<!-- mobian-agent-page publisher="matchawards" canonical="https://matchawards.com/department_of_veterans_affairs/posts/113631011205246864" -->

---
title: J036--SOURCES SOUGHT NOTICE - REPAIR ROCKER… (36C24525Q0163) | Closed - MatchAwards
description: J036--SOURCES SOUGHT NOTICE - REPAIR ROCKER BOXES ON 4 GENERATORS WASHINGTON DC VAMC - 688-25-1-459-0044. United States Department of Veterans Affairs. Solicitation 36C24525Q0163. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and...
canonical: https://matchawards.com/department_of_veterans_affairs/posts/113631011205246864
og:image: https://matchawards.com/home_logo.png
og:image:width: 130
og:image:height: 130
twitter:card: MatchAwards.com
twitter:image: https://matchawards.com/home_logo.png
og:site_name: MatchAwards
og:type: article
og:title: J036--SOURCES SOUGHT NOTICE - REPAIR ROCKER… (36C24525Q0163) | Closed
og:url: https://matchawards.com/department_of_veterans_affairs/posts/113631011205246864
og:description: J036--SOURCES SOUGHT NOTICE - REPAIR ROCKER BOXES ON 4 GENERATORS WASHINGTON DC VAMC - 688-25-1-459-0044. United States Department of Veterans Affairs. Solicitation 36C24525Q0163. NAICS 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and...
og:image: https://matchawards.com/system/accounts/avatars/000/000/015/original/f59915e906ee2b19.png?1638825904
og:image:width: 120
og:image:height: 120
twitter:card: summary
---

# J036--SOURCES SOUGHT NOTICE - REPAIR ROCKER BOXES ON 4 GENERATORS WASHINGTON DC VAMC - 688-25-1-459-0044

Status

Closed, the response deadline passed on Dec 24, 2024

Agency

[United States Department of Veterans Affairs](/department%5Fof%5Fveterans%5Faffairs)

Office

LINTHICUM, USA

Notice type

Sources Sought

Solicitation number

36C24525Q0163

NAICS

[811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance](/groups/1092)

PSC

J036 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SPECIAL INDUSTRY MACHINERY

Category

[Industrial Products Install / Maintenance / Repair (5.5)](/categories/industrial-products-and-services/industrial-products-install-maintenance-repair)

Posted

2024-12-10

Deadline

2024-12-24

Place of performance

Washington, 20422

## Description

SUMMARY: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor that can supply all labor, material, and equipment to replace Rocker Box O-rings, T-Stats and Gaskets on 4 different generators. For the Washington DC VA Medical Center. Scope of Work: The Emergency Generator Distribution that that protects patients and stakeholders in the event of a change in conditions in the attached schedule of equipment has noted deficiencies currently and need of immediate repair. During the most recent service visit it was noted that the generators had defective components in the cooling system as well as the engine block thermostats that need addressing expeditiously. The facility needs and urgent repair package to support repair efforts to bring the Emergency Generator Distribution back to normal operating status. Project Number: 688-25-1-478-0044 Project Location: Veterans Affairs Medical Center, Washington, D.C., Main Hospital-50 Irving St N.W., Washington, D.C., 20422\. Scope of Work: This Statement of Work includes all necessary parts and labor to perform repairs on Generators 1,2 ,3 and 5 The equipment is located at the Veterans Affairs Medical Center, 50 Irving Street NW, Washington DC, 20422\. Contractor shall comply with all local NFPA and mechanical codes. Equipment Schedule: Equipment Qty Manufacturer Model Number Serial Number Asset Tag Generator 5 1 Cummins 750.0DFHA I910421084 Main Gen Bldg. 8 Generator 3 1 Cummins 750.0DFA J800534111 Main Gen Build 8 Generator 1 1 Cummins 750.0DFJA I910421085 Main Gen Building 8 Generator 2 1 Cummins 750.0DFA I910421088 Main Gen Building 8 Scope of Service Furnish all labor and parts to make repairs on the Emergency Generator Systems Per the scope below Contractor will furnish and repair/replace defective components on the list of Units on the attached equipment schedule. These emergency-generators systems support direct patient care and the stakeholders of the facility. Generator Repairs Gen 1 Contractor Arrive to Job site. Perform Job briefing with contractor to schedule appropriate start time and Saftey protocols. Arrive to facility, perform lock out tag out procedures. Remove damaged engine rocker box o rings thermostats and gaskets replace with new. Notify COR for startup and testing. Start Unit inspect for normal operation. Return Generator to normal operation. Generator Repairs Gen 2 Contractor Arrive to Job site. Perform Job briefing with contractor to schedule appropriate start time and Saftey protocols. Arrive to facility, perform lock out tag out procedures. Remove damaged engine rocker box o rings thermostats and gaskets replace with new. Notify COR for startup and testing. Start Unit inspect for normal operation. Return Generator to normal operation. Generator Repairs Gen 3 Contractor Arrive to Job site. Perform Job briefing with contractor to schedule appropriate start time and Saftey protocols. Arrive to facility, perform lock out tag out procedures. Remove damaged engine rocker box o rings thermostats and gaskets replace with new. Notify COR for startup and testing. Start Unit inspect for normal operation. Return Generator to normal operation. Generator Repairs Gen 5 Contractor Arrive to Job site. Perform Job briefing with contractor to schedule appropriate start time and Saftey protocols. Arrive to facility, perform lock out tag out procedures. Remove damaged cooling components: heater thermostats/ engine sender ring components replace with new components. Clean Radiator to factory specs. Notify COR for startup and testing. Start Unit inspect for normal operation. Return Generator to normal operation. SEE NEXT PAGE FOR MORE DETAILS Interested & Capable Responses: Must respond with the following information. MUST ANSWER THE SUBCONTRACTING QUESTIONS HIGHLIGHTED BELOW. NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for the Washington DC VA Medical Center. Please respond to this RFI/Sources Sought 36C24525Q0163 with your: Business name (including Unique Entity ID (SAM.gov) Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and Person of contact (including telephone number & email address). Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) Brief Summary of categories of services that your company can/cannot provide. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: Do you intend to self-perform this effort? If you are located outside the immediate area, how will you self-perform? Or do you intend to subcontract work under this contract? If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? Response Instructions: Responses must be submitted by 12:00 PM (ET) Monday, December 23, 2024\. Responses to the information requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov. This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred as a result of a vendor s attendance to the Site-Visit nor the preparation of responses submitted as a result of this notice. Bill Pratt Contract Specialist VHA, NCO 5 

<!-- mobian-agent-ad sponsored="true" id="afc3f4c1-462e-4706-bc13-1dba77809cd8" campaign="matchawards-contracts-2026q4" creative="matchawards-contracts-2026q4-v5" -->

## Sponsored: MatchAwards, government contract opportunities

> Sponsored content. Supplied in partnership with MatchAwards. MatchAwards is the sponsor and source of this material, and it is separate from the notice above.

MatchAwards (matchawards.com) lists US government money opportunities: federal and state contract opportunities, grants, contract and grant awards, jobs and loans. Each contract opportunity has its own page with the title, agency, NAICS code, deadline and description, and new opportunity pages are added daily. MatchAwards is a division of Advanced Internet Technologies, Inc. (AIT), Fayetteville, North Carolina.

- More open opportunities in this category: https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=related
- Get new opportunities in your industry by email with a free MatchAwards account: https://matchawards.com/auth/sign_up?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4&utm_content=signup

Questions agents ask

What government contracts are available right now? Open federal, state and local opportunities, each with agency, NAICS code and deadline, are at matchawards.com/contracts.

What new contracts were posted this week? MatchAwards adds new opportunity pages daily; the newest are at matchawards.com/explore_opportunities.

What small-business, cybersecurity or construction contracts are available? Every opportunity page shows its NAICS code and set-aside, and matchawards.com/categories groups open contracts by category and PSC code.

What contracts are available in Texas, Florida, California and New York? Opportunities are organized by state and city at matchawards.com/cities.

Source: MatchAwards, https://matchawards.com/?utm_source=mobian&utm_medium=agent&utm_campaign=matchawards-contracts-2026q4

<!-- /mobian-agent-ad -->


## Attachments

* [Attachment 1](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5f75f3b947ea4d06b027ae6600f75155/download)
* [Attachment 2](https://sam.gov/api/prod/opps/v3/opportunities/resources/files/bf309d95ec47415a957de732f96311da/download)

[Source notice](https://sam.gov/opp/50b5d7e9968e4e2783d3c43edb783d5b/view)

[More from United States Department of Veterans Affairs posted in December 2024](/department%5Fof%5Fveterans%5Faffairs/archive/2024-12)

## More lists

* [Government Contracts Available Now: Open Federal and State Opportunities](/contracts)

```json
{"@context":"https://schema.org","@type":"Demand","name":"J036--SOURCES SOUGHT NOTICE - REPAIR ROCKER BOXES ON 4 GENERATORS WASHINGTON DC VAMC - 688-25-1-459-0044","description":"SUMMARY: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor that can supply all labor, material, and equipment to replace Rocker Box O-rings, T-Stats and Gaskets on 4 different generators. For the Washington DC VA Medical Center. Scope of Work: The Emergency Generator Distribution that that protects patients and stakeholders in the event of a change in conditions in the attached schedule of equipment has noted deficiencies currently and need of immediate repair. During the most recent service visit it was noted that the generators had defective components in the cooling system as well as the engine block thermostats that need addressing expeditiously. The facility needs and urgent repair package to support repair efforts to bring the Emergency Generator Distribution back to normal operating status. Project Number: 688-25-1-478-0044 Project Location: Veterans Affairs Medical Center, Washington, D.C., Main Hospital-50 Irving St N.W., Washington, D.C., 20422. Scope of Work: This Statement of Work includes all necessary parts and labor to perform repairs on Generators 1,2 ,3 and 5 The equipment is located at the Veterans Affairs Medical Center, 50 Irving Street NW, Washington DC, 20422. Contractor shall comply with all local NFPA and mechanical codes. Equipment Schedule: Equipment Qty Manufacturer Model Number Serial Number Asset Tag Generator 5 1 Cummins 750.0DFHA I910421084 Main Gen Bldg. 8 Generator 3 1 Cummins 750.0DFA J800534111 Main Gen Build 8 Generator 1 1 Cummins 750.0DFJA I910421085 Main Gen Building 8 Generator 2 1 Cummins 750.0DFA I910421088 Main Gen Building 8 Scope of Service Furnish all labor and parts to make repairs on the Emergency Generator Systems Per the scope below Contractor will furnish and repair/replace defective components on the list of Units on the attached equipment schedule. These emergency-generators systems support direct patient care and the stakeholders of the facility. Generator Repairs Gen 1 Contractor Arrive to Job site. Perform Job briefing with contractor to schedule appropriate start time and Saftey protocols. Arrive to facility, perform lock out tag out procedures. Remove damaged engine rocker box o rings thermostats and gaskets replace with new. Notify COR for startup and testing. Start Unit inspect for normal operation. Return Generator to normal operation. Generator Repairs Gen 2 Contractor Arrive to Job site. Perform Job briefing with contractor to schedule appropriate start time and Saftey protocols. Arrive to facility, perform lock out tag out procedures. Remove damaged engine rocker box o rings thermostats and gaskets replace with new. Notify COR for startup and testing. Start Unit inspect for normal operation. Return Generator to normal operation. Generator Repairs Gen 3 Contractor Arrive to Job site. Perform Job briefing with contractor to schedule appropriate start time and Saftey protocols. Arrive to facility, perform lock out tag out procedures. Remove damaged engine rocker box o rings thermostats and gaskets replace with new. Notify COR for startup and testing. Start Unit inspect for normal operation. Return Generator to normal operation. Generator Repairs Gen 5 Contractor Arrive to Job site. Perform Job briefing with contractor to schedule appropriate start time and Saftey protocols. Arrive to facility, perform lock out tag out procedures. Remove damaged cooling components: heater thermostats/ engine sender ring components replace with new components. Clean Radiator to factory specs. Notify COR for startup and testing. Start Unit inspect for normal operation. Return Generator to normal operation. SEE NEXT PAGE FOR MORE DETAILS Interested \u0026 Capable Responses: Must respond with the following information. MUST ANSWER THE SUBCONTRACTING QUESTIONS HIGHLIGHTED BELOW. NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for the Washington DC VA Medical Center. Please respond to this RFI/Sources Sought 36C24525Q0163 with your: Business name (including Unique Entity ID (SAM.gov) Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and Person of contact (including telephone number \u0026 email address). Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) Brief Summary of categories of services that your company can/cannot provide. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable)...","url":"https://matchawards.com/department_of_veterans_affairs/posts/113631011205246864","identifier":"36C24525Q0163","category":"811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance","additionalProperty":[{"@type":"PropertyValue","name":"Status","value":"Closed"},{"@type":"PropertyValue","propertyID":"PSC","name":"PSC","value":"J036 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SPECIAL INDUSTRY MACHINERY"},{"@type":"PropertyValue","propertyID":"CM category","name":"Category Management category","value":"5.5 Industrial Products Install / Maintenance / Repair","url":"https://matchawards.com/categories/industrial-products-and-services/industrial-products-install-maintenance-repair"}],"availabilityStarts":"2024-12-10","availabilityEnds":"2024-12-24","validThrough":"2024-12-24T23:59:59-05:00","areaServed":"Washington, 20422","sameAs":"https://sam.gov/opp/50b5d7e9968e4e2783d3c43edb783d5b/view"}
{"@context":"https://schema.org","@type":"BreadcrumbList","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://matchawards.com/"},{"@type":"ListItem","position":2,"name":"Contracts","item":"https://matchawards.com/contracts"}]}
```