ClickCease 6525--Mobile MRI Unit VA Illiana Health Care… (36C25225Q0326) | Closed - MatchAwards

6525--Mobile MRI Unit VA Illiana Health Care System

Status
Closed, the response deadline passed on Mar 27, 2025
Agency
United States Department of Veterans Affairs
Office
MILWAUKEE, USA
Notice type
Combined Synopsis/Solicitation
Solicitation number
36C25225Q0326
NAICS
621512 - Diagnostic Imaging Centers
PSC
6525 - IMAGING EQUIPMENT AND SUPPLIES: MEDICAL, DENTAL, VETERINARY
Category
Medical Equipment and Accessories and Supplies (10.2)
Set-aside
Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Posted
2025-03-20
Deadline
2025-03-27
Place of performance
Danville, Illinois 61832-5198, UNITED STATES

Description

36C25225Q0326 Effective Date: 03/15/2023 Revision: 01 This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular Deviations FEB 2025 CAAC Letters 2025-01/02 (eff.02/18/2025). This solicitation is set-aside for Service-Disabled Veteran-Owned Small Businesses (Total SDVOSB Set Aside) who meet the following conditions: 1) vendor must be identified under Government Certifications as a certified Service-Disabled Veteran Owned Small Business (SDVOSB) in the Small Business Administration s (SBA s) certification database found at the Dynamic Small Business Search (DSBS) website: https://dsbs.sba.gov/search/dsp_dsbs.cfm and 2) meet the small business size standard requirement for the applicable NAICS code for this procurement. The associated North American Industrial Classification System (NAICS) code for this procurement is 621512, Diagnostic Imaging Centers. The small business size standard of $19M. The FSC/PSC is W065, Lease or Rental of Equipment-Medical, Dental, and Veterinary Equipment and Supplies. The Department of Veterans Affairs, Network Contracting Office 12 (NCO 12), Veterans Integrated Services Network 12 (VISN 12), Veterans Affairs Illiana Health Care System, Diagnostic Imaging Services located at 1900 East Main St, Danville, Illinois 61832-5198 has a requirement for a Mobile 1.5 Tesla Magnetic Resonance Imaging (MRI) Unit. This requirement is to replace a mobile unit removed due to default. It is estimated the mobile MRI unit will be needed for a base period and four 12-month option periods. The government is seeking to lease the mobile unit only; no personal services are required. VA diagnostic imaging staff will run the equipment and read the images. The MRI unit will be used to perform studies Monday through Friday: 8:00 a.m. to 5:00 p.m. Extended hours and weekends may be required. The facility will be closed on National Holidays. This is a non-personal services requirement. The contractor will be responsible for all management, oversight, supervision, labor, transportation, tools, materials, parts, other items, and the support necessary to perform work, execute services, and to successfully complete all deliverables as contained within this Statement of Work. All interested contractors should provide quotations for the following: Price/Cost Schedule & Item Information Base Period Date of Award 09/30/2025 Line Item Description Qty Unit of Measure Unit Price Total 0001 Mobile MRI Unit 6 MO 0002 Delivery & Setup 1 JB 0003 Training 2 WKS Option Year One 10/01/2025 09/30/2026 Line Item Description Qty Unit of Measure Unit Price Total 1001 Mobile MRI Unit 12 MO Option Year Two 10/01/2026 09/30/2027 Line Item Description Qty Unit of Measure Unit Price Total 2001 Mobile MRI Unit 12 MO Option Year Three 10/01/2027 09/30/2028 Line Item Description Qty Unit of Measure Unit Price Total 3001 Mobile MRI Unit 12 MO Option Year Four 10/01/2028 09/30/2029 Line Item Description Qty Unit of Measure Unit Price Total 4001 Mobile MRI Unit 12 MO Pricing Overview Total Cost for each Period of Performance Base Period $ Option Year One $ Option Year Two $ Option Year Three $ Option Year Four $ Total $ Statement of Work/Description/Specifications OBJECTIVE: The Diagnostic Imaging Services located at Veterans Affairs Illiana Health Care System, 1900 East Main St, Danville, Illinois 61832 (hereinafter referred to as VA) has a requirement for a mobile MRI unit. The requirement includes mobile MRI unit, delivery, mobilization, training, full-service maintenance and repairs, replacement parts, and technical support 24 hours-a-day, 7 days-a-week. MRI studies shall be performed as deemed medically appropriate and requested by the VA. GENERAL: This is a non-personal services requirement. The contractor shall provide all management, oversight, supervision, labor, transportation, tools, materials, parts, other items, and the support necessary to perform work, execute services, and to successfully complete all deliverables as contained within this Statement of Work. Contractor shall be responsible for all the proper maintenance of mobile unit and will provide evidence of required preventative maintenance. The Government will not exercise any supervision and/or control over contractor personal (which includes contractor service providers, contractor representatives, and subcontractors employed with and/or being utilized by the prime contractor) during all active performance periods of the final contract. All contractor personal shall be accountable solely to the Contractor, who in turn is responsible to the Government. SCOPE: The government is seeking to lease a mobile trailer manufactured within the past five years equipped with a state of the art 1.5 Tesla short bore MRI with a minimum 70 cm bore. Lease required includes a base period and four 12-month option periods. PLACE OF PERFORMANCE: Work will be performed, services will be executed, and deliverables will be completed at Veterans Affairs Illiana Health Care System, 1900 East Main Street, Danville, IL 61832-5198. PERIOD OF PERFORMANCE: The expected period of performance for this acquisition is the following: Base Year: Date of Award thru 09/30/2025 Option Year One: 10/01/2025 thru 09/30/2026 Option Year Two: 10/01/2026 thru 09/30/2027 Option Year Three:10/01/2027 thru 09/30/2028 Option Year Four: 10/01/2028 thru 09/30/2029 Option years may or may not be exercised based on the needs of and at the discretion of the Government. The contract is subject to the availability of VA funds. The Contractor shall perform no services after September 30 of any year until the Contracting Officer authorizes such services in writing. WORK HOURS AND SCHEDULE: All performance of work, execution of services, and completion of deliverables must be accomplished during the facility s normal business hours, 8:00 a.m. through 5:00 p.m. Monday through Friday, Federal Holidays excluded. Extended hours and weekends may be utilized at the discretion of the facility. Prior to any efforts proper coordination must be initiated between the contractor and the government to ensure services, work, and/or deliverables can be performed, executed, and/or completed when scheduled. Any work, services, and/or other tasks performed during other than normal business hours must be approved in advance by the Diagnostic Imaging Program Manager, Contracting Officer, and/or other authorized facility designee/representative. Federal Holidays currently observed by the facility are listed in the table below. New Year s Day January 1 Martin Luther King s Birthday Third Monday in January President s Day Third Monday in February Memorial Day Last Monday in May Juneteenth Independence Day June 19th Independence Day July 4 Labor Day First Monday in September Columbus Day Second Monday in October Veterans Day November 11 Thanksgiving Day Fourth Thursday in November Christmas Day December 25 Other Federal Holidays Any other day specifically declared to be a national holiday (per Federal Statute, Executive Order, or by the President s Proclamation). An alternative schedule (different from the schedule described above) may be utilized if there is mutual agreement between the government and the contractor regarding this alternative schedule if implemented. MINIMUM TECHNICAL REQUIREMENT / SPECIFICATIONS: Trailer Requirement: Semi-trailer truck equipped with stabilizing shocks to prevent disruption of the machine. Minimum trailer size of 12 feet wide by 50 feet in length, in accordance with the American Disabilities Act and current VA building standards. Proposed unit will connect to the existing corridor attached to Building 58 and provide functioning service. Trailer should be zoned with secure access between each zone. Trailer should have two patient dressing rooms with lockable storage cabinets. Trailer should have an injection and control room with storage cabinets and control room desk. Trailer should have five-gauss exclusion zone in magnet room Trailer must include MRI coil cabinetry Trailer must include an on-board generator, heating, air conditioning and humidity control systems. Generator unit shall be equipped with Air Pollution Control District in accordance with all local and state requirements. Trailer telephone and data interface must connect with VA Medical Center telephone and IT/PACS Systems. MRI safe patient monitoring (camera) set up. Trailer electrical power source shall be 480V, 3-phase at 150 amps, 60Hz, WYE along with a 50-foot cable and a male connector. VA will provide a parking site as follows: Dimensions: 20 x 60 in size and is asphalt. The site is arranged so the trailer is parked to match the corridor and the patient access door. The contractor will verify the size of the trailer (12 foot wide by 50 foot wide in length) will be able to connect to the existing corridor attached to B-58 and provide functioning service. Electrical service: Single power receptacle (Russell-Stoll DF2504FRAB) connected to a 200-amp 3 pole 480 volt disconnect switch. Two (2) telephone connections and two (2) data connections. Data connections have RJ45 jacks. Cable to telephone and data connections is category 5e. No water connection is provided. MRI Equipment/System: MRI equipment should be a mobile 1.5 Tesla MRI scanner equipped with a magnetic shielding system to meet or exceed the manufacturer's requirement for the medical equipment's MRI system. MRI must have an actively shielded magnet with a fringe field held entirely within the trailer. MRI Protocols at a minimum must include but not be limited to Brain (MRI and MRA), Orbit/Face/Neck, Spine (Cervical, Thoracic, & Lumbar), Routine MSK, Abdomen/Pelvis, Pelvis-Male and Female, Brachial Plexus, Carotid and Renal MRA. MRI software packages at a minimum must include but not be limited to 2D/3D Imaging, ADC Mapping, Neuro, Angio, Body, Ortho, EPI/DWI, T2 Dark fluid 3D TSE, Fast Imaging (i.e. Blade or Propeller), Care Bolus, 2D/3D Phase Contrast, Post-processing Non-contrast MRA and CE MRA, Parallel Imaging, Single Shot EPI, DICOM Worklist, DICOM SCU. Appropriate coils must be included to accommodate and accurately examine all MRI procedures and protocols listed above Spine, Body, Flex, Shoulder, Head, Neck, Extremity, Foot/Ankle, and Knee. MRI must have the ability to plug in multiple coils which can be used simultaneously MRI must have a primary magnetic field spatial gradient field strength mapped at the mouth of the bore, documenting a gradient falloff. MRI must have a minimum 70-centimeter (cm.) diameter bore to accommodate bariatric patients. MRI must have a minimum of 500 lb table load MRI must have a minimum 48-channel system. MRI must provide a comprehensive imaging and workflow system that gives physicians the tools to guide them through various assessments. MRI must interface with VA PACS, VISTA, and DICOM workflows. MRI must be capable of sending images to destinations including but not limited to printer, PAC s, VA RIS System, etc. MRI should have an enhanced communication between patient and MRI technologist MRI must have a Universal Power Supply (UPS) capable of maintaining full functionality of the system for a minimum of 10 minutes during a power outage. MRI must include a power conditioner as recommend by original equipment manufacturer. Ancillary Equipment/Requirement: Must include a Contrast Power Injector Must include new infection control approved patient positioning sponges (sponges will be replaced as needed at no cost throughout the life of the contract) Must include MRI safe transfer table Must include full size walkthrough magnetic metal detector Must include handheld magnetic metal detector Must include MRI safe wheelchair with a capacity to lift a minimum 500 lbs. Must include built in patient lift with a capacity to lift a minimum of 1500 lbs. Must include MRI safe fire extinguisher Optional Accessories to enhance VA Patient experience and comfort such as Digital video goggles and audio headset. In Bore Infotainment Security/Connectivity Requirement: Must have OEM-supported operating system. Must have latest DICOM print, store commit and modality worklist Must have wireless connectivity to VA network Compatible with 802.11b/g/n and FIPS 140-2 compliant. Must have encrypted hard drive. Must have PACS compatibility Optum Change Healthcare Must have PACS compatibility VA VistA Imaging Communication with VA PACS, MRI workstation technology & Radiology service medical printers: The Contractor will ensure all software and licenses necessary to have full DICOM communication between the MRI workstation technology and VA PACS and Radiology service workstations and medical printers. Each MRI study will be transferred to VA PACS immediately following acquisition of the study so that it can, if necessary, be reviewed before the patient leaves the mobile MRI. Contractor Responsibilities: Contractor responsible for all transportation, delivery, set-up, connection to VA provided electrical power, and data and phone lines. NOTE: the site has a nearby electrical transformer, contractor must confirm there will not be any electrical interference. Contractor must provide vendor remote diagnostics via VPN. The vendor shall either utilize the VA national site-to-site VPN or work with the Office of Cyber and Information Security and the VAMC Information Systems Security Officer to establish a client-based VPN. Contractor must provide OEM Engineer upon delivery of unit to verify trailer setup, networking, and full functionality of the MRI unit. Contractor must provide physicist equipment performance evaluations dated within 12 months prior to delivery, and calibration of equipment as required by the manufacturer of the MRI unit. Contractor must provide two weeks of Applications Training (Initial and Delayed) by an Original Equipment Manufacturer MRI Applications Technologists. Applications Technologist must be capable of integrating new technology and facility protocols according to VA Radiologist specifications. Verification of connectivity shall be made by contractors prior to the start of patient procedures immediately following the award of this solicitation. Applicable training will be provided to Radiologists and MRI Technologists, Biomedical Engineers, Medical Engineering, and Information Technology Personal Contractor must provide operator instruction manuals for the trailer and equipment Contractor must provide all recommended routine and annual OEM preventative maintenance on MRI trailer and accessories, inclusive of hard drive and patient data removal at no additional charge to the Government. Contractor shall perform the required work in accordance with Joint Commission, VHA and other regulatory standards. Joint Commission standards may be obtained from the Joint Commission, One Renaissance Blvd, Oakbrook Terrace, IL 60181. The Contracting Officers Representative (COR) shall require access to proof of preventative maintenance and calibration during the performance of the contract. No routine maintenance will be scheduled or performed such that it conflicts with the required schedules of the MRI unit, except to address emergency failures of the unit. Service response time to emergency failures shall be within two hours. Provide 365/24/7 telephone service response line to be answered immediately or within 30 minutes. In the event of equipment failure or unavailability of the mobile MRI unit trailer and/or or equipment, the contractor must make a sound effort to get the unit fully operational within 12 hours. As a result of normal duty time lost during the downtime, the contractor may be required to work outside regular business hours and/or weekends at no additional costs to the Government to reduce patient backlog. VA personal shall be notified immediately of any equipment malfunctions that would hinder the completion of studies. In the event of a system failure, Contractor and the Imaging Supervisor shall work cooperatively to remedy the situation as quickly as possible. Contractor must provide a system that maintains a minimum of 95% up time performance rate, based on the normal MRI duty days and hours. Failure to provide this shall result in a deduction on the contract price by 1/30th for full MRI duty day down. VA Responsibilities: VA responsible for maintenance of connectivity ports appropriate for linking the mobile unit to power, computer network, and local-access phone/modem/fax as needed, after initial installation. VA responsible for all technologist-staffing to operate the mobile MRI VA responsible for the safety of each beneficiary while in their care, throughout the exam. VA responsible for preparation of each patient i.e., safety screening, gowning, scanning for metals, etc. If sedation is needed it will be conscious sedation level only. The Government will be responsible for providing the sedation orders and dosage, instructions for pre and post sedation and recovery and the sedation drug. VA responsible for providing all consumables such as contrast, gloves, syringes, needles etc. VA responsible for providing clean linen and for the laundering of the dirty linen. VA responsible for cleaning the mobile unit and disposal of trash. VA responsible for crash cart located in the Diagnostic Imaging Department. All emergencies will be handled by the VA code Team. The VA will provide written emergency plans addressing emergencies such as patient codes, personal injury, fire, and disruptive behavior. MRI technologists will review MRI safety guidelines with Emergency Responders from the VA. All code patients will be removed from MRI scan room and the MRI technologist will ensure code responders or ferrous equipment is not allowed in the MRI scan room. SPECIAL CONTRACT REQUIREMENTS: The Contracting Officer (CO) is the only person authorized to approve changes or modify requirements. Contractor shall communicate with CO on all matters pertaining to contract administration. Only the CO is authorized to make commitments or issue changes, which will affect price, quantity, or qualify of performance of this contract. Services specified may be changed by written modification to this contract. Modification will be prepared by the VA CO. A representative of the CO will be designated to represent the CO in furnishing technical guidance and advice regarding the work performed under this contract. The foregoing is not to be construed as authorization to interpret or furnish advice and information to the Contractor relative to financial or legal aspects of the contract, but the technical matter experts reside in the serviced departments and as such they are authorized to give technical assistance and guidance. The services to be performed by the contractor will be under the direction of the Chief of Staff, and the Chief, Radiology services. The Radiology Service Program Manager will be the primary point of contact at the VA for communication between the VA and the Contractor regarding technical aspects of imaging protocols and medical aspects of patient studies. The Contractor will communicate to the Program Manager any possible and actual disruptions of MRI service. Upon becoming aware of possible or actual disruption of MRI service, the Contractor wil

Attachments

Contacts

Email and phone are in the source notice.

Source notice

More from United States Department of Veterans Affairs posted in March 2025

More lists