Vendor provided Controls, supplies, disposables and any other materials, to include replacement parts, required to properly perform tests on the equipment such that equipment operations are not interrupted. These items shall be of the highest quality, sensitivity, specificity and tested to assure precision and accuracy. Expiration date must be clearly marked on reagent, standards and control containers. Unexpected changes in methodology/technology shall be at the expense of the Contractor. Alert/Notification of any delays in shipment as well as any or all technical advisory/recalls/alerts, prior to or simultaneously with field alerts should be forwarded to the designated individuals determined at contract award. Contractor is required to provide vendor controls for troubleshooting and/or routine use as needed....","url":"https://matchawards.com/department_of_veterans_affairs/posts/114269635097156669","identifier":"36C26025Q0422","category":"325413 - In-Vitro Diagnostic Substance Manufacturing","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"6640 - LABORATORY EQUIPMENT AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.4 Test \u0026 Measurement Supplies","url":"https://matchawards.com/categories/industrial-products-and-services/test-and-measurement-supplies"}],"availabilityStarts":"2025-04-02","availabilityEnds":"2025-04-11","validThrough":"2025-04-11T23:59:59-04:00","sameAs":"https://sam.gov/opp/9439f3c91359491297cee6597e6707a3/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Manufacturing","item":"https://matchawards.com/contracts/manufacturing"}]}
```

