<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/113784090454222482" -->

---
title: Z1DZ--Special Remediation Building 25 CI… (36C26325Q0334) | Closed - MatchAwards
description: Z1DZ--Special Remediation Building 25 CI  636A6-25-101. United States Department of Veterans Affairs. Solicitation 36C26325Q0334. NAICS 562910 - Remediation Services. SDVOSB set-aside. Deadline 2025-01-14. THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals,...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/113784090454222482
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: Z1DZ--Special Remediation Building 25 CI… (36C26325Q0334) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/113784090454222482
og:description: Z1DZ--Special Remediation Building 25 CI  636A6-25-101. United States Department of Veterans Affairs. Solicitation 36C26325Q0334. NAICS 562910 - Remediation Services. SDVOSB set-aside. Deadline 2025-01-14. THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals,...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# Z1DZ--Special Remediation Building 25 CI 636A6-25-101

Status

Closed, the response deadline passed on Jan 14, 2025

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

Saint Paul, USA

Notice type

Sources Sought

Solicitation number

36C26325Q0334

NAICS

[562910 - Remediation Services](/groups/979)

PSC

Z1DZ - MAINTENANCE OF OTHER HOSPITAL BUILDINGS

Category

[Facility Related Services (4.4)](/categories/facilities-and-construction/facility-related-services)

Set-aside

[Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)](/contracts/veteran-owned)

Posted

2025-01-06

Deadline

2025-01-14

## Description

THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of qualified sources to perform the potential requirement. This sources sought notice is part of Market Research effort and invites contractors capable of fulfilling the requirement in accordance with the Statement of Work and Salient Characteristics.Â The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 23, is conducting market research to identify potential sources which can provide the following:Â STATEMENT OF WORK MOLD REMEDIATION SERVICES INTRODUCTION/BACKGROUND Air quality testing in a VA building, revealed levels of airborne microbial particles that exceed an acceptable level for a healthcare facility. Due to this hazard, the building has been vacated of all patients and staff and will remain so until it is safe to occupy. PROJECT OBJECTIVE Remediation services to remove or clean all surfaces and materials located inside Building. Building to be placed under negative pressure, with additional units to be used as air filtrations. HVAC system to be isolated, all diffusers removed, cleaned, then set aside, all flex ducting to be removed (to later be replaced), and all duct openings to be sealed. All carpet in the building to be removed. All ceiling tiles in the building to be removed. All drywall (including above the drop ceiling) that has microbial growth or moisture damage to be removed. All pipe and ductwork insulation showing evidence of growth or moisture damage to be removed. All building semi and non-porous surfaces - such as but not limited to cabinetry, countertops, metal, glass, rubber baseboards, lighting and plumbing fixtures - needs to be thoroughly disinfected via appropriate cleaning methods. SPECIFICATIONS MOLD REMEDIATION TECHNICAL SPECIFICATIONS PART 1 GENERAL SCOPE This specification covers the remediation of mold including removal, cleanup and disposal of mold contaminated materials from a VA building. The methods and procedures in this specification are based on the observations and previously collected background air samples. An estimate of the amount of material to be removed or cleaned is not given. The determination of the actual amounts, for bidding purposes, is the responsibility of the Contractor. By submitting a bid, the Contractor acknowledges that he has investigated and satisfied himself as to: The conditions affecting the work, including, but not limited to, physical conditions of the site which may affect site access, handling and storage of tools and materials, access to water, electricity or other utilities, or otherwise affect performance of required activities. The character and quantity of all surface and subsurface materials or obstacles to be encountered as far as this information is reasonably ascertainable from an inspection of the site, including exploratory work done by the Building Owner or a designated consultant, as well as information presented in drawings and specifications included with this Contract. Any failure by the Contractor to acquaint himself with available information will not relieve him from the responsibility for estimating properly the difficulty or cost of successfully performing the work. The Building Owner is not responsible for any conclusions or interpretations made by the Contractor on the basis of the information made available by the Building Owner. DESCRIPTION The work specified herein shall be the remediation of mold by competent persons trained, knowledgeable and qualified in the techniques of remediation, handling and disposal of mold contaminated materials and the subsequent cleaning of contaminated areas, who comply with all applicable Federal, State and local regulations and are capable of, and willing to perform, the work of this Contract. The Contractor shall supply all labor, materials, services, insurance, permits, licenses, patents, and equipment necessary to carry out the work in accordance with all applicable Federal, State and local regulations and these Specifications. The Contractor is responsible for restoring the work area and auxiliary areas utilized during the remediation to conditions at least equal to original conditions. (This excludes any material removed as part of scope.) Any damages caused during the performance of remediation activities shall be repaired by the Contractor (e.g., paint peeled off by barrier tape, nail holes, water damage, broken glass) at no additional expense to the Owner. APPLICABLE STANDARDS AND GUIDELINES All work under this Contract shall be done in strict accordance with all applicable Federal, State, and Local regulations, standards, and codes governing mold remediation and any other trade work done in conjunction with the remediation. The most recent edition of any relevant regulation, standard, document or code shall be in effect. Where conflict among the requirements or with these Specifications exists, the most stringent requirements shall be utilized. Specific requirements: Title 29, Code of Federal Regulations, 1926\. Occupational Safety and Health Administration (OSHA), U.S. Department of Labor. QUALITY ASSURANCE Bidders must be licensed as required by the Iowa Bureau of Labor. Bidders shall demonstrate prior experience on mold remediation projects of similar nature and scope through the submission of letters of reference from the Owners including the name, address, and telephone numbers of contact person (someone specifically familiar with the Contractor's work) for at least three (3) previous users of service if requested by the owners. The Owner reserves the right to reject bids for any reason that serves the best interests of the Owner or building occupants. The Owner also reserves the right to waive any technicality or irregularity in a bid. Failure to submit requested information/documentation can result in automatic disqualification of bid package. SUBMITTALS AND NOTICES Pre-remediation: Submit the location of the landfill to be used for disposal of the mold contaminated material. Submit a list of all personnel who will be involved in the remediation activity including, supervisors, workers, and any other personnel or agent who may be responsible for any aspect of the remediation activities. Submit documentation from a physician that all employees or agents have been medically monitored to determine whether they are physically capable of working while wearing the respirator required without suffering adverse health effects. Submit documentation of respirator fit testing for all employees and agents who must enter the work area. Document NIOSH approval of all respiratory protective devices utilized on-site. Submit a list of equipment for this project. With the Owner or Owner's representative, inspect the premises wherein all remediation and remediation related activities will occur and submit a statement signed by both, agreeing on building and fixture condition prior to the commencement of the work. Submit manufacturer's certification that HEPA vacuums, negative pressure ventilation units, and other local exhaust ventilation equipment conform to ANSI 29.2-79\. When rental equipment is to be used in remediation areas or to transport mold contaminated waste, a written notification concerning intended use of the rental equipment must be provided to the rental agency with a copy submitted to the Owner. During remediation activities: Submit weekly job progress reports detailing remediation activities and progress. Submit copies of all transport manifests, trip tickets and disposal receipts for all mold waste materials removed from the work area during the remediation process. Post in the clean room area of the worker decontamination enclosure: A list containing the names, addresses, and telephone numbers of the Contractor, the Owner, the Assessment Professional, the testing laboratory and any other personnel who may be required to assist during remediation activities. A logbook to record names of all personnel who enter the work area. A copy of emergency procedures. Telephone numbers of all emergency personnel and principals for this remediation project. The project will not be considered completed until all submittals are received by the owner. This will affect payment for the project. SITE SECURITY The work area is to be restricted only to authorized, trained, and protected personnel. These may include the Contractor's employees, employees of Subcontractors, Owner employees and representatives, state and local inspectors and any other designated individuals. Entry into the work area by unauthorized individuals shall be reported immediately to the Owner by the Contractor. Access to the work area shall be through a single worker decontamination system. All other means of access (doors, windows, hallways, etc.) shall be blocked or locked so as to prevent entry to or exit from the work area. The only exceptions for this rule are the waste pass out airlock which shall be sealed except during the removal of containerized mold waste from the work area, and emergency exits in case of fire or accident. Emergency exits shall not be locked from the inside; however, they shall be sealed with polyethylene sheeting and tape until needed. The Contractor shall have control of site security during remediation operations whenever possible, in order to protect work efforts and equipment. Contractor will have Owner's assistance in notifying building occupants of impending activity and enforcement of restricted access by Owner's employees. EMERGENCY PLANNING Emergency planning shall be developed prior to remediation initiation and agreed to by Contractor and Owner. Emergency planning shall include considerations of fire, explosion, toxic atmospheres, electrical hazards, slips, trips and falls, confined spaces, and heat related injury. Written procedures shall be developed and employee training in procedures shall be provided. Employees shall be trained in evacuation procedures in the event of work place emergencies. PART 2 MATERIALS AND EQUIPMENT MATERIALS General: Deliver all materials in the original packages, containers, or bundles bearing the name of the manufacturer and the brand name. Store all materials subject to damage off the ground, away from wet or damp surfaces, and under cover sufficient enough to prevent damage or contamination. Polyethylene sheeting for walls and stationary objects shall be a minimum of 4 mil thick. For floors and all other sheeting of at least 6 mil thickness shall be used in widths selected to minimize the frequency of joints. Tape - Duct, glass fiber, or other type capable of sealing adjacent sheets of polyethylene and capable of sealing polyethylene to dissimilar finished or unfinished surfaces under both wet and dry conditions including the use of amended water. Polyethylene sheeting utilized for worker decontamination enclosure shall be opaque white or black in color. Disposal bags shall be of 6 mil polyethylene. Disposal drums shall be metal or fiberboard with locking ring tops. EQUIPMENT General: A sufficient quantity of negative pressure ventilation units equipped with HEPA filtration shall be utilized to provide one workplace air change every 15 minutes or a static pressure within the work area of at least -0.02 inches of water column. These ventilation units must be commercially produced units and not self-manufactured. Ventilation units to be exhausted outside.The Contractor shall furnish a copy of their calculations to obtain this air flow or static pressure if requested by the Owner. Air purifying respirators equipped with HEPA filters will be required. A sufficient supply of filters shall be available in the clean change area. This requirement may be modified by the assessment professional if air sampling results indicate the need for more protection. Air purifying respirators with dual high efficiency (HEPA) filters may be utilized during work area preparation activities. Spectacle kits and eyeglasses must be provided for employees who wear glasses and who must wear full face piece respirators. Respirators shall be provided that have been tested and approved by the National Institute of Occupational Safety and Health for use in mold contaminated atmospheres. Full body disposable protective clothing, including head, body and foot coverings (unless using footwear as described in Section 2.02 (A)(6) consisting of material impenetrable by mold (Tyvek or equivalent) shall be provided to all workers in sizes adequate to accommodate movement without tearing. Additional safety equipment (e.g., hard hats, eye protection, safety shoes meeting the applicable ANSI Standard, disposable PVC gloves) as necessary, shall be provided to all workers and authorized visitors. Nonskid footwear shall be provided to all remediation workers. Disposable clothing shall be adequately sealed to the footwear to prevent body contamination. A sufficient supply of disposable mops, rags and sponges for work area decontamination shall be available. Mobile radios, telephones, etc. as required by the project will be provided by the contractor. Removal/Cleaning Equipment: Sufficient supply of scaffolds, ladders, lifts and hand tools shall be provided as needed. Sprayers with pumps capable of providing a water stream or mist for dust control. Rubber dustpans and rubber squeegees shall be provided for cleanup. Brushes utilized for removing loose mold containing material shall have nylon or fiber bristles, not metal. A sufficient supply of HEPA filtered vacuum systems shall be available during cleanup. PART 3 EXECUTION PREPARATION Post caution signs at any location and approaches to a location where airborne concentrations of mold may exceed ambient background levels. Additional signs may need to be posted following construction of workplace enclosure barriers. Shut down and lock out electric power to all work areas as necessary if wet conditions warrant. Provide temporary power and lighting. Ensure safe installation (including ground faulting) of temporary power sources and equipment by compliance with all applicable electrical code requirements and OSHA requirements for temporary electrical systems. Shut down and lock out all heating, cooling and air conditioning system (HVAC) components that are in, supply or pass through the work area. Seal all intake and exhaust vents in the work area with tape and 6 mil polyethylene. Also seal any seams in system components that pass through the work area. Remove all HVAC system filters and place in labeled 6 mil polyethylene bags for staging and eventual disposal as mold contaminated waste. Due to HVAC being offline during winter conditions, Contractor to provide temporary heat to maintain indoor temperature of 60 degrees Fahrenheit throughout building. The Contractor shall provide sanitary facilities for remediation personnel outside of the enclosed work area and maintain them in a clean and sanitary condition throughout the Project. Seal off all windows, doorways, elevator openings, corridor entrances, drains, ducts, grills, grates, diffusers, skylights, and any other openings between the work area and uncontaminated areas outside of the work area with 4 mil polyethylene sheeting and tape. Barrier walls will be constructed of 4 mil polyethylene sheeting extending from the ceiling to floor. WORKPLACE EXITS Worker Decontamination Enclosure System: Worker decontamination enclosure systems shall be provided at all locations where workers will enter or exit the work area. Worker decontamination enclosure systems constructed at the work site shall utilize 6 mil opaque white or black polyethylene sheeting or other acceptable materials for privacy. Detailed descriptions of portable, prefabricated units, if used, must be submitted for the Owner's approval. Plans must include floor plan with dimensions, materials, size, thickness, plumbing, and electrical utilities. The worker decontamination enclosure system shall consist of at least a clean room and an airlock. Entry and exit from the decontamination enclosure system chamber shall be through curtained doorways consisting of two sheets of overlapping polyethylene sheeting. One sheet shall be secured at the top and left side, the other sheet at the top and right side. Both sheets shall have weights attached to the bottom to ensure that they hang straight and maintain a seal over the doorway when not in use. The clean room shall be sized to adequately accommodate the work crew. Benches shall be provided as well as hooks for hanging up street clothes. Shelves for storing respirators shall also be provided in this area. Clean work clothes: clean disposable clothing, replacement filters for respirators, towels, and other necessary items shall be provided in adequate supply in the clean room. A location for postings shall also be provided in this area. Whenever possible, a lockable door shall be used to permit access into the clean room from outside the work area. Lighting, heat, and electricity shall be provided as necessary for comfort. This space shall not be used for storage of tools, equipment or materials, or as an office space. Waste Container Pass Out Airlock: The waste container pass out airlock shall be the same as the exit entry airlock. Emergency Exits: Emergency exits shall be established and clearly marked with duct tape arrows or other effective designations to permit easy identification from anywhere within the work area. They shall be secured to prevent access from uncontaminated areas and still permit emergency exiting. These exits shall be properly sealed with polyethylene sheeting which can be cut to permit egress if needed. These exits may be the worker decontamination enclosure, the waste pass out airlock and/or other alternative exits satisfactory to fire officials. ISOLATION OF THE WORKPLACE Maintenance of Enclosure Systems: Following completion of the construction of all polyethylene barriers and decontamination system enclosures, allow overnight settling to ensure that barriers will remain intact and secured to walls and fixtures before beginning actual remediation activities. All polyethylene barriers inside the workplace, in the worker decontamination enclosure system, in the waste container pass out airlock and at partitions constructed to isolate the work area from occupied areas shall be inspected at least twice daily, once prior to the start of each day's remediation activities. Document inspections and observations in the daily Project log. Damage and defects in the enclosure system are to be repaired immediately upon discovery. Negative pressure to be monitored with a continuous reading device. A record of this shall be furnished to the Owner. Use smoke tubes to test the effectiveness of the barrier system when directed by the Owner. At any time during the remediation activities after barriers have been erected, if visible material is observed outside of the work area or if damage occurs to barriers, work shall immediately stop, repairs be made to barriers, and debris/residue cleaned up using appropriate HEPA vacuuming and wet mopping procedures. Install and initiate operation of negative pressure ventilation equipment as needed to provide one air change in the work area every 15 minutes or produce a static pressure of -0.02 inches of water column. (See Section 2.02 (A)) Openings made in the enclosure system to accommodate these units shall be made airtight with tape and/or caulking as needed. If more than one unit is installed, they should be turned on one at a time, checking the integrity of wall barriers for sec 

<!-- mobian-agent-ad sponsored="true" id="c901d865-8e42-422a-a228-315dfc7197eb" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/facilities-and-construction/facility-related-services?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/154bca77b7e9481798749cf247eb9686/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b8a491729ecc40198d9117c40fae42bd/download)
* [Attachment 3](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/efdcab6418104c408c0eda37052de9fc/download)

[Source notice](https://sam.gov/opp/69892c3200884c889b8eb442d7c1db01/view)

[More from United States Department of Veterans Affairs posted in January 2025](/department%5Fof%5Fveterans%5Faffairs/archive/2025-01)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)
* [Veteran-Owned Small Business Set-Aside Contracts (SDVOSB and VOSB) Available Now](/contracts/veteran-owned)

```json
{"@context":"https://schema.org","@type":"Demand","name":"Z1DZ--Special Remediation Building 25 CI  636A6-25-101","description":"THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of qualified sources to perform the potential requirement. This sources sought notice is part of Market Research effort and invites contractors capable of fulfilling the requirement in accordance with the Statement of Work and Salient Characteristics.Â The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 23, is conducting market research to identify potential sources which can provide the following:Â STATEMENT OF WORK MOLD REMEDIATION SERVICES INTRODUCTION/BACKGROUND Air quality testing in a VA building, revealed levels of airborne microbial particles that exceed an acceptable level for a healthcare facility. Due to this hazard, the building has been vacated of all patients and staff and will remain so until it is safe to occupy. PROJECT OBJECTIVE Remediation services to remove or clean all surfaces and materials located inside Building. Building to be placed under negative pressure, with additional units to be used as air filtrations. HVAC system to be isolated, all diffusers removed, cleaned, then set aside, all flex ducting to be removed (to later be replaced), and all duct openings to be sealed. All carpet in the building to be removed. All ceiling tiles in the building to be removed. All drywall (including above the drop ceiling) that has microbial growth or moisture damage to be removed. All pipe and ductwork insulation showing evidence of growth or moisture damage to be removed. All building semi and non-porous surfaces - such as but not limited to cabinetry, countertops, metal, glass, rubber baseboards, lighting and plumbing fixtures - needs to be thoroughly disinfected via appropriate cleaning methods. SPECIFICATIONS MOLD REMEDIATION TECHNICAL SPECIFICATIONS PART 1 GENERAL SCOPE This specification covers the remediation of mold including removal, cleanup and disposal of mold contaminated materials from a VA building. The methods and procedures in this specification are based on the observations and previously collected background air samples. An estimate of the amount of material to be removed or cleaned is not given. The determination of the actual amounts, for bidding purposes, is the responsibility of the Contractor. By submitting a bid, the Contractor acknowledges that he has investigated and satisfied himself as to: The conditions affecting the work, including, but not limited to, physical conditions of the site which may affect site access, handling and storage of tools and materials, access to water, electricity or other utilities, or otherwise affect performance of required activities. The character and quantity of all surface and subsurface materials or obstacles to be encountered as far as this information is reasonably ascertainable from an inspection of the site, including exploratory work done by the Building Owner or a designated consultant, as well as information presented in drawings and specifications included with this Contract. Any failure by the Contractor to acquaint himself with available information will not relieve him from the responsibility for estimating properly the difficulty or cost of successfully performing the work. The Building Owner is not responsible for any conclusions or interpretations made by the Contractor on the basis of the information made available by the Building Owner. DESCRIPTION The work specified herein shall be the remediation of mold by competent persons trained, knowledgeable and qualified in the techniques of remediation, handling and disposal of mold contaminated materials and the subsequent cleaning of contaminated areas, who comply with all applicable Federal, State and local regulations and are capable of, and willing to perform, the work of this Contract. The Contractor shall supply all labor, materials, services, insurance, permits, licenses, patents, and equipment necessary to carry out the work in accordance with all applicable Federal, State and local regulations and these Specifications. The Contractor is responsible for restoring the work area and auxiliary areas utilized during the remediation to conditions at least equal to original conditions. (This excludes any material removed as part of scope.) Any damages caused during the performance of remediation activities shall be repaired by the Contractor (e.g., paint peeled off by barrier tape, nail holes, water damage, broken glass) at no additional expense to the Owner. APPLICABLE STANDARDS AND GUIDELINES All work under this Contract shall be done in strict accordance with all applicable Federal, State, and Local regulations, standards, and codes governing mold remediation and any other trade work done in...","url":"https://matchawards.com/department_of_veterans_affairs/posts/113784090454222482","identifier":"36C26325Q0334","category":"562910 - Remediation Services","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"Z1DZ - MAINTENANCE OF OTHER HOSPITAL BUILDINGS"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"4.4 Facility Related Services","url":"https://matchawards.com/categories/facilities-and-construction/facility-related-services"}],"availabilityStarts":"2025-01-06","availabilityEnds":"2025-01-14","validThrough":"2025-01-14T23:59:59-05:00","sameAs":"https://sam.gov/opp/69892c3200884c889b8eb442d7c1db01/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"},{"@type":"ListItem","position":3,"name":"Veteran-owned","item":"https://matchawards.com/contracts/veteran-owned"}]}
```

