<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/114162050589719141" -->

---
title: SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR… | Closed - MatchAwards
description: SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD. United States Department of Veterans Affairs. Solicitation 36C24525Q0382. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/114162050589719141
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR… | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/114162050589719141
og:description: SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD. United States Department of Veterans Affairs. Solicitation 36C24525Q0382. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD

Status

Closed, the response deadline passed on Mar 24, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LINTHICUM, USA

Notice type

Sources Sought

Solicitation number

36C24525Q0382

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES

Category

[Medical Equipment and Accessories and Supplies (10.2)](/categories/medical/medical-equipment-and-accessories-and-supplies)

Posted

2025-03-14

Deadline

2025-03-24

Place of performance

Baltimore, 21201

## Description

DISCLAIMER The sources sought notice is solely for information and planning purposes only and does not constitute a solicitation will be issued. NOTICE The sources sought notice does not constitute a Request for Quotation (RFQ) or a promise to issue an RFQ in the future. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this notice. It is the responsibility of the responders to monitor this site for additional information pertaining to this requirement. Responses or questions concerning the composition and requirements to this notice will not be returned. All capable contractors are welcome to respond to this notice and shall provide a brief capability statement that covers the information in the statement of work. The Capability Statement shall be limited to 5 pages. The Government will not review any other information or attachments that is more than the mentioned page limit. The Government will not review generic marketing materials that do not address the information contained herein or the attached documents. GENERAL Your response must address capabilities specific to the services required in the statement of work and must include the following: a. Company Name b. SAM Unique Entity ID & cage code which the company is registered in sam.gov and https://veterans.certify.sba.gov/ c. Company Address d. Point of contact(s) name e. Telephone number(s) f. Email address(s) g. Socioeconomic data h. Company Business Size Status and representations of your business i. Any previous contract(s) similar or the same as the required functional capabilities in the statement of work This is not a request for quotes. The estimated period of performance is September 2025 through August 2026\. All interested parties shall respond no later than 3/24/2025 at 12:00PM EST. Submit responses or suggestions via email to Kenneth.dougherty@va.gov. Telephone responses will not be accepted. STATEMENT OF WORK 4 Preventive maintenance visits a year for a Beta Star steam sterilizer, model N243660, serial# B0337, to ensure compliance with FDA guidelines for animal housing. As needed emergency service calls with 12 hour response time. PM Inspection Checklist- Visually check the outside for signs of leaks or damage Check steam, water and air supply lines for leaks Check the door travel operation Check and adjust door for 1/8" clearance Check the lower door switch operation Check the door lock cylinder operation Check the power door cylinder operation (if automatic) Check for proper door seal retraction Check the inside of the chamber for melted materials and clean Pull and clean the drain strainer Clean and check the chamber screen Check the door gasket and replace if necessary Check the traps, valves, solenoid and the plumbing for leaks Check load cart or shelf rack for proper alignment Check the airlines and valves for leaks Check liquid cycle Check the slow exhaust rate Check the operation of the vacuum system Check the 2 PSI pressure AND operation Run solid cycle @ 121C Run bio bag cycle @ 121C a.) Check the prevac depth b.) Check the charge pressure Check "water in chamber" safety sensor operation Check the dry cycle phase for proper operation Perform a leak test (annually) Replace air-in filter annually (indicate date changed) Check tempering valve for proper effluent quench The equipment is in the animal facility of the VA Hospital at 10 N Greene St, Baltimore, MD 21201\. All parts included except pumps/motors/controls Location(s): Baltimore Veterans Affairs Medical Center, 10 North Greene Street, Baltimore, MD 21201 End 

<!-- mobian-agent-ad sponsored="true" id="6fa32ce4-9284-47f3-a127-ccc7a1733c6f" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/30706322508e4dd8ba0ecf66e37bb6df/download)

## Contacts

* Kenneth Dougherty

Email and phone are in the source notice.

[Source notice](https://sam.gov/opp/072f7b820d0945b4b08acbef2c45590d/view)

[More from United States Department of Veterans Affairs posted in March 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-03)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"SOURCES SOUGHT NOTICE FOR PREVENTIVE MAINTENANCE SERVICES FOR EQUIPMENT STERILIZERS VA MEDICAL CENTER AT 10 N. GREENE ST., BALTIMORE, MD","description":"DISCLAIMER The sources sought notice is solely for information and planning purposes only and does not constitute a solicitation will be issued. NOTICE The sources sought notice does not constitute a Request for Quotation (RFQ) or a promise to issue an RFQ in the future. Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are advised that the Government will not pay for any information or administrative costs incurred in response to this notice. It is the responsibility of the responders to monitor this site for additional information pertaining to this requirement. Responses or questions concerning the composition and requirements to this notice will not be returned. All capable contractors are welcome to respond to this notice and shall provide a brief capability statement that covers the information in the statement of work. The Capability Statement shall be limited to 5 pages. The Government will not review any other information or attachments that is more than the mentioned page limit. The Government will not review generic marketing materials that do not address the information contained herein or the attached documents. GENERAL Your response must address capabilities specific to the services required in the statement of work and must include the following: a. Company Name b. SAM Unique Entity ID \u0026 cage code which the company is registered in sam.gov and https://veterans.certify.sba.gov/ c. Company Address d. Point of contact(s) name e. Telephone number(s) f. Email address(s) g. Socioeconomic data h. Company Business Size Status and representations of your business i. Any previous contract(s) similar or the same as the required functional capabilities in the statement of work This is not a request for quotes. The estimated period of performance is September 2025 through August 2026. All interested parties shall respond no later than 3/24/2025 at 12:00PM EST. Submit responses or suggestions via email to Kenneth.dougherty@va.gov. Telephone responses will not be accepted. STATEMENT OF WORK 4 Preventive maintenance visits a year for a Beta Star steam sterilizer, model N243660, serial# B0337, to ensure compliance with FDA guidelines for animal housing. As needed emergency service calls with 12 hour response time. PM Inspection Checklist- Visually check the outside for signs of leaks or damage Check steam, water and air supply lines for leaks Check the door travel operation Check and adjust door for 1/8\" clearance Check the lower door switch operation Check the door lock cylinder operation Check the power door cylinder operation (if automatic) Check for proper door seal retraction Check the inside of the chamber for melted materials and clean Pull and clean the drain strainer Clean and check the chamber screen Check the door gasket and replace if necessary Check the traps, valves, solenoid and the plumbing for leaks Check load cart or shelf rack for proper alignment Check the airlines and valves for leaks Check liquid cycle Check the slow exhaust rate Check the operation of the vacuum system Check the 2 PSI pressure AND operation Run solid cycle @ 121C Run bio bag cycle @ 121C a.) Check the prevac depth b.) Check the charge pressure Check \"water in chamber\" safety sensor operation Check the dry cycle phase for proper operation Perform a leak test (annually) Replace air-in filter annually (indicate date changed) Check tempering valve for proper effluent quench The equipment is in the animal facility of the VA Hospital at 10 N Greene St, Baltimore, MD 21201. All parts included except pumps/motors/controls Location(s): Baltimore Veterans Affairs Medical Center, 10 North Greene Street, Baltimore, MD 21201 End","url":"https://matchawards.com/department_of_veterans_affairs/posts/114162050589719141","identifier":"36C24525Q0382","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"10.2 Medical Equipment and Accessories and Supplies","url":"https://matchawards.com/categories/medical/medical-equipment-and-accessories-and-supplies"}],"availabilityStarts":"2025-03-14","availabilityEnds":"2025-03-24","validThrough":"2025-03-24T23:59:59-04:00","areaServed":"Baltimore, 21201","sameAs":"https://sam.gov/opp/072f7b820d0945b4b08acbef2c45590d/view"}