4310--Solicitation for Powerex Air Compressors and Dryers.
- Status
- Closed, the response deadline passed on Dec 17, 2024
- Agency
- United States Department of Veterans Affairs
- Office
- ALBANY, USA
- Notice type
- Combined Synopsis/Solicitation
- Solicitation number
- 36C24225Q0164
- NAICS
- 335999 - All Other Miscellaneous Electrical Equipment and Component Manufacturing
- PSC
- 4310 - COMPRESSORS AND VACUUM PUMPS
- Category
- Machinery & Components (5.1)
- Set-aside
- Total Small Business Set-Aside (FAR 19.5)
- Posted
- 2024-12-10
- Deadline
- 2024-12-17
- Place of performance
- New York, 10010
Description
2 Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular [FAC Number: 2024-07]. This solicitation is set-aside for Small Business (SB). The associated North American Industrial Classification System (NAICS) code for this procurement is 335999, with a small business size standard of 600 employees. The FSC/PSC is 4310. The Manhattan VAMC and Brooklyn VAMC requires a brand name only acquisition of Powerex Oil Free Scroll Air Compressors and Desiccant Dryers that will be used with the Steris Endodry Endoscope drying and storage cabinets and the Ivoclar PrograMill PM7 dental milling machine currently in use at the VA Facilities. The two (2) air compressors used at the Manhattan VAMC must meet the following conditions: Air Supply Requirements: Quality: ISO 8573-1:2010 class 1.2.1 Particle Size: Incoming air filtered down to <1 micron in size. Moisture Content: Pressure dew point (PDP) of -40°C or better required and no liquid water. Oil Content: < 0.01mg of oil per cubic meter of compressed air (liquid, aerosol, or vapor oil). Pressure: The below pressures are required at the point of cabinet connection. Facility should consult with their Maintenance Department or their qualified air vendor to identify potential issues with the air supply. ENDODRY Cabinet for ADVANTAGE PLUS Endoscope Reprocessor: 58-145 psi (4-10 bar). Volume: The below volumes are required at the point of cabinet connection. ADVANTAGE PLUS Endoscope Reprocessor/ENDODRY Cabinet: Minimum requirement of 4.2 scfm (120 L/min ANR) per cabinet. Flexible Air Hose: A 5-foot (1.5 Meter) line is included with each cabinet. One end will be pre-configured to connect to ENDODRY Drying Cabinet. Open end will be ¼ or 6mm inner diameter and it is the responsibility of the facility to make that connection to their air supply line. Noise Level: No more than 51dB Combined Compressor & Dryer Dimensions: No bigger than 34 x 37 x 41 External 60-gallon tank dimensions: No bigger than 56 x 29 x 30 Electrical: Compressor 208V, three phase Compressor Type: Scroll, oil free. Dryer Type: Desiccant The air compressor used at the Brooklyn VAMC must meet the follow conditions: Air Supply Requirements: Quality: ISO 8573-1:2010 class 3.4.3 Particle Size: Class 3, Incoming air filtered down to <5 micron in size. Moisture Content: Class 4, Maximum pressure condensation point +3 C (+37.4 F) Maximum Oil Content: Class 3, Maximum oil content 1mg/m3 Pressure: Continuous 90 110 psi Volume: Continuous 205 l/min or 7.24CFM Dry compressed air, clean and oil-free Compressed Air Tube Hose: 8mm (0.3in) outside diameter connection Noise Level: No more than 51dB Combined Compressor & Dryer Dimensions: No bigger than 34 x 37 x 41 External 60-gallon tank dimensions: No bigger than 56 x 29 x 30 Electrical: Compressor 208V, three phase Compressor Type: Scroll, oil free. Dryer Type: Desiccant Item/Quantity Description: Item Description Mfr. Part Qty 1 5HP OIL FREE SCROLL COMPRESSOR, 13 GALLON INTERNAL TANK. 116PSI INTERGRATED DESICCANT AIR DRYER W/ FILTER. STARTUP INCLUDED FOR MANHATTAN VAMC POWEREX SES 0508-X-DD 2 2 60 GALLON HORIZONTAL TANK (SHIPPED LOOSE) POWEREX AR022500ST 1 3 FILTERS: 2 COMPRESSOR INLET FILTER ELEMENT 4 DRYER PRE FILTER ELEMENT 4 DRYER POST FILTER ELEMENT 1 4 INSTALLATION LABOR, MATERIALS FOR MANHATTAN VAMC 1 5 5HP OIL FREE SCROLL COMPRESSOR, 13 GALLON INTERNAL TANK. 145PSI INTERGRATED DESICCANT AIR DRYER W/ FILTER. STARTUP INCLUDED FOR BROOKLYN VAMC WITH 60 GALLON EXTERNAL TANK (TANK MOUNTED CONFIGURATION) POWEREX SES 0508-X-DD-60GALL 1 6 INSTALLATION LABOR, MATERIALS FOR BROOKLYN VAMC 1 Scope of Work The VA New York Harbor Healthcare System, Manhattan Campus (Manhattan VAMC) and Brooklyn Campus (Brooklyn VAMC), require the purchase and installation of three air compressors, three desiccant dryers and two sixty-gallon air tanks. Two 5 horsepower 115psi maximum pressure scroll air compressors with desiccant dryers and a 60-gallon external tank will be used to feed two STERIS ENDODRY endoscope drying and storage cabinets in the Manhattan VAMC Gastroenterology (GI) unit. Additionally, the Manhattan VAMC Facilities Engineering department requires a one-year supply of spare filters for the air compressors and dryers. At the Brooklyn VAMC Dental Clinic, one 5 horsepower 145 psi maximum pressure air compressor with a desiccant dryer and a 60-gallon external tank will be used to feed a Ivoclar PrograMill PM7 dental milling. Objectives/Background The Manhattan VAMC and Brooklyn VAMC require oil free scroll air compressors, desiccant dryers, and 60-gallon external tanks that are compatible with the STERIS ENDODRY endoscope drying and storage cabinets and the Ivoclar PrograMill PM7 dental milling machine. Delivery and Installation The vendor will deliver the new equipment to each VAMC. Please find the exact delivery locations below. For the Manhattan VAMC installation, the vendor will be responsible for rigging and placing the equipment in the designated room discussed for installation in the GI unit. The vendor will provide plumbing equipment as per NFPA 99 specifications and will use cleaned and capped K Copper tubing and fittings. The vendor will also be responsible for brazing and nitrogen purging the new air piping as well as connecting the scroll air compressors and dryers and tank in order to feed the STERIS ENDODRY drying and storage cabinets. In addition, the vendor will also run drainpipe for the desiccant dryer. For the Brooklyn VAMC installation, the vendor will also rig and place the equipment in the designated area discussed for installation in the Dental unit. The vendor will be responsible for plumbing the new air compressor, desiccant dryer, and tank to the PrograMill PM7 dental milling machine, as well as disconnecting the existing air source feeding into the milling machine. The vendor is responsible for running drainpipe for the dessicant dryer. The vendor is also responsible for providing Biomedical Engineering and Facilities Engineering with installation reports, providing details on the installation of the equipment and the most updated status of the equipment as of installation completion. Additionally, any inspection reports of the equipment delivered should be provided to Facilities Engineering to document the functionality and service record of the equipment. Place of Delivery: New York Harbor, Manhattan VA Medical Center Warehouse: 423 East 23rd Street New York, NY 10010 and New York Harbor, Brooklyn VA Medical Center Warehouse: 800 Poly Place Brooklyn, NY 11209 Place of Installation: New York Harbor, Manhattan VA Medical Center: 423 East 23rd Street New York, NY 10010 GI Unit: Building 1, Floor 11N, Room# 11140 New York Harbor, Brooklyn VA Medical Center: 800 Poly Place Brooklyn, NY 11209 Dental Unit: Building 1, Floor 1 Travel/Parking The contractor will be responsible for their travel. As stated earlier, due to other construction projects and limited parking available at the site, contractor must coordinate any parking needs with the assigned COR and the Police Service. Details of any vehicles entering the site must be provided in advance. (Driver s Full Name, Driver s License Number, Vehicle Description, Vehicle License Plate Number) Government-Furnished Property Vendor will need access to main air line that the air compressors will connect to. Each desiccant dryer will need to be connected to a drain line. Facilities Engineering will provide electrical work required to complete the installation of the new equipment. Education and Training Requirements The Vendor shall be responsible for ensuring that vendor employees providing work on the required equipment are fully trained and completely competent to perform the required work. The vendor must also ensure that their technicians possess the valid New York City licenses needed to perform plumbing work in New York and Kings counties. VA Patient Privacy and Network Infrastructure The equipment listed within this procurement package will not access the VA Network and will not store sensitive patient information, therefore no vendor will require access to the VA Network. Recalls The Vendor shall immediately notify all affected VA Medical Centers and designated POC in the event of a device recall, removal, required adjustment, or required modification that is suggested or mandated by the Vendor, distributor, manufacturer, or any regulatory or government agency. The following information shall be included in this notification: A complete item description and identification (to include lot and serial numbers where applicable). Administrative identification data including order numbers and order date. Reasons for recall, removal, adjustment, or modification; and Instructions for appropriate corrective action. Defective Items/Warranty All compressors and associated equipment must come with at least a one-year warranty upon delivery including technical support and parts replacement as needed for full functionality. The vendor will need to deliver the required compressors within four to six weeks of contract award. The vendor must also supply the required installation support within ninety days of equipment delivery. The vendor will need to deliver the required compressors within four to six weeks of contract award. The vendor must also supply the required installation support within 30 days of equipment delivery. The full text of FAR provisions or clauses may be accessed electronically at http://acquisition.gov/comp/far/index.html. The following solicitation provisions apply to this acquisition: FAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services (SEP 2023) FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services (MAY 2024) Offerors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://www.sam.gov/portal in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services. If paragraph (j) of the provision is applicable, a written submission is required. The following contract clauses apply to this acquisition: FAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (NOV 2023) FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Products and Commercial Services (MAY 2024) The following subparagraphs of FAR 52.212-5 are applicable: (a) The Contractor shall comply with the following Federal Acquisition Regulation (FAR) clauses, which are incorporated in this contract by reference, to implement provisions of law or Executive orders applicable to acquisitions of commercial products: 52.203-13, Contractor Code of Business Ethics and Conduct (Nov 2021) 52.222-3, Convict Labor (June 2003) 52.222-19, Child Labor-Cooperation with Authorities and Remedies (Feb 2024) 52.222-21, Prohibition of Segregated Facilities (Apr 2015) 52.222-26, Equal Opportunity (Sept 2016) (E.O.11246) 52.222-35, Equal Opportunity for Veterans (Jun 2020) (38 U.S.C. 4212) 52.222-36, Equal Opportunity for Workers with Disabilities (Jun 2020) (29 U.S.C. 793) 52.222-50, Combating Trafficking in Persons (Nov 2021) 52.223-18, Encouraging Contractor Policies to Ban Text Messaging While Driving (Jun 2020) (E.O. 13513) 52.225-1, Buy American-Supplies (Oct 2022) (41 U.S.C. chapter 83) 52.225-2, Buy American Certificate (Oct. 2022) 52.232-33, Payment by Electronic Funds Transfer- System for Award Management (Oct 2018) 852.212-71 Gray Market and Counterfeit Items (Feb 2023) 852.219-76 VA Notice of Limitations on Subcontracting-Certificate of Compliance for Supplies and Products Buy American Certificate (Oct 2022) (1) The Offeror certifies that each end product, except those listed in paragraph (b) of this provision, is a domestic end product and that each domestic end product listed in paragraph (c) of this provision contains a critical component. (2) The Offeror shall list as foreign end products those end products manufactured in the United States that do not qualify as domestic end products. For those foreign end products that do not consist wholly or predominantly of iron or steel or a combination of both, the Offeror shall also indicate whether these foreign end products exceed 55 percent domestic content, except for those that are COTS items. If the percentage of the domestic content is unknown, select no . (3) The Offeror shall separately list the line-item numbers of domestic end products that contain a critical component (see FAR 25.105). (4) The terms commercially available off-the-shelf (COTS) item, critical component, domestic end product, end product, and foreign end product are defined in the clause of this solicitation entitled Buy American Supplies. Foreign End Products: Line-Item No. Description Country of Origin Exceeds 55% domestic content (yes/no) [List as necessary] Domestic end products containing a critical component: Line-Item No. [List as necessary] The Government will evaluate offers in accordance with the policies and procedures of part 25 of the Federal Acquisition Regulation. All quoters shall submit the following: One (1) Copy. All quotes shall be sent to: Jonatan.rondon@va.gov VAAR 852.219-76 VA Notice of Limitations on Subcontracting Certificate of Compliance for Supplies and Products. (a)Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that (1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Offeror check the appropriate box] (i) [ ] In the case of a contract for supplies or products (other than from a non-manufacturer of such supplies), it will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (ii) [ ] In the case of a contract for supplies from a nonmanufacturer, it will supply the product of a domestic small business manufacturer or processor, unless a waiver as described in 13 CFR 121.406(b)(5) is granted. The offeror understands that, as provided in 13 CFR 121.406(b)(7), such a waiver has no effect on requirements external to the Small Business Act, such as the Buy American Act or the Trade Agreements Act. (2) Manufacturer or nonmanufacturer representation and certification. [Offeror fill-in check each applicable box below. The offeror must select the applicable provision below, identifying itself as either a manufacturer or nonmanufacturer]: (i) [ ] Manufacturer or producer. The offeror certifies that it is the manufacturer or producer of the end item being procured, and the end item is manufactured or produced in the United States, in accordance with paragraph (a)(1)(i). (ii) [ ] Nonmanufacturer. The offeror certifies that it qualifies as a nonmanufacturer in accordance with the requirements of 13 CFR 121.406(b) and paragraph (a)(1)(ii).The offeror further certifies it meets each element below as required in order to qualify as a nonmanufacturer. [Offeror fill-in check each box below.] [ ] The offeror certifies that it does not exceed 500 employees (or 150 employees for the Information Technology Value Added Reseller exception to NAICS code 541519, which is found at 13 CFR 121.201, footnote 18). [ ] The offeror certifies that it is primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied. [ ] The offeror certifies that it will take ownership or possession of the item(s) with its personnel, equipment, or facilities in a manner consistent with industry practice. (iii) [ ] The offeror certifies that it will supply the end item of a small business manufacturer, processor, or producer made in the United States, unless a waiver as provided in 13 CFR 121.406(b)(5) has been issued by SBA. [ ] If this is a multiple item acquisition, the offeror certifies that at least 50% of the estimated contract value is composed of items that are manufactured by small business concerns. (3) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution. (4) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following: (i) Referral to the VA Suspension and Debarment Committee; (ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and (iii) Prosecution for violating 18 U.S.C. 1001. (b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract or to determine whether the offeror qualifies as a manufacturer or nonmanufacturer in compliance with the limitations on subcontracting requirement. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed. (c)The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed, and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award. Certification: I hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror]. Printed Name of Signee:________________________________________ Printed Title of Signee:_________________________________________ Signature:___________________________________________________ Date:_____________________ Company Name and Address:___________________________________ (End of cAttachments
More from United States Department of Veterans Affairs posted in December 2024